onotube TRIAX EXTERN AL FIXATION SYSTEM

Similar documents
TRIAX EXTERNAL FIXATION SYSTEM

Monotube Triax. External Fixation System. External Fixation. Operative Technique

EXTERNAL FIXATION SYSTEM

EXTERNAL FIXATION SYSTEM

Hoffmann II Compact External Fixation System

Hoffmann II External Fixation System

Hoffmann II Compact External Fixation System. Modular System for

Monolateral External Fixation System for Trauma and Orthopaedics

External Fixator Brochure

Knee spanning solutions

TIPMED EXTERNAL FIXATION SYSTEMS

Hoffmann II MRI External Fixation Systems. Hoffmann II MRI Hoffmann II Compact MRI Modular Systems for Upper Extremity Lower Extremity Pelvis

Hoffmann II Micro External Fixation System. Indications for the Hand

Hoffmann II Micro External Fixation System

Hoffmann LRF Circular External Fixation. Operative technique

EXTERNAL FIXATION SYSTEM OPERATIVE TECHNIQUE

Surgical Technique. Targeter Systems Overview

MEFiSTO. Monolateral External Fixation System for Trauma and Orthopaedics.

AxSOS Locking Plate System

QUICK REFERENCE GUIDE. The XCaliber Meta-Diaphyseal Fixator

MEFiSTO. Monolateral External Fixation System for Trauma and Orthopaedics.

Technique Guide. The Distraction Osteogenesis Ring System. Nonarticular tibia frame.

TransFx External Fixation System Large and Intermediate Surgical Technique

Small External Fixator Nonspanning Wrist Frame. For the treatment of wrist fractures.

TransFx External Fixation System Large and Intermediate Surgical Technique

Elbow Hinge Fixator. Guided Flexion/Extension for Unstable Elbow Fractures.

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

QUICK REFERENCE GUIDE. The PreFix Fixator (92000 Series) ALWAYS INNOVATING

Mini External Fixator.

LCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system.

DFS STANDARD FIXATOR DFS ANKLE CLAMP DFS T-CLAMP

External Skeletal Fixation (ESF)

Surgical Technique. 3.5mm and 4.5mm Lateral Proximal Tibia Locking Plates

Small External Fixator Wrist Spanning Frame. For the treatment of wrist fractures.

Hoffmann 3 Modular External Fixation. Operative technique

Medical Devices HUMERUS. WRIStX

Surgical Technique. Anterolateral and Medial Distal Tibia Locking Plates

Surgical Technique. Distal Radius and Foot

LCP Low Bend Medial Distal Tibia Plates 3.5 mm. Anatomic plates with low profile head for intra- and extraarticular fractures.

External Distal Radius Fixator. Supplement to the 8 mm rod fixator system

Humerus Block. Discontinued December 2016 DSEM/TRM/0115/0296(1) Surgical Technique. This publication is not intended for distribution in the USA.

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plate Aiming Instruments. Part of the 3.5 mm LCP Percutaneous Instrument System.

OPERATIVE TECHNIQUE. Knee Hinge (LRS Advanced System)

Choice, Simplicity, Transition. TransFx External Fixation System Small and Mini Surgical Technique

Technique Guide. LCP Proximal Femoral Hook Plate 4.5/5.0. Part of the LCP Periarticular Plating System.

M.I.S. MAKE IT SMART IN ONE SYSTEM. Surgical Technique. Hip Knee Spine Navigation

Biomet Carbon Rail Deformity System. Surgical Technique

pediatric orthopedic implants fixator

Large External Fixator Delta Frame Ankle Bridge. For staged fixation of the distal tibia.

Introduction to the Taylor Spatial Frame Hardware. Trademark of Smith & Nephew. Certain marks Reg. US Pat. & TM Off.

OPERATING MANUAL AND TECHNIQUE GUIDE FOR TITANIUM FEMORAL AND TIBIAL NAILING SYSTEMS

OPERATIVE TECHNIQUE. Limb Reconstruction System. Part B: Correction of Deformities. By Dr. S. Nayagam

Large External Fixator Delta Frame Ankle Bridge. Using pin clamps with outrigger posts.

