Sepax Technologies, Inc.

Similar documents
Analytical and Preparative SFC Columns

Ultra Columns. also available. ordering note

Ultra Columns HPLC COLUMNS

Eurospher II the logical choice. Physical properties of Eurospher II silica gel: Silica gel: ultra pure, > % Metal content: < 10 ppm

Agilent Technologies Prep LC Columns

Chromatogram Search Tool Search by compound name, synonym, CAS # or keyword Pinnacle II Columns

Roc On with These Dependable LC Columns

C30 ISOMERS HAVE MET THEIR MATCH

Restek Ultra II HPLC Columns

ACE C18-AR Use the Power!

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis

SeQuant ZIC -HILIC For all who expect more...

Hyper-fast & Super-rugged

ACE CN-ES. Extra Stability. Extended Spacer. Enhanced Selectivity ACE. Combining CN polar selectivity with enhanced hydrophobicity

SeQuant ZIC -HILIC For all who expect more...

Thermo Scientific Hypersil BDS Columns

Fortis Method Development Options

YMC HILIC Columns for Polar Analytes

CE Columns and Accessories

Sepax Technologies, Inc.

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

176 YMC Chiral Columns

Unequalled durability against water elution. % tr

Normal Phase Chemistries

Choosing Preparative Columns

LC/MS Analysis of Various Hydrophilic Compounds Using a Polymer-Based Amino Column - Shodex TM HILICpak TM VG-50 2D

LC Columns with Liquid Separation Cell Technology

LC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined

Reversed-Phase Columns (Other than ODS)

HPLC. Varian Dynamax Preparative HPLC Columns

SPE Cartridges. All Finneran Products Are Certified. Conditioning Sample application Wash Elution

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE

InertSustain Phenylhexyl. A New Second Choice Column to Change Chromatographic Behavior

Kromasil The way to peak performance in liquid chromatography

Chapter 22: Gas and Liquid Chromatography. Liquid Chromatography: Stationary Phases and Mobile Phases: Normal Phase: Reversed Phase:

Separation of Vitamin D and Vitamin D Metabolites on FLARE C18 MM (Mixed Mode) HPLC Column

3 Normal-Phase Columns. Reversed-Phase C18 Columns (ODS) Reversed-Phase Columns (Other than ODS) Columns for HTS and LC/MS Analysis.

Separation of Macrocyclic Lactones (Avermectins) on FLARE C18 MM & FLARE C18+ Columns

Am I getting the very best value from my UHPLC analyses?

The Raptor HILIC-Si Column

GlycanPac AXR-1 Columns

Normal Phase HPLC Column COSMOSIL SL-II

HIGH PERFORMANCE SEPARATION PHASES

Supra-Clean and Supra-Poly Solid Phase Extraction (SPE) Solutions

HPLC Separation Tools for Membrane Protein Purification and Drug Membrane Permeability Prediction

Hypersil BDS and Hypersil Classical HPLC Columns

The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns.

Studies on Stationary Phase Selectivity for Solid-Core Particles

InertSustainBio C18. Rapid Separations of Proteins and Peptides

Impurity Profiling of Carbamazepine by HPLC/UV

Purification - Flash Chromatography

Application Note. Separation of clindamycin phosphate and process impurities. Summary. Introduction. Category Pharmaceutical analysis Matrix

Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases

Analysis of HMF by HPLC

High-Throughput Separations for QA/QC, LC/MS, LC/MS/MS, Combinatorial Chemistry and Rapid Method Development

VertiSep TM PRP. HPLC Columns. VertiSep TM PRP HPLC Columns

HICHROM. Chromatography Columns and Supplies NEW PRODUCTS. Catalogue 9. Hichrom Limited

UNISON UK - Amino For Aqueous Elutions and Exceptional Separation Balance

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

Core-Shell Technology for Proteins and Peptides

COSMOSIL HILIC. HPLC Column for Hydrophilic Interaction

Systematic Evaluation of Solid Phase Extraction (SPE) Chemistries for the Determination of Acidic, Neutral, and Basic Drugs

Probing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection INTRODUCTION

Authors. Abstract. Introduction. Environmental

Methotrexate. (Ph. Eur. monograph 0560) C 20 H 22 N 8 O Action and use. Dihydrofolate reductase inhibitor; cytostatic.

Application Note. Abstract. Authors. Pharmaceutical

HxSil C18, 4.6 x 150mm, 5um (P/N 79868) 1. Oxybenzone 2. Octocrylene 3. Octyl Methoxycinnamate 4. Avobenzone (Parsol 1789) 5.

