Recent Advances in Pacing and Defibrillation Harish Doppalapudi, MD

Similar documents
Newer pacemakers also can monitor your blood temperature, breathing, and other factors and adjust your heart rate to changes in your activity.

EBR Systems, Inc. 686 W. Maude Ave., Suite 102 Sunnyvale, CA USA

Leadless Pacing. Osama Diab Assistant Prof. of Cardiology Ain Shams University Egypt

King s Research Portal

Essentials of Pacemakers and ICD s. Rajesh Banker, MD, MPH

Different indications for pacemaker implantation are the following:

NEIL CISPER TECHNICAL FIELD ENGINEER ICD/CRTD BASICS

Cardiac implantable electronic devices (CIEDs) in children include pacemakers and implantable cardioverter defibrillators (ICDs).

Supplemental Material

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE

UnitedHealthcare Medicare Advantage Cardiology Prior Authorization Program

The protection you need - without touching your heart

Leadless pacemakers and subcutaneous ICD s: will we use them for most of our patients? K.-H. Kuck Asklepios Klinik St. Georg Hamburg, Germany

INNOVATIONS IN DEVICE THERAPY:

Pediatric pacemakers & ICDs:

NOVEL DEVICE TECHNOLOGIES

Leadless pacemakers a panacea for bradyarrhythmias?

NEED A DEFIBRILLATOR? NOW YOU HAVE OPTIONS.

Cardiac Imaging in abnormal rhythm Role of MDCT

Kadlec Regional Medical Center Cardiac Electrophysiology

OBJECTIVE. 1. Define defibrillation. 2. Describe Need and history of defibrillation. 3. Describe the principle and mechanism of defibrillation.

PACING AT THE BUNDLE OF HIS

Girish M Nair, Seeger Shen, Pablo B Nery, Calum J Redpath, David H Birnie

Cardiac Implanted Electronic Devices Pacemakers, Defibrillators, Cardiac Resynchronization Devices, Loop Recorders, etc.

A Square Peg in a Round Hole: CRT IN PAEDIATRICS AND CONGENITAL HEART DISEASE

Understanding Atrial Fibrillation A guide for patients

Cardiac Resynchronisation Therapy Patient Information

Cardiac Pacing. Learning outcomes. Introduction. The cardiac impulse - its formation and its failure CHAPTER. To understand:

Pacing Without Wires: Leadless Cardiac Pacing

UnitedHealthcare, UnitedHealthcare of the River Valley and Neighborhood Health Partnership Cardiology Notification and Prior Authorization Program:

Sudden death from abnormal heart rhythm: Am I at risk?

DEFIBRILLATORS. Prof. Yasser Mostafa Kadah

Leadless pacing. P.E. Vardas Professor of Cardiology University of Crete, Greece

PACEMAKER INTERPRETATION AND DEVICE MANAGEMENT PART II

Implantation of a Cardiac Resynchronisation Therapy-Defibrillator (CRT-D)

Figure 2. Normal ECG tracing. Table 1.

SUPPLEMENTAL MATERIAL

ICD Implantation Patient Information

About atrial fibrillation (AFib) Atrial Fibrillation (AFib) What is AFib? What s the danger? Who gets AFib?

Leadless pacing: Technical challenges and concerns. Panos Vardas President Elect of the ESC, Prof. of Cardiology, Heraklion University Hospital

UnitedHealthcare, UnitedHealthcare of the River Valley and Neighborhood Health Partnership Cardiology Notification and Prior Authorization Program:

PERMANENT PACEMAKERS AND IMPLANTABLE DEFIBRILLATORS Considerations for intensivists

UNDERSTANDING ELECTROPHYSIOLOGY STUDIES

The heart's "natural" pacemaker is called the sinoatrial (SA) node or sinus node.

Cardiovascular Nursing Practice: A Comprehensive Resource Manual and Study Guide for Clinical Nurses 2 nd Edition

VT Ablation in Structural Heart Disease Patient Information

Atrial Fibrillation. Damage to your heart caused by a heart attack or rheumatic heart disease

ICD: Basics, Programming and Trouble-shooting

REVIEW ARTICLE. Leadless Cardiac Pacemaker Therapy. An Overview for the Hospitalist Richard Weachter 1

2010 Canadian Cardiovascular Society/ Canadian Heart Rhythm Society Training and Maintenance of Competency in Adult Clinical Cardiac

Arrhythmias. Pulmonary Artery

New generations pacemakers and ICDs: an update

ATRIAL FIBRILLATION ANSWERS. A Patient Education Handbook on Electrophysiology

Model 5392 EPG Temporary Pacer

Cardiac Resynchronization Therapy. Michelle Khoo, MD

Puzzling Pacemakers Cheryl Herrmann, APN, CCRN, CCNS-CSC-CMC

Make you feel better Make you live longer

Transvenous Pacemaker Procedures

Non-Invasive Ablation of Ventricular Tachycardia

Specialised Services Policy Position PP151

X-Plain Atrial Fibrillation Reference Summary

Ventricular Tachycardia in Structurally Normal Hearts (Idiopathic VT) Patient Information

PERFORMANCE MEASURE TECHNICAL SPECIFICATIONS. HRS-3: Implantable Cardioverter-Defibrillator (ICD) Complications Rate

When to implant an ICD in systemic right ventricle?

IHCP bulletin INDIANA HEALTH COVERAGE PROGRAMS BT JANUARY 24, 2012

ESC Stockholm Arrhythmias & pacing

Finally, a pacemaker may be either permanent or temporary, which will also factor into your code selections.

Review of Pacemakers and ICD Therapy: Overview and Patient Management

DEFIBRILLATORS ATRIAL AND VENTRICULAR FIBRILLATION

THE HEART THE CIRCULATORY SYSTEM

Cigna - Prior Authorization Procedure List Cardiology

Introduction. Case Report ECG & EP CASES ABSTRACT

PACEMAKER INTERPRETATION AND DEVICE MANAGEMENT PART I

MEDICAL POLICY Cardioverter Defibrillators

Pediatric Pacemaker Implantation Endocardial or Epicardial

Electrocardiography for Healthcare Professionals

Mission Statement for our Arrhythmia Care

Q & A: How to Safely Scan Patients with a SureScan MRI Pacemaker

Introduction to Lesson 2 - Heartbeat

Implantable Cardioverter-Defibril. Defibrillators. Ratko Magjarević

Cardiac Electrophysiology

PATIENT WITH ARRHYTHMIA IN DENTIST S OFFICE. Małgorzata Kurpesa, MD., PhD. Chair&Department of Cardiology

Subcutaneous implantable cardioverter defibrillator insertion for preventing sudden cardiac death

Cardiology. Objectives. Chapter

Temporary pacemaker 삼성서울병원 심장혈관센터심장검사실 박정왜 RN, CCDS

2017 HRS Expert Consensus Statement on Cardiovascular Implantable Electronic Device Lead Management and Extraction

CURRICULUM GOALS AND OBJECTIVES CLINICAL CARDIOVASCULAR ELECTROPHYSIOLOGY TRAINING PROGRAM. University of Florida Gainesville, Florida

INTERNAL CARDIOVERSION. Lancashire & South Cumbria Cardiac Network

NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE

ST. DOMINIC HOSPITAL CARDIOLOGY SERVICE

Cardiac Resynchronization ICD Therapy: What is New?

Patient Resources: Arrhythmias and Congenital Heart Disease

OVERVIEW OF ARRHYTHMIA

CRT Implantation Techniques 부천세종병원순환기내과박상원

University of Wisconsin - Madison Cardiovascular Medicine Fellowship Program UW CICU Rotation Goals and Objectives

NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE

University of Wisconsin - Madison Cardiovascular Medicine Fellowship Program UW CCU Rotation Goals and Objectives Goals

Technical option of surgical approach for trouble-shooting

Unknown ECGs for the Clinician

Understanding Atrial Fibrillation

Transcription:

Recent Advances in Pacing and Defibrillation Harish Doppalapudi, MD Harish Doppalapudi, MD Assistant Professor of Medicine Director, Clinical Cardiac Electrophysiology Training Program University of Alabama at Birmingham FOT 930, 1720 2 nd Avenue South, Birmingham, AL, USA 35294-3409 Tel: 205-934-3614 Fax: 205-934-3950 harish@uab.edu Abstract: Most current pacemaker and ICD systems involve placement of lead(s) transvenously into the heart, connected to a pulse generator. Vascular access may be difficult or limited in some patients, and intravascular leads can be associated with multiple complications such as infection, lead malfunction and vascular occlusion. Recent advances in pacing and ICDs include the development of subcutaneous ICDs and leadless pacing. Subcutaneous ICDs do not require a transvenous access or lead, and have become an important option for patients with indications for ICDs who have limited or difficult vascular access or have a significant risk with this approach. In addition, subcutaneous ICDs can be offered as an alternative to transvenous ICDs in certain patients. Leadless pacing is evolving as a new approach to pacing that can avoid or mitigate the issues associated with intravascular leads. Self-powered leadless cardiac pacemakers have been shown to be a safe and feasible option for patients requiring single chamber pacing. In addition, leadless ultrasound-based pacing has been shown to provide effective left ventricular pacing for cardiac resynchronization therapy in conjunction with a traditional transvenous device. Future advances in the technology of leadless pacing will hopefully allow multichamber pacing (and multisite pacing within a chamber) with all the sophistication of current transvenous systems. Perhaps, leadless pacing can even be combined with a subcutaneous ICD in the same patient. Keywords: Leadless pacing, subcutaneous ICDs Background Cardiac Pacemakers: The heart generates its own electrical activity, and this intrinsic heart beat underlies the rhythmic contraction of the heart. When there is a problem with the origin or spread of this electrical activity, the heartbeat, and therefore the pumping function of the heart, may be impaired. In such situations, the electrical function of the heart may be restored by external electrical stimulation by devices called pacemakers. The first cardiac pacemakers were developed around 1960. They have traditionally involved 2 basic components: a generator that houses the battery and circuitry, and pacing wires (leads) that connect the generator to the heart for transmission of electrical pulses to the heart. Early pacing systems involved a large generator connected to pacing wires sutured on to the outside of the heart. These early systems were replaced by trans-venous systems, with pacing wires (leads) that pass through the blood vessels (veins) into the heart, and connect to the generator typically placed under the skin in the chest. Over time, the generators have become smaller, with a longer battery life and more sophisticated features. For instance, modern pacemakers can stimulate multiple chambers of the heart in a synchronized fashion, and can alter the pacing rate based on the perceived needs of the patient.

Cardiac Defibrillators: Cardiac arrest is sudden cessation of cardiac activity with collapse, that will lead to death (Sudden Cardiac Death) without prompt intervention. Cardiac arrest is most commonly due to rapid rates in the lower chambers of the heart (ventricular fibrillation); the most effective intervention for this lethal rhythm is defibrillation i.e. delivery of a high energy shock to the heart to restore normal rhythm. People who have survived a cardiac arrest or who are at high risk for developing one would benefit from placement of devices called implantable cardioverter defibrillators (ICDs), which can continuously monitor the patient s rhythm, rapidly detect any lethal ventricular rhythm that occurs, and terminate it by prompt delivery of a high energy shock. In an analogous fashion to pacemakers, early ICDs, which were developed around 1980, required a surgical procedure (thoracotomy) to place large patches on the outside of the heart connected to large pulse generators placed within the abdomen. These have since evolved to trans-venous systems involving one or more leads that traverse the veins into the heart, connected to much smaller devices placed under the skin in the chest. Early on, patients that needed both pacing and defibrillation had 2 separate systems placed. However, current defibrillators have the capability to function as sophisticated pacemakers, and therefore only one device is required. Complications associated with intra-vascular leads: As noted above, most current pacemaker and ICD systems involve placement of lead(s) transvenously into the heart, connected to a pulse generator. Potential acute complications associated with vascular access and transvenous placement of leads include pneumothorax (collapse of the lung due to accumulation of air around it), hemothorax (blood collection around the lung), cardiac tamponade (blood collection around the heart impeding its normal function) and lead dislodgement. In addition, vascular access may be difficult or limited in some patients. In the long term, intravascular leads can be associated with multiple complications such as vascular occlusion, lead malfunction (conductor fracture or insulation breach), infection and valvular regurgitation. Most of these issues necessitate lead extraction, which can be associated with significant morbidity and mortality. In fact, intravascular leads are considered the weakest link of the pacing or ICD system. Recent advances in pacing and ICDs include the development of subcutaneous ICDs and leadless pacing which eliminate the need for intravascular leads and their associated complications. Cardiac resynchronization therapy (CRT) is a form of pacing designed to synchronize activation of the ventricles in certain patients with heart failure. CRT typically involves pacing the left ventricle through a lead that is delivered transvenously to a branch of the coronary venous system (the venous system of the heart) to pace the left ventricle from the epicardium (outer aspect of the heart). Ideally, the pacing lead should be placed close to the area of the left ventricle that has maximal dys-synchrony; however, with the transvenous coronary vein approach, where the lead can be placed is limited by the anatomy of the coronary venous system. To avoid this limitation, studies have tested leads delivered to the endocardium (inner aspect) of the left ventricle. However, embolic complications (that can cause strokes) are a potential risk with this approach. Recent advances in leadless pacing offer promise for endocardial left ventricular pacing for CRT at the desired site, while minimizing the embolic risks associated with indwelling leads in the arterial system. Subcutaneous ICDs An entirely subcutaneous defibrillator (S-ICD system, Cameron Health, Inc., San Clemente, California) has been developed and tested in humans. The S-ICD system includes a single lead implanted subcutaneously in the chest parallel to the breast bone, which is connected to the pulse generator

implanted subcutaneously in the left side of the chest. The system can deliver a defibrillating pulse of up to 80J (transvenous ICDs typically can deliver up to 35-40J). Subcutaneous ICDs are particularly useful in patients with difficult or absent venous access. They should also be considered in patients at high risk for blood stream infection, such as those with indwelling intravascular catheters. In addition, they should also be considered in young patients who require defibrillators, since they eliminate the physical stress on leads associated with cardiac motion. The lack of demand pacing in these systems contraindicates their use in patients who require consistent pacing support. In addition, certain fast ventricular arrhythmias may be terminated by rapid pacing without the need for a high energy shock, and in such patients traditional transvenous ICD systems which have this capability would be preferred. Leadless cardiac pacemakers There are two types of leadless pacemakers. The first are self-powered devices implanted in the heart. The second type involves receiver electrodes implanted within the heart that are powered by a power source implanted outside the heart in the chest. The leadless cardiac pacemaker (Nanostim Inc, Sunnyvale CA) is a self-powered cylindrical device, about 4 cm long with a diameter of <6mm, that is implanted in the heart. The device includes the pacemaker electronics, battery and electrodes and is delivered to the heart using a delivery catheter. The device functions as a basic single chamber pacemaker that can alter the pacing rate based on the perceived needs of the patient. As discussed above, traditional pacemakers involve leads that traverse the veins to connect the generator to the heart. Implanted leads may sometimes need to be removed, due to infection of the pacing system, lead failure or vascular complications. Removal of pacing wires that have been in place for a long time can be quite challenging and risky, and can result in life-threatening bleeding. Leadless pacemakers would eliminate these problems since they do not require leads that traverse the vascular system. Initial short term studies have demonstrated the acute safety and feasibility of this approach in humans. Obviously, long term reliability and safety have to be demonstrated in larger numbers of patients before this technology is ready for prime time. The current version of the leadless pacemaker has only the most basic functions whereas modern traditional pacemakers have more sophisticated features. There are technical challenges associated with implantation that must be carefully handled. Dislodgement and migration of the implanted pacemaker to other sites (embolization) is a potential concern. When the battery of the implanted leadless pacemaker is exhausted, a new implant is necessary, with all the potential risks associated with this. Though retrievability of the device has been demonstrated in the short term, it is not known if it will be feasible to safely retrieve the old device after it has been in place for years. If the old device is left in place, it is not known what the long term effects of this will be. Leadless pacemaker for cardiac resynchronization therapy Leadless pacing is being explored as an option for endocardial left ventricular pacing for cardiac resynchronization in heart failure patients. The traditional approach of placement of a lead in a branch of the venous system of the heart has inherently limited options. Leadless pacing could potentially target the optimal area of the left ventricle for pacing. As mentioned above, in addition to self-powered devices, leadless pacing can also involve receiver electrodes implanted within the heart that are powered by a power source implanted outside the heart

in the chest. An ultrasound-based cardiac stimulation pacing system (wireless cardiac stimulation[wics]- LV system, EBR Systems Inc.) has been developed to deliver left ventricular pacing in conjunction with a traditional transvenous system. The system includes a transmitter implanted subcutaneously in the chest that transfers energy to a small receiver electrode(s) implanted in the endocardium of the left ventricle. The transmitter is connected to a pulse generator (battery) that can be placed in the side of the chest or in the abdomen. The system relies on RV pacing pulses from the transvenous implant to trigger LV pacing. The advantage with this approach is the ability to deliver the electrode(s) to the optimal site in the LV and the potential option for multisite LV pacing. Conclusion Most current pacemaker and ICD systems involve placement of lead(s) transvenously into the heart, connected to a pulse generator. Vascular access may be difficult or limited in some patients, and intravascular leads can be associated with multiple complications such as infection, lead malfunction and vascular occlusion. Recent advances in pacing and ICDs include the development of subcutaneous ICDs and leadless pacing. Subcutaneous ICDs do not require a transvenous access or lead, and have become an important option for patients with indications for ICDs who have limited or difficult vascular access or have a significant risk of infection with this approach. In addition, subcutaneous ICDs can be offered as an alternative to transvenous ICDs in young patients. Leadless pacing is evolving as a new approach to pacing that can avoid or mitigate the issues associated with intravascular leads. Selfpowered leadless cardiac pacemakers have been shown to be a safe and feasible option for patients requiring single chamber pacing. In addition, leadless ultrasound-based pacing has been shown to provide effective left ventricular pacing for cardiac resynchronization therapy in conjunction with a traditional transvenous device. Future advances in the technology of leadless pacing will hopefully allow multichamber pacing (and multisite pacing within a chamber) with all the sophistication of current transvenous systems. Perhaps, leadless pacing can even be combined with a subcutaneous ICD in the same patient.

Bibliography: 1. Crozier I, Smith W. Modern device technologies. Heart, lung & circulation 2012;21:320-7. 2. Aziz S, Leon AR, El-Chami MF. The Subcutaneous Defibrillator: A Review of the Literature. Journal of the American College of Cardiology 2014;63:1473-1479. 3. Kapa S, Bruce CJ, Friedman PA, Asirvatham SJ. Advances in cardiac pacing: beyond the transvenous right ventricular apical lead. Cardiovascular therapeutics 2010;28:369-79. 4. Reddy VY, Knops RE, Sperzel J et al. Permanent Leadless Cardiac Pacing: Results of the LEADLESS Trial. Circulation 2014;129:1466-71. 5. Auricchio A, Delnoy PP, Regoli F et al. First-in-man implantation of leadless ultrasound-based cardiac stimulation pacing system: novel endocardial left ventricular resynchronization therapy in heart failure patients. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology 2013;15:1191-7.

Author biography: Dr. Harish Doppalapudi is an Assistant Professor of Medicine at the University of Alabama at Birmingham (UAB) in Birmingham, Alabama, USA. After graduating in medicine from Guntur Medical College in Guntur (AP, India) in 1997 as the best outgoing student of the college and the university, he completed residency training in internal medicine at UAB, where he went on to complete fellowships in cardiovascular disease and clinical cardiac electrophysiology. He has been on faculty in the electrophysiology section of the cardiovascular division at UAB since 2007, and is the Director of the Fellowship Training Program in clinical cardiac electrophysiology. His clinical practice encompasses all aspects of electrophysiology such as complex ablation, lead extraction, pericardial interventions, and device placement and troubleshooting. He is actively involved in medical student teaching as the codirector of the cardiovascular module. He has been recognized with numerous awards for his teaching contributions to medical students, residents and fellows. He is a member of the core clinical faculty for internal medicine and cardiovascular disease. He has several publications in electrophysiology including the first description of two idiopathic VT syndromes (posterior papillary muscle VT and VT from the crux of the heart) and has coauthored multiple book chapters. He lives in Birmingham with his wife, Harini Ganga, who practices internal medicine at the Bessemer Clinic, and two sons, Siddharth and Nishanth.