Original Article Three-dimensional printing automatic registration navigational template for mandibular angle osteotomy surgery

Similar documents
ORIGINAL ARTICLE INTRODUCTION. Han-su Yoo, Sewoon Choi, Jeemyung Kim

Case Report Decompression of the inferior alveolar nerve to treat the pain of the mandible caused by fibrous dysplasia-case report

Lower face reduction with full-thickness marginal ostectomy of mandibular corpus-angle followed by corticectomy

Quantitative Determination of

Validation of a fibula graft cutting guide for mandibular reconstruction: experiment with rapid prototyping mandible model

ORAL AND MAXILLOFACIAL SURGERY. Department of Imaging & Pathology, Faculty of Medicine, KU Leuven, Belgium 2

Interesting Case Series. Virtual Surgical Planning in Orthognathic Surgery

The free fibular flap is one of the most common techniques. Original Article Reconstructive

Application of augmented reality for inferior alveolar nerve block anesthesia: A technical note

Design & Manufacturing of Implant for reconstructive surgery: A Case Study

CASE REPORT. CBCT-Assisted Treatment of the Failing Long Span Bridge with Staged and Immediate Load Implant Restoration

Research report for MSc Dent. University of Witwatersrand. Faculty of health science. Dr J Beukes. Student number: h

The Application of Cone Beam CT Image Analysis for the Mandibular Ramus Bone Harvesting

Dolphin 3D Imaging 11.7 beta

Introduction. Yanju Xiao 1 Xiumei Sun. Guomin Wu 1

Unilateral intraoral vertical ramus osteotomy based on preoperative three-dimensional simulation surgery in a patient with facial asymmetry

Additive manufacturing in maxillofacial reconstruction

Finite Element Modeling of Complete Unilateral Cleft and Palate using MIMICS

Reconstruction of a Mandibular Osteoradionecrotic Defect with a Fibula Osteocutaneous Flap.

Customised Design of a Patient Specific 3D Printed Whole Mandible Implant

Assessment of Relapse Following Intraoral Vertical Ramus Osteotomy Mandibular Setback and Short-term Immobilization

Precision of fibula positioning guide in mandibular reconstruction with a fibula graft

Postoperative Evaluation on SSRO performed by Short Lingual Osteotomy and IVRO

Intramembranous autogenous bone graft is the gold

Case Report. Orthognathic Correction of Class II Open Bite. Using the Piezoelectric System and MatrixORTHOGNATHIC Plating System.

DETAILING THE SOFTWARE AIDED DESIGNING OF 3-D MODEL FOR MANDIBULAR RECONSTRUCTION: A CASE REPORT

MEDPOR. Oral maxillofacial surgery

Digital Smile Design using the M Proportions and GPS 2D to 3D Digital Facebow: Clinical Case 1

Variations in the anatomical dimensions of the mandibular ramus and the presence of third molars: its effect on the sagittal split ramus osteotomy

Chapter 2. Material and methods

UCL Repair: Emphasis on Muscle Dissection and Reconstruction

Orthodontic-prosthetic implant anchorage in a partially edentulous patient

Sample Case Report Orthognathic Demo 2 Surgeon Name Orthognathic surgery

SimPlant OMS is a software platform developed by Materialise Dental for the very specific purpose of allowing digital orthognathic planning and

BUILDING A. Achieving total reconstruction in a single operation. 70 OCTOBER 2016 // dentaltown.com

A New External Landmark for Mental Foramen

Three-dimensional analysis of the anterior loop of the inferior alveolar nerve in relation to the growth pattern of the mandibular functional subunit

Application of digital medical techniques on interdisciplinary talent education of stomatology and mechanical engineering

Cephalometric Analysis

3D-MODEL CUSTOM-MADE MODELS SEGMENTATION AND PRODUCTION SERVICE OF BONE MODELS WITH HIGHEST 3D PRINTING RESOLUTION

doi: /j.issn

Mixed-reality simulation for orthognathic surgery

Characterizing scaphoid nonunion deformity using 2-D and 3-D imaging techniques ten Berg, P.W.L.