Achiral SFC: Development of an Orthogonal SFC Method for Mometasone Furoate Impurity Analysis

Prep Columns. and Bulk Media. and Bulk Media

Tosoh Bioscience llc Distributed by Phenomenex in the USA, Canada, and Puerto Rico only.

Ultimate Core Performance to Maximize Your Investment

Simultaneous Analysis of Active Pharmaceutical Ingredients and Their Counter-Ions Using a Mixed-Mode Column

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate

Catalogue. Resins and Columns For High Performance Liquid Chromatography

Rebaudioside a From Multiple Gene Donors Expressed in Yarrowia Lipolytica

Using Hydrophilic Interaction Chromatography (HILIC) for the Retention of Highly Polar Analytes

Selectivity Comparison of Agilent Poroshell 120 Phases in the Separation of Butter Antioxidants

Converting a CHP Method for Insulin to Agilent Poroshell 120 Columns

Gerry Hendrickx Regional Sales Manager Central Europe. Developments in Waters Column Chemistries : BEH Technology

YMC-Actus. Columns for Semi-preparative HPLC. Selectivity Durability Loadability

InertSustain Amide 技術資料

Insulin SEC analysis. Insulin Samples:

A New Era in SFC Column Technology

Maximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system

Preparative HPLC columns Eurospher II for semipreparative and preparative HPLC

Thermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific

GlycanPac AXH-1 Columns

Low Pressure Chromatography. SiliaBond Chromatographic Phases SiliaSep Flash Cartridges

Title Revision n date

Tenofovir disoproxil fumarate (Tenofoviri disoproxili fumaras)

Physical Properties. Silica

Exceed your Purification Goals. Guaranteed. Phenomenex l WEB:

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Transfer and Speed-up of Methods to Fused-Core Particle Columns EPA Method 1694

TENOFOVIR TABLETS: Final text for addition to The International Pharmacopoeia (June 2010)

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit

Small Scale Preparative Isolation of Corticosteroid Degradation Products Using Mass-Based Fraction Collection Application

Facile Isolation of Carotenoid Antioxidants from Solanum lycopersicum using Flash Chromatography

Transcription:

Sepax Technologies, Inc. Sepax Technologies, Inc. develops and manufactures products in the area of chemical and biological separations, biosurfaces and proteomics. Sepax product portfolio includes ) liquid chromatography columns and media, ) SPE and Flash chromatography columns and tubes, ) bulk resin for preparative separation and process chromatography, and ) natural product and Chinese traditional medicine separation and purification. Super Critical Fluid Chromatography Sepax SFC-Pyridine... Sepax SFC-SCX... Sepax SFC-Diol... Sepax SFC-Cyano... Sepax SFC-Amino... 6 Sepax SFC-Silica... 7 Column price list... 8- www.sepax-tech.com -877-SEPAX-US

AU Sepax SFC-Pyridine SFC test chromatogram Si Si CH CH N Vendor X N(#)=, Silica: Spherical, high purity (< ppm metals) Pore size: Å Particle size:.8,.,,, 7, and m Pore volume:. ml/g Surface area: m /g Phase structure: Polymeric and no endcapping % Carbon: 8.% Coverage: ~. mol/m.7.6...... 6 8 6 8 Column: SFC-Pyridine (µm, Å,.6xmm) Mobile phase: 8% Hexane/% Ethanol Flow rate:. ml/min Detector (UV): nm Injection volume:. µl Temperature: Ambient ( o C) Sample:. Pyridine. Aniline. Phenol. Uracil. p-aminobenzoic acid 6 Vendor Y N(#)=8,86 Sepax N(#)=8, 7 8 Column: Pyridine phases (µ,.6x mm) Mobile phase: C /MeH Gradient: t (min) 6 7 8 9 MeH(%) Flow rate:. ml/min Detection (DAD): nm Instrument: Berger Analytical SFC Sample:. Dimethylphthalate. Caffeine. Uracil. Cortisone Well controlled chemistry of polymeric monolayer High column-to-column reproducibility Recommended for separations of acidic, neutral and basic organic compounds, as well as the pharmaceuticals Sepax SFC-Pyridine Products SFC-Pyridine Pore size P/N m,.6xmm Å 69-6 m,.6xmm Å 69-6 m,.6xmm Å 69-6 m,.xmm Å 69- m,.xmm Å 69- m,.xmm Å 69- m, xmm Å 69- m, xmm Å 69- m, xmm Å 69-9 www.sepax-tech.com -877-SEPAX-US

