SPECIAL TOPIC. Cosmetic Dermatology Center, McLean, VA b. Art of Skin, MD, Solana Beach, CA c. Dermatology Associates, Seattle, WA

Similar documents
Long-term follow-up on patients treated for abdominal fat using a selective contactless radiofrequency device

Supplement to July/August 2015 CLINICAL CASE BOOK SELECTIVE RADIOFREQUENCY FAT REDUCTION IN PRACTICE

Since both the demand for body contouring and interest in

Operator Independent Focused High Frequency ISM Band for Fat Reduction: Porcine Model

Impact of Contactless Apoptosis-Inducing RF on Temperature of Human Skin Surface and Subcutaneous Layer as well as Porcine Histology: A Pilot Study

BODY BY BTL BECAUSE EVERY BODY MATTERS

A G E N D A. I. Non-Invasive Body Contouring II. Benefits III. Treatment Options IV. Treatment Zones V. Q&A VI. Media VII.Results

The efficacy of the treatment of abdominal cellulite and skin tightening with a Venus Freeze (MP) 2 -A pilot study.

Department of Dermatology Faculty of Medicine Siriraj Hospital, Mahidol University Bangkok, THAILAND

Awide range of technologies are available to perform esthetic

CLINICAL OVERVIEW. Clinical Studies Protocols Before & Afters

Personalized Body Sculpting: The Next Evolution

WHERE HEAT MEETS COLD

SPECIAL TOPIC. AboutSkin Dermatology & DermSurgery, Greenwood Village, CO b. The Aesthetic Clinique, Destin, FL c

Chapter 23 Devices for Weight Loss and Fatty Tissue

The only non-invasive procedure to build muscle and burn fat.

NOVEL MULTI-SOURCE PHASE-CONTROLLED RADIOFREQUENCY TECHNOLOGY FOR NON- ABLATIVE AND MICRO-ABLATIVE TREATMENT OF WRINKLES, LAX SKIN AND ACNE SCARS

Studies Confirm Exilis Elite s Advantages for Tightening and Shaping

An In-Depth Examination of Radiofrequency Assisted Liposuction (RFAL)

Arisa Ortiz, MD Director, Laser and Cosmetic Dermatology Assistant Clinical Professor Department of Dermatology UC San Diego

Full Body Contouring Experience

The Future of Body Contouring Minimally Invasive Procedures

Rumpa Linpiyawan, MD. Biography - Certified Board of Internal Medicine - Certified Board of Dermatology, Board of Family Medicine

Noninvasive Modalities in Lipolysis. Michelle W. Foley, DO, FAOCD, FAAD

Golden standard for non-invasive body shaping Focused

FEB-2015 ISSUE. Dr. David Pudukadan

BETTER THAN EVER. Brand new 360 technology for shorter treatments with more consistent outcomes.

LipoLaser. Lapex2000 LipoLaser. Changing the shape of your business

Clinical Efficacy and Statistical Evaluation of INTRAcel Treatment

Laser Effects on Skin Melanin

HISTOLOGICAL EVALUATION AFTER RADIOFREQUENCY TREATMENT FOR FACE REJUVENATION AND CELLULITIS

ONDA INNATE ABILITY. The Coolwaves TM Revolution. Smart and Enhanced Microwaves that Excel in All Body Contouring Applications:

Safety, Tolerance, and Patient Satisfaction With Noninvasive Cryolipolysis

Clinical effectiveness of non-invasive selective cryolipolysis

Radiofrequency in Cosmetic Dermatology

Evaluation of the wound healing response post deep dermal heating by fractional RF: INTRAcel

World Journal of Dermatology. Multi-channeling optimized radiofrequency energy: A new age in well-established radiofrequency technology

Focused Ultrasound Body-shaping system Beijing Sanhe Beauty S & T Co.,Ltd

A Smarter Way To Sculpt. Frequently Asked Questions

AESTHETICS CLINIC & ULTIMA GSTAAD

Evaluation of the wound healing response post - deep dermal heating by fractional RF: INTRACEL

doublo-s 2nd Generation HIFU For Intenal Purpose

body Reshape your body Renew your look Redefine you sculpting center Dramatic Aesthetic Results With a Spa-Like Feel

Quality survey on efficacy of carboxytherapy for localized lipolysis

shorter treatment duration. Lasers Surg. Med. 49:63 68, 2017.