For true visualisation

Post-operative stability of the maxilla treated with Le Fort I and horseshoe osteotomies in bimaxillary surgery

Professor, Department of Craniofacial Orthodontics, Chang Gung Memorial Hospital,

THREE-DIMENSIONAL COMPUTED TOMOGRAPIDC ANALYSIS FOR PLACEMENT OF MAXILLOFACIAL IMPLANTS AFTER MAXILLECTOMY

3. The Jaw and Related Structures

Bony hump reduction is an integral part of classic

3D workflows in orthodontics, maxillofacial surgery and prosthodontics van der Meer, Wicher

Diagnosis and Treatment of a Large Central Ossifying Fibroma of the Mandible. Clinical Case

Cover Page. The handle holds various files of this Leiden University dissertation.

Case Report Three-dimensional printing technology facilitates customized pelvic prosthesis implantation in malignant tumor surgery: a case report

Simultaneous gap arthroplasty and intraoral distraction and secondary contouring surgery for unilateral temporomandibular joint ankylosis

Original Article Osteotomy and osteosynthesis in complex segmental genioplasty with double surgical guide

Screw hole-positioning guide and plate-positioning guide: A novel method to assist mandibular reconstruction

Novel three-dimensional position analysis of the mandibular foramen in patients with skeletal class III mandibular prognathism

Clinical Study Open Reduction of Subcondylar Fractures Using a New Retractor

A Useful Reference Guide for the Stem Anteversion During Total Hip Arthroplasty in the Dysplastic Femur

Xelis Dental - What New in

Reconstruction of large mandibular defects

Upper arch. 1Prosthodontics. Dr.Bassam Ali Al-Turaihi. Basic anatomy & & landmark of denture & mouth

University Journal of Surgery and Surgical Specialties

Case Study. Micrognathia Secondary to Pierre Robin Sequence. Treated with distraction osteogenesis using an internal mandible distractor.

Evaluation of maxillary protrusion malocclusion treatment effects with prosth-orthodontic method in old adults

Dental implant placement is a sensitive surgical

Original Research THE USE OF REFORMATTED CONE BEAM CT IMAGES IN ASSESSING MID-FACE TRAUMA, WITH A FOCUS ON THE ORBITAL FLOOR FRACTURES

Oral cavity landmarks

Comparative analysis of the stress distribution in five anatomical types of maxillary central incisor

Non-Discrimination Statement and Multi-Language Interpreter Services information are located at the end of this document.

International Symposium on the Applications of 3-D Printing (Rapid Prototyping) in Orthopaedics

Sensitivity of a Method for the Analysis of Facial Mobility. II. Interlandmark Separation

Inferior alveolar nerve cutting; legal liability versus desired patient outcomes

Objective: The antilingular prominence (AP) is a well-known landmark used during planning

Case Report. RapidSorb Rapid Resorbable Fixation System. Ridge augmentation in a one-step surgical protocol.

Clinical Accuracy of Portrait 3D Surgical Simulation Platform in Breast Augmentation. Ryan K. Wong MD, David T Pointer BS, Kamran Khoobehi MD FACS

3D IMAGING IN ORTHODONTICS: TECHNIQUES, USE AND LANDMARK IDENTIFICATION

The relative position of the inferior alveolar nerve in cadaveric hemi-mandibles

A lingual orthodontic case with 3M Incognito Appliance System combined with orthognathic surgery.

Mandibular Distraction Micro Zurich II Distractors

Introduction of FIREFLY Technology

Predicting the Position of the Femoral Head Center

Fibular Bone Graft for Nasal Septal Reconstruction: A Case Report

Synthes ProPlan CMF. Planning service and patient-specific products for craniomaxillofacial surgery.

