Comprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids

Similar documents
Vitamin D3 and related compounds by ESI and APCI

Determination of Amantadine Residues in Chicken by LCMS-8040

High Throughput simultaneous analysis of 39 amino acids in various foods without derivatization using LC-MS/MS

Simultaneous Analysis of Active Pharmaceutical Ingredients and Their Counter-Ions Using a Mixed-Mode Column

Phospholipid characterization by a TQ-MS data based identification scheme

Ultra High Performance Liquid Chromatograph. Nexera X2 C196-E079

Integration of steroids analysis in serum using LC-MS/MS with full-automated sample preparation

Quantitative analysis of hydrophilic metabolite using ion-paring chromatography with a high-speed triple quadrupole mass spectrometer

Characterization of products formed by forced degradation of Etodoalc using LC/MS/MS

Designer Cannabinoids

Quantitative Analysis of Carbohydrates and Artificial Sweeteners in Food Samples Using GFC- MS with APCI Interface and Post-column Reagent Addition

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

Quantitative Analysis of Opiates in Urine Using RRHT LC/MS/MS. Application. Authors. Introduction. Abstract. Forensics

Glycerolipid Analysis. LC/MS/MS Analytical Services

SUPPORTING INFORMATION FOR: CONCENTRATIONS OF POLYBROMINATED DIPHENYL ETHERS, HEXABROMOCYCLODODECANES AND TETRABROMOBISPHENOL-A IN BREAST MILK FROM

Fully Automated Online Sample Preparation AND Quantification of Amiodarone from Whole Blood using CLAM-LC-MS/MS

Automated Purification and Analytical Reinjection of a Small Molecule Drug, Probenecid, on a Gilson LC/MS Dual Function System

Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices

2D-LC as an Automated Desalting Tool for MSD Analysis

Method Development for the Analysis of Endogenous Steroids Using Convergence Chromatography with Mass Spectrometric Detection

Liquid Chromatograph Mass Spectrometer LCMS-8040 C146-E188E

Rapid Lipid Profiling of Serum by Reverse Phase UPLC-Tandem Quadrupole MS

Rapid, Simple Impurity Characterization with the Xevo TQ Mass Spectrometer

Identification & Confirmation of Structurally Related Degradation Products of Simvastatin

Target and Non-target Analysis of Metabolites in Urine Using Scan/MRM and GC/MS/MS

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

Tentu Nageswara Rao et al. / Int. Res J Pharm. App Sci., 2012; 2(4): 35-40

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP

ACQUITY UPLC WITH PDA DETECTION: DETERMINING THE SENSITIVITY LIMITS OF OXYBUTYNIN AND RELATED COMPOUNDS

Comparison of a UPLC Method across Multiple UHPLC Systems

Journal of Chemical and Pharmaceutical Research

LC/MS/MS SOLUTIONS FOR LIPIDOMICS. Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Identification of Steroids in Water by Ion Trap LC/MS/MS Application

Impact of Chromatography on Lipid Profiling of Liver Tissue Extracts

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

LC/MS Analysis of Various Hydrophilic Compounds Using a Polymer-Based Amino Column - Shodex TM HILICpak TM VG-50 2D

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

Abstract. Introduction

Fully automated sensitive determination of immunosuppressant drugs in whole blood, using high quality internal standardization

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

SUPPLEMENTARY DATA. Materials and Methods

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis

Agilent 6410 Triple Quadrupole LC/MS. Sensitivity, Reliability, Value

LCMS-8030 Application Report. Steroids: Testosterone, Progesterone, Estradiol, Ethinylestradiol

N-terminal charge-driven de novo sequencing by using ASDF-incorporated Curved Field Reflectron

PTM Discovery Method for Automated Identification and Sequencing of Phosphopeptides Using the Q TRAP LC/MS/MS System

Analysis and Quantitation of Cocaine on Currency Using GC-MS/MS. No. GCMS No. SSI-GCMS-1501

A Definitive Lipidomics Workflow for Human Plasma Utilizing Off-line Enrichment and Class Specific Separation of Phospholipids

Edgar Naegele. Abstract

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

Agilent 7700x ICP-MS

Characterization of an Unknown Compound Using the LTQ Orbitrap

Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

A Novel Platform of On-line Sample Pre-treatment and LC/MS/MS Analysis for Screening and Quantitation of Illicit Drugs in Urine

Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system

Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column

Development and Validation of a Simultaneous HPLC Method for Quantification of Amlodipine Besylate and Metoprolol Tartrate in Tablets

International Journal of Pharma and Bio Sciences DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR THE ESTIMATION OF STRONTIUM RANELATE IN SACHET

Extraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis

CHAPTER 8 HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC) ANALYSIS OF PHYTOCHEMICAL CONSTITUENTS OF M. ROXBURGHIANUS AND P. FRATERNUS PLANT EXTRACTS

LCMS-8050 Drugs of Abuse: 113 Analytes with Polarity Switching

DETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS

Supporting Information

Ankit et al Journal of Drug Delivery & Therapeutics; 2013, 3(2), Available online at RESEARCH ARTICLE

IJPAR Vol.3 Issue 4 Oct-Dec-2014 Journal Home page:

CONTENT. i iv ix. SVKM s NMIMS, School of Pharmacy and Technology Management

METHOD DEVELOPMENT AND VALIDATION BY RP-HPLC FOR ESTIMATION OF ZOLPIDEM TARTARATE

Extraction of a Comprehensive Steroid Panel from Human Serum Using ISOLUTE. SLE+ Prior to LC/MS-MS Analysis

PHOTOCATALYTIC DECONTAMINATION OF CHLORANTRANILIPROLE RESIDUES IN WATER USING ZnO NANOPARTICLES. DR. A. RAMESH, Ph.D, D.Sc.,

Improving Selectivity in Quantitative Analysis Using MS 3 on a Hybrid Quadrupole-Linear Ion Trap Mass Spectrometer

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis

Simultaneous estimation of Metformin HCl and Sitagliptin in drug substance and drug products by RP-HPLC method

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system

Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS

Available online at Scholars Research Library

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

Pankti M. Shah et al, Asian Journal of Pharmaceutical Technology & Innovation, 04 (17); 2016; 07-16

Matrix Factor Determination with the Waters Regulated Bioanalysis System Solution

Polymer Additive Analysis by EI and APCI

Using Software Tools to Improve the Detection of Impurities by LC/MS. Application Note. Christine Miller Agilent Technologies.

F. Al-Rimawi* Faculty of Science and Technology, Al-Quds University, P.O. Box 20002, East Jerusalem. Abstract

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages

Qualitative and quantitative determination of phenolic antioxidant compounds in red wine and fruit juice with the Agilent 1290 Infinity 2D-LC Solution

LC-MS Analysis of Amino Acids on a Novel Mixed-Mode HPLC Column

Development of a Bioanalytical Method for Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

Identification of Ginsenosides Using the SCIEX X500R QTOF System

Fast Separation of Triacylglycerols in Oils using UltraPerformance Convergence Chromatography (UPC 2 )

Application Note. Abstract. Authors. Pharmaceutical

Quantitation of Protein Phosphorylation Using Multiple Reaction Monitoring

Analysis of Cholesterol-Lowering Drugs (Statins) Using Dried Matrix Spot Technology

LC-MS/MS Method for the Determination of Tenofovir from Plasma

Application Note LCMS-108 Quantitation of benzodiazepines and Z-drugs in serum with the EVOQ TM LC triple quadrupole mass spectrometer

Analysis of Pesticides (II) Metribuzin & their metabolites in Rice Jun Yonekubo, Nihon Waters, JAPAN

A Validated Chiral Liquid Chromatographic Method for The Enantiomeric Separation of Dapoxetine Hydrochloride

Transcription:

PO-CON1576E Comprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids HPLC 2015 PSB-MULTI-06 Yoshiyuki WATABE, Tetsuo IIDA, Daisuke NAKAYAMA, Kanya TSUJII, Saki UEDA, Tadayuki YAMAGUCHI, Junichi MASUDA, Yoshihiro HAYAKAWA Shimadzu Corporation, Kyoto, Japan

