Acute dissections of the descending thoracic aorta (Debakey

Similar documents
Malperfusion Syndromes Type B Aortic Dissection with Malperfusion

Management of Acute Aortic Syndromes. M. Grabenwoger, MD Dept. of Cardiovascular Surgery Hospital Hietzing, Vienna, Austria

Challenges. 1. Sizing. 2. Proximal landing zone 3. Distal landing zone 4. Access vessels 5. Spinal cord ischemia 6. Endoleak

Indications for use. Contraindications within the United States

The Petticoat Technique Managing Type B Dissection with both Early and Long Term Considerations

Thoracic Endovascular Aortic Repair (TEVAR) Indications and Basic Procedure

Introducing the GORE TAG Conformable Thoracic Stent Graft with ACTIVE CONTROL System

Endovascular Management of Thoracic Aortic Pathology Stéphan Haulon, J Sobocinski, B Maurel, T Martin-Gonzalez, R Spear, A Hertault, R Azzaoui

Open fenestration for complicated acute aortic B dissection

TEVAR for complicated acute type B dissection with malperfusion

Aggressive Resection/Reconstruction of the Aortic Arch in Type A Dissection

AORTIC DISSECTIONS Current Management. TOMAS D. MARTIN, MD, LAT Professor, TCV Surgery Director UF Health Aortic Disease Center University of Florida

RadRx Your Prescription for Accurate Coding & Reimbursement Copyright All Rights Reserved.

I-Hui Wu, M.D. Ph.D. Clinical Assistant Professor Cardiovascular Surgical Department National Taiwan University Hospital

Combined Endovascular and Surgical Repair of Thoracoabdominal Aortic Pathology: Hybrid TEVAR

UC SF Early Intervention in Type B Dissection: Results From the INSTEAD XL Trial. Acute Type B Dissection. Outline. Disclosures.

EVAR and TEVAR: Extending Their Use for Rupture and Traumatic Injury. Conflict of Interest. Hypotensive shock 5/5/2014. none

Percutaneous Approaches to Aortic Disease in 2018

Treatment of acute type B aortic dissection: Current status

Abdominal and thoracic aneurysm repair

Type II arch hybrid debranching procedure

Global Evidence for the Treatment of Type B Aortic Dissection

Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully

UC SF An Algorithm to Choose Which Uncomplicated (Asymptomatic) Acute Type B Dissection Patients Should Undergo TEVAR. Disclosures.

History of the Powerlink System Design and Clinical Results. Edward B. Diethrich Arizona Heart Hospital Phoenix, AZ

FLEXIBLE, BALOON EXPANDABLE

UC SF. Disclosures. Thoracic Endovascular Aortic Repair 4/24/2009. Management of Acute Dissections: Is There Still a Role for Open Surgery?

Modified candy-plug technique for chronic type B aortic dissection with aneurysmal dilatation: a case report

Anatomy and Classification of Aortic Dissection

Aortic Center of Excellence at Sentara

CT angiography in type I acute aortic dissection complicated with malperfusion - a visual review of obstruciton patterns

Residual Dissection and False Lumen Aneurysm After TEVAR

Endovascular therapy for Ischemic versus Nonischemic complicated acute type B aortic dissection (catbad).

TEVAR for Chronic dissections: indications for TEVAR, long term results

Optimal repair of acute aortic dissection

Antegrade Thoracic Stent Grafting during Repair of Acute Debakey I Dissection: Promotes Distal Aortic Remodeling and Reduces Late Open Re-operation

TEVAR. (Thoracic Endovascular Aortic Repair) for Aneurysm and Dissection. Bruce Tjaden MD Vascular Surgery Fellow

Indications for stent grafts in type B aortic dissection

Zenith Renu AAA Converter Graft. Device Description Planning and Sizing Deployment Sequence Patient Follow-Up

Understanding the Predictors of Aneurysmal Degeneration in Type B Dissection

STS/EACTS LatAm CV Conference 2017

Aortic stents, types, selection, tricks in deployment.

In recent years, the field of endovascular surgery has revolutionized

The use of thoracic endovascular

Performance of the conformable GORE TAG device in Type B aortic dissection from the GORE GREAT real world registry

Acute Type B dissection. Closure of the infra diaphragmatic tear: how and when?