Sepax SFC-SCX Phase Structure Si Si Si Technical Specifications Silica: Spherical, high purity (< ppm metals) Pore size: Å Particle size:.8,.,,, m Pore volume:. ml/g Surface area: m /g Phase structure: Polymeric and mixed mode % Carbon:.% Coverage:. mol/m Description Sepax SFC-SCX is a silica based mixed-mode strong cation exchange phase. Its phase has a mixed chemical structure of sulfonic acid and phenyl group. This mixed mode of strong cation-exchange and hydrophobicity offers high selectivity and high resolution separation for cationic/basic and nitrogen containing compounds as well as desirable retention for a variety of weak cationic and neutral organic compounds. A uniform, polymeric bonding of Sepax SFC- SCX enhances its stability under various separation conditions. Sepax SFC-SCX has expanded its applications from the traditional SCX separation of cationic and nitrogen containing compounds to weak cationic and neutral organic molecules. Examples include separation of analytes of amines and polyamines, such as alkaloids, peptides, codeine, cough and cold ingredients. S H Highly controlled chemistry of polymeric monolayer formation and end-capping Mixed chemical structure of sulfonic acid and phenyl group Mixed-mode of ion-exchange and hydrophobic interaction enabling high selectivity and appropriate retention for a variety of compounds Polymeric bonding and end-capping to achieve the exceptionally high stability ph stability:.-8. Suitable for separations of a complex of cationic, nitrogen containing, and neutral compounds mau 8 6 Column: Sepax SFC-SCX (.6x mm, m) Mobile phase: mm phosphate buffer, ph. Flow rate:. ml/min (8 bar) Detector: UV 8 nm Injection volume: L Temperature: Ambient ( o C) Compounds:. Uridine (. mg/ml). Cytidine (. mg/ml). Guanosine (. mg/ml). Inosine and impurities (. mg/ml). Adenosine (. mg/ml) 6 8 min Sepax SFC-SCX Products Sepax SFC-SCX Pore size P/N m,.6xmm Å 66-6 m,.6xmm Å 66-6 m,.6xmm Å 66-6 m,.xmm Å 66- m,.xmm Å 66- m,.xmm Å 66- m, xmm Å 66- m, xmm Å 66- m, xmm Å 66- www.sepax-tech.com -877-SEPAX-US

AU mau Sepax SFC-Diol SFC test chromatogram 7 Si Si CH CH CH H CH CHCH H 6 nm (N=6,) Silica: Spherical, high purity (< ppm metals) Pore size: Å Particle size:.8,.,,, m Pore volume:. ml/g Surface area: m /g Phase structure: Monomeric and fully endcapped % Carbon: 8.8% Coverage: ~. mol/m.8.7.6. nm 6 7 Column: Sepax SFC-Diol (µ,.6x mm) Mobile phase: C /MeH Gradient: t (min) 6 7 8 9 MeH(%) Flow rate:. ml/min Detection (DAD): nm Instrument: Berger Analytical SFC Sample:. Dimethylphthalate. Caffeine. Uracil. Cortisone 8 9..... 6 7 8 9 Well controlled chemistry of polymeric monolayer High column-to-column reproducibility Polar phase for separations of acidic, neutral and basic organic compounds, as well as the pharmaceuticals High selectivity and efficiency for separations Sepax SFC-Diol Products Column: SFC-Diol (µm, Å,.6xmm) Mobile phase: 8% Hexane/% Ethanol Flow rate:. ml/min Detector (UV): nm Injection volume:. µl Temperature: Ambient ( o C) Sample:. Phenol. -Nitrophenol.,-Biphenol Sepax SFC-Diol Pore size P/N m,.6xmm Å 66-6 m,.6xmm Å 66-6 m,.6xmm Å 66-6 m,.xmm Å 66- m,.xmm Å 66- m,.xmm Å 66- m, xmm Å 66- m, xmm Å 66- m, xmm Å 66- www.sepax-tech.com -877-SEPAX-US

AU mau Sepax SFC-Cyano SFC test chromatogram Si CH Si (CH ) CN 7 6 CH Silica: Spherical, high purity (< ppm metals) Pore size: Å Particle size:.8,.,,, m Pore volume:. ml/g Surface area: m /g Phase structure: Monomeric and fully endcapped % Carbon: 7.% Coverage: ~. mol/m.6. (N=,6) Sym=.7 (N=,) 6 7 8 Column: Sepax SFC-Cyano (µ,.6x mm) Mobile phase: C /MeH Gradient: t (min) 6 7 8 9 MeH(%) Flow rate:. ml/min Detection (DAD): nm Instrument: Berger Analