Supported Liquid Extraction (SLE) For Food Applications

Similar documents
Protect Your Mass Spec

APPLICATIONS TN Determination of Sterols in Olive Oil using Supported Liquid Extraction (SLE), Solid Phase Extraction (SPE) and GC-FID

There's a Cleaner Way!

APPLICATIONS TN A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE)

Phospholipid Removal Solutions

Labs Across the World Are Advancing Their Protein Precipitation

Finally, a Solid Phase Extraction product for Drugs of Abuse

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1.

APPLICATIONS TN Determination of Sugars in Animal Feed using HPLC-ELSD

A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns

METHAMPHETAMINE & AMPHETAMINE

APPLICATIONS TN Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology.

Rapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS. JWH018-4-Hydroxypentyl metabolite

PAIN PANEL. Research and Solutions

APPLICATIONS TN Analytical Method

Keep It Clean. Solid Phase Extraction Solutions for Drugs of Abuse Analysis. Neutral Drugs of Abuse Basic Drugs of Abuse

Keep it Clean with Strata -X

Strata-X- NEW! Drug B. Drug B Plus for In-Well Hydrolysis. Simplify Your Solid Phase Extraction.

Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases

SIMPLIFIED CHIRAL SEPARATIONS. Lux Cellulose-1. Guaranteed Alternative. to CHIRALCEL OD-H. Exceptional Quality Sensibly Priced

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

NEW. Kinetex. Biphenyl TMS TMS TMS TMS. Selectivity that a C18 just can t give you!

APPLICATIONS TN Materials and Methods

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1

Core-Shell Technology for Proteins and Peptides

APPLICATIONS Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns

For Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns.

High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS)

Preparative Chromatography Meets UHPLC

Extraction of 11-nor-9-carboxy-tetrahydrocannabinol from Hydrolyzed Urine by ISOLUTE. SLE+ Prior to GC/MS Analysis

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Comprehensive Study of SLE as a Sample. Preparation Tool for Bioanalysis

ZB-FAME The Fast FAME GC Column

PAIN PANEL. Application Guide. Screen 41 compounds in under 4 minutes

Columns The FIRST and ONLY sub-2 µm core-shell columns on the market

APPLICATIONS TN Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex 2.6 µm Core-Shell Technology Column

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit

LC-MS/MS Method for the Determination of Tenofovir from Plasma

APPLICATION TN Materials and Methods Reagents and Chemicals

Measuring Phytosterols in Health Supplements by LC/MS. Marcus Miller and William Schnute Thermo Fisher Scientific, San Jose, CA, USA

Providing a Universal, One-step Alternative to Liquid-Liquid Extraction in Bioanalysis

Extraction of a Comprehensive Steroid Panel from Human Serum Using ISOLUTE. SLE+ Prior to LC/MS-MS Analysis

Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs. Table 1. List of pain panel drugs

A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

Evaluating the Isolation and Quantification of Sterols in Seed Oils by Solid-Phase Extraction and Capillary Gas Liquid Chromatography

Exceed your Purification Goals. Guaranteed. Phenomenex l WEB:

Figure 1. Core-Shell Particle Technology

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis

Confidence. A New Standard of. Calibration, Surrogate, & Internal Standards for Environmental Analysis

Vitamin Testing APPLICATIONS GUIDE

Yes You Can! New! Amazing EVO C18. Core-Shell Technology

Application Note. Author. Abstract. Introduction. Food Safety

IDENTIFICATION AND CONTROLOFRESIDUALSOLVENTS Identification and control of residual solvents EUROPEAN PHARMACOPOEIA 6.

An Easier QuEChERS Solution for Diverse Matrices. Learn more at

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

Analytes. Sample Preparation Procedure. Introduction. Format: Sample Pre-treatment. Sample Loading. Analyte Extraction and Derivatization.

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis

The challenging extraction of non-polar contaminants out of a non-polar vegetable oil sample

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.

High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine

Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs

Extraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis

Core-Shell Technology. 11 HPLC Myths. Uncovered. & Why You Must Have Kinetex Core-Shell HPLC Columns

Simultaneous Determination of Prescription and Designer Benzodiazepines in Urine and Blood by SPE and LC-MS/MS

Extraction of Synthetic and Naturally Occurring Cannabinoids in Urine Using SPE and LC-MS/MS

The Investigation of Factors Contributing to Immunosuppressant Drugs Response Variability in LC-MS/MS Analysis

Step 3: muscle, nasal sprays and drops or used as topical

EASIMIP TM PATULIN Product Code: P250 / P250B

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

METHOD OF ANALYSIS DETERMINATION OF THE COMPOSITION AND CONTENT OF STEROLS AND TRITERPENE DIALCOHOLS BY CAPILLARY COLUMN GAS CHROMATOGRAPHY

Comparison of Biotage Extrahera vs. Manual Sample Processing Using a Vacuum Manifold

TN-0116 Scott Krepich

Sample Preparation Techniques for Biological Matrices: Finding the right balance to achieve optimal results

Awesome! Unconventionally. Kinetex EVO C18 HPLC/UHPLC Core-Shell Columns 2.6. Core-Shell Technology

using the Agilent 7696A Sample Prep

Determination of Pharmaceutical Residues in Bovine Milk via LC MS/MS Following Solid Phase Extraction

Rapid and Direct Analysis of Free Phytosterols by Reversed Phase HPLC with Electrochemical Detection

Quantitative Analysis of THC and Main Metabolites in Whole Blood Using Tandem Mass Spectrometry and Automated Online Sample Preparation

CANNABIS TESTING ACCESSORIES

Protein Precipitation for Biological Fluid Samples Using Agilent Captiva EMR Lipid 96-Well Plates

Determination of Tetracyclines in Chicken by Solid-Phase Extraction and High-Performance Liquid Chromatography

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid

METHOD OF ANALYSIS DETERMINATION OF THE COMPOSITION AND CONTENT OF STEROLS BY CAPILLARY-COLUMN GAS CHROMATOGRAPHY

ApplicationNOTE EXACT MASS MEASUREMENT OF ACTIVE COMPONENTS OF TRADITIONAL HERBAL MEDICINES BY ORTHOGONAL ACCELERATION TIME-OF-FLIGHT.

COMBO ULTIMATE HPLC/UHPLC. Kinetex + Luna Omega NEW. Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput

Nitrogen/Protein Determination in Starch by Flash Combustion using Large Sample Weight as an Alternative to the Kjeldahl Method

Detection of Low Level of Chloramphenicol in Milk and Honey with MIP SPE and LC-MS-MS

LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine

APPLICATION TN Rapid Analysis of a 48 Drug Research Panel in Less Than 4 Minutes Using Kinetex Biphenyl Core-Shell Technology HPLC/UHPLC Columns

Simultaneous Quantitative Analysis of Total Catecholamines and Metanephrines in Urine Using CLEAN UP CCX2 and LC-MS/MS

Determination of Ractopamine and Clenbuterol in Beef Samples

A RAPID AND SENSITIVE ANALYSIS METHOD OF SUDAN RED I, II, III & IV IN TOMATO SAUCE USING ULTRA PERFORMANCE LC MS/MS

Extraction of 25-hydroxy Vitamin D from Serum Using ISOLUTE. PLD+ Prior to LC-MS/MS Analysis

HPLC Analysis with Fluorescence Detection of Chlorophyll Degradation Products Pheophytins and Pyropheophytin in Virgin Olive Oil

Simultaneous Quantitative Analysis of Total Catecholamines and Metanephrines in Urine Using 500 MG CLEAN UP CCX2 and LC-MS/MS

The Development of LC/MS Methods for Determination of MDMA (Ecstasy) and Metabolites in Biological Samples

Rapid and Robust Detection of THC and Its Metabolites in Blood

Transcription:

Supported Liquid Extraction (SLE) For Food Applications Novum Synthetic SLE Unique, Synthetic Sorbent that Provides Consistent, Reliable Results Strata DE Diatomaceous Earth SLE Cost-Effective, Guaranteed Alternative to Traditional Diatomaceous Earth SLE Sorbents www.phenomenex.com/foodsle

Choose the Best SLE Solution for Your Analysis Phenomenex provides two options for your SLE analysis, a unique synthetic sorbent and a traditional diatomaceous earth sorbent, each of which provides its own benefits. Select the best option for your work by using the chart below. simplified liquid extraction Supported Liquid Extraction Synthetic Sorbent Diatomaceous Earth Lot-to-lot consistency and reproducibility Ethyl Acetate, Methyl Tert-Butyl Ether (MTBE) MINI 96-Well Plates, MAX 96-Well Plates Advantages Extraction Solvents Plate Formats Cost effective and large volume capabilities Dichloromethane (DCM), Hexane, MTBE, Ethyl Acetate 200 µl 96-Well Plates, 400 µl 96-Well Plates Tube 1 cc, 3 cc, 6 cc, 12 cc 12 cc and 60 cc Formats Need Help Selecting the Right SLE Option? or Call us Live Chat www.phenomenex.com/livechat 2 Phenomenex l WEB: www.phenomenex.com

Explore Your SLE Options and Applications Novum SLE A Unique, Synthetic Sorbent...p. 5 Strata Diatomaceous Earth (DE) SLE A Cost-Effective Alternative to Traditional SLE Sorbents...p. 5 Applications Acrylamide from Coffee...pp. 6 7 Sterols from Olive Oil...pp. 8 10 Ordering Information...p. 11 Phenomenex l WEB: www.phenomenex.com 3

Unique SLE Sorbents SLE produces more reproducible results, increased accuracy, and higher throughput possibilities than Liquid-Liquid Extraction by utilizing a solid support to mimic LLE. With very little method development, both SLE options remove unwanted matrix interferences to provide cleaner samples than LLE. Two Simple Steps for a Cleaner Extraction: STEP 01 Load your sample in aqueous solvent. No emulsions Interferences ( i.e. phospholipids, proteins, salts, etc.) Target Analytes STEP 02 Collect target analytes in water immiscible solvent for analysis. Save time and solvent usage 4 Phenomenex l WEB: www.phenomenex.com

simplified liquid extraction Supported Liquid Extraction Novum Synthetic SLE As a unique, synthetic SLE sorbent, expect Novum to provide reliable, more consistent lot-to-lot cleanup that excels under extraction conditions where traditional diatomaceous earth SLE falls short, such as ethyl acetate. Recommended Uses: Ethyl acetate extractions Smaller volume samples Low variation lot-to-lot novum simplified liquid extraction Strata DE Diatomaceous Earth SLE Packed with diatomaceous earth, Strata DE is a cost-effective alternative to traditional SLE products such as Biotage ISOLUTE SLE+, Thermo Fisher Hypersep SLE, and Agilent Chem Elut SLE that won t require you to sacrifice your results. Recommended Uses: Direct alternative to traditional diatomaceous earth SLE sorbents Non-oxygenated extraction solvents such as DCM and Hexane Large volume samples, up to 20 ml capacity with 60 cc tubes! Phenomenex l WEB: www.phenomenex.com 5

Acrylamide from Coffee Pre-Treatment Prepare ground coffee as directed on the coffee product using 1,500 ml of boiling water and 60 g of ground coffee. Prepare instant coffee using 250 µl of boiling water and 2 g of instant coffee. Allow both samples to reach room temperature before adding 20 µl Acrylamide-13C3 (4 µg/ml in water) to 800 µl of the prepared coffee. (100 ng/ml for ground coffee and 200 ng/ml for instant coffee). Then add 150µL 2% Ammonium hydroxide in water to the spiked samples and vortex for 30 seconds. SLE Protocol Cartridge: Novum SLE 6 cc Tube Part No.: 8B-S138-JCH Achieve Ultra-Clean Samples with Novum SLE BEFORE AFTER Load: Pre-treated sample and pulse vacuum (~5-10 Hg) for 5-10 seconds or until sample has completely entered the sorbent Wait: 5 minutes Elute: 2x 2.5 ml Ethyl acetate/tetrahydrofuran (1:1) and allow to elute by gravity into a tube containing 10 µl Ethylene glycol* Apply: Vacuum or apply positive pressure at 5 Hg for 20-30 seconds to complete the extraction Dry: Sample under slow stream of Nitrogen at 45 C Reconstitute: 300 µl Water *Ethylene glycol was added to prevent the sample from drying completely during the dry down step. Recovery of Acrylamide Sample ID Ground coffee (100 ng/ml) Instant coffee (200 ng/ml) Mean of area ratio 1.89 3.75 STDV 0.01 0.06 CV (%) 0.78 1.61 Absolute Recovery ( %) 94.9 92.8 n= 6 6 Excellent Recoveries! 6 Phenomenex l WEB: www.phenomenex.com

Acrylamide from Coffee Intensity, cps Acrylamide from Coffee (100ng/mL) 1.3e6 1.2e6 1.1e6 1.0e6 9.0e5 8.0e5 7.0e5 6.0e5 Acrylamide LC-MS/MS Conditions Column: Synergi 4 µm Hydro-RP Dimensions: 50 x 2.0 mm Part No.: 00B-4375-B0 Guard Cartridge: SecurityGuard Hydro-RP Part No.: AJ0-7510 Mobile Phase: A: 0.1 % Formic acid in Water B: 0.1 % Formic acid in Methanol Gradient: Time (min) 0 0.6 0.85 3 3.01 5 B (%) 0 0 100 100 0 0 Flow Rate: 0.3 ml/min Injection Volume: 5 µl Temperature: Ambient Detection: MS/MS (SCIEX API 5000 ), ESI+ 5.0e5 Acrylamide 13 C 3 4.0e5 3.0e5 2.0e5 1.0e5 0 1 2 3 min App ID 22851 Phenomenex l WEB: www.phenomenex.com 7

Sterols from Olive Oil Pre-treatment Add 40 μl of 1 mg/ml cholestanol in chloroform to a clean, dry 20 ml screw-top test tube and evaporate to dryness under a nitrogen flow. Saponification 1. Add 200 mg of olive oil sample to the test tube containing the internal standard. 2. Add 1.5 ml of 2M Potassium hydroxide in 95 % Ethanol. 3. Cap the tube and heat in an 80 C oven for 25 minutes. 4. Mix sample gently to ensure homogeneity (sample should appear as a clear solution) and continue heating for an additional 25 minutes. 5. After heating, add 13.5 ml of deionized water and mix. The entire diluted volume is now ready to load onto the SLE cartridge. SLE Protocol Cartridge: Strata DE SLE cartridge, 20 ml loading capacity, 60 cc Tube Part No.: 8B-S325-VFF Load: Diluted sample (from saponification step 5) plus 2x 1 ml DI water rinse (17 ml total volume, gravity flow) Wait: 15 minutes Extract: 3x 15 ml Diethyl ether (gravity flow) Evaporate: Dry under N 2 at 40 C (greenish-yellow, oily residue) Reconstitute: 5 ml of Hexane SPE (Solid Phase Extraction) Protocol and Derivatization Cartridge: Strata Si-1 (1 g/6 ml) tube Part No.: 8B-S012-JCH Condition: 1. 2x 6 ml Hexane 2. 1 ml 0.2M Potassium hydroxide in 95 % Ethanol Equilibrate: 5 ml Hexane immediately after potassium hydroxide elution Load: Reconstituted SLE extract (5 ml) followed by 2x 1 ml Hexane rinses Wash: 85 ml Hexane/Diethyl ether (98:2) under 3 Hg vacuum, flow rate of 2 ml/min.* Elute: 10 ml Hexane/Diethyl ether (60:40) Dry: Dry under N 2 at 50 C. After evaporating to dryness, add 3-4 drops of acetone and then re-evaporate under N 2 to remove any occluded water. Place in 100 C oven for 10 minutes. Derivatization: 250 µl Pyridine/BSTFA (3:1) at 80 C for 30 minutes *To handle the large volume of eluant, a 60 ml empty reservoir tube was attached to the 6 ml SPE tube. 8 Phenomenex l WEB: www.phenomenex.com

Sterols from Olive Oil Extra Virgin Olive Oil Sterols 70 65 60 55 50 Sample: 1. Cholestanol (internal standard) 2. Campesterol 3. Stigmasterol 4. Clerosterol 5. β-sitosterol 6. Sitostanol 7. Δ-5-Avenasterol 8. Δ-5,24-Stigmastadienol 9. Δ-7-Avenasterol 10. Erythrodiol 5 GC Conditions Column: Zebron ZB-5plus Part No.: 7HG-G032-11 Dimensions: 30 m x 0.25 mm x 0.25 µm Injection: Split 5:1 @ 280 C, 1 µl Recommended Liner: Zebron PLUS Single Taper Z-Liner (for Agilent systems) Liner Part No.: AG2-0A13-05 Carrier Gas: Helium @ 0.9 ml/min (constant flow) Oven Program: 260 C for 70 min Detector: FID @ 300 C Samples: Analytes were derivatized with Pyridine/BSTFA (3:1) 45 40 35 1 6 7 30 25 20 2 3 4 8 9 10 0 20 40 min App ID 24479 120 Adulterated Olive Oil:Extra Virgin Olive Oil/Canola Oil (50:50) Sample: 9 pa 100 80 60 1. Cholesterol 2. Cholestanol (internal standard) 3. Brassicasterol 4. Campesterol 5. Stigmasterol 6. Δ-7-campesterol 7. Δ-5,23-stigmastadienol 8. Clerosterol 9. β-sitosterol 10. Sitostanol 11. Δ-5-Avenasterol 12. Δ-5,24-Stigmastadienol 13. Δ-7-stigmastenol 14. Δ-7-Avenasterol 15. Erythrodiol 3 4 10 40 1 2 5 6 7 8 11 12 13 14 15 App ID 24480 0 20 40 min Phenomenex l WEB: www.phenomenex.com 9

Sterols from Olive Oil IOC Sterol Criteria for Virgin Olive Oil Classification Standard Name IOC Standard Criteria for Virgin Olive Oil Extra Virgin Olive Oil Adulterated Olive Oil % Recovery % RSD (n=3) % Recovery % RSD (n=2) Apparent β-sitosterol 93.0 % of total sterols 94.6 % 0.3 60.3 % 1.2 Cholesterol 0.5 % of total sterols not detected - 0.3 % 13.3 Brassicasterol 0.1 % of total sterols not detected - 8.7 % 0.7 Campesterol 4.0 % of total sterols 3.8 % 6.8 29.1 % 1.3 Stigmasterol Campesterol ( 4.0 % of total sterols) 1.0 % 9.0 0.6 % 45.0 Δ-7-Stigmastenol 0.5 % of total sterols not detected - 0.7 % 2.9 Uvaol + Erythrodiol 4.5 % of total sterols 1.8 % 31 0.3 % 1.0 Total Sterols 1000 mg/kg 1324 mg/kg 6 4221 mg/kg 1.0 Apparent β-sitosterol = β-sitosterol + Δ-5-avenasterol + Δ-5,23-stigmastadienol + clerosterol + sitostanol + Δ-5,24-stigmastadienol. Total sterols = cholesterol + 24-methylene cholesterol + brassicasterol + campesterol + campestanol + stigmasterol + Δ-7-campesterol + Δ-5,23-stigmastadienol + apparent β-sitosterol + Δ-7-avenasterol. To read full technical note, go to www.phenomenex.com and search TN-0114 10 Phenomenex l WEB: www.phenomenex.com

Start Your New SLE Method Synthetic SLE Novum SLE 96-Well Plates Novum Simplified Liquid Extraction SLE Well Plates 8E-S138-FGA Novum SLE MINI 96-Well Plate 1/pk 8E-S138-5GA Novum SLE MAX 96-Well Plate 1/pk Diatomaceous Earth SLE Strata DE 96-Well Plates Strata DE Diatomaceous Earth SLE Well Plates 8E-S325-FGB Strata DE SLE 200 µl 96-Well Plate 2/pk 8E-S325-5GB Strata DE SLE 400 µl 96-Well Plate 2/pk Novum Tubes Novum Simplified Liquid Extraction SLE Tubes 8B-S138-FAK Novum SLE 1 cc Tubes 100/pk 8B-S138-5BJ Novum SLE 3 cc Tubes 50/pk 8B-S138-JCH Novum SLE 6 cc Tubes 30/pk 8B-S138-KDG Novum SLE 12 cc Tubes 20/pk Strata DE Tubes Strata DE Diatomaceous Earth SLE Tubes 8B-S325-KDG Strata DE SLE 12 cc Tubes 20/pk 8B-S325-VFF Strata DE SLE 60 cc Tubes 16/pk If Phenomenex SLE products do not perform as well or better than your current SLE product, return the product with comparative data within 45 days for a FULL REFUND. Presston 100 Positive Pressure Manifold Presston 100 AH0-9342 Presston 100 Positive Pressure Manifold, 1 ml Tube Complete Assembly ea AH0-9347 Presston 100 Positive Pressure Manifold, 3 ml Tube Complete Assembly ea AH0-9343 Presston 100 Positive Pressure Manifold, 6 ml Tube Complete Assembly ea Vacuum Manifolds Vacuum Manfolds AH0-6023 12-Position Tube Vacuum Manifold Set ea AH0-6024 24-Position Tube Vacuum Manifold Set ea The Presston 100 96-Well Positive Pressure Manifold can also process 1, 3, and 6 ml tubes using the following adapter kits: Presston 100 Tube Adapter Kits (for AH0-9334) AH0-9344 1 ml Tube Adapter Kit ea AH0-9345 3 ml Tube Adapter Kit ea AH0-9346 6 ml Tube Adapter Kit ea Phenomenex warrants that for a period of 12 months following delivery, the Presston 100 Positive Pressure Manifold you have purchased will perform in accordance with the published specifications and will be free from defects in materials or workmanship. In the event that the Presston 100 Positive Pressure Manifold does not meet this warranty, Phenomenex will repair or replace defective parts. Please visit www.phenomenex.com/ Presston for complete warranty information. Phenomenex l WEB: www.phenomenex.com 11

Supported Liquid Extraction (SLE) For Food Applications Australia t: +61 (0)2-9428-6444 f: +61 (0)2-9428-6445 auinfo@phenomenex.com Austria t: +43 (0)1-319-1301 f: +43 (0)1-319-1300 anfrage@phenomenex.com Belgium t: +32 (0)2 503 4015 (French) t: +32 (0)2 511 8666 (Dutch) f: +31 (0)30-2383749 beinfo@phenomenex.com Canada t: +1 (800) 543-3681 f: +1 (310) 328-7768 info@phenomenex.com China t: +86 400-606-8099 f: +86 (0)22 2532-1033 cninfo@phenomenex Denmark t: +45 4824 8048 f: +45 4810 6265 nordicinfo@phenomenex.com Finland t: +358 (0)9 4789 0063 f: +45 4810 6265 nordicinfo@phenomenex.com France t: +33 (0)1 30 09 21 10 f: +33 (0)1 30 09 21 11 franceinfo@phenomenex.com Germany t: +49 (0)6021-58830-0 f: +49 (0)6021-58830-11 anfrage@phenomenex.com India t: +91 (0)40-3012 2400 f: +91 (0)40-3012 2411 indiainfo@phenomenex.com Ireland t: +353 (0)1 247 5405 f: +44 1625-501796 eireinfo@phenomenex.com Italy t: +39 051 6327511 f: +39 051 6327555 italiainfo@phenomenex.com Luxembourg t: +31 (0)30-2418700 f: +31 (0)30-2383749 nlinfo@phenomenex.com Mexico t: 01-800-844-5226 f: 001-310-328-7768 tecnicomx@phenomenex.com The Netherlands t: +31 (0)30-2418700 f: +31 (0)30-2383749 nlinfo@phenomenex.com New Zealand t: +64 (0)9-4780951 f: +64 (0)9-4780952 nzinfo@phenomenex.com Norway t: +47 810 02 005 f: +45 4810 6265 nordicinfo@phenomenex.com Portugal t: +351 221 450 488 f: 34 91-413-2290 ptinfo@phenomenex.com Spain t: +34 91-413-8613 f: +34 91-413-2290 esp info@phenomenex.com Sweden t: +46 (0)8 611 6950 f: +45 4810 6265 nordicinfo@phenomenex.com Switzerland t: +41 61 692 20 20 f: +41 61 692 20 22 swissinfo@phenomenex.com United Kingdom t: +44 (0)1625-501367 f: +44 (0)1625-501796 ukinfo@phenomenex.com USA t: +1 (310) 212-0555 f: +1 (310) 328-7768 info@phenomenex.com All other countries Corporate Office USA t: +1 (310) 212-0555 f: +1 (310) 328-7768 info@phenomenex.com www.phenomenex.com Phenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at international@phenomenex.com BR57311117_W Terms and Conditions Subject to Phenomenex Standard Terms and Conditions, which may be viewed at www. phenomenex.com. Trademarks Strata is a registered trademark and Novum, Synergi, Presston, Zebron, 5plus, Z-Liner, and SecurityGuard are trademarks of Phenomenex. Biotage and ISOLUTE are registered trademarks of Biotage AB Corp. Thermo Fisher and HyperSep are trademarks of Thermo Fisher Scientific. Agilent is a registered trademark and ChemElut is a trademark of Agilent Technologies, Inc. API 5000 is a trademark of AB SCIEX Pte. Ltd. AB SCIEX is being used under license. Disclaimer Phenomenex is not affiliated with Biotage AB Corp., Thermo Fisher Scientific, or Agilent Technologies, Inc. Novum is patent pending. 2018 Phenomenex, Inc. All rights reserved.