Right Choice for Right Angles

Similar documents
The evolution. AORFIX AAA Stent Graft now with the new AORFLEX Delivery System

Access More Patients. Customize Each Seal.

Robert F. Cuff, MD FACS SHMG Vascular Surgery

Talent Abdominal Stent Graft

Optimizing Accuracy of Aortic Stent Grafts in Short Necks

LOWERING THE PROFILE RAISING THE BAR

Zenith Renu AAA Converter Graft. Device Description Planning and Sizing Deployment Sequence Patient Follow-Up

Durability of The Endurant Stent-Graft through 5 Years

Challenging anatomies demand versatility.

Endovascular treatment of morphologically challenging abdominal aortic aneurysms using flexible endograft

FROM THE EVERYDAY TO THE EXTRAORDINARY

Durable outcomes. Proven performance.

Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully

Young-Guk Ko, M.D. Severance Cardiovascular Hospital, Yonsei University Health System,

History of the Powerlink System Design and Clinical Results. Edward B. Diethrich Arizona Heart Hospital Phoenix, AZ

A New EVAR Device for Infrarenal AAAs

My personal experience with INCRAFT in standard and challenging cases

ENCORE, a Study to Investigate the Durability of Polymer EVAR with Ovation A Contemporary Review of 1296 Patients

Aorfix Pythagoras US Clinical Trial:

Increased Flexibility of AneuRx Stent-Graft Reduces Need for Secondary Intervention Following Endovascular Aneurysm Repair

Considerations for a Durable Repair

Overcoming Challenging Aortic Anatomy: from Hostile Necks to Tortuous Iliac arteries

TriVascular Ovation Prime Abdominal Stent Graft System

From 1996 to 1999, a total of 1,193 patients with

Ovation. Sean Lyden, MD Department Chair, Vascular Surgery Cleveland Clinic

Ancillary Components with Z-Trak Introduction System

Aortic stents, types, selection, tricks in deployment.

INCRAFT system: Update from the Pivotal INSPIRATION Study

Anatomical challenges in EVAR

Endovascular Repair o Abdominal. Aortic Aneurysms. Cesar E. Mendoza, M.D. Jackson Memorial Hospital Miami, Florida

THE ENDURANT STENT GRAFT IN HOSTILE ANEURYSM NECK ANATOMY

14F OD Ovation Abdominal Stent Graft System

Hostile Proximal Neck: A New Conformable EVAR Device

Zenith Alpha T HORACIC ENDOVASCULAR GRAFT

Current Status of Abdominal Aortic Stent Grafts. John R. Laird Professor of Medicine Director of the Vascular Center UC Davis Medical Center

Feasibility of aortic neck anatomy for endovascular aneurysm repair in Korean patients with abdominal aortic aneurysm

The clinical update for the Zenith AAA Endovascular Graft has included results from the Zenith AAA Endovascular Graft multi-center clinical study,

Anatomy-Driven Endograft Selection for Abdominal Aortic Aneurysm Repair S. Jay Mathews, MD, MS, FACC

When to use standard EVAR with EndoAnchors or CHEVAR in short-neck AAAs LINC ASIA 18

Treatment options of late failures of EVAS. Michel Reijnen Rijnstate Arnhem The Netherlands

Cook Medical. Zenith Flex AAA Endovascular Graft with Z-Trak Introduction System Physician Training

Dr Peter Bungay Derbyshire Vascular Services Royal Derby Hospital Derby UK

How to select FEVAR versus EVAR + endoanchors in short-necked AAAs

The Ventana Off-the-Shelf Graft for Pararenal AAA. Andrew Holden Associate Professor of Radiology Auckland Hospital

THE THE MORE MORE NATURAL APPROACH TO OPTIMAL FIT

No Neck Is Needed! Treat the Aneurysm Instead! Andrew Holden, MD Associate Professor of Radiology Auckland City Hospital

EVAS using Nellix in my practice Where are we today?

Degeneration of the Neck Post Implementation - a New Era of AAA Stent

Challenges with Complex Anatomies Advancing Care in Endovascular Aortic Treatment

Abdominal Aortic Aneurysm (AAA)

Fenestrated Implantation: How I do it. Tara M Mastracci, FRCSC, FACS, FRCS, MSc Royal Free London

GORE EXCLUDER AAA Endoprosthesis demonstrates long-term durability. Michel Reijnen Rijnstate Hospital Arnhem, The Netherlands

Challenges in the treatment of infrarenal aneurysm & considerations for a durable repair

Current Status of EVAR for Infrarenal AAA. 31 st Annual Florida Vascular Society. PENN Surgery

