User Manual Complete Prosthetic Kit (CPK)

Similar documents
High-end solution STEP-BY-STEP USER GUIDE

Step-by-Step Cemented Bridge Using Using CPK Abutments. Internal Hex. Implant System

FOR C1 & V3 IMPLANTS STEP-BY-STEP GUIDED SURGICAL PROCEDURE

INSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)

NEW. The SmartFix Concept Prosthetic solution on tilted implants. SmartFix

SimpleLine II Surgical / Prosthesis Manual

Very small abutment head easy and secure handling. Ankylos. The SmartFix concept. Prosthetic solution on angled implants

Abutment level impression Ⅰ. Combi abutment/dual abutment Multi units

IMPRESSION PROCEDURES TRAINING MANUAL

SwissPlant Prosthetic Catalog. SwissPlant

Quick start Prosthetics

IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit

Legacy Prosthetic Catalog

INTERNAL HEXAGON PROSTHETIC OPTIONS. MIS Corporation. All Rights Reserved.

Blue Sky Bio Multi unit Abutments BIO Multi-Units are available for all our Bone Level Implants

cement-retained single crowns using cementable abutments

Multi-Unit Abutment System SIC Safe on Four. Optimum use of available bone by angled placement of implants

HEXAGON Implant System

» For multi-unit restorations -

Plastic Cylinders Gold-Plastic Cylinders Prosthetic Abutments CONICAL CONNECTION PROSTHETIC OPTIONS. MIS Corporation. All rights Reserved.

CAD/CAM Prosthetic Solutions

open tray technique using the direct pick-up coping

Multi-Unit Abutment Guide

4766 Research Dr. San Antonio, TX insightdentalsystems.com

closed tray technique using the indirect transfer coping

prosthetic technique manual

closed tray pick-up technique using the snap coping

NARROW DIAMETER implant

Straumann Screw-retained Prosthetics

SS Implant System 2013 PROSTHETIC PROCEDURE

INDEX. Pag. 12. Pag. 05. Pag. 06. Pag. 13. Pag. 06. Pag. 14. Pag. 15. Pag. 15. Pag. 15. Pag. 15. Pag. 08. Pag. 16. Pag. 09. Pag.

Titanium Base abutments plus screw and associated restorative and dental laboratory components.

Description: Prosthetic Components for dental restoration under CE-Series, CL- Series, CN-Series, CH-Series, CF-Series, CR-Series, CS-Series.

TITANIUM BASES CAD/CAM FOR CROWN AND BRIDGE RESTORATIONS CAD/CAM PROSTHETICS ON CAMLOG AND CONELOG IMPLANTS

Osteotome inserts kit, angled. Impression tube (open tray) Selection abutment kit / Selection measurement post. Bar base PMMA & Finisher

NARROW DIAMETER implant

NEW NEW. An Extended Solution for Narrow Ridges

Straight Octagon Abutment for Tissue Level Implant

MICRODENT EXTERNAL CONNECTION PRODUCTS GUIDE EXTERNAL CONNECTION IMPLANTS IMPLANTOLOGY SYSTEMS. Product presentation. Digital information

SuperLine & Implantium Surgical / Prosthesis Manual

INSTRUCTIONS FOR USE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment

screw-retained crown using a PEEK temporary abutment

isy indications and techniques

SwishPlant. SwishPlant System Catalog. 4.8mmD mmD. 4.8mmD mmD. 3.7mmD mmD. 6.5mmD

TRI-TAPERED Implant System

N-SERIES. compatible to: Straumann / SynOcta 32 NT-TRADING CATALOGUE PLATFORM 3,5 mm NN 4,8 mm RN 6,5 mm WN TITANIUM BASE SCAN BODY 3D-GUIDE

Prosthodontic Procedure

synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions

SOLUTIONS. DentalWiz. extending the art of Simplantology, to your CAD /CAM restoration jobs, making it as simple as our implant systems.

A self-tapping internal hex. implant by MAKE IT SIMPLE

simply simply digital simply crown & bridge simply removable simply fixed simply à la carte

screw-retained crown using the Laser-Lok Easy Ti temp abutment

DECLARATION OF CONFORMITY To Council Directive 93/42/EEC of 14 June 1993

QZ-Implant TRINON. Bone level implant with hexagonal internal cone connection

GmbH DENTAL IMPLANT SYSTEMS PRODUCT CATALOG

The Multi-unit Abutments of the CE-Series are indicated for Nobel Biocare / NobelReplace Tapered. The current implant diameters have to be attended.

Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l

IOS & The Sirona Connect System Clinician Procedure

internal Impression Technique Guide Internal Implant System

Part 2: Internal Tri-Channel Connection. Nobel Biocare Compatible Components. Tri-Channel Internal Connection Implants

TABLE OF CONTENTS P. 4-5 P. 6-7 P. 8-9 P P P P

NEW. An Extended Solution. for Narrow Ridges

Legacy TM. System Catalog. Legacy TM 1 Legacy TM 2 Legacy TM 3 Legacy TM 4

Type 1. Type 2. Straumann Bone Level. The L-Series abutments are compatible with» L-SERIES «

Guided surgery manual

Type 1. Type 2. Straumann Tissue Level. The N-Series abutments are compatible with» N-SERIES «

contents the smarter case approach reasons to choose simplyintegrated 5 system overview 6 ordering 7 mount-free implants 8-9

INTRODUCTION. Why Choose Cortex Prosthetics?

TRI + Digital Solutions 3SHAPE MANUAL

cement-retained crown using the Laser-Lok Easy Ti temp abutment and PEEK plastic sleeves

Straumann synocta Prosthetic System Basic Information. Technical Information

surgical and prosthetic options & impression technique overview

CROWN AND BRIDGE RESTORATIONS WITH THE SYNOCTA PROSTHETIC SYSTEM

Locator retained mandibular complete prosthesis (isy Implant System)

SuperLine & Implantium Surgical / Prosthesis Manual

Hex-Lock Abutment System. Restorative Manual

Implant And Abutment Level Impressions

TRI + Digital Solutions EXOCAD MANUAL

Multi-unit abutment closed tray technique using the indirect transfer coping

NobelReplace Conical Connection Product overview

» Prosthetic Options by MEDENTiKA «

R-SERIES. compatible to: Zimmer Dental / Tapered Screw-Vent 36 NT-TRADING CATALOGUE PLATFORM 3,5 mm 4,5 mm 5,7 mm TITANIUM BASE

T-SERIES. compatible to: DENTSPLY Implants / Xive. PLATFORM 3,4 mm 3,8 mm 4,5 mm 5,5 mm TITANIUM BASE SCAN BODY 3D-GUIDE LAB ANALOG IMPLANT PICK-UP

internal impression quick reference guide

Implant System MAKE IT SIMPLE

NEW. An Extended Solution. for Narrow Ridges

Advanced individual solutions for esthetic prosthetics. new

Ankylos. Acuris conometric concept. Manual and product catalog

- RESTORATIVE PRODUCT CATALOG

a perfect fit INSTRUCTION MANUAL CAMLOG TORQUE WRENCH WITH CONTINUOUS TORQUE ADJUSTMENT Handling Sterilization Care

Smarter Thinking. Simpler Design. TiLobe Prosthetic Manual for PrimaConnex & Genesis implants

Prosthodontic Procedure

For the oral rehabilitation

Personal Attention Accurate Dental Solutions. Precision Down to the Smallest Detail. Wide Range of Dental Solutions Engineerd for a Lifetime

Leading material offering and application range. Straumann CARES CADCAM

Restorative Manual July 2017

IQ IMPLANTS Smart Choice PRODUCT C ATA L O G

Multi-unit abutment open tray technique using the direct pick-up coping

For technical assistance: Tel Working time: 8.30 am pm

Transcription:

User Manual Complete Prosthetic Kit (CPK)

The Complete Prosthetic Kit is designed to enable easy impression and transfer technique and to prevent the need to remove and to re-tighten the abutments. Advantages at a glance. A selection of lengths, diameters and gingival heights. Compatible with crowns or bridges restorations. Can be used immediately after implantation. Offers improved tissue healing.