Int J Clin Exp Med 2017;10(8): /ISSN: /IJCEM

Intraoral mandibular distraction osteogenesis in facial asymmetry patients with unilateral temporomandibular joint bony ankylosis

DIOnavi. Brochure Ver.2. Product Introduction: DIOnavi. Clinical Case Report

Utilizing Digital Treatment Planning and Guided Surgery in Conjunction with Narrow Body Implants. by Timothy F. Kosinski, DDS, MAGD

Digital, but without loss of function

PATIENT SPECIFIC PLATES FOR MANDIBLE Custom made plates for trauma and reconstruction

Dr.Mikulás Krisztina. Fabrication of the trial denture, and the try in procedure

Anatomical examination of the fibula: digital imaging study for osseointegrated implant installation

Journal of International Academy of Forensic Science & Pathology

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

CT SCAN PROTOCOL. Shoulder

Virtual model surgery and wafer fabrication for orthognathic surgery

Orthodontic and Orthognathic Surgical Correction of a Skeletal Class III Malocclusion

ORIGINAL ARTICLE. A Novel Technique for Malar Eminence Evaluation Using 3-Dimensional Computed Tomography

For many years, patients with

IPS Implants. Mandible Reconstruction.

Transcription:

Int J Clin Exp Med 2016;9(7):13065-13069 www.ijcem.com /ISSN:1940-5901/IJCEM0021585 Original Article Three-dimensional printing automatic registration navigational template for mandibular angle osteotomy surgery Kun Qian 1*, Jin Shi 2*, Hui Zhao 1, Jing Xu 1, Yikuan Du 1, Wenhua Huang 1 1 Department of Anatomy, Guangdong Provincial Key Laboratory of Medical Biomechanics, School of Basic Medical Sciences, Southern Medical University, Guangzhou 510515, Guangdong, China; 2 Department of Neurosurgery, Nanfang Hospital of Southern Medical University, Guangzhou, Guangdong, China. * Equal contributors. Received December 10, 2015; Accepted March 19, 2016; Epub July 15, 2016; Published July 30, 2016 Abstract: The prominent mandibular angle is considered as unattractive in Asians because it gives the face a square, coarse, and muscular appearance. Mandibular angle osteotomy (MAO) is commonly used to correct prominent mandibular angles through an intraoral approach. This study aims to improve the accuracy and safety of surgery for MAO through optimized design of 3D printing navigational template. Computed tomographic (CT) data were imported into Mimics 14.0 software and surgical simulations were performed. An automatic registration navigational template was designed and fabricated. The osteotomy operations were performed on ten fresh head specimens with individualized navigational templates. Measurements and statistical analysis of three-dimensional models were performed on virtual and actual post-operations. The results were evaluated using paired t-test. No significant differences (P > 0.05) were observed between the virtual and actual post-operations. In conclusion, the MAO can be performed accurately and safely using the 3D printing automatic registration navigational template. Keywords: Three-dimensional printing, mandibular angle osteotomy, automatic registration, navigational surgical template Introduction A prominent mandibular angle is considered to be unattractive in Asians because it gives the face a square, coarse, and muscular appearance [1]. Mandibular angle osteotomy (MAO) is commonly used to correct prominent mandibular angles through the intraoral approach. Especially in the south of China, it has become popular and considered as the facial bone contouring surgery, which reduces the lower facial width. However, limited vision in the operative site may lead to difficulties or complications, such as condylar fracture, inferior alveolar nerve injury, over-correction/under-correction, facial asymmetry, and formation of a second mandibular angle during surgery [2]. With the development of computer-aided design and three-dimensional printing technology, the navigational templates have been applicable for the MAO in the past two years [3, 4]. The use of navigational templates mainly aims to make the actual operation identical to the pre-surgical planning from the computer-assisted design. In the present study, we modified the navigational template and evaluate its advantage in accuracy based on ten fresh head specimens. Materials and methods The ten fresh head specimens were provided by the Invasive Surgical Anatomy Department of Southern Medical University and Department of Neurosurgery of Nanfang Hospital of Southern Medical University. The instruments used in the analysis included general surgical instruments, maxillofacial plastic instruments (ZXQ-1; Xia Long Medical Instrument Manufacturing Co., Ltd.; Shao shan; People s Republic of China ) and a digital camera (Canon 50D; Canon, Inc., Tokyo, Japan).