Introduction Kakkonto, traditional Chinese drug, is believed to be effective against cold, headache, stiff shoulders, etc. It consists of natural plants and contains many compounds such as ephedrine, glycyrrhizic acid, and cinnamic acid. Nexera-e, comprehensive two-dimensional liquid chromatograph, is useful to separate such a complex matrix. In general, different separation modes are selected for 1st and 2nd dimensions for comprehensive two-dimensional chromatography to obtain high resolution that can not be achieved by each individual separation mode. We tried comprehensive separation using a semi-micro reversed-phase column and neutral ph mobile phase for 1st dimension and an ultra-high speed reversed phase column and acidic ph mobile phase for 2nd dimension. Herbal medicine contains many relatively polar compounds, so ph is an important parameter to modify separation selectivity. We performed differential analysis for commercial Kakkonto products and determined glycyrrhizic acid contained with photodiode array detector (PDA). In lipidomics, phospholipids are the attractive targets of LC/MS analysis since lipids are important and essential components of biological membranes. However, conventional HPLC system by a single separation mode performs poorly on biological lipid sample, because it contains various kinds of lipids with common moieties that govern their behavior on column. Nexera-e was capable of characterizing phospholipids both quantitatively and qualitatively when coupled with triple quadrupole and iontrap-tof type of mass spectrometer (MS/MS and IT-TOF) respectively. Reliable identification of lipid species was performed by acquiring m/z values of related parent and fragment ions at high accuracy with the IT-TOF and matching the data to commercially available data-base. Experimental 1 st dimension column Loop A 2 nd dimension column PDA MS Auto sampler 1 st dimension pumps Loop B 2 nd dimension pumps Fig.1 Flow line diagram of Nexera-e 2

Kakkonto 1D Column : Shim-pack XR ODSII (100 mm L. x 1.5 mm I.D., 2.2 µm) Mobile Phase : A; 10 mmol/l (sodium) phosphate buffer ph = 6.8 B; acetonitrile Flow Rate : 0.05 ml/min Time Program : B Conc. 5% (0 min) 30% (70 min) 90% (80 min) 90% (90 min) 50% (90.1 min) STOP (110 min) Column Temp. : 40 C Injection vol. : 2 µl Loop vol. : 50 µl (Modulation time : 60 sec) 2D Column : Kinetex (50 mm L. x 3 mm I.D., 2.6 µm) Mobile Phase : A; 10 mmol/l (sodium) phosphate buffer ph= 2.6 B; acetonitrile Flow Rate : 2 ml/min Time Program : Without Auto-gradient; B Conc. 5% (0 min) 60% (0.75 min) 5%(0.76 min) STOP (1 min) With Auto-gradient; Initial.B Conc. 5% (0 min) 40% (0.75 min) 5%(0.76 min) STOP (1 min) Final.B Conc. 20% (0 min) 60% (0.75 min) 20%(0.76 min) STOP (1 min) The initial and final B conc. has been changed by a stepwise method Detector : SPD-M30A Photo diode array detector (PDA, standard cell 1μL, wavelength = 254 nm) Glycerophospholipids 1D Colum : Nucleosil SIL (150 mm L. X 1.0 mm I.D., 3 µm) Mobile Phase : A; isooctane/acetone/ethyl acetate/acetic acid = 40/20/20/0.03 (v/v/v/v) B; isooctane/2-propanol/water/acetic acid/28% ammonia aq.sol.= 40/51/9/0.03/0.03 (v/v/v/v/v) Flow Rate : 0.02 ml/min Time Program : B Conc. 30% (0 min) 40% (25 min) 100% (40 min) 100% (55 min) 30% (55.1 min) STOP (70 min) Column Temp. : 40 C Injection vol. : 5 µl Loop vol. : 20 µl 2D Column : Phenomenex Kinetex C18 (50 mm L. X 4.6 mm I.D., 2.6 µm) Mobile Phase : A; methanol/water/acetic acid/28% ammonia aq.sol. = 90/10/0.05/0.05 (v/v/v/v) B; 2-propanol/acetic acid/28% ammonium hydroxide = 100/0.05/0.05 (V/V/V) Flow Rate : 3.5 ml/min (50% split for MS) Time Program : B Conc. 10% (0 min) 50% (0.75 min) 10%(0.76 min) STOP (1 min) The initial B conc. has been changed by a stepwise method Detector : Shimadzu LCMS-8050 (MS/MS, ESI positive, MRM mode) Shimadzu LCMS-IT-TOF (IT-TOF, ESI positive/negative scan, m/z :700-800 3

Results Kakkonto (Chinese crude drug): RP RP-PDA Effect of auto gradient function and determination of Glycyrrhzic acid 2D: Constant gradient 2D: Auto-gradient 2D neutral ph UV 254 nm 608.4 μg/l Area Calibration curve Glycyrrhizic acid r 2 =0.9998 1D acidic ph Conc. (μg/l) Compound Total retention time Retention time (2D) Area Glycyrrhizic acid 0.007 0.37 5.4 Fig.2 Comprehensive-2D separation of commercial Kakkonto product with/without Auto gradient program function, linearity of 50-1000 mg/l and repeatability of 5 replicated analyses of real sample Differential analysis between two kakkonto products Enlarged display 3D Plot Product A Product A 2D t R A 0.2 min 0.3 min 10 min 20 min 10 min 15 min 1D t R Product B 2D t R Product B 0.2 min 0.3 min 10 min 20 min 10 min 15 min 1D t R 0.2 min Merged (A and B) Graphical representation of differential analysis enables intuitive recognition of difference in constituent and concentration 10 min 20 min Fig.3 Comparison of comprehensive contour plots of two Kakkonto products Fig.4 Differential analysis between A and B products 4

Glycerophospholipids: NP RP-MS/MS (Whole MRM plots) Quantitative analysis of phosphatidylcholines Area Calibration curve 18:0-18:1 PC r 2 =0.9999 PE UV 2D270 nm PG PI PS PC 18:0p - 18:1 PC 18:0-18:1 PC 16:0-16:0 PC 1D Conc. (μg/l) Compound MRM transition Total retention time Retention time (2D) Blob Area 16:0-16:0 PC m/z 734.6 > 184.1 0.007 0.9 6.8 18:0-18:1 PC m/z 788.6 > 184.1 0.013 1.1 8.9 18:0p-18:1 PC m/z 772.6 > 184.1 0.013 1.2 6.4 Fig.5 Comprehensive separation of phospholipids, linearity of 50-5000 μg/l and repeatability of 5 replicated analyses of 500 μg/l STD solution in %RSD Glycerophospholipids: NP RP IT-TOF (Scan) Qualitative analysis with IT-TOF based on accurate m/z The GPLs mixture was comprised of 50 mg/l of each of PG, PE and PC. The contour plot of ESI- positive/negative scan (m/z 700-800) by LCMS-IT-TOF showed the separation of these compounds. PC compounds were detected more sensitively in ESI positive, whereas PE and PG compounds in negative mode. Then MS 2 analysis to identify 16:0-20:4 PG was performed. Obtained data from both MS and MS/MS were contributed to automatic lipid identification using the data-base matching software Lipid search that compares the experimental and theoretical m/z values of both parent and fragment ions and it successfully indicated 16:0-20:4 PG as the most expecting candidate. Additionally, MS2 fragment peak assignations supported the identification of 16:0-20:4 PG. MS/MS spectrum 2D:RP 18:0p-18:1 PE 16:0-18:1 PG 16:0-20:4 PG Positive scan mode 18:0-22:6 PE 16:0-20:4 PE 16:1-16:1 PC 1D:NP 2D:RP Negative scan mode 18:0p-18:1 PE 16:0-18:1 PG 16:0-20:4 PG 18:0-22:6 PE 16:0-20:4 PE 16:0e-18:1 PC Assigned fragment peaks in MS/MS spectrum 1D:NP Fig.6 Contour plot of positive/negative scan mode and lipid identification analysis using the data-base matching software 5

Conclusion 1. Novel comprehensive two-dimensional LC Nexera-e was successfully applied to quantitative, qualitative and differential analyses of complex samples. 2. PDA, MS/MS and IT-TOF detection system could go with comprehensive two-dimensional separation with satisfactory sensitivity and ruggedness. 3. Combination use of different separation modes afforded sufficiently orthogonal separation of Chinese crude drug and phospholipids. 4. Excellent repeatability, linearity of blob area as well as repeatability of total retention time by Nexera-e -MS/MS or PDA setup were confirmed. 5. Reliable identification of target lipid in 2D contour plot was achieved by data-base matching analysis based on high resolution IT-TOF data. First Edition: June, 2015 www.shimadzu.com/an/ For Research Use Only. Not for use in diagnostic procedures. The content of this publication shall not be reproduced, altered or sold for any commercial purpose without the written approval of Shimadzu. The information contained herein is provided to you "as is" without warranty of any kind including without limitation warranties as to its accuracy or completeness. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. This publication is based upon the information available to Shimadzu on or before the date of publication, and subject to change without notice. Shimadzu Corporation, 2015