A DEVICE FOR THE INDIRECT RECORDING OF BLOOD PRESSURE

Similar documents
Assessment of techniques for measurement of blood pressure in infants and children

Characterization of the Oscillometric Method for Measuring Indirect Blood Pressure

Taking and recording blood pressure and pulse. City Gate Training Centre all rights reserved

Physiology of the Circulatory System modified from

Lab #10 Physiology of the Circulatory System

A GUIDE TO OUR NIBP TECHNOLOGY

Managing Blood Pressure: It Takes a Team

AFRL-RH-WP-TR

LAB 9: Metabolic Rates

AP Biology Lab 10 PHYSIOLOGY OF THE CIRCULATORY SYSTEM

AFFORDABLE TECHNOLOGY

SARASOTA MEMORIAL HOSPITAL NURSING PROCEDURE. MEASURING BLOOD PRESSURE - MANUAL (equ04)

Biomedical Instrumentation E. Blood Pressure

INDIRECT ANKLE, BRACHIAL AND DIRECT INTRA -ARTERIAL BLOOD PRESSURE MEASUREMENTS

Protocol 4: Measuring Blood Pressure

External Oscillatory Blood Pressure - EOBPTM

Dual-Cuff Method Improves Accuracy of Blood Pressure and Hemodynamics Determination

Section 03: Pre Exercise Evaluations and Risk Factor Assessment

How To Measure Vital Signs

1 Non-invasive measurement of arterial pressure

PART I: HEART ANATOMY

Chapter 12 - Vital_Signs_and_Monitoring_Devices

2. Measure a subject's blood pressure and heart rate both at rest and during exercise.

Heart Rate and Blood Pressure as Vital Signs

Blood Pressure Laboratory

The measurement of blood pressure and hypertension. Handout Fenyvesi Tamás III.Department of Medicine

An Automated System for Blood Pressure Determination During Exercise

STUDIES INVOLVING THE NON-INVASIVE MEASUREMENT OF BLOOD PRESSURE IN THE ARM

CAMOSUN COLLEGE BIOLOGY 144 (2010) LABS

#6 - Cardiovascular III Heart Sounds, Pulse Rate, Hemoglobin Saturation, and Blood Pressure

Chapter-III METHODOLOGY. In this chapter, the procedure adopted for the selection of the

5.2. MEASUREMENT OF BLOOD PRESSURE

CHAPTER 4 ESTIMATION OF BLOOD PRESSURE USING PULSE TRANSIT TIME

Blood Pressure and Exercise Lab

Ambulatory Services Orientation & Skill Review Skill Performance Checklist: Vital Signs. Name: Date:

UNCLASSIFIED AD DEFENSE DOCUMENTATION CENTER FOR SCIENTIFIC AND TECHNICAL INFORMATION. CAMERON STATION. AtEXANDRIA. VIRGINIA UNCLASSIFIED

PHONOCARDIOGRAPHY (PCG)

Validity study of oscillometric blood pressure measurement devices using an oscillometric waveform simulator

IB TOPIC 6.2 THE BLOOD SYSTEM

WHILE it is generally agreed that elevation

IB TOPIC 6.2 THE BLOOD SYSTEM

CARDIOVASCULAR MONITORING. Prof. Yasser Mostafa Kadah

BP-600 Noninvasive Blood Pressure Sensor

AMERICAN ASSOCIATION OF SLEEP TECHNOLOGISTS TECHNICAL GUIDELINE FOR PATIENT ASSESSMENT AND VITAL SIGNS MEASUREMENT AND DOCUMENTATION

Arteriosonde, and mercury sphygmomanometer in

Physiology lecture 15 Hemodynamic

PLANK 1 Direct Care Staff Trained in Accurate BP Measurement

The Significance of the Intermediate Korotkoff Sounds

PROBLEM SET 2. Assigned: February 10, 2004 Due: February 19, 2004

Heart Rate, Blood Pressure, and Exercise. Evaluation copy

Data Collection Worksheet

ECG, Blood Pressure, and Exercise Lab

MEASUREMENT OF BLOOD PRESSURE. Department of Clinical Physiology, The Hospital for Sick Children, Great Ormond Street, London, W.C.

HUMAN ANATOMY AND PHYSIOLOGY

Identify and describe the circulation system that is missing from the organizer above.

Received 10 April 2008 Revised 23 June 2008 Accepted 24 June 2008

Smith, Miller and Grab er(4) state that the maintenance of an efficient

I.NCLASSIFIED. Reproduced by DOCUMENT SERVICE CENTER KNOTT BUILDING, DAYTON, 2, OHIO

Lab #3: Electrocardiogram (ECG / EKG)

Importance Of Taking Manual Blood Pressure In Both Arms

and bias, which are known to be present in self-home and in professional office BP measurements taken using the auscultatory technique [7].

LAB: Blood Pressure Measurable Indicator of the Health of the Circulatory System!

Determination of Stroke Volume from Left Ventricular Isovolumetric Contraction and Ejection Times

to use the proper technique often lead to the wrong diagnosis, which may indirect measurement ofblood pressure. 240k

GETTING THE NUMBERS RIGHT: ACCURATE MEASUREMENT OF BLOOD PRESSURE

JAMES R. KNIGHT

AFRL-RH-WP-TR

Vital Signs. Vital Signs. Pulse. Temperature. Respiration. Blood Pressure

Lesson 16 BLOOD PRESSURE

Non-Invasive Method of Blood Pressure Measurement Validated in a Mathematical Model

UNCLASSIFIED. o ADm/e ARMED SERVICES TECHNICAL INFORMATION AGENCY ARLINGTON HALL STATION ARLINGTON 12, VIRGINIA UNCLASSIFIED

AN INTRODUCTION TO DOPPLER. Sarah Gardner, Clinical lead, Tissue viability service. Oxford Health NHS Foundation Trust.

Medical Electronics Dr. Neil Townsend Michaelmas Term 2001 ( The story so far.

mainly due to variability of the end-inspiratory point, although subjectively

Cardiovascular Physiology

Blood Pressure Competency Training

Teclin ical information Agency

Clinical Evaluation of an Oscillometric NIBP Technology During Hemodialysis According to the British Hypertension Society Protocol

12.2 Monitoring the Human Circulatory System

Lectures on Medical Biophysics Department of Biophysics, Medical Faculty, Masaryk University in Brno. Biophysics of cardiovascular system

Blood Pressure Measurement During Pregnancy: Auscultatory Versus Oscillatory Methods

BLOOD PRESSURE ASSESSMENT

Clinical Research Coordinator Skills Program

Welcome to the S410. Blood Pressure System. Instruction Manual

Human Cardiovascular Physiology: Blood Pressure and Pulse Determinations

The Circulatory System. Lesson Overview. Lesson Overview The Circulatory System

Evaluation of the Accutracker I1 noninvasive ambulatory blood pressure recorder according to the AAMI Standard

Chapter 7. Blood Pressure and Sound

Blood Pressure Estimation Using Photoplethysmography (PPG)

Comparison of Exercise Blood Pressure Measured by Technician and an Automated System

by Starling [1914] and Daly [1925].

Blood Pressure Measurement by Pulse Oxymetric Method and Comparison with Conventional Technique

(Received 25 July 1938)

Baseline Vital Signs and SAMPLE History. Chapter 5

Collage of medicine Cardiovascular Physiology 3- Arterial and venous blood Pressure.

ADVANCED PATIENT MONITORING DURING ANAESTHESIA: PART ONE

Declaration of Equivalence Form

The Cardiac Cycle Clive M. Baumgarten, Ph.D.

Chapter 15: Measuring Height, Weight, and Vital Signs. Copyright 2012 Wolters Kluwer Health Lippincott Williams & Wilkins

Transcription:

WADC TECHNICAL NOTE 55-427 T A DEVICE FOR THE INDIRECT RECORDING OF BLOOD PRESSURE GEORGE D. ZUIDEMA ROBERT EDELBERG EDWIN W. SALZMAN AERO MEDICAL LABORATORY SEPTEMBER 1955 WRIGHT AIR DEVELOPMENT CENTER

NOTICES When Government drawings, specifications, or other data. are used for any purpose other than in connection with a definitely related Government procurement operation, the United States Government thereby incurs no responsibility nor any obligation whatsoever; and the fact that the Government may have formulated, furnished, or in any way supplied the said drawings, specifications, or other data, is not to be regarded by implication or otherwise as in any manner licensing the holder or any other person or corporation, or conveying any rights or permission to manufacture, use, or sell any patented invention that may in any way be related thereto. Qualified requesters may obtain copies of this report from the ASTIA Document Service Center, Knott Building, Dayton 2, Ohio. Copies of WADC Technical Reports and Technical Notes should not be returned to the Wright Air Development Center unless return is required by security considerations, contractual obligations, or notice on a specific document.

WADC TECHNICAL NOTE 55-427 A DEVICE FOR THE INDIRECT RECORDING OF BLOOD PRESSURE GEORGE D. ZUIDEMA ROBERT EDELBERG EDWIN W. SALZMAN AERO MEDICAL LABORATORY SEPTEMBER 1955 PROJECT No. 7216 TASK No. 71712 WRIGHT AIR DEVELOPMENT CENTER AIR RESEARCH AND DEVELOPMENT COMMAND UNITED STATES AIR FORCE WRIGHT-PATTERSON AIR FORCE BASE, OHIO Carpenter Litho & Prtg. Co., Springfield, 0. 200 - May 1956

FOREWORD This report was prepared in the Acceleration Section, Biophysics Branch, Aero Medical Laboratory, under the authority of Project No. 7216 'Physiology of Acceleration'* Lt. G. Do Zuidema, USAF(M4), Dr. Robert Edelberg and Lt. Edwin W. Salzman, USAF (MC) served as the principal investigators. The authors wish to acknowledge the help of Mr. W. 3. White and Mr. lames E. Smithson, Psychology Branch, for their statistical treatment of the raw data. WADC TR 55-427

ABSTRACT A device for the repeated recording of blood pressure without arterial puncture has been developed for use in the experimental work on the heart and circulation. Pulse waves from the brachial artery are picked up by a plastic balloon underlying the conventional blood pressure cuff and recorded by means of a Statham pressure transducer and an oscillograph. The cuff is automatically inflated every 30 seconds and a tracing of the pressure fall recorded on the Same paper. Since the systolic and diastolic pulse waves are easily recognized, their respective pressures are found by reference to the record of the pressure fall recorded simultaneously. This method, successfully employed in 90 determinations on 10 subjects, gave good results; the values agreeing accurately and consistently with those obtained by conventional means. Such a system should prove useful in wide areas of experimental work, including studies of the response of the body to stress. Its use in the high altitude low pressure chambers is described. PUBLICATION REVIEW This report has been reviewed and is approved. FOR THE CODMMflDER: SACK BOLLERUD Colonel, USAF(MN) Chief, Aero Medical Laboratory Directorate of Research WADC TN 55-427 iii

TABLE OF CONTENTS SECTION Page I Introduction 1 II Review of Literature 1 III Equipment and Procedure 2 IV Results and Discussion 3 V Statistical Analysis 5 VI Summary 6 Bibliography 7 WADC TN 55-h27 iv

SECTION I INTRODUCT ION In many fields of investigation it is important to follow the cardiovascular status of the subject by means of his blood pressure and pulse changes. This is especially true in the study of acceleration and high altitude flight where cardiovascular responses become all-important. It is also convenient to have a graphic record of these parameters for purposes of study and illustration. A device for the automatic recording of the blood pressure and pulse is desirable because it performs these function and has the additional value of freeing one member of tne research team from the task of recording pulse rate and blood pressure at frequent intervals throughout the experiment. The direct method for recording blood pregsure is by means of an intraarterial needle connected to a manometer and recording system. A technique requiring arterial puncture is, for obvious reasons, less acceptable to the subject than an indirect bloodless method. SECTON II REVIEW OF THE LITERATURE A number of investigators have been interested in the development of a device for the automatic recording of blood pressure. In 1901, Von Recklinghause (1) employed an arm and a manual pump. The cuff was inflated to a pressure sufficient to occlude the brachial artery and allowed to deflate slowly. Systolic pressure was considered that point at which the systemic arterial pressure was just sufficient to overcome the pressure within the cuff. The pulse waves, as transmitted to the cuff, were recorded on a smoked drum. Under this system, the first abrupt increase in amplitude of the pulse waves was considered systolic pressure; diastolic pressure was recognized by a decrease in the amplitude. In 1908, Erlanger (2) developed an instrument based on this same principle and also noted that not only did the amplitude increase as systolic pressure was reached, but that the pulse wave was changed in form at this point, manifested by a wider separation of the ascending and descending strokes. Von Recklinghause (1), Erlanger (2) (3), MacWilliams and Melvin (4) carried out extensive studies n the distensibility of arteries and the configuration of the pulse wave. Von Bonsdorff (5) utilized a Broemser glass plate optical manometer to take and record blood pressure while Gilson (6) and Weiss (7) employed a type of microphone overlying the brachial artery to record the sounds as they appeared and disappeared with pressure alterations within the cuff. WADC TN 55-427

SECTION III EQUIPMENT AND PROCEDURE RECORDING SPHYGMOMANOMETER,,.::i~iiibii Hg MANOMETER PU M P BLOOD 0-250 mm PRESSURE PRESSURE TRANSDUCER (b) S "":.WAT f ER FILLED 1 PLASTIC BLADDE 0-250 mm 70-2r39 PRESSURE TRANSDUCER CONDENSER CONSOLIDATED (a) RECORDING OSCILLOGRAPH Figure 1. Diagramatic presentation of the components of the recording sphygmomanometer. Two of the basic components of the present system (Figure 1) are similar to those employed in previous devices for the automatic recording of blood pressure. These consist of a conventional blood pressure arm cuff and an electric pump which is used to inflate the cuff. This pump has been modified so as to automatically perform the inflation in one or two seconds and then shut off upon reaching the desired pressure of 240 mm Hg. The pressure is then allcwed to subside to ambient over the next 22 to 24 seconds. The entire cycle, approximately 25 seconds long, is then repeated continuously until terminated by the operator. A mercury manometer in the circuit allows reading of the pressure in the cuff at any given time, and is also used for calibrating the system. The pressure fall within the cuff is followed by means of a Statham pressure transducer (b) recording on a Consolidated oscillograph with a 7-215 galvanometer with a sensitivity of 13 micro amps. per inch. The pulse waves are picked up by a fluid-filled plastic balloon which fits beneath the cuff and overlies the brachial artery (Figure 1). The waves are transmitted through a fluid filled polyethylene catheter to a Statham transducer (a) for recording on the oscillograph with a 7-239 galvanometer with a sensitivity of 4 micro amps. per inch. A conventional type of blood pressure cuff has been modified to include such a plastic balloon and its associated transducer (a) as a single unit, thus greatly simplifying the attachment of the components to the individual subjects. The recording of the transducer (b) showing the fall of pressure within the cuff appears simultaneuosly with the recording of the individual pulse WADC TN 5_.-427 2

waves from the balloon. The use of a 200 to 1000 mtd condenser in series with the output of the transducer (a) serves to flatten out the baseline by eliminating the large, slow drop in pressure within the cuff, while preserving the smaller pulse waves from within the balloon (Figure 2). Figure 2. Ostillograph record showing pulse (upper, horizontal line) and record of pressure within the cuff(falling line). Since the systolic and (1) diastolic (2) (4) (Figure configurations 3). their are respective easily recognized ence to the point on pressures the calibrated are determined pressure by curve refer- at which they With appear. modifications, altitude this chambers system was in used within the low pressure excess of 60,000 feet. pressure-high transducers were Under these circumstances, in the placed balloon-transducer within the chamber. both Boiled air-containing system to avoid water bubble was formation Used cuff-transducer at during system was altitude. ascent opened to The to assure the chamber ducer a constant pressure atmosphere membrane. The blood differential across ing pressure cuff was the the inflated trans- system to outside atmospheric at altitude pressure, by open- and was deflated by bleeding it into the chamber. SECTION IV RESULTS AND DISCUSSIONS Ninety determination blood pressure were carried as taken out on 10 subjects to by by the automatic recording compare auscultation. the The method physicians, readings were performed with that in taken each of whom a random order diastolic kept his results independently. by three pressure was In every upon noted both when muffling case, their of the disappearance, At the the sounds conclusion occurred of the and experiment the results WAUC TN 55-427 3

AI 140 I 12o- 800 so- 60-40- Figure 3. Oscillograph record with the systolic and diastolic pressures marked (arrows), and calibration of cuff pressure added at the left. Dottea lines show how systolic and diastolic pressures are determined by referencing the cuff pressure. of the recorded and auscultatory blood pressures, which had been taken simultaneously, were paired for purposes of comparison and statistical treatment. Statistical analysis revealed a correlation coefficient of 0.97 be& tween the auscultatory and automatic recording methoda. The automatic measurements also demonstrated a greater degree of constancy from one determination to the next than was seen in those determined by auscultation. From this analysis we may conclude that the automatic method agrees well in accuracy with auscultatory methods in the hands of a physician. The recorder is also subject to the same limitations as auscultation. That is, both are indirect measures and depend upon the use of an occlusive cuff. The accurate use of either method demands at least 20 seconds to allow for enough pulse beats to come through for clear detection of systolic and diastolic pressures. This precludes the use of the automatic method for determination of pulse pressure at a given instant in time. However, few situations demand such speed, and therefore the recorder fills a wide range of usefulness. An automatic recorder has the additional advantage of removing the possibility of subjective error in the process of listening for beats. It also removes whatever psychological effect there might be related to the presence of a physician. WADC TN 55-427 4

A number of authors have studied the relationship of various indirect methods for the measurement of blood pressure with actual intra-arterial determinations. Hamilton, et al (8) found that in a series of 30 comparisons, the indirect cuff method gave readings averaging three to four millimeters of mercury lower for systolic and nine millimeters of mercury higher for diastolic than the direct reading. Steele (9) also compared auscultatory with intra-arterial determinations. He showed that systolic pressure was underestimated in auscultation by about 10 mm Hg, and felt, as did Bordley, et al (10),that disappearance of the sounds was a more accurate measure of diastolic pressure than muffling, or the 4th phase of Korotkow. On the other hand, Roberts, et al (11) felt that muffling was more reliable in denoting diastolic pressure. It was our experience that diastolic pressure, as determined by the disappearance of sounds, agreed more closely with diastolic pressure measured automatically. Van Bergen, et al (12) compared three indirect methods with direct determinations. In their study, oscillometric recording, auscultatory and palpatory methods were found to agree in that order of descending accuracy. Their most accurate method, i.e., oscillometric, described systolic pressure as the point at which the meniscus of the pulsating mercury column of the manometer became convex. Diastolic pressure by this method wculd be of questionable accuracy. In their case, all indirect readings fell slightly below direct measurements and, as pressure rose, the indirect readings fell farther below direct. SECTION V STATISTICAL ANALYSIS The mean difference in systolic pressures, as measured by auscultation and recorder, was 1.lmm Hg, with a standard deviation of 5.05 mm 11g. The mean difference does not appear to be significantly different from a postulated zero difference, when compared by a t-test. It seems safe to conclude that over the combination of physicians, times and subjects employed in the experiment, no difference is expected to occur between the measurements taken by the two methods. However, the expected limits -f-chance variation are, in 95 % of the cases, ± 2.59 (5.05) or ± 13.08 w. Hg, and in 90 % of the cases, ± 6.6 mm Hg. The coefficient of correlation of systolic measurements by the two methods is 0.95. The mean difference is diastolic pressures was 2.38 mm Hg, with a standard deviation of 5.48 mm Hg. This mean difference is significantly different from a postulated zero difference by t-test. Thus, auscultatory measurements by disappearance of the sound are, under these conditions, slightly higher than recorder measurements, on the average. This difference is subject to chance variations of about the same magnitude as those obtained in systolic measurements. The coefficient of correlation of diastolic measurements was 0.95. WADC TN 55-427 5

Auscultatory measurements by three physicians were treated by analysis of variance. In the course of 30 determinations by each physician, systolic pressures were found to vary on an average of 3.0 nim Hg. From this it can be seen that the mean difference between determinations by the automatic method is less in both cases than the expected difference between any two physicians. SECTION VI SU24ARY 1. An indirect method for the repeated recording of blood pressure in man is described. 2. Statistical validation of the method is submitted. 3. Successful use of this system in the high altitude chamber is reported. WADO TN 55-427 6

BIBLIOGRAPHY 1. von Recklinghausen, H.,"Uber Blutseuchmessung beim menschen." Arch. fur Experimental Pathologie, 46:78, 1901. 2. Erlanger, E. "New Criterion for the Determination of the Systolic Blood Pressure with the Sphygmomanometer". Am. 1. Physiol. 21: No. 1, XXIV, 1908. 3. Erlanger, E., and Meek, W. T., "An Adjustable Sphypmoscope for the Recording Sphygmomanometer". I. Lab & Clin. Med. XII, No. 2, 170, 1926. 4. MiacWilliam, 3. A., and Melvin, G. Spencer, "The Estimation of Diastolic Blood Pressure in Man". Heart, V: 153, 1914. 5. von Borndorff, B., "Zur Methodik der Blutdruckmessung". Acts. Ped. Scand. Suppl. LI: 8, 1932. 6. Gilson, W. E., Goldberg, H., and Slocum, H., "An Automatic Device for Periodically Determining and Recording Both Systolic and Diastolic Blood Pressure in Man". Science, 94: 194, 1941. 7. Weiss, H., "An Automatic Blood Pressure Recording Apparatus". ;. Lab. & Clin. Med., 26: 1351, 1941. 8. Hamilton, W. F., Woodbury, R. A., and Harper, H. T., "Physiologic Relationship between Intrathoracic, Intraspinal and Arterial Pressure". T.A.M.A. 107: 853, 1936. 9. Steele, 3. M., "Measurement of Arterial Pressure in Man". T. Mt. Sinai Hospital, 8; 1049, 1941-42. 10. Bordley, Y., Conner, C. A., Hamilton, W. F., Kerr, W. I., and Wiggers, C. 3., "Recommendations of Human Blood Pressure Determinations by Sphygmomanometer". Circulation, 4: 503, 1951. 11. Roberts, L. N., Smiley, 3. R., and Manning, G. W., "A Comparison of Direct and Indirect Blood Pressure Determination". Circulation, 8: 232, 1953. 12. Van Bergen, F. H., Weatherhead, D. S., Treloar, A. E., Dobkin, A. B., and Buckley, 3. 3., "Comparison of Indirect and Direct Methods of Measuring Arterial Blood Pressure". Circulation, 4; 481, 1954. WADC TN 55-427 7