MODERN METHODS FOR TREATING ABDOMINAL ANEURYSMS AND THORACIC AORTIC DISEASE

Quick Reference Guide

Lessons learned from Ch-EVAR for the treatment of. Miltos Matsagkas MD, PhD, FEBVS Professor of Vascular Surgery University of Thessaly

GORE EXCLUDER AAA Endoprosthesis ANNUAL CLINICAL UPDATE OCTOBER Section I Clinical experience. Section II Worldwide commercial experience

ABDOMINAL XT ABDOMINAL STENT GRAFT SYSTEM

EndoVascular Aneurysm Sealing (EVAS) with Nellix

Influence of patient selection and IFU compliance on outcomes following EVAS

All-In-One. Iliac Branch System. PER F ORM ANC E b y d e s i g n ILIAC BRANCH ENDOPROSTHESIS

2015 Clinical Update Endovascular Systems for AAA Repair

Citation for published version (APA): Tielliu, I. F. J. (2010). Endovascular repair of peripheral artery aneurysms Groningen: s.n.

Conflicts of Interest. When and Why Complex EVAR in Tx of juxta/suprarenal AAA? Summary. Infrarenal EVAR for short necks 2y postop

What's on the Horizon for AAA: Unilateral & Percutaneous, "UP-EVAR" System Zoran Rancic M.D., Ph.D.

Percutaneous Approaches to Aortic Disease in 2018

The Auckland Experience with the Nellix EVAS System. Andrew Holden, MBChB, FRANZCR

Important Update to Field Safety Notice Nellix EndoVascular Aneurysm Sealing System Updated Instructions for Use (IFU)

Abdominal Aortic Aneurysm 가천대길병원 이상준

Vascular V12. Covered Stent. The New Standard of Care

EVAR replaced standard repair in most cases. Why?

EVAS Sealing Technology: The new paradigm in AAA therapy

Challenges. 1. Sizing. 2. Proximal landing zone 3. Distal landing zone 4. Access vessels 5. Spinal cord ischemia 6. Endoleak

How to Categorize the Infrarenal Neck Properly? I Van Herzeele Dept. Thoracic and Vascular Surgery, Ghent University, Belgium

Abdominal Aortic Aneurysms. A Surgeons Perspective Dr. Derek D. Muehrcke

FEVAR FIFTEEN YEARS OF EFFICIENCY E.DUCASSE MD PHD FEBVS CHU DE BORDEAUX

Early Clinical Results with the Valiant Mona LSA Branch Stent-Graft

Chungbuk Regional Cardiovascular Center, Division of Cardiology, Departments of Internal Medicine, Chungbuk National University Hospital Sangmin Kim

DIFFICULT ACCESS REMAINS A CONTRAINDICATION FOR EVAR APOSTOLOS K. TASSIOPOULOS, MD, FACS PROFESSOR AND CHIEF DIVISION OF VASCULAR SURGERY

Mid-term results from ANCHOR: How does this data influence the treatment algorithm for hostile EVAR anatomies

NASDAQ: ELGX December Innovation that Empowers

Disclosures. EVAR follow-up: actual recommendation. EVAR follow-up: critical issues

Arch Repair with the Bolton Medical RelayBranch Thoracic Stent-graft system: Multicenter experience

Analysis of Type IIIb Endoleaks Encountered with Endologix Endografts

Case Report Early and Late Endograft Limb Proximal Migration with Resulting Type 1b Endoleak following an EVAR for Ruptured AAA

Technology. The introduction of endovascular aortic repair. cover story

Treatment of complex thoracic cases Focus on the new Gore Active Control TAG device

Standardization of the CHEVAR procedure: How a standard approach has improved outcomes. Prof Peter Holt St George s, London

How to plan a Zenith AAA stent-graft from a CTA: Basic measurements and concepts explained

Chimney endovascular aneurysm sealing (ch-evas) for ruptured abdominal aortic aneurysms (AAA) due to type Ia endoleak following failed EVAS

EVAS is Associated with Lower All-Cause Mortality

ChEVAR Vs. fevar for juxtarenal Aneurysm. E.Ducasse MD PhD FEVBS Unit of vascular surgery CHU bordeaux

Treating very short necks ( 4mm <10mm) using the Endurant stent graft + EndoAnchors: 1-year results and current insights

Periprosthetic leak and rupture after endovascular repair of abdominal aortic aneurysm: The significance of device design for long-term results

SANWICH TECHNIQUE TO REDUCE COMPLICATIONS WHEN TREATING BILATERAL INTERNAL ILIAC ARTERY

FLEXIBLE, BALOON EXPANDABLE

Endoanchor-assisted TEVAR

Endovascular options of treating iliac aneurysms

BC Vascular Day. Contents. November 3, Abdominal Aortic Aneurysm 2 3. Peripheral Arterial Disease 4 6. Deep Venous Thrombosis 7 8

Transcription:

Right Choice for Right Angles

The Anatomy of Technology Aorfix gives you technology that conforms to patient anatomy, optimising both procedure and post-operative performance. Fishmouth for optimum neck positioning. Excellent seal from 4 closely aligned nitinol wires maximising radial force. Electropolished nitinol rings adapt to highly angulated necks. 8 hooks provide secure fixation. Radiopaque markers to assist positioning. Radiopaque markers Nitinol helical constructed legs conform to complex iliac anatomy.