Cryolipolysis Slimming Machine With Cavitation, RF, Lipo Laser User Manual

Physicians Praise Advancements in Body Shaping Technology. Emerging Technologies Review IMCAS 2014 Product Review Aesthetic Market Update

Focused Ultrasound Body shaping system

Thermage Radiofrequency for Noninvasive and Nonablative Body Contouring COS DERM

Performance Testing Clinical

Clinical effectiveness of non-invasive selective cryolipolysis

NEW IN-DEMAND AESTHETICS IN ONE PLATFORM TECH BREAKTHROUGH PLUS

Chapter 23 Unit 28. Therapeutic Modalities

Ultrasonic Cavitation. Collagen Facial Remodeling Body Shaping Slimming Cellulite Reduction Skin Tightening. Fat Elimination.

Syneron Raises the Bar in Energy-Based Body Shaping

CLINICAL STUDY REDUCTION OF LOCALIZED AND GENERALIZED ADIPOSE TISSUE BY CONTROLLED COOLING IN ABDOMEN AREA

Lipout. Burns stored fat and achieves centimetric reduction BODY SCULPTURE

PROFESSIONAL RECOVERY FOR SERIOUS ATHLETES. Vibrating 4 Speed Rechargeable Foam Roller Manual

Non-Ablative Rejuvenation

THERMOCRYOLIPIDE a novel method of fat reduction


Interesting Case Series. High-Intensity Focused Ultrasound in Aesthetic Plastic Surgery

Comparison of 635nm Red Light Transmission Through Skin and Subcutaneous Fat

Strong sound wave fat system

Hands-on: Lasers. NonAblative Rejuvenation

XF Microlens Optic and XD Microlens Compression Optic for Non-Ablative Fractional Skin Treatment with the Palomar Icon System

Dual modality body shaping study with RF and IR technologies utilizing SharpLight s FormaxPlus Platform.

The Shape of the Contouring Market: Expert Tips on Energy-based Body Treatments

Cryolipolysis Cool-sculpturing Slimming Machine

Superior RF Multi-Treatment Platform

Therapeutic Ultrasound

Bipolar Radio Frequency Beauty Device SE-ST34 User Manual

THE SHAPE OF THE CONTOURING MARKET: EXPERT TIPS ON ENERGY-BASED BODY TREATMENTS

Superior RF Multi-Treatment Platform

Your Subcutaneous Implantable Cardiac Defibrillator (ICD)

Battle of the Bulge with BodyTite The Latest Chapter in Liposuction

Princes Street, Dunedin

AESTHETIC TECHNOLOGIES. Proven Marketing and Aesthetic Technologies Designed to Maximize Your Earning Potential

12 th ANNUAL CONGRESS IMCAS INTERNATIONAL MASTER COURSE OF AGING SKIN JANUARY PARIS

Syllabus References. Resources. Video: MRI Introduction

The Art of Body Shaping

Glossary of Terms. Ablation- removal of tissue: the removal of unwanted tissue from the body by surgical or other means

Presentation Product & clinics

Needle free Mesotherapy

VelaShape II. Cellulite Treatment & Body Contouring. Science. Results.Trust.

Results and patient experience may vary.

The Biomet EBI Bone Healing System. Patient Manual

Cryolipolysis for noninvasive body contouring: clinical efficacy and patient satisfaction

Bella Contour Device. Real Aesthetics. Real Results.

Nonablative Infrared Skin Tightening in Type IV to V Asian Skin: A Prospective Clinical Study

IT S A FACT TECHNOLOGY EVOLVES. WE MAKE SURE YOU CAN TOO.

ALTERNATIVE TREATMENT

CTN Cryolipo Clinical Studies. Summary

Diode Lasers Enable Diverse Therapeutic Applications

Frequently Asked Questions

Overview SKABA7. Using radio frequency to rejuvenate the skin and improve body contour

NONABLATIVE RESURFACING

Reduces the appearance of cellulite and improves the appearance of the skin.

Very versatile tool for minor cosmetic procedures High frequency AC radiowaves generate cellular heat Cells vaporised Radiowaves pass through the

Transcription:

December 2016 1557 Volume 15 Issue 12 Copyright 2016 ORIGINAL ARTICLES Journal of Drugs in Dermatology SPECIAL TOPIC A Clinical Evaluation of a Next Generation, Non-Invasive, Selective Radiofrequency, Hands-Free, Body-Shaping Device Nicole Hayre MD, a Melanie Palm MD, b and Peter Jenkin MD c a Cosmetic Dermatology Center, McLean, VA b Art of Skin, MD, Solana Beach, CA c Dermatology Associates, Seattle, WA ABSTRACT Objective: The aim of this study was to compare clinical outcomes of a noninvasive selective radiofrequency (RF) field device (BTL Vanquish ME, BTL Industries Inc., Boston MA) with its predecessor (Vanquish, BTL Industries Inc., Boston MA). The BTL Vanquish ME system has been thoroughly redesigned for more efficient, predictable and homogenous energy delivery to the targeted tissue. Materials and Methods: In this multi-center study, 36 subjects with BMIs under 30 were randomly assigned to be treated in Group A (BTL Vanquish ME ) or Group B (Vanquish ) in order to obtain a side by side comparison of the devices efficacies. Each subject received 4 weekly 45-minute treatments with the device determined by their group assignments. Measurements of subject s abdominal fat were taken prior to the first treatment and again four weeks after finishing the final treatment. Results: The primary outcome was abdominal fat thickness reduction as measured by ultrasound one month following each subject s final treatment. Thirty four subjects completed the study. Two patients did not complete their treatments due to the reasons unrelated to the study (one from each group). Subjects in Group A treated with BTL Vanquish ME had an abdominal fat thickness reduction of 4.17 mm, or 29.46%, while subjects in Group B treated with Vanquish had an abdominal fat thickness reduction of only 2.72 mm, or 15.21%. The 4 weekly treatments with BTL Vanquish ME in Group A produced a 53% higher reduction (4.17 mm vs 2.72 mm) of abdominal fat layer thickness than those in Group B. The standard deviation of ultrasound measurements in Groups A and B were 1.42mm and 2.21mm, respectively. Assuming a homogenous response across the entire treatment area, the volume of fat reduced was calculated by multiplying the average measured reduction in fat layer by the surface area of the treatment applicator (2100 cm2; 325.5 square inches). It was calculated that Group A patients lost an average of 0.876 liter (0.23 liquid gallon) of fat, while Group B patients lost 0.571 liter (0.15 liquid gallon) of fat. Discussion and Conclusion: The mean difference between the tested groups was statistically significant proving better outcomes in the Vanquish ME than its predecessor. Furthermore, the reduction in standard deviation of fat reduction measurements in Group A vs Group B is evidence that the Vanquish ME provides more consistent performance. J Drugs Dermatol. 2016;15(12):1557-1561. INTRODUCTION Radiofrequency energy generates electric current which irradiates the targeted tissue. When this electric current meets resistance in the tissue, it produces heat. It is the heat generated which induces the desired changes in the body. This method has emerged as an effective, noninvasive, aesthetic treatment modality for body contouring and fat reduction. The medical use of RF is based on an oscillating electrical field that forces collisions between charged molecules and ions, causing molecular friction, which is then transformed into heat. Selective RF technology allows for noninvasive and preferential heating of large volumes of subcutaneous adipose tissue. By choosing the electric field s conductivity and relative permittivity, it is possible to selectively achieve greater heating of fat. Under normal conditions, the orientation of dipoles in the adipose tissue is random. Polarization forces these dipoles to rotate and orientate in one direction. Dielectric polarization induces each electrical dipole to rotate against the polarization of the electrical field. With a rapidly alternating electromagnetic field, the electrical dipoles oscillate back and forth, creating molecular friction. This causes the fatty tissue to heat up, which is the principle mechanism of action of selective RF fields on fat. The contactless selective radiofrequency device is designed to deliver noncontact transcutaneous selective RF, generate heat specifically in subcutaneous adipose tissue, and to induce adipocyte apoptosis with only minimal effect on skin and muscle. Muscle and skin have different conductivity and relative permittivity than fat; water in skin contributes to its low impedance while subcutaneous adipose tissue has high impedance. The applicator-generator circuitry is engineered to selectively deliver the energy to the adipose tissue layer. The contactless selective

1558 radiofrequency system focuses energy specifically into the adipose tissue layer, while limiting the delivery to the dermis, epidermis, and muscles. A selective RF field applicator shapes the electro-magnetic field to optimize the penetration and maximize the treatment area. In addition, the applicator is equipped with Energy Flow Control (EFC ). EFC automatically tunes the tissue-applicator-generator circuitry to selectively deliver the energy to the adipose tissue layer while minimizing the risk of overheating in the skin, muscles, or internal organs. This effect was demonstrated and substantiated by pathologic and histologic findings in an in vivo porcine model. 1 Pathological examination clearly demonstrated fat layer reduction in the treated area. Microscopic photographs of histology and TUNEL staining for apoptosis showed that the reduction was caused by the apoptotic phenomenon. Histologic evaluation revealed that the epidermis, dermis, and hair follicles were unaffected by the treatment, while adipocytes were significantly affected. Thermocouples used to monitor irradiated tissue temperature during the procedure showed that the adipose tissue was gradually heated up to the temperature of 46 C while the skin temperature reached only 42 C. These findings confirmed that non-contact selective RF was safe and effective for subcutaneous fat reduction in this porcine animal model. Laboratory, histological, or gross pathological analyses did not indicate any safety risks or side effects. These findings opened a path to contact-free selective RF use for the reduction of human adipose tissue in clinical practices. A human study was consistent with the results of the animal study in terms of temperature elevation in the irradiated adipose tissue and TUNEL staining for increase in apoptotic index in adipocytes 1 hour after a 45-minute, non-contact selective RF treatment. 5 Other published reports and studies further demonstrate the safety and efficacy of contactless selective RF treatment for abdominal fat reduction. 2-7 Presently, both the BTL Vanquish and BTL Vanquish ME (BTL Industries Inc., Framingham, MA) are the only radiofrequency devices on the US aesthetic market that allow for non-contact, hands-free treatment of subcutaneous fat. They are multipolar radiofrequency devices that are designed and cleared for deep tissue heating for the purpose of achieving a circumferential reduction of the abdomen and thighs. Recently, the Vanquish system was redesigned to improve its tuning circuit. This improvement, in combination with its newly designed applicator, enables homogenous energy delivery to the tissue in a more efficient and predictable way. TABLE 1. Composition of Subject Groups BTL VANQUISH ME Subjects Group A Initial BMI Age Sex BTL VANQUISH Subjects Group B Initial BMI Age Sex 1 25 34 M 18 26 45 F 2 28 26 F 19 25 34 F 3 26 47 F 20 27 55 F 4 29 38 F 21 25 47 M 5 24 25 M 22 24 32 F 6 27 33 F 23 29 36 F 7 26 42 F 24 25 22 F 8 25 53 M 25 26 37 F 9 28 44 M 26 26 56 M 10 27 48 F 27 26 27 M 11 27 53 F 28 27 43 F 12 24 56 F 29 27 38 F 13 25 46 F 30 26 44 F 14 26 32 F 31 25 24 F 15 24 44 F 32 23 48 F 16 26 38 F 33 24 53 F 17 26 54 F 34 24 48 F AVG 26.06 25.59

1559 TABLE 2. Exclusionary Criteria 1. BMI > 30. 2. Surgical procedure in the treatment area in the past 6 months. 3. Invasive fat reduction procedure (e.g. liposuction, abdominoplasty) in the treatment area in the past year. 4. Concurrent therapy with any medication or device either topical or oral that might interfere with the study. 5. Not willing to maintain current dietary and lifestyle for the duration of the study period. 6. Pregnant, lactating or planning a pregnancy during the study. 7. Active systemic or local skin disease that may affect wound healing. 8. Dermatological conditions or scars in the location of the treatment area. 9. Metal implants (excluding oral implants). 10. Active implant such as pacemaker, defibrillator/cardio converter, cochlear implant. 11. Active, systemic autoimmune diseases. This clinical study was conducted to evaluate how the improvements to BTL Vanquish ME impact efficacy and patient outcomes as compared to the BTL Vanquish. MATERIALS AND METHODS Thirty-six subjects were randomly assigned for a series of treatments in one of two groups: Group A BTL Vanquish ME or Group B - Vanquish. The subjects in Group A had an average BMI of 26.06 and their ages ranged from 25 to 56 years old, while the subjects in Group B had an average BMI of 25.59 and an age range of 22 to 56 years old. Each group was predominantly female (Table 1). Exclusionary criteria included a BMI over 30 and previous fat reduction treatments on the abdomen in the past year (Table 2). Each subject received 4 weekly 45-minute treatments on their abdomen with the device determined by their group assignment. Subjects were instructed to maintain their usual diet and lifestyle throughout the duration of the study. Each subject s abdominal fat layer thickness was measured by ultrasound before beginning the study and 1 month after the last treatment. One subject in each group dropped out of the study during the treatment stage for reasons unrelated to study. RESULTS Analysis of the study groups showed no statistical difference in average abdominal fat layer thickness prior to the study [Group A 18.51±4.21 mm (range 11.6 24.7 mm) vs Group B 18.01±5.81 mm (range 13.0 30.4 mm)]. Thirty-four subjects completed the study, with two leaving it due to reasons unrelated to the study. There were no reports of serious adverse events or device malfunctions. Side effects were mild and transient and included post treatment erythema and tissue tenderness which resolved within an hour after the treatment. FIGURE 1. Ultrasound Abdominal Fat Thickness Measurement in Patient Treated with BTL Vanquish ME : (A) Before treatments; (B) 1-month post final treatment. (0.5 square inches). This assumes an homogenous response to treatment. (A) (B)

1560 FIGURE 2. Ultrasound Abdominal Fat Thickness Measurement in Patient Treated with VanquishTM: (A) Before treatments; (B) 1-month post final treatment. (A) (B) TABLE 3. Composition of Subject Groups GROUP A BTL VANQUISH METM GROUP B VANQUISHTM Subject # Ultrasound Measurement (mm) Change Ultrasound Measurement (mm) Change Subject # Before Tx After Tx mm % Before Tx After Tx mm % 1 11.6 9.2 2.4 20.69 18 21.6 20.2 1.4 6.48 2 15.9 12 3.9 32.5 19 19.6 18.2 1.4 7.14 3 20.1 15.8 4.3 27.22 20 13 9.8 3.2 24.62 4 23.3 16.7 6.6 39.52 21 13.9 10.9 3 21.58 5 12.7 9.6 3.1 32.29 22 14.6 12.9 1.7 11.64 6 15.3 10.5 4.8 45.71 23 30.4 20 10.4 34.21 7 16.2 12 4.2 35 24 15 10.8 4.2 28 8 14.1 10 4.1 41 25 12.9 10.6 2.3 17.83 9 24.7 18.1 6.6 36.46 26 27 23.1 3.9 14.44 10 17.9 12.2 5.7 46.72 27 25 23.3 1.7 6.8 11 20.3 15 5.3 35.33 28 14.6 11.4 3.2 21.92 12 19 14.8 4.2 28.38 29 11.9 9.9 2 16.81 13 14 11.6 2.4 20.69 30 20 17.7 2.3 11.5 14 22.8 18 4.8 21.05 31 25 23.7 1.3 5.2 15 24.6 22.4 2.2 8.94 32 14.6 13.9 0.7 4.79 16 22.3 18 4.3 19.28 33 13.2 12 1.2 9.09 17 19.9 17.9 2 10.05 34 13.9 11.6 2.3 16.55 Av±SD 18.51±4.21 14.34±3.81 4.17±1.42 29.46 18.01±5.82 15.29±5.15 2.72±2.21 15.21

1561 Abdominal fat layer thickness reduction at 30 days post treatment 4 was the primary outcome measurement in the study as measured by ultrasound. Examples of fat layer thickness measurements are presented in Figure 1 (Group A, subject #1) and Figure 2 (Group B, subject #18). Every subject in the study showed a reduction in the abdominal fat layer thickness. Reduction ranged from 2.0 to 6.6 mm in Group A (BTL Vanquish ME ) and 0.7 to 10.4 mm in Group B (Vanquish TM ). The average reduction in abdominal fat thickness in Group A was 4.17±1.42 mm and in Group B was 2.72±2.21 mm, which equates to reductions of 29.5% and 15.2%, respectively (Table 3). The degree of change in the abdominal fat layer thickness between Group A and B was statistically significant (P<0.008). Using the measured reduction in fat layer thickness and the treatment surface area of the applicator (2100 cm 2 or 325.5 square inches), a reduction of 0.876 liter (0.23 liquid gallon) and 0.571 liter (0.15 liquid gallon) of fat were calculated for Groups A and B, respectively. (Volume lost = fat layer thickness reduction x effective area or spot size of the applicator (2100 cm 2 ; 325). 2. Fajkošová K, Machovcová A, Onder M, Fritz K. Selective Radiofrequency Therapy as a Non-Invasive Approach for Contactless Body Contouring and Circumferential Reduction. J Drugs Dermatol. 2014;13(3):291-296. 3. Key DJ. Preliminary demonstration using localized skin temperature elevation as observed with thermal imaging indicator of fat-specific absorption during focused-field radiofrequency therapy. J Drugs Dermatol. 2014;13(7):864-866. 4. Ellis LS. Online temperature measurement: case study. Body Language. November 2014. 5. McDaniel D, Lozanova P. Human adipocytes apoptosis immediately following high frequency focused field radio frequency: Case study. J Drugs Dermatol. 2015;14(6):622-623. 6. Moradi A, Palm M. Selective non-contact field radiofrequency extended treatment protocol: Evaluation of safety and efficacy. J Drugs Dermatol. 2015;14(9):982-985. 7. Downie J, Kaspar M. Contactless abdominal fat reduction with selective RF evaluated by Magnetic Resonance Imaging (MRI): case study. J Drugs Dermatol. 2016;15(4):491-495. AUTHOR CORRESPONDENCE Nicole Hayre MD E-mail:...... drhayre@yahoo.com DISCUSSION The BTL Vanquish ME was engineered to have improved energy delivery to the targeted fat layer over the original Vanquish device. This improvement was proven to produce larger reductions in the targeted fat layer as shown by ultrasound images (Figure 1 and 2), with a statistically significant difference in the reduction of abdominal fat layer from an average of 2.72mm in the Vanquish to 4.17mm in the Vanquish ME. This improved reduction seen after four weekly treatments can also be calculated to be a 0.876 liter loss versus 0.571 liter. Improved tissue targeting and clinical results are also shown by a smaller range of fat loss in Group A versus Group B (1.42 vs 2.21), indicating more consistent effects on the target tissue. Patients with a higher BMI seeking fat reduction who prefer to avoid invasive procedures can successfully and safely be treated with Vanquish ME. There were only transient minor side effects after treatments, and each subject showed a measured reduction in abdominal fat. The sizable applicator can easily cover the abdomen and flanks in a single application, allowing for a large reduction in volume of fat, rivaling invasive liposuction results. DISCLOSURES Dr. Melanie Palm is a paid speaker and clinical investigator for BTL Aesthetics. Dr. Peter Jenkin is a paid speaker for BTL Aesthetics. REFERENCES 1. Weiss R, Weiss M, Beasley K, Vrba J, Bernardy J. Operator Independent Focused High Frequency ISM Band for Fat Reduction: Porcine Model. Lasers Surg Med. 2013;45:235 239.