Figure 1. Observation of mandibular ramus and mandibular width by using Mimics software. A. Bilateral gonial angle, bilateral gonion displacement distance, bilateral length of mandibular ramus were measured in Mimics software. B. The mandibular width was measured in Mimics software. 3D models, surgical simulation and virtual postoperative measurements All the specimens were analyzed by using the CT imaging (SOMATOM Definition CT, Siemens Medical Systems, Germany) with 0.6 mm slice thickness. The CT images were stored as the digital imaging and communicated in medicine (DICOM) format files. All the images were then imported into Mimics software (version 14.0; Materialise, Leuven, Belgium) for 3D reconstruction. The mandibular angle on one side was performed via the osteotomy operation using the software according to the designed osteotomy line. Next the facial midline is set as the axis of symmetry and the other side line was obtained in reference to the mirror image of the cut side. After the virtual MAO, seven sets of data, including bilateral gonion displacement distance (Go-Go ), bilateral gonial angle (RG-Go -MG), bilateral length of mandibular ramus (R-Go ) and the mandibular width (Go - Go ), which were analyzed by using the Mimics software (Figure 1A, 1B). Production of navigational templates The complete mandibular 3D models were exported in the format of.stl and imported into the 3-matic format (version 6.0; Materialise, Leuven, Belgium) for the template design. The whole design procedure included marking, thickening, boolean union, and local smoothing. The marked template includes two parts, including the first part (which covers the mandibular angle) and the second part (which covers the second premolar and the first molar for template registration). Then the two parts of the templates were thickened to 3 mm and 2 mm, respectively. Then, the thicked first and second parts were combined by boolean union. Finally, the local smoothing was performed on the lateral side of the template. The original templates were exported in the format of.stl and imported into Mimics software for the same osteotomy operation. A square window (2 mm of side length) is opened in the template to check whether registration is good when the first molar operation was performed. The designed navigational template was produced by a 3D printer with the printing precision of 0.1 mm (MakerBot Replicator 2X, USA). Surgical procedures For the ten fresh head specimens, bilateral MAO was performed through the intraoral approach. The registration parts of templates were attached with the second premolar and first molar. The masseter was then stripped from the mandibular ramus to the body, and the inferior border was freed from the attached muscle [5]. Naturally, the remaining parts of templates were positioned on the outer surface of the mandibular angle. Then, the bilateral MAO was easily performed along the lower edge of the navigational template with an oscillating saw following the same registration procedure above (Figure 2A-C). Postoperative measurements All of the specimens received CT scans post operation and the images were imported into 13066 Int J Clin Exp Med 2016;9(7):13065-13069

Figure 2. Surgical procedures. A. Incision of oral mucosa. B. Embed the upper part of template in teeth and observe (red square) whether the template fit closely with teeth or not. C. Template positioned on the outer surface of the mandibular angle and cut the mandibular angle along the osteotomy line of the template with an oscillating saw. Mimics software for 3D reconstruction. Then, the bilateral gonial angle, bilateral gonion displacement distance, bilateral length of mandibular ramus and the mandibular width were analyzed by using the Mimics software. Statistical analysis The paired t-test was used to determine statistical differences in seven sets of data between the virtual post-operation and actual post-operation for the ten fresh head specimens. Data were reported as mean ± SD. All the data were analyzed by using SPSS 20.0 software (SPSS, Chicago, IL, USA). Results No significant differences (Table 1, P > 0.05) were observed between the virtual post-operation and actual post-operation in seven sets of data for the ten fresh head specimens. The mean deviations in gonial angle on the left and right sides were 0.16 ± 0.57 and 0.59 ± 0.98, respectively (Table 1). The maximum deviation was no more than 1.03 and 2.86, respectively (Table 1). The mean deviations in gonial displacement distance on the left and right sides were 0.27 ± 0.48 and 0.25 ± 0.40 mm, respectively (Table 1). The maximum deviation was no more than 0.81 and 0.83 mm, respectively (Table 1). The mean deviations in length of mandibular ramus on the left and right sides were 0.04 ± 0.54 and 0.22 ± 0.45 mm, respectively (Table 1). The maximum deviation was no more than 0.87 and 1.00 mm, respectively (Table 1). The mean deviation in mandibular width was 0.26 ± 0.70 mm (Table 1). The maximum deviation was no more than 0.95 mm (Table 1). Discussion Comparisons for the Orientals and Westerners, there are differences in cultural backgrounds and esthetic views. A square face contour gives a strong, masculine, and unattractive impression, which generally is regarded as an aesthetic problem for women and even for some men in Oriental culture. Also the over-growth of the mandibular angle is more common in Asians. Therefore, more and more people would prefer their face to be slender and oval-shaped with smooth curves and outlines. The MAO for prominent mandibular angle was firstly reported by Adams in 1949. He resected hyperostotic bone and the medial portion of 13067 Int J Clin Exp Med 2016;9(7):13065-13069

Table 1. The differences, mean ± SD, maximum, P value of seven sets of data L-Vir-A versus L-Act-A R-Vir-A versus R-Act-A L-Vir-D versus L-Act-D R-Vir-D versus R-Act-D L-Vir-L * versus L-Act-L * R-Vir-L * versus R-Act-L * Vir-W versus Act-W 1 0.52 0.86 0.65 0.38 0.55 0.01 0.75 2 0.26 0.68 0.81 0.35 0.26 0.24 0.95 3 1.03 0.38 0.41 0.46 0.87 0.39 0.77 4 0.72 2.86 0.58 0.63 0.54 0.48 0.32 5 0.42 0.74 0.78 0.83 0.33 0.11 0.82 6 0.39 0.57 0.37 0.17 0.30 0.26 0.36 7 0.22 0.53 0.27 0.35 0.83 0.67 0.38 8 0.33 1.04 0.11 0.39 0.24 1.00 0.65 9 0.39 0.31 0.55 0.37 0.33 0.17 0.91 10 0.78 0.44 0.31 0.21 0.44 0.52 0.89 Mean ± SD (absolute values) 0.16 ± 0.57 0.59 ± 0.98 0.27 ± 0.48 0.25 ± 0.40 0.04 ± 0.54 0.22 ± 0.45 0.26 ± 0.70 Maximum (absolute values) 1.03 2.86 0.81 0.83 0.87 1.00 0.95 P value 0.409 0.090 0.116 0.081 0.843 0.163 0.270 Vir = Virtual Post-operation, Act = Actual Post-operation, L = Left, R = Right, A = Gonial angle, D = Gonion displacement distance, L * = Length of mandibular ramus, W = Mandibular width. masseter muscle under direct vision through an external approach [6]. Later, many researchers have improved or modified the operative techniques for better correction [7-10]. The main problem of MAO is the limitation of the apparatus, limited vision and the individual variation during the surgery, which makes it extremely difficult for the surgeon to cut the mandibular angle as computer-aided design in pre-operation, Therefore, we have decided to apply a low-cost navigational template to solve this problem. In the recent years, the 3D-print technology has been developed rapidly, especially in the clinical. Although the navigational template fabricated by 3D-print technology has been applied frequently to other surgery, the application in MAO is relatively less common. Uncertain registration is the biggest problem. Only the templates are in right location, the surgical accuracy could be guaranteed. But the obvious bony anatomical marks ware not in this region, therefore, when the templates are used in the operation, surgeons can t ensure that the templates ware in the right location. The surgeons generally believe that the templates are in the right location when the templates can t move. But the cause of this result may be soft tissue blocking, rather than bony landmarks. In this study, we designed osteotomy lines based on 3D-reconstructed images of the patients mandible. In 3D-images of the mandible, inferior alveolar nerve canal were displayed clearly. The osteotomy lines could be designed to avoid nerve canal, and make it safe. We confirmed the osteotomy line based on the surgeon s knowledge of the mandibular anatomy, clinical examination and cognition of aesthetics. Subsequently, we designed automatic registration navigational templates with the same osteotomy lines. In the process of actual operation, due to narrow surgical vision and space, the templates may be unable to be embedded preoperative designed position and be in displacement, therefore, we designed the part of automatic registration. It is integrated with part of osteotomy and this design will ensure that when its location is right, other parts of the templates are right. The two parts are thickened to 3 mm and 2 mm, respectively, based on their better hardness, stability and wider vision. In order to ensure that the template fit closely with teeth, we opened a window in the automatic registration part of template to observe the position of the template. After the mandibular angle exposed fully in the surgery, the upper part of template is embed in teeth and lower part of it is attached to the surface of mandible. At the end, the mandibular angle is cut along the osteotomy line of the template with an oscillating saw. For the accuracy of surgery, the results were satisfied. Certainly, bone abrasion occurred when perform osteotomy with saw. And adequate exposure of soft tissues must be performed for fitting of the template. Through reference to the mirror image on the contralateral mandible, we designed the contralateral cut- 13068 Int J Clin Exp Med 2016;9(7):13065-13069