Durable, Flexible and Adaptable Aorfix gives you the opportunity for single-intervention success by adapting to anatomy during and after the implantation. Electro-polished nitinol wire construction gives excellent durability while following the body s movements. Fabric quality gives improved contouring to landing zones. Flexible construction maintains patency and resists migration as the aneurysm volume reduces. The device s flexible design allows safe and accurate aneurysm sac exclusion in patients with highly challenging anatomy. Balasubramaniam, K., Hardman, J., Horrocks, M., Bulbulia, R. 2009. The advantages of Aorfix for endovascular repair of abdominal aortic aneurysm. Journal of Cardiovascular Surgery, 50, 2, 139-143. High-Angled Neck Source: Mr A. D. McLain, Consultant Vascular Surgery, Royal Gwent Hospital, UK. Tortuous Iliacs Source: Mr D. Morrow, Consultant Vascular Surgery, Norfolk & Norwich Hospital, UK. Aorfix is likely to increase the number of patients considered suitable for EVAR who were previously excluded from this type of treatment and also reduce the risk of endoleaks. Horrocks, M. Retrospective Aorfix DatA Retrieval Registry (RADAR) Presentation. Charing Cross Symposium 2009

Precise Positioning Aorfix enhances the clinician s skills, ensuring it can be positioned optimally for long-term effectiveness. Radiopaque markers Radiopaque markers on the graft body and legs allow precise positioning. The ultra flexible delivery system with its flexible tip allows controlled step-by-step graft deployment in angles up to 90. Effective Sealing Effective sealing as neck angulation increases compared to Z-stent graft design. Endoleak flow rate (ml/sec) 600 400 200 0 0 10 20 30 40 45 50 55 60 65 70 Neck Angulation (deg) Median endoleak flow rate at the corresponding angulation for each manufactured stent graft. Aorfix Competitor 1 Competitor 2 Competitor 3 Competitor 4 Competitor 5 Competitor 6 Competitor 7 Copyright permission provided from BC Decker Inc.; Vascular, Vol. 13, No. 6, pp.321-326, 2005. The Aorfix stent graft has the potential to decrease the incidence of proximal Type I endoleak in patients with a severely angulated aortic neck. Albertini, J. N., DeMasi, M. A., Macierewicz, J., El Idrissi, R., Hopkinson, B. R., Clément, C., Branchereau, A. 2005. Aorfix stent graft for abdominal aortic aneurysms reduces the risk of proximal Type I endoleak in angulated necks: bench-test study. Vascular, 13, 6, 321-326.

Aorfix stays where you place it 8 coplanar hooks are designed to maximise fixation security and resist graft migration. Interlocking helical design Analysis of Stent Graft Failure Pull Out Forces Box plot comparing maximum (median, interquartile range) pull out forces of stent grafts. 40 Pull Out Force (N) 30 20 10 23.7N Aorfix GEN I Interlocking helical design gives secure iliac limb engagement, as the device changes with anatomy over time resisting dislocation risk for Type III endoleak. 0 Competitor 1 Competitor 2 Competitor 3 Aorfix Copyright permission provided from ISES Inc.; J Endovasc Ther, 2006, 13:77-84. Hinchliffe, R. J., Natarajan, S., Hopkinson, B. R. 2006. In vitro analysis of modular aortic stent graft failure. Journal of Endovascular Therapy, 13, 77-84.