Operative Technique. by PROF. NAYAGAM. LIMB RECONSTRUCTION SYSTEM Part B: Correction of Deformities

LCP Distal Tibia Plate

Technique Guide. Adjustable Distal Radius Fixator. Part of the Synthes External Fixation Systems.

Surgical Technique International Version

OPERATIVE TECHNIQUE. The Ring Fixator System. The Sheffield Ring Fixator - Limb Reconstruction. and Complex Trauma. By Prof. M.

GAMMA LOCKING NAIL INSTRUMENTS OPERATIVE TECHNIQUE

QUICK REFERENCE GUIDE. Arthrodiatasis. Articulated Joint Distraction

EBI FIX DYNAFIX SYSTEM VISION EXTERNAL FIXATION SURGICAL TECHNIQUE. Patent 6,277,119

LCP Superior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

Large Distractor Femur

VLIFT System Overview. Vertebral Body Replacement System

S U R G I C A L T E C H N I Q U E David A. McQueen, MD Return to Menu

LCP Medial Proximal Tibial Plate 4.5/5.0. Part of the Synthes LCP periarticular plating system.

Knee Surgical Technique

Surgical Technique. Cannulated Angled Blade Plate 3.5 and 4.5, 90

Conventus CAGE PH Surgical Techniques

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system.

Pre-Operative Planning. Positioning of the Patient

Distal Cut First Femoral Preparation

Large External Fixator Modular Knee Bridge. Using multi-pin clamps.

Surgical Technique. Proximal Humerus Locking Plate

Types of Plates 1. New Dynamic Compression Plate: Diaphyseal fracture: Radius, Ulna, Humerus, Rarely tibia

Periarticular Aiming Arm Instruments for LCP Proximal Tibial Plate 4.5/5.0. Part of the LCP Periarticular Aiming Arm Instrument System (large).

Surgical Technique International Version

Zimmer MIS Periarticular 3.5mm Proximal Tibial Locking Plate

LISS DF and LISS PLT. Less Invasive Stabilization Systems for Distal Femur and Proximal Lateral Tibia.

FLT105 12/02.

Medium External Fixator Humeral Shaft Frame. Modular frame for upper extremity use.

A locking plate system that expands a surgeon s options in trauma surgery. Zimmer NCB Plating System

Instructions For Use. Surgical Technique

Extron External Fixator

Femur. Monoaxial Locking Plate System. Operative Technique. Distal Lateral Femur Universal Holes Targeting Instrumentation.

PROXIMAL TIBIAL PLATE

Surgical Technique. Distal Humerus Locking Plate

VariAx Compression Plating System. Operative technique

Zimmer Small Fragment Universal Locking System. Surgical Technique

Medical Devices DYNAMIC MULTIAXIAL FIXATOR

LCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability.

LCP Superior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

Small Fragment Plating System

Mandible External Fixator II. Provides treatment for fractures of the maxillofacial area.

LCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability.

VA-LCP Anterior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

3.5 mm Locking Attachment Plate

AcUMEDr. Anatomic Midshaft Forearm Plates

AxSOS. Locking Plate System. Operative Technique. Small Fragment Basic Fragment

Transcription:

onotube EXTERN AL FIXATION SYSTEM

onotube

Overview The Monotube Triax external fixation system was developed in cooperation with Prof. J. Lazo-Zbikowski and Prof. J. Cañadell. Its design consists of a dynamic axial fixator designed to maintain rotational and angular stability while allowing the bone to share the load in the axial plane. The Monotube Triax has been designed to handle a wide variety of orthopaedic and trauma applications keeping in mind the need for controlled dynamisation. The built in dynamisation collar allows 0-1mm axial compression thus allowing the surgeon to initiate the natural callus formation that is critical to the healing process. Its absolute modularity and unrestricted reposition possibilities allow restoration of the correct anatomy in three planes. The system consists of three basic components. The dynamic tube, the pin clamp, and the single pin clamp. Speciality clamps and accessories are also available.