ting line. This approach may guarantee the symmetry of bilateral mandibular angles. The surgeons can easily determine the cut line at the surgical site and perform MAO with precision. Our results showed that the 3D models of the virtual post-operation and actual post-operation were almost consistent. It can be guaranteed that ostectomy will be performed well as the pre-operative design. In the software the mandibular canal can be visualized, which is helpful in the design of an osteotomy line that avoids injury to the inferior alveolar nerve. The 3D printing-navigational template can also meet the needs of the individual operation. Subsequently, it provides a visualized method for patients to easily understand the operation and helps young plastic surgeons to make MAO safer, more convenient and efficient. This study described an optimized design to manufacture a navigational template for MAO. The results of this study also suggest that the automatic registration 3D navigational template further improved the accuracy and safety of MAO, according to the optimal preoperative planning. This technology realizes the personalized MAO with improved surgical results and can be further explored for improving clinical applications. Acknowledgements This study was supported in part by the Science and Technology Project of Guangdong Province (Grant No. 2015B010125005) and in part by the Guangzhou science and technology planning Project (Grant No. 2014J4100153). Disclosure of conflict of interest None. References [1] Hong SO, Ohe JY, Lee DW. Salvage of the condylar fracture: complication management of mandibular angle osteotomy. J Craniofac Surg 2014; 25: e582-584. [2] Kane AA, Lo LJ, Chen YR, Hsu KH, Noordhoff MS. The course of the inferior alveolar nerve in the normal human mandibular ramus and in patients presenting for cosmetic reduction of the mandibular angles. Plast Reconstr Surg 2000; 106: 1162-74. [3] Ye N, Long H, Zhu S. The accuracy of computer image-navigational template for mandibular angle osteotomy. Aesthetic Plast Surg 2014; 39: 117-123. [4] Rong Q, Zhu S, Chen S, Zhang X. Individual stereolithographic template-navigational curved osteotomy for unilateral prominent mandibular angle: a case report. J Craniofac Surg 2013; 24: e289-e292. [5] Satoh K. Mandibular contouring surgery by angular contouring combined with genioplasty in orientals. Plast Reconstr Surg 1998; 101: 461-472. [6] Adams WA. Bilateral hypertrophy of the masseter muscle: an operation for correction (case report). Br J Plast Surg 1949; 2: 78. [7] Baek SM, Baek RM, Shin MS. Refinement in aesthetic contouring of the prominent mandibular angle. Aesthetic Plast Surg 1994; 18: 283-289. [8] Ying Z, Jianlin F, Lijian Z. Lower face remodeling by mandibular angle ostectomy. Eur J Plast Surg 2006; 29: 67-71. [9] Ying B, Wu S, Yan S, Hu J. Intraoral multistage mandibular angle ostectomy: 10 years experience in mandibular contouring in Asians. J Craniofac Surg 2011; 22: 230-232. [10] Pozzer L, Olate S, Cavalieri-Pereira L, de Moraes M, Albergaria-Barbosa JR. Influence of the design in sagittal split ramus osteotomy on the mechanical behavior. Int J Clin Exp Med 2014; 7: 1284-1288. Address correspondence to: Dr. Wenhua Huang, Department of Anatomy, Guangdong Provincial Key Laboratory of Medical Biomechanics, School of Basic Medical Sciences, Southern Medical University, Guangzhou 510515, Guangdong, China. Tel: +86-020-61648181; E-mail: huangwenhgd@sina. com 13069 Int J Clin Exp Med 2016;9(7):13065-13069