Development of a Branched LSA Endograft & Ascending Aorta Endograft

Intravascular Ultrasound in the Treatment of Complex Aortic Pathologies. Naixin Kang, M.D. Vascular Surgery Fellow April 26 th, 2018

Distal False Lumen Occlusion in Aortic Dissection With a Homemade Extra-Large Vascular Plug: The Candy-Plug Technique

Do the Data Support Endovascular Therapy for Descending Thoracic AD? Woong Chol Kang, M.D.

Subject: Endovascular Stent Grafts for Disorders of the Thoracic Aorta

Early outcomes of acute retrograde dissection in the aortic arch and the ascending aorta data from IRAD

Ascending Aorta: Is The Endovascular Approach Realistic?

Ancillary Components with Z-Trak Introduction System

I SECTION I. Thoracic aortic aneurysms

Evaluation of Dynamic Intimal Flap Movement in Acute Stanford Type B Aortic Dissections (ATBD) and the Effects of Thoracic Endovascular Stent Grafting

The catheter-based treatment of valvular disease and aortic

P Paraplegia abdominal aortic aneurysm repair, 52 paraparesis, 52 pathophysiology, 51 rates and endografts, 51 two-stage approach, 129

Total endovascular techniques utilization in aortic dissection radical treatment

Primary to non-coronary IVUS

Reimbursement Guide Zenith Fenestrated AAA Endovascular Graft

Optimal Treatment of Chronic Dissection

Dissection de type B: l étude Instead et corollaire stratégique

Emerging Roles for Distal Aortic Interventions in Type A Dissection Surgery

THE THE MORE MORE NATURAL APPROACH TO OPTIMAL FIT

Robert F. Cuff, MD FACS SHMG Vascular Surgery

Quick Reference Guide

Chungbuk Regional Cardiovascular Center, Division of Cardiology, Departments of Internal Medicine, Chungbuk National University Hospital Sangmin Kim

An Overview of Post-EVAR Endoleaks: Imaging Findings and Management. Ravi Shergill BSc Sean A. Kennedy MD Mark O. Baerlocher MD FRCPC

COMPLICATIONS OF TEVAR

Neurological Complications of TEVAR. Frank J Criado, MD. Union Memorial-MedStar Health Baltimore, MD USA

Follow-up of Aortic Dissection: How, How Often, Which Consequences Euro Echo 2011

Transcarotid Artery Endovascular Reconstruction of the Aortic Arch by Modified Bifurcated Stent Graft for Stanford Type A Dissection

Is there a way to predict the risk in uncomplicated Type B aortic dissections? FRANS MOLL University Medical Centre Utrecht - Netherlands

How to achieve a successful proximal sealing in TEVAR? Pr L Canaud

Santi Trimarchi, MD, PhD Vascular Surgeon Thoracic Aortic Research Center, Director IRCCS Policlinico San Donato University of Milan

Title. Different arch branched devices are available, is morphology the. main criteria of choice? Ciro Ferrer, MD

Aortic Arch pathology options: Open,Hybrid, fenestration, Chimney or branched stent-graft?

Cook Medical. Zenith Flex AAA Endovascular Graft with Z-Trak Introduction System Physician Training

Abdominal Aortic Aneurysm 가천대길병원 이상준

Technique and Outcome of Laser Fenestration For Arch Vessels

Modification in aortic arch replacement surgery

Percutaneous Axillary Artery Access For Branch Grafting for complex TAAAs and pararenal AAAs: How to do it safely

2018 CPT CODING CHANGES

Coding Changes for 2018

Treatment of Thoracoabdominal Aneurysms Is there a need for custom-made devices?

Are stent-grafts for acute type B dissection durable? Est-ce que les stents graft pour la dissection aigue de type B sont efficaces à moyen terme?

Development of Stent Graft. Kato et al. Development of an expandable intra-aortic prothesis for experimental aortic dissection.

Challenges with Complex Anatomies Advancing Care in Endovascular Aortic Treatment

Optimizing Accuracy of Aortic Stent Grafts in Short Necks

ADSORB trial results: Is it enough to switch the paradigm?

Description. Section: Surgery Effective Date: April 15, Subsection: Surgery Original Policy Date: December 6, 2012 Subject:

The role of false lumen intervention to promote remodelling via induced thrombosis the FLIRT concept

Challenging of contrast agent-free endovascular treatment using 3D imaging

Fate of Aneurysms of the Distal Arch and Proximal Descending Thoracic Aorta After Transaortic Endovascular Stent-Grafting

Treatment of complex thoracic cases Focus on the new Gore Active Control TAG device

Vascular Intervention

AORTIC DISSECTION. DISSECTING ANEURYSMS OF THE AORTA or CLASSIFICATION

My personal experience with INCRAFT in standard and challenging cases

OPEN AND ENDOVASCULAR TECHNIQUES IN THE CARDIOTHORACIC SURGEON S HANDS

Transcription:

Endovascular Treatment of Acute Descending Thoracic Aortic Dissections Nimesh D. Desai, MD, PhD, and Joseph E. Bavaria, MD Acute dissections of the descending thoracic aorta (Debakey type III or Stanford type B) are predominantly managed with antihypertensive medical therapy, which has been demonstrated to have less than 10% mortality in uncomplicated patients. 1 In patients with type B aortic dissection complicated by limb or visceral malperfusion, refractory hypertension or pain, or rupture or impending rupture, open operative therapy via thoracotomy approach to seal the entry tear and fenestrate the dissection flap or bypass malperfused vessels has been associated with poor outcomes. Presentation with malperfusion is a surgical emergency that is associated with high mortality ( 30%) without prompt surgical intervention. Recent innovations in the development of thoracic endovascular repair (TEVAR) have enabled surgeons to treat complicated type B dissections less invasively with improved Division of Cardiovascular Surgery, Department of Surgery, University of Pennsylvania School of Medicine, Philadelphia, Pennsylvania. Address reprint requests to Nimesh D. Desai, MD, PhD, Division of Cardiovascular Surgery, Department of Surgery, University of Pennsylvania School of Medicine, 6th Floor, Silverstein Pavilion, 3400 Spruce Street, Philadelphia, PA 19104. E-mail: Nimesh.Desai@uphs.upenn.edu results. Results of endovascular treatment of malperfusion with thoracic aortic stent-grafts have been highly favorable compared with open surgery and endovascular repair is now the treatment of choice for these extremely high-risk and complex patients. TEVAR, in combination with other endovascular interventions, can successfully seal the entry tear, thrombose the thoracic portion of the false lumen, and relieve malperfusion syndromes. 2 Longer term follow-up has shown favorable remodeling of the aorta in type B dissection patients treated with TEVAR, which has prompted interest in using TEVAR for treatment of uncomplicated cases to prevent the 5 to 15 mm/yr aortic dilation growth rate observed in medically treated cases. 3 Nearly half of patients with type B dissection will experience significant aortic growth requiring surgical intervention or an aortic complication in follow-up. Since the initial descriptions of TEVAR for type B aortic dissections, devices have become more flexible, less prone to mechanical failure, and available in a wider variety of diameters. In this report, a case of acute type B aortic dissection complicated by limb malperfusion is used to illustrate a variety of approaches used to treat this condition. 150 1522-2942/09/$-see front matter 2009 Elsevier Inc. All rights reserved. doi:10.1053/j.optechstcvs.2009.06.006

Acute descending thoracic aortic dissections 151 Operative Technique Figure 1 The hybrid operating room: successful endovascular repair of complex aortic pathologic treatment begins with a team of cardiac and vascular surgeons, cardiovascular anesthesiologists, neurology, and nursing in an appropriately equipped hybrid operating room. The ideal hybrid operating room is designed with a fixed high-quality ceiling- or floor-mounted image intensifier, adequate space to accommodate transesophageal echocardiography (TEE) equipment, intravascular ultrasound (IVUS), neuromonitoring equipment, and a cardiopulmonary bypass pump if necessary, and multiple movable viewing screens that can display angiography, hemodynamics, TEE, and IVUS simultaneously.

152 N.D. Desai and J.E. Bavaria Figure 2 Acute type B dissection with limb malperfusion: a patient presented with acute Stanford type B aortic dissection starting distal to the origin of the left subclavian artery and extending to below the iliac bifurcation. The entry tear is seen in the typical position in the greater curve of the distal arch/proximal descending thoracic aorta. (A) The visceral segment arises from the true lumen, which is significantly compressed in the lower thoracic aorta. (B) The right iliac artery is fully occluded by the dissection flap, causing malperfusion of right lower extremity. (C) The goal of therapy is to cover the entry tear site, re-expand the true lumen, and relieve the malperfusion. a. artery.

Acute descending thoracic aortic dissections 153 Figure 2 (Continued)

154 N.D. Desai and J.E. Bavaria Figure 3 Arterial access: access to the pulseless right common femoral artery is performed via surgical cut-down (A). Depending on size, the artery may be controlled with vessel loops or double purse-string sutures (B). The left common femoral artery is accessed percutaneously using a Seldinger technique. Fluoroscopy is employed to ensure puncture over the femoral head and passage of all wires. a. artery; v. vein.

Acute descending thoracic aortic dissections 155 Figure 4 The artery is accessed with purse-string suture through which a 9-Fr. sheath is inserted over a multipurpose J-wire. (A) A flexible tip Bentson guidewire is passed into the thoracic aorta under fluoroscopic guidance using a guide catheter and an IVUS catheter is passed over the wire to verify that the true lumen has been accessed. (B) In the left femoral artery, a 5-Fr. sheath is placed, through which a marker pigtail catheter is passed over a Bentson wire into the ascending aorta. On the right side, the Bentson wire is exchanged using an exchange catheter for a stiff Lunderquist wire, which will be used for device placement. (C) The 9-Fr. sheath is exchanged for the device sheath through which the stent-graft will be delivered. a. artery; IVUS intravascular ultrasound.

156 N.D. Desai and J.E. Bavaria Figure 5 Initially, a 10- to 15-cm-length thoracic aortic stent-graft is deployed with a 10 to 20% diameter oversize compared with the total diameter of the native aorta. Ideally, the stent-graft is deployed such that there is at least 2 cm of nondissected aorta in the proximal landing zone in a segment without significant caliber change, atheroma, or thrombus. Because the entry tear in most type B dissections occurs along the greater curve of the distal aortic arch just beyond the left subclavian artery takeoff, partial or total subclavian artery coverage is frequently required. In all elective cases, we prophylactically perform left-carotid-left-subclavian artery bypass. In emergency cases, this bypass is performed when there is left arm malperfusion post stent-graft insertion. Excessive oversizing is avoided to prevent infolding or stent collapse. Frequently, the distal aspect of the stent may be partially collapsed and will slowly dilate to its nominal diameter over time. Ballooning is avoided to prevent the dreaded complication of retrograde propagation of the dissection into the ascending aorta, unintended fenestration at the distal end of the stent-graft, or even aortic rupture from excessive radial forces.

Acute descending thoracic aortic dissections 157 Figure 6 After insertion of the first stent-graft, visceral malperfusion worsened as the dynamic dissection flap compressed the origins of the visceral vessels. A second stent-graft was placed with generous overlap to further re-expand the true lumen. (A) This relieved the visceral malperfusion but residual right lower extremity malperfusion remained. This was managed with deployment of a bare metal stent in the infrarenal aorta and bilateral common iliac artery stents. (B) Similar approaches may be employed in other areas of static obstruction (ie, renal arteries) with bare metal stents as needed. a. artery. Conclusions TEVAR is an established treatment for complicated type B aortic dissections. Extension of this modality to the treatment of uncomplicated type B dissections as a method of preventing late dilation of the thoracic aorta is evolving as experience accrues and stent-graft design facilitates their use. Ideal characteristics of a dissection stent-graft include low porosity, self-expansion with conformability and appropriately distributed radial forces, limited exposed bare wire stent without external fixation barbs, a wide variety of diameters, and smaller and highly flexible delivery systems. To diminish the risk of paraplegia, coverage of only a short segment of the thoracic aorta to seal the tear site and re-expand the true lumen is required in most cases. In planned cases of extended thoracic aortic coverage, a spinal drain is placed prophylactically. After the proximal tear site has been effectively excluded, perfusion pressures are kept supra-normal to ensure adequate spinal perfusion in higher risk cases. The techniques presented in this article are most applicable to type B dissections presenting to the operating room within 14 days of presentation (acute). In chronic dissection cases, the management strategy is to exclude the aneurysmal segment with proximal and distal seal similar to aneurysm cases as the membrane between true and false lumens is too robust to allow the graft to compress the false lumen. References 1. Tsai TT, Fattori R, Trimarchi S, et al: Long-term survival in patients presenting with type B acute aortic dissection: Insights from the International Registry of Acute Aortic Dissection. Circulation 114:2226-2231, 2006 2. Szeto WY, McGarvey M, Pochettino A, et al: Results of a new surgical paradigm: Endovascular repair for acute complicated type B aortic dissection. Ann Thorac Surg 86:87-93, 2008 3. Blount KJ, Hagspiel KD: Aortic diameter, true lumen, and false lumen growth rates in chronic type B aortic dissection. AJR Am J Roentgenol 192:W222-W229, 2009