The Monotube Triax system can be dynamically loaded upon muscular contraction and weightbearing. This allows the system to be converted from a static to a dynamic mode by activating the built in dynamisation collar. This will stimulate and enhance callus formation and promote faster healing. 1 The Monotube Triax is minimally invasive using only percutaneous Apex Pins which are non conical and therefore avoid radial stresses at the bone to pin interface and reduce soft tissue disruption. The Monotube Triax simple design characteristics make its use extremely versatile and easy to apply thanks to universal instrumentation and few basic components. The Monotube Triax is simple to use, by sliding the desired clamps anywhere along the tube. Fine tuning the reduction is simple, and requires no additional components. The Monotube Triax system is available in three sizes allowing the surgeon to choose the appropriate fixator according to patient size and indication requirements. All the adjustments on the tube and clamp use 7mm square head screws in the red and blue and 5mm square head screws in the yellow and require only one instrument. The Monotube Triax is functional, allowing patients partial weightbearing from the beginning of the treatment.

onotube The Monotube Triax allows increased fracture visualisation through the design of the pin clamps, which permit X-ray visualisation in both antero-posterior and medio-lateral planes, unlike other competitive systems which are restricted to one visual plane. The Monotube Triax system provides the ability to reduce fractures with reduction handles. Post-operative correction and handling are simple. The Monotube Triax has a built in fracture compressiondistraction system. Monotube Triax The Monotube Triax has variable pin positioning allowing for multiple pin placement and good bone purchase. The Monotube Triax system is compatible with other Stryker Howmedica Fixators. The Monotube Triax system is colour coded for easy intra-operative management. Triax Clamps The Monotube Triax is made of lightweight anodised aluminium. Triax Single Pin Clamp Triax Carbon Monotube 3

onotube Controlled Dynamisation Bio-Spring adjustment screw Dynamisation collar The objective of external fixation is to bring stability to a long bone that has sustained a fracture. This process must be as physiological as possible and therefore, the fixation device used must be stable enough to prevent reduction loss and resist movement in lateral bending and torque, yet be dynamic enough to allow minute and controlled amounts of movement at the fracture site during weight bearing. Dynamisation is the term given to the transmission of forces across the fracture (without the frame causing distraction of the fragments), and with the aim of promoting healing. Healing of the bone fractures using external fixation takes place by indirect consolidation, and fractures treated by micromovement heal more quickly than those treated using a rigid external fixator (13 weeks as compared to 18). 1 The precise amount of weight bearing is dependant on the type of fracture, soft tissue damage, total weight of the patient, presence of multiple trauma, pain threshold and the patient's overall condition. Dynamisation should occur at the first sign of periosteal callus formation and the fixator should be set for 1mm of micromovement at the fracture site (see protocol on page 6). The Monotube Triax is designed to provide a high degree of stability, yet permit dynamic movement due to its built in dynamisation module. The Monotube Triax can easily be converted from static to dynamic mode by activating the dynamisation module. The biology of the fracture can be modified by adjusting the external fixator. Rigid external fixators produce primary bone healing, whereas elastic fixators produce a greater volume of periosteal callus. 2 4

Biocompression The Monotube Triax system is designed to permit two types of dynamisation, Biocompression and Adjustable Bio-Spring. The first is an axial telescopic function in which an outer tube slides over an inner tube, allowing a recommended 1mm micromovement at the fracture site. Biocompression allows the surgeon to dial in the amount of compression at the fracture site by simply opening the dynamisation collar from 0 1mm from the beginning. This micromotion is controlled by a specially designed needle-bearing technology that allows the tube to slide effortlessly even if not axially aligned. Other systems have a tendency to jam in this situation. This specialised technology guarantees appropriate dynamisation and therefore, callus formation leading to faster healing. Biocompression is recommended for stable fractures or in fractures where there is substantial cortical contact. Rigid Fixation Force After Callus Biocompression Force Force After Callus Gap 1mm Gap 1mm Immediate transmission of the forces through the fracture

Dynamic Monotube BIO-SPRING ADJUSTMENT SCREW "O"-RING DYNAMISATION COLLAR LENGTHENING SEGMENT DYNAMISATION SEGMENT "O"-RING COMPRESSION/DISTRACTION ADJUSTMENT SCREW

Adjustable Bio-Spring onotube The second type of dynamisation is referred to as ADJUSTABLE BIO-SPRING, and is the combination of an axial telescopic function and a compressive spring. The objective of this shock absorbing mechanism is to counteract muscle tension and prevent the collapse of the fragments in an unstable fracture or a leg lengthening procedure, yet at the same time to guarantee accurate and effective dynamisation. The Adjustable Bio-Spring allows the surgeon to dial in the amount of compression at the fracture site by simply opening the dynamisation collar from 0 1mm, and set the compressive spring to full tension, based on the fracture type and the patients weight. Adjustable Bio-Spring is recommended in unstable fractures or fractures in which there is no cortical contact and leg lengthening procedures. Adjustable Bio-spring Force applied to bone 0 Kg 15 Kg 30 Kg 75 Kg Needle Bearings Adjustable Bio-spring Gap 1mm 30 Kg Spring Tension Gap 2mm Gap 0.5mm Gap 1mm Gap 0mm 30 Kg 30 Kg 30 Kg 30Kg 45Kg Gap 0mm Dynamisation Collar 5

onotube Dynamisation Protocol Stable Fracture patterns Biocompression is recommended for stable fracture patterns. The frame may be dynamised anytime after application. The following steps should be followed: 1. Open the dynamisation collar to 1mm (one complete revolution of the dynamisation collar equates to 1mm). Use the dynamisation wrench if necessary. Note: The one millimetre setting on the collar may or may not be visible. Unstable Fracture patterns Adjustable Bio-Spring is recommended for unstable fracture patterns and leg lengthening. The frame may be dynamised once callus is evident on the X-ray, approximately 21 to 28 days postoperatively. To dynamise the frame, the following sequence should be followed: 1. Advance Adjustable Bio-Spring tension screw clockwise until fully compressed, about 7 1 /2 full turns. The screw will recede into the tube as it compresses the spring. 2. Open the dynamisation collar to one millimetre. Use the dynamisation wrench if necessary. 3. Reduce Bio-Spring tension one full turn anti-clockwise each week. Be sure to check that biocompression collar is still set at 1mm after each spring adjustment. The force required to dynamise the frame will be progressively reduced (see technique guide). Note: X-ray visualisation is required to determine callus formation. Monotube Lengths and Pin Options Tube Colour (Dynamic) Dynamic Monotube Pin Size dia Spring Tension Yellow dia 15mm x 180mm Fully Closed dia 15mm x 250mm Fully Opened 3mm & 4mm 20kg Blue dia 20mm x 250mm Fully Closed dia 20mm x 350mm Fully Opened 4mm & 5mm 30kg Red dia 25mm x 320mm Fully Closed dia 25mm x 470mm Fully Opened 5mm & 6mm 45kg 6

Distraction/Compression onotube The Monotube Triax has a built in compression distraction mechanism, which can be used in lengthening procedures and to adjust fracture gaps. Compression and Distraction are achieved by turning the Lengthening Screw turning the 7mm squared headed screw anti-clockwise will lengthen the tube and distract the fracture. Turning clockwise will shorten the tube and compress the fracture. The end of the tube is marked with a visual reference each 1 /4 turn 4 dots 3 dots 2 dots 1 dot The Monotube Triax system is available in three sizes which are colour coded Yellow, Blue, Red. To determine the proper frame components the size of tube selected is determined by: Location / type of fracture Patient s weight Length of tube required Dynamisation requirements Selecting Proper Dynamic Monotube Size (Yellow, Blue, or Red) Tibia Femur Humerus Forearm Ulna Radius Colles Simple/ stable Oblique/ comminuted/ unstable Simple/ stable Oblique/ comminuted/ unstable Simple/ stable Oblique/ comminuted/ unstable Patient s Weight in Kg (1kg=2.2lb) 10 20 30 40 50 60 70 80 90 100 Y Y Y Y Y Y Y B B Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y B B B B B B Y Y B B B B B B B Y B B B R R R R R Y B B R R R R R R Y Y B B B B B B R Y B B B B R R R R Y=Yellow tube and clamps B=Blue tube and clamps R=Red tube and clamps 7