Aorfix Sizing Guide Use the following steps to assess the most appropriate size of Aorfix device for a given CT scan: 1 2 3 4 5 6 7 8 9 10 11 12 Access Vessel Size and Quality: assess the diameter and quality of the access vessels in relation to the Aorfix delivery system sizes: 22Fr outer diameter for the main body. 20Fr outer diameter for the contralateral leg and distal extensions. Ipsilateral Side: determine which side of the patient will be used as the ipsilateral side. Consider factors such as the direction and degree of proximal neck angulation, iliac vessel tortuosity and access vessel dimensions. Proximal Neck Length: measure the length from the inferior margin of the distal renal artery to immediately superior to the start of aneurysmal dilation to determine the length of proximal neck. Proximal Diameter (D1): measure the aortic diameter at several levels in the proximal neck. Measure diameters from internal wall to internal wall. Determine the largest diameter in the proximal neck. Oversize this diameter to determine the D1 graft diameter. Refer to the IFU for recommended oversizing parameters. SMA to Distal Renal Distance: measure the length between the inferior margin of the SMA and the inferior margin of the distal renal artery. Graft Main Body Length (L1): measure the length from inferior margin of the distal renal artery to the aortic bifurcation. The distal opening of the cannulation socket will usually lie between 10 and 30 mm above the aortic bifurcation. Choose an appropriate L1 from the lengths available. Diameter at the Cannulation Socket: measure the diameter at the level of the cannulation socket. Aortic Bifurcation Diameter: measure the diameter at the level of the aortic bifurcation. Ipsilateral Leg Length (L2): measure the length from the level of the cannulation socket to the ipsilateral common iliac artery bifurcation. Choose an appropriate L2 length. The graft limb length should normally result in the distal fishmouth lying proximal to the internal iliac artery origin. Ipsilateral leg distal diameter (D2): measure the diameter of the selected landing zone at several levels. Oversize appropriately to determine the graft diameter D2. Contralateral leg length (L3): measure the distance from the level of the cannulation socket to the level of the contralateral common iliac artery bifurcation. Choose an appropriate L3 Length. Contralateral leg distal diameter (D3): measure the diameter of the common iliac artery at several levels in the region of the projected landing zone. Oversize appropriately to determine the graft diameter D3.

Aorfix Sizing D1 Measure a range of diameters in the neck. Oversize largest diameter by 10%. SMA to distal origin of renal artery with 10% oversizing fishmouth is 7-12 mm deep. Take care if SMA is 10 mm from inf. renal artery. L1 Graft length from decided proximal landing zone to aortic bifurcation minus approx. 10-30 mm. Position cannulation socket 10-30 mm above level of aortic bifurcation. L2 Cannulation socket to distal landing zone position (see note on step-by-step guide). D2 Diameter at distal landing zone. Oversize by 10%. D3 Diameter at distal landing zone. Oversize by 10%. Diameter at cannulation socket and aortic bifurcation should be 24 x 12 mm. L3 Cannulation socket to distal landing zone position (see note on step-by-step guide). DISCLAIMER It is the responsibility of the clinician to assess the suitability of Aorfix for their patient by referring to the Instructions for Use (IFU). The information included in this brochure should not be used as an EVAR training tool and does not replace clinical expertise. Clinicians should understand the principles related to endovascular stent grafts and be trained in EVAR techniques prior to commencing any EVAR procedure.

Aorfix Clinical Results European Multi-Centre Arbiter II study results All AAAs had high-angled infra-renal necks (range 70 90 ) and placement was well tolerated. Low occurrence of device deployment events. Incidence of endoleaks at 30 days was superior to that of the comparator historical data set. 30-day and 6-month follow ups show no reports of device rupture, migration, stent fracture, loss of patency, vessel perforation, significant obstruction or conversion to open repair. All patients at six months follow up had stable or shrinking aneurysm sacs. RADAR Registry Results The Retrospective Aorfix Data Retrieval ( RADAR ) voluntary international registry includes data from 1236 cases with a follow up range up to 8 yrs (as of March 2011). A wide spectrum of patients have been successfully treated including significant numbers having AAAs with severely angled necks and/or tortuous iliacs. Feature Neck angle < 60 Neck angle 60 Eligible cases for 1 year follow up 294 215 Endoleaks Type 1 0.0% 4.3% Stent migration (> 30 days up to 12 months) 0.0% 1.9% Wire fracture (> 30 days up to 12 months) 0.0% 0.0% Customer Value Added Support International training workshops. Case planning: 3D TeraRecon imaging software technology for learning curve case sizing reports. Field sizing support via specialists and sizing guide. Clinical and technical proctors case attendance. Pick from stock wide range of graft sizes. Special (SP) non-stock graft sizes built by request. Lombard Medical Limited, Lombard Medical House 4 Trident Park, Didcot, Oxon, OX11 7HJ, UK Tel: +44 (0)1235 750800 Fax: +44 (0)1235 750879 www.lombardmedical.com Registered in England and Wales Reg No. 2998639 2011 by Lombard Medical Limited. All rights reserved. Aorfix is a trademark of Lombard Medical Limited. Not for Distribution in the USA. *CE Marked, please refer to current Aorfix IFU. Data on file Lombard Medical Limited, April 2009. ART-MS-019-v7/04/2011