Torsion bottle, a very simple, reliable, and cheap tool for a basic scoliosis screening

Similar documents
A controlled prospective study on the efficacy of SEAS.02 exercises in preventing progression and bracing in mild idiopathic scoliosis

Dr. Theodoros B Grivas MD, PhD

Current knowledge of scoliosis in physiotherapy students trained in the United Kingdom

Hagit Berdishevsky. The Author(s) Scoliosis and Spinal Disorders 2016, 11(Suppl 2):40 DOI /s

Idiopathic scoliosis Thriasio General Hospital

Lars Jacobsson 1,2,3* and Jan Lexell 1,3,4

Demonstration of active Side Shift Type1(Mirror Image ) in Right (Major) Thoracic curve.

Takashi Yagisawa 1,2*, Makiko Mieno 1,3, Norio Yoshimura 1,4, Kenji Yuzawa 1,5 and Shiro Takahara 1,6

The Sforzesco brace and SPoRT concept: A brace to replace cast in worst curves

Non-invasive quantitative assessment of scoliosis spinal surgery outcome Lama Seoud* a, Farida Cheriet a,b, Hubert Labelle b, Stefan Parent b

SPINAL SCREENING TRAINING

Improvement of curvature and deformity in a sample of patients with Idiopathic Scoliosis with specific exercises

Computer-aided King classification of scoliosis

Exercises for Scoliosis within the braces and Brace modifications for exercises

The Adaptive Patterns of Pelvic Alignment in Individuals with Adolescent Idiopathic Scoliosis

Corrective exercises in the treatment of Scoliosis. Nikos Karavidas, MSc, PT

Effectiveness of the Rigo Chêneau versus Boston-style orthoses for adolescent idiopathic scoliosis: a retrospective study

Effectiveness of the surgical torque limiter: a model comparing drill- and hand-based screw insertion into locking plates

Rasterstereographic analysis of axial back surface rotation in standing versus forward bending posture in idiopathic scoliosis

Can bracing help adults with chronic back pain and scoliosis? Short-term results from a pilot study

CT findings in patients with Cabazitaxel induced pelvic pain and haematuria: a case series

Eur Spine 2012 Mar;21 指導老師 : 譚仕馨主任 報告人 : 連煜

Barbara Plewka 1, Marcin Sibiński 2, Marek Synder 2, Dariusz Witoński 3, Katarzyna Kołodziejczyk-Klimek 1, Michał Plewka 4 ONLY

Scoliosis Short-Term Rehabilitation (SSTR) A Pilot Investigation

Cindy L. Marti 1, Steven D. Glassman 2,3, Patrick T. Knott 4, Leah Y. Carreon 3* and Michael T. Hresko 5

Scoliosis is a complex deformity of the spine that develops

Evaluation of an apparatus to be combined with a smartphone for the early detection of spinal deformities

Sabrina Donzelli 1*, Fabio Zaina 1, Monia Lusini 1, Salvatore Minnella 1 and Stefano Negrini 2,3

Effect of One-period of SEAS exercises on Some Spinal Biomechanical and Postural Parameters in the Students with Idiopathic Scoliosis

Adolescent Idiopathic Scoliosis

Is There Evidence for Non- Surgical Interventions other than Bracing and Scoliosis- Specific Exercises?

Can surface topography replace radiography in the management of patients with scoliosis?

Measurement of fatigue in paraspinal muscles while performing a modified side plank in patients with Adolescent Idiopathic Scoliosis

Debate: School Screening for Scoliosis is Reasonable

F.I.T.S. Method. Functional Individual Therapy of Scoliosis. Marianna Białek PT, MSc., PhD. (POLAND) Andrzej M hango PT, MSc.,D.O.

Ligation of lymph vessels for the treatment of recurrent inguinal lymphoceles following lymphadenectomy

Upper extremity open fractures in hospitalized road traffic accident patients: adult versus pediatric cases

Unilateral lateral rectus muscle advancement surgery based on one-fourth of the angle of consecutive esotropia

18th International Scientific Meeting of the VCFS Educational Foundation Steven M. Reich, MD. July 15-17, 2011 New Brunswick, New Jersey USA

Scoliosis and Deformity Screening

Pre-operative Computed Tomographic(CT) Scan Templating in Adolescent Idiopathic Scoliosis(AIS): Is it Really Necessary

Bracing Effects of the Flexpine in Scoliosis Patients

ApiFix New minimal invasive method to treat Adolescent Idiopathic Scoliosis Short fixation followed by Specific Physiotherapy Program

Does serum CA125 have clinical value for follow-up monitoring of postoperative patients with epithelial ovarian cancer? Results of a 12-year study

Materials and Methods

Trends of kidney transplantation in Japan in 2018: data from the kidney transplant registry

Example of a Systematic Review and its application to practice

Author s response to reviews

Conference presentation to publication: a retrospective study evaluating quality of abstracts and journal articles in medical education research

Scoliosis. About idiopathic scoliosis and its treatment. Patient and Family Education. What types of scoliosis are there?

Ultrasound-assisted brace casting for adolescent idiopathic scoliosis, IRSSD Best research paper 2014

A Patient s Guide to Scoliosis

The Open Orthopaedics Journal

Evaluating Diagnostic Procedures. Einas Al-Eisa, MSc, PhD

Grading of Vertebral Rotation

Truncal changes in children with mild limb length inequality: a surface topography study

Comparison of in-and outpatients protocols for providence night time only bracing in AIS patients compliance and satisfaction

How to use: Hold the Baseline scoliosis. Fabrication Enterprises Incorporated

From 12th International Conference on Conservative Management of Spinal Deformities - SOSORT 2015 Annual Meeting Katowice, Poland.

Gregory M Yoshida, MD. Lateral curvature of the spine in the coronal plane > 10 degrees on an upright film

Association between Sacral Slanting and Adjacent Structures in Patients with Adolescent Idiopathic Scoliosis

OMT to Reduce (Idiopathic) Scoliotic Curves

Scoliosis is measured in anteroposterior/ posteroanterior

Use of the iphone for Cobb angle measurement in scoliosis

Skin marker placement by technologist prior to knee MRI helps identify clinically relevant pathologies

SpineScan Instructions for Use

Debate: School Screening for Scoliosis Should be Abandoned

A rare case of osteoblastoma combined with severe scoliosis deformity, coronal and sagittal imbalance

SCOLIOSIS SCHOOL SCREENING

Pregabalin prescription for terminally ill cancer patients receiving specialist palliative care in an acute hospital

Lyon bracing in adolescent females with thoracic idiopathic scoliosis: a prospective study based on SRS and SOSORT criteria

A Systematic Literature Review of Nonsurgical Treatment in Adult Scoliosis

Learning curve in 20 years of brace treatment F. Landauer

Measurement of scoliosis Cobb angle by end vertebra tilt angle method

Understanding test accuracy research: a test consequence graphic

New Tests for Early Screening of the So Called Idiopathic Scoliosis

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Case report. Open Access. Abstract

Clinical audit for occupational therapy intervention for children with autism spectrum disorder: sampling steps and sample size calculation

Can the Ileocecal Valve Point Predict Low Back Pain Using Manual Muscle Testing?

Spinal Fusion. North American Spine Society Public Education Series

What Are the Best Exercises for Scoliosis? Lise Stolze Polestar Educator, Physical Therapist, and certified C2 Schroth Scoliosis Therapist

New classification of lunate fossa fractures of the distal radius

The Scoliosis Research Society-22 questionnaire adapted for adolescent idiopathic scoliosis patients in China: reliability and validity analysis

State of the art of current 3-D scoliosis classifications: a systematic review from a clinical perspective

Reliability of Measuring Trunk Motions in Centimeters

Running head: Understanding Scoliosis 1. Understanding Scoliosis

The development of a decision making pathway for the Physiotherapy treatment of Adult scoliosis Betts, Tony (Royal National Orthopaedic Hospital,

Guided Exercise for the Treatment of Scoliosis COPYRIGHT U.S. SPINE AND SPORT 1

The spine has 3 slight curves: Neck Upper back Lower back

Idiopathic scoliosis Scoliosis Deformities I 06

The effectiveness of combined bracing and exercise in adolescent idiopathic scoliosis based on SRS and SOSORT criteria: a prospective study

Freih Odeh Abu Hassan

Study of Posterior Trunk Surface Changes by Age and Sex Using Moiré Topography

School -based screening for scoliosis: is it cost-effective?

A hemodialysis cohort study of protocolbased anticoagulation management

Health-related quality of life and physical self-concept of adolescents with idiopathic scoliosis during brace wearing

Reliability and concurrent validity of postural asymmetry measurement in adolescent idiopathic scoliosis

Transcription:

Romano and Mastrantonio Scoliosis and Spinal Disorders (2018) 13:4 DOI 10.1186/s13013-018-0150-6 RESEARCH Open Access Torsion bottle, a very simple, reliable, and cheap tool for a basic scoliosis screening Michele Romano * and Matteo Mastrantonio Abstract Background: One of the reasons that make scoliosis a disease that scares so much the parents is its specific characteristic of being difficult to detect on its onset. The aim of this paper is to check the possible usefulness of a simple tool (the torsion bottle) that has been developed with the aim to offer an instrument for home use by parents but also for screening purposes in the low-income countries. Methods: Study design: retrospective analysis to evaluate intra-operator reliability of the tools and inter-operator repeatability using the torsion bottle. For the first and the second part of the study, 35 subjects were measured. The goal of the first experiment was to evaluate the reliability of the torsion bottle to identify all individuals who experienced a thoracic or lumbar prominence equal or greater than 7. The secondary aim was to verify the reliability of blinded inter-operator assessments, performed with the torsion bottle by two physiotherapists on the same patients. Results: The reliability of the assessments of the torsion bottle has been performed with the Kappa statistic to evaluate the measurement agreement. The results have shown that the intra-operator reliability of the tool is very high between the measurements collected with the scoliometer and those collected with the torsion bottle (kappa = 0.9278; standard error = 0.7094). The data of the second part of the study show that the inter-operator reliability is good (kappa = 0.7988; standard error 0.1368). Conclusion: The collected data showed that the torsion bottle revealed itself as an efficient tool to execute a basic screening to identify the presence of a prominence in a significant group of adolescents. Keywords: Prominence, Scoliometer, Measurement Background One of the reasons that make scoliosis a disease that scares so much the parents is its specific characteristic of being difficult to detect on its onset. Too often, it is possible to recognize the appearance of the spinal curves when the disease is already severe. The reason is due to the typical, slow, and insidious debut of the symptoms. Being able to identify early the first signs of misalignment of the spine is one of the most effective treatment keys. Obviously, a frequent monitoring of the clinical signs of scoliosis is the simplest solution [1 3]. * Correspondence: michele.romano@isico.it ISICO (Italian Scientific Spine Institute), Via Bellarmino 13/1, Milan, Italy One of the most important clinical signs of this disease is the prominence [4]. The presence of the prominence is internationally recognized as an indisputable element of the pathology [5 7]. For the prominence assessment, a scoliometer is usually used [8, 9]. The scoliometer is a professional tool used in the medical field by physicians and physical therapists. Obviously, in a domestic field, the scoliometer is not available. For this reason, a very simple tool called torsion bottle, cheap and easy to create, has been developed. The aim of this paper is to check the possible usefulness of this simple tool (the torsion bottle) that has been The Author(s). 2018 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Romano and Mastrantonio Scoliosis and Spinal Disorders (2018) 13:4 Page 2 of 6 developed with the aim to offer an instrument for home use by parents but also for screening purposes in the low-income countries. Methods Study design: retrospective analysis to evaluate intraoperator reliability of the tool and inter-operator repeatability. The study was divided into two parts. The main aim was to compare the measurements collected with the torsion bottle and the same measurements collected with the scoliometer (gold standard) in a population of patients accessing our clinic for the rehabilitation treatment, measured according to our standard evaluation protocol. The secondary aim was to verify the reliability of blinded inter-operator assessments, performed with the torsion bottle by two physiotherapists on the same patients. These double-blinded measurements were taken periodically for a short time interval in our clinic to verify measurement accuracy in the everyday clinical activities. The tool The torsion bottle is composed of a plastic water bottle of 500 ml. The perfect accuracy of the amount of water to be used is not an essential element. On the outer surface of the bottle, it will be marked with a series of four landmarks that will be essential for its use. These landmarks will be marked only after the bottle is partially emptied and carefully closed. These landmarks will be adjusted only to the particular amount of water contained in that bottle. In any case, it is recommended to fill approximately half of the bottle. The torsion bottle is used in a horizontal position as a scoliometer. Fig. 2 The distances (in mm) between the landmarks The rationale of the preparation of the torsion bottle is the variation of the position of the little quantity of water inside the bottle, when the bottle is tilted. The essential reference signs are: Landmarks 1 and 2 which should coincide with the water surface. Landmark 3 is the limit of the 7 of the bottle s tilt, and it represents the cutoff to identify the subjects with a prominence less, equal, or greater than this value (Fig. 1). Landmark 2 is marked at a distance of 80 mm with respect to landmark 1. Landmark 3 is marked 10 mm from the landmark 2 in the orthogonal direction (Fig. 2). How to use the torsion bottle How to use the torsion bottle is as follows: Forward bending of the patient s trunk to perform an Adam test [10]. The torsion bottle positioned crosswise on the patient s back with the landmark 1 positioned over Fig. 1 The four landmarks marked on the torsion bottle Fig. 3 Use of the torsion bottle. Positioning of the tool