onotube Triax Standard Pin Clamps The Monotube Triax Pin Clamp allows independent control of the fracture reduction in three planes. Clamps may be placed anywhere along the length of the tube at virtually any angle, wherever the best bone purchase may be available. A unique compression sleeve allows for excellent mobility in rotation preventing deviation of the pin clamp while guaranteeing maximum stability. The two outer square head screws A when tightened hold the pins in the clamp. Each screw can independently lock up to two pins in place. The red and blue Triax Clamps have four pin positions, and the yellow Triax Clamp has two pin positions. The centre square head screw B allows for +/- 20 degrees of angulation in the sagittal plane. The side square head screw C allows for 360 of rotation in the coronal plane. A B A The square head screw D at the bottom of the clamp allows for translation along the length of the tube and for 360 rotation around the axis of the tube. Note: All square head screws need to be tightened to the appropriate torque to maintain adequate stability using the torque wrench (picture of use). Yellow 5Nm C Blue Red 9Nm 11Nm D 8

Triax T-Clamp onotube T-clamps are beneficial when treating proximal and distal fractures or fractures that span a joint. The T-clamp allows for perpendicular placement of pins. Standard Monotube Triax Clamps can be converted to T-clamps utilising the T-adapter. Be sure you select the appropriate adapter for the size of clamp to be modified. Assembly Instructions 1. Select the appropriate T-adapter. 2. Remove body screw and compression sleeve from T-adapter. 3. Remove body screw and compression sleeve from Standard Pin Clamp. Separate pin connector from tube coupling. 4. Insert T-adapter into tube coupling and replace compression sleeve. Body screws C should be introduced through the recessed portion of clamp until fully seated and finger tight. 5. Insert pin connector onto T-adapter and replace compression sleeves. Body screw C should be introduced through recessed portion of the clamp until fully seated and finger tight. A B A C C C D NOTE: Body screws and compression sleeves are exactly alike and will fit in either position. However, if body screws are not started from recessed side of the clamp, they will not fully seat. In addition, the T-adapter should always be connected to the tube coupling before the pin connector. 9

onotube Triax Single Pin Clamp The Monotube Triax Single Pin Clamps are designed for independent pin placement. They allow for capture and stabilisation of fracture fragments. They are also intended for use in pathologies that require non parallel pin position for additional stability of the frame. The Single Pin Clamp features a snap-fit fixation mechanism which ensures an easy and firm grip to the fixation pins. A serrated interlocking mechanism between the jaws of the Pin Clamp provides superior rotational locking. A 7mm square head screw allows easy access. Pins can be placed parallel or convergent to improve stability. The Monotube Triax Single Pin Clamps come in three sizes and accept the following Apex pins Yellow 3/4mm dia. Blue 4/5mm dia. Red 5/6mm dia. Top locking for adjustable control of the pin placement. The Single Pin Clamp allows 360 of rotation in the coronal plane. The square head screw positioned at the bottom of the pin clamp allows for translation along the length of the tube and 360 around the axis of the tube. Triax Tube-to-Tube The Monotube Triax tube-to-tube Clamps allow connection of Red, Blue, and Yellow tubes in various combinations to treat complex trauma or pelvic fractures. Monotube Triax clamps are available in the following configurations Red/Red Red/Blue Blue/Blue Blue/Yellow Yellow/Yellow 10

Triax Hybrid Frame onotube The Monotube Triax can be connected to the TenXor carbon ring by using a ring-to-tube clamp. Such a Triax Hybrid Frame was designed to address C type fracture of the proximal and distal tibia using K-wires. It combines the principles of the circular ring and unilateral frame fixation to better neutralise the forces acting upon the fracture. The TenXor carbon ring is available in various sizes and the ring-totube clamp is available in 2 sizes for blue and red Monotube Triax. Its main features are: Possibility of sliding along the ring in order to determine the best position according to frame configuration Integrated snap-fit mechanism for "clicking" the clamp on the ring Positioning the clamp inside or outside the ring 3 axes of rotation 7mm square head locking screws compatible with Hoffmann II and blue/red Monotube Triax wrenches Easy access of locking screws Manufactured from stainless steel and aluminium Additional information is available in the TenXor brochure and operative technique. Triax Tube-to-Tube The clamp consists of two aluminium jaws that hold the tubes and allow 360 of rotation. A single 7mm square head screw positioned at the top of the clamp enables the device to be locked. There are 100 radially serrated teeth between the jaws which allow precise positioning of the tube components, each tooth movement represents 3.6 of rotation. NOTE: This device cannot be dismantled 11

onotube Humeral Proximal Humerus Wrist Diaphyseal Humerus Distal Humerus Knee Joint Humeral Lengthening Radial Shaft Bridging Floating Knee Knee Arthrodesis Femur Proximal Femur Femoral Shaft Segmental Femur Femoral Lengthening 12