Combination. The Complete Prosthetic Kit contains all the necessary components for the dentist to take an impression after implant placement, as well as all the components required for the technician for the fabrication of crowns and bridges. Precision. The Complete Prosthetic Kit ensures an accurate fit for the impression procedure and the restorative process. Kit. The Complete Prosthetic Kit enables a simple restorative process by offering four vertical heights of narrow, standard or wide platforms, without any necessary adjustments or additional components.

Kit contents.

Anatomic transgingival abutment with screw - Gingival height: 1, 2, 3, 4mm - Crown height for Standard/ Wide platform: 4, 6, 8mm - Crown height for Narrow platform: 4, 6mm Burn out anti-rotation plastic cap

Burn out plastic cap Abutment analog - Crown height for Standard/Wide platform: 4, 6, 8mm - Crown height for Narrow platform: 4, 6mm Plastic healing cap - Crown height for Standard/Wide platform: 4, 6, 8mm - Crown height for Narrow platform: 4, 6mm Mount transfer plastic cap

Catalog number index. XX-XPK XX Kit Complete Prosthetic Kit Crown height (4,6,8mm) Gingival height (1,2,3,4mm)

Operating Procedure Steps. 1 Assemble the CPK abutment on the implant. Recommended tightening moment: 30-35 Ncm. Internal Hexagon Connection

External Hexagon Connection

2. Insert the impression coping plastic cap on the CPK abutment. The hatch on the top of the plastic transfer indicates the location of the flat area (anti-rotation).

2A Snap engagement. Indicates the right location of the impression coping plastic cap on the abutment.

3 Take the impression. Recommended impression material: silicone over 20- shore hardness.

4 Place the temporary healing cap on top of the abutment, to allow soft tissue healing. Use temporary glue. Optional procedure: Take out the abutment and place a titanium healing cap according to tissue thickness.

Operating procedure: In the laboratory 5 Insert the abutment analog into the plastic cap (in the impression tray). Verify that the analog fits properly.

6 Place the wax-up anti-rotation plastic cap on the abutment analog. Cut the plastic cap according to analog height. For bridge reconstruction cases, use the white burn out plastic cap without the flat area.

7 The plastic copings for CPK abutment are fitted thanks to a snap mechanism on the plastic that is sited on the analog abutment. This allows the abutment to be perfectly positioned and fixed on the analog. However, once the coping has been cast, it is essential to remove excess material using the MT-CS450 reamer shoulders before placing the abutment on the analog.

W W W. M I S - I M P L A N T S. C O M

Instrument maintenance. Steam sterilization: Insert the cleaned and disinfected abutment in a single-use medical grade sterilization pouch.steam sterilize by autoclave,using either one of the following recommended conditions: Cycle type Temperature Exposure time (min.) Drying time (min.) Gravity displacement 135 C / 275 F 10 minutes 30 minutes Pre-vacuum 132 C / 270 F 4 minutes 30 minutes

The CPK is not intended for use with crowns cast directly onto the abutment analog, such as a CAD/CAM or Captek process. When using such a process, work directly off the CPK abutment. All parts of the Complete Prosthetic Kits are supplied non-sterile. The plastic components are for single use only. Key to codes used: Attention, see instructions for use Catalogue Number Manufacturer Batch Code Single use

EC REP MIS Implants Technologies Ltd. P.O.Box 7, Bar Lev Industrial Park 2015600, ISRAEL Website: www.mis-implants.com MIS Implants Technologies GmbH Simeonscarre 2, 32423 Minden, Germany Tel: +49 571-972-7620 Email: service@mis-implants.de MIS Corporation. All rights reserved. MP-UI029 Rev. 6.1, Apr 2015