Romano and Mastrantonio Scoliosis and Spinal Disorders (2018) 13:4 Page 3 of 6 Fig. 4 Tilt of the torsion bottle toward the concavity of the curve Fig. 6 Check of the position of the water surface respect the landmark number 3 the line of bony prominences and the water surface coinciding with landmarks 1 and 2 (Fig. 3). Tilt the bottle until it touches the patient s back (Fig. 4). Rotate the bottle until the surface of the water coincides with the position of landmark 1 (Fig. 5). Observe the position of the surface of the water with respect to landmarks 3 or 4 (Fig. 6). Instructions for the preparation and the use of the torsion bottle https://drive.google.com/file/d/0b2u_asmuxo0_bj- BiQ0ptTUl5M3M/view?ts=57d16f0e. The water surface slope, with respect to the reference point, corresponds precisely to 7125. The following table shows the variability linked to the potential errors in the mark of the reference points (Table 1). For the first part of the study, 35 subjects were measured. This group included consecutive adolescents of both genders who attend a specialized clinic for the conservative treatment of scoliosis to perform their medical examinations. The goal of the experiment was to evaluate the reliability of the torsion bottle to identify all individuals who experienced a prominence equal or greater than 7. Fig. 5 Rotation of the torsion bottle and realignment of the water surface with the landmark number 1 The presence of a prominence higher than 7 is considered a clinical sign very likely linked to a scoliosis that requires a medical treatment [1]. The assessment was performed by the same evaluator. The evaluator asked the patient to bend the trunk forwards to perform an Adam test. As a first action, he performed the measurement with the torsion bottle, and in a second time, the Table 1 Distances between reference points and relative degrees Dots 1-2 (cm) Dots 2-3 (cm) Degree 8 1 7,125 8 0,7 5,001 8 0,8 5,711 8 0,9 6,419 7,9 0,7 5,064 7,9 0,8 5,782 7,9 0,9 6,499 7,8 0,7 5,128 7,8 0,8 5,856 7,8 0,9 6,582 7,7 0,7 5,194 7,7 0,8 5,932 7,7 0,9 6,667 8,1 0,7 4,939 8,1 0,8 5,641 8,1 0,9 6,340 8,2 0,7 4,879 8,2 0,8 5,572 8,2 0,9 6,263 8,3 0,7 4,821 8,3 0,8 5,505 8,3 0,9 6,189 8 1,2 8,531

Romano and Mastrantonio Scoliosis and Spinal Disorders (2018) 13:4 Page 4 of 6 measurement with the scoliometer precisely performed on the same point of the trunk. For the second part of the study, the assessors measured the prominences of 35 consecutive patients who attended the same clinic for a session of conservative treatment based on Physioterapic Scoliosis Specific Exercises (PSSE). Measurements were collected blinded by two physiotherapists and processed by a third operator. The first assessor performed the first evaluation. The evaluator asked the patient to bend the trunk forwards to perform an Adam test. The assessor used the torsion bottle to measure the prominence. The evaluator made a small sign at the back where the measurement had been taken, to enable the second prominence assessment on the same spot (Fig. 7). The subject was accompanied to another room to carry out a second evaluation performed by the second evaluator. The data collected in two different files have been handed over to a third operator who performed the comparison and the statistical tests. Results The following table shows the detail of the measurements taken for the first part of the study (Table 2): Column 1: gender of the subject Column 2: the result of the measurement performed with the torsion bottle and the positive or negative hypothesis of the presence of a prominence equal to or greater than 7 Column 3: the measurement of the angle trunk rotation performed with the scoliometer Fig. 7 Landmark on the prominence to made the measure on the same point Column 4: the agreement of the measurement performed with the torsion bottle and the scoliometer Table 3 shows the details of the measurements of the second part of the study: Column 1: gender of the subject Table 2 Concordance between Torsion Bottle and Scoliometer assessments Gender Torsion Bottle Assessment Scoliometer Concordance Assessment Female Positive 13 YES Female Positive 11 YES Male Negative 3 YES Female Positive 11 YES Female Negative 3 YES Female Negative 8 NO Female Positive 9 YES Male Positive 12 YES Male Positive 9 YES Female Negative 4 YES Male Negative 6 YES Female Negative 6 YES Female Positive 11 YES

Romano and Mastrantonio Scoliosis and Spinal Disorders (2018) 13:4 Page 5 of 6 Table 3 Agreement between Torsion Bottle assessment performed by blinded assessors Gender Assessor 1 Assessorr 2 Female Negative Negative Male Positive Positive Male Negative Negative Male Positive Positive Male Positive Negative Female Negative Negative Male Negative Negative Female Negative Positive Female Negative Negative Column 2: results of the first assessor Column 3: results of the second assessor The reliability of the assessments of the torsion bottle has been performed with the Kappa statistic to evaluate the measurement agreement. The results have shown that the intra-operator reliability of the tool is very high between the measurements collected with the scoliometer and those collected with the torsion bottle (kappa = 0.9278; standard error = 0.7094). The data of the second part of the study show that the inter-operator reliability is good (kappa = 0.7988; standard error 0.1368). Discussion The collected data showed that the torsion bottle revealed itself as an efficient tool to execute a basic screening to identify the presence of a prominence in a significant group of adolescents. The basic scoliosis screening is a very simple process but is not performed regularly because, in many countries, the health policy of this disease is based on the concept of wait and see. Unfortunately, this does not help in prevention but too often leads to surgical intervention, when the severity of the disease is serious. This torsion bottle has not been conceived for a professional use because the torsion bottle does not quantify the degree of the prominence, unlike the scoliometer. It is considered more useful for a domestic use after having trained the parents. This makes it possible to achieve greater awareness and more frequent monitoring in situations of young patients at risk of evolution. Conclusion The torsion bottle is useful to perform a pre-investigation of the presence of a prominence, permitting a simplified assessment of its value thus directing to a specialist for a medical assessment. Another use of the torsion bottle may be provided for screening to be carried out in countries where due to the low-income problems it is difficult to find a scoliometer or where the presence of health professionals is not so widely distributed. The water plastic bottles do not have the same shape in all countries. In some countries, it is typical to find this small bottle with a hollow in the upper part (Fig. 1). This hollow is useful because it avoids a contact with the bony prominences of the spinous processes. When such a tool is not available and it is necessary to use a bottle with a straight profile, it is important to pay attention to the spinous processes to avoid that the contact with the bottle falses the measurement. Acknowledgements Not applicable Funding No funding was received. Availability of data and materials Please contact the author for data requests. Motivation for the publication This paper deserves to be published for a variety of reasons. A very basic tool for assessing the presence of a prominence has been experimented. The

Romano and Mastrantonio Scoliosis and Spinal Disorders (2018) 13:4 Page 6 of 6 prominence is one of the most important clinical signs for the identification of a scoliosis. This data allows to do an objective screening and monitoring of the evolution of the prominence even in a familiar habit and the use of an objective evaluation tool in countries where the gold standard instrument is unavailable. Authors contributions MR performed the paper design and wrote and revised the manuscript. He is the author of the pictures. MM revised the manuscript. Both authors read and approved the final manuscript. Ethics approval and consent to participate Ethical approval was obtained from Comitato Etico-Milano-Area B with an approval reference: 20,121,528. Consent for publication We have obtained consent to publish from the legal parent of all the participants with individual patient data. Competing interests Michele Romano is the stockholder of ISICO (Italian Scoliosis Spine Institute). The other author declares that he has no competing interests. Publisher s Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations. Received: 26 October 2017 Accepted: 3 January 2018 References 1. Negrini S, et al. 2011 SOSORT guidelines: orthopaedic and rehabilitation treatment of idiopathic scoliosis during growth. Scoliosis. 2012;7:3. https://doi.org/10.1186/1748-7161-7-3. 2. Weiss H, et al. Indications for conservative management of scoliosis (guidelines). Scoliosis. 2006;1(1):5. 3. Negrini S, et al. Italian guidelines on rehabilitation treatment of adolescents with scoliosis or other spinal deformities. Eura Medicophys. 2005;41(2):183 201. 4. Zaina F, et al. Clinical evaluation of scoliosis during growth: description and reliability. Stud Health Technol Inform. 2008;135:125 38. 5. Parent EC, et al. Identifying the best surface topography parameters for detecting idiopathic scoliosis curve progression. Stud Health Technol Inform. 2010;158:78 82. 6. Aulisa AG, et al. Correlation between hump dimensions and curve severity in idiopathic scoliosis before and after conservative treatment Spine (Phila Pa 1976). 2018;43(2):114-119. 7. Ferraro C, et al. Hump height in idiopathic scoliosis measured using a humpmeter in growing subjects: relationship between the hump height and the Cobb angle and the effect of age on the hump height. Eur J Phys Rehabil Med. 2017;53(3):377-389. 8. Amendt LE, et al. Validity and reliability testing of the Scoliometer. Phys Ther. 1990;70(2):108 17. 9. Murrell GA, et al. An assessment of the reliability of the Scoliometer. Spine (Phila Pa 1976). 1993;18(6):709 12. 10. Côté P, Kreitz B, Cassidy JD, Dzus AK, Martel J. A study of the diagnostic accuracy and reliability of the scoliometer and Adam s forward bend test. Spine 1998; 1;23(7):796-802. Submit your next manuscript to BioMed Central and we will help you at every step: We accept pre-submission inquiries Our selector tool helps you to find the most relevant journal We provide round the clock customer support Convenient online submission Thorough peer review Inclusion in PubMed and all major indexing services Maximum visibility for your research Submit your manuscript at www.biomedcentral.com/submit