Tibial onotube Proximal Tibia* Tibial Plateau Diaphyseal Tibia* * * Segmental Tibia Hybrid Distal Tibia Ankle Tibial Bone Transport Tibia Lengthening Pelvis Proximal Tibia Ankle Fracture Pelvic Fracture See page 7 for colour classification. *May also be placed antero-medial 13

onotube X-rays Pre-Op Intra-Operative Post-Op Humeral Pre-Op Intra-Operative Post-Op Femur 14 Pre-Op Intra-Operative Post-Op Femur

X-rays onotube Pre-Op Tibial Intra-Operative Post-Op Intra-Operative Tibial Post-Op Pre-Op Intra-Operative Tibial Pre-Op Wrist Intra-Operative Intra-Operative Post-Op Ankle 15

onotube Triax Carbon Tubes If no dynamisation is required or a radiotranslucent frame is needed, Triax Carbon Tubes can be used in place of the Dynamic Tube. Triax Carbon Tubes are available in 3 diameters; Yellow 15, Blue 20, Red 25 and in lengths from 150 400mm The use of Triax Carbon Tubes does not alter the surgical protocol, except that the colour coded end caps must be removed before placement of the Monotube Triax Clamps. Unlike the Dynamic Monotube Triax the Triax Carbon Tubes require an external compression/distraction device. To use the device, position the chariot over the back of the standard Triax pin clamp, and wrap the swivel clamp around the tube. Tighten the 7mm square head screw A, then proceed to loosen pin clamp square head screw D. Compression or distraction can now be achieved. Maximum distraction/compression is:- Yellow 20mm Blue 30mm Red 30mm 1 revolution of square head screw B provides 1mm of compression or distraction. After distraction or compression is completed, re-tighten pin clamp square head screw D. The external compression distraction device may now be moved. Chariot A Wrench D Clamp Screw B Thumbwheel 16

Economical & Radiolucent onotube An uncompromising alternative. When fracture dynamisation is not necessary or radiolucency is desired, the Carbon Monotube Triax offers an efficient and economic solution. Carbon Monotube Triax is available in three colour-coded diameters and a variety of lengths. The Monotube Triax Clamps can be placed anywhere along the tube to achieve the desired pin positioning while making final reduction possible after the frame is attached to the pins! If needed, Single Pin Clamps, T adapter, and tube-to-tube clamps, can be used with Triax Carbon Tubes. 17

2 Products Catalogue Number Description 5150-0-065 Dynamic Tube Assembly Yellow (15mm) 5150-0-070 Dynamic Tube Assembly Blue (20mm) 5150-0-075 Dynamic Tube Assembly Red (25mm) 5150-0-465 Dynamic Tube Yellow (15mm) 5150-0-470 Dynamic Tube Blue (20mm) 5150-0-475 Dynamic Tube Red (25mm) 5150-3-065 Pin Clamp Yellow (15mm) 5150-3-070 Pin Clamp Blue (20mm) 5150-3-075 Pin Clamp Red (25mm) 5150-3-165 Single Pin Clamp Yellow (15mm) 5150-3-170 Single Pin Clamp Blue (20mm) 5150-3-175 Single Pin Clamp Red (25mm) 5150-4-065 T-Adapter Yellow (15mm) 5150-4-070 T Adapter Blue (20mm) 5150-4-075 T-Adapter Red (25mm) 5150-3-415 Tube-to-Tube Clamp Yellow (15mm) 5150-3-420 Tube-to-Tube Clamp Blue/Blue (20mm) 5150-3-425 Tube-to-Tube Clamp Red/Red (25mm) 5150-3-435 Tube-to-Tube Clamp Yellow (15mm)/Blue (20mm) 5150-3-445 Tube-to-Tube Clamp Blue (20mm)/Red (25mm) Please refer to the Tenxor brochure (Cat. Number 5075-3-000) for the components of the Triax Hybrid Frame 18

Products onotube Catalogue Number Description 5150-1-115 Carbon Tube Assembly Yellow Ø15/150mm 5150-1-120 Carbon Tube Assembly Yellow Ø15/200mm 5150-1-125 Carbon Tube Assembly Yellow Ø15/250mm 5150-1-130 Carbon Tube Assembly Yellow Ø15/300mm 5150-2-371 Carbon Tube Yellow Ø15/150mm 5150-2-381 Carbon Tube Yellow Ø15/200mm 5150-2-391 Carbon Tube Yellow Ø15/250mm 5150-2-396 Carbon Tube Yellow Ø15/300mm 5150-2-431 Carbon Tube Blue Ø20/200mm 5150-2-421 Carbon Tube Blue Ø20/250mm 5150-2-411 Carbon Tube Blue Ø20/300mm 5150-2-401 Carbon Tube Blue Ø20/350mm 5150-2-451 Carbon Tube Red Ø25/250mm 5150-2-461 Carbon Tube Red Ø25/300mm 5150-2-471 Carbon Tube Red Ø25/350mm 5150-2-481 Carbon Tube Red Ø25/400mm Instruments 5150-9-265 Long Handle Wrench Yellow 5150-9-270 Long Handle Wrench Blue 5150-9-275 Long Handle Wrench Red 5150-9-585 Reduction Handles Blue/Red Clamps 5054-8-009 Spanner Wrench 5150-9-465 Compression Distraction Device Yellow (15mm) 5150-9-470 Compression Distraction Device Blue (20mm) 5150-9-475 Compression Distraction Device Red (25mm) 5150-9-115 Dynamisation Wrench Yellow 5150-9-120 Dynamisation Wrench Blue 5150-9-125 Dynamisation Wrench Red 5150-9-916 Monotube Triax Yellow case 5150-9-946 Monotube Triax Red/Blue Case Stryker, Hoffmann, Hoffmann II, Apex, Monotube, Triax, Compact and Tenxor are trademarks of Stryker Corporation. Hoffmann II Swiss Patent Application: 01-709/94-3. Other Patents Pending. * Patents: EU 385,929; 374,093; Canada 1,193,506; U.S. 5,160,335 and 5,207,676. ** Swiss Patent Application: 02-709/94-3. Other Patents Pending. *** Patents: EU 230,856; Swiss CH 671,150; U.S. 4,978,350. Data on file at Stryker Howmedica Osteonics USA. 19

E X T E R N A L F I X A T I O N S Y S T E M Unilateral frame system designed to handle a wide variety of fractures and limb-lengthening applications. This simple, colour-coded system offers both dynamic and carbon tubes for individualised performance and economy. True simplicity, versatility, and economy. Modular frames which allow for true independent pin placement. Completely compatible with Original Hoffmann components, this new system improves flexibility and ease-of-use, while enhancing frame economics through minimal componentry. It s external fixation with a snap. ** Designed to complement the anatomy of the distal radius by allowing independent movement of its clamps in multiple planes. Standard unilateral or bi-lateral bridging frames for intra-articular fractures and peri-articular non-bridging frames for extraarticular fractures. Fully compatible with the Hoffmann II System, based on a spring-loaded snap-fit mechanism that improves flexibility and ease-of-use. * The DJD II is a Dynamic Elbow Joint Distractor. Fully compatible with the Hoffmann II Compact System, it is designed to treat posttraumatic elbow stiffness as well as acute elbow trauma cases. The Tenxor System is a hybrid system providing advanced technology and ease of application. Fully compatible with Hoffmann II and Monotube Triax, based on a spring-loaded, snap-fit mechanism that improves flexibility and ease of use. *** Every Fixator incorporates the high quality pin-to-bone interface provided by Apex Pins. The Apex Pin cuts more sharply with less torque, friction and heat upon insertion improving purchase while minimising the risk of pin tract problems. Available in self-drilling and blunt tip designs, only from Stryker Howmedica Osteonics! MANUFACTURER: Manufacturing location 5 chemin des Aulx CH-1228 Plan-les-Ouates Geneva, Switzerland Tel: 00 41 22 884 0111 Fax:00 41 22 884 0199 Cat No: 5075-2-500 2000 Stryker Corporation. All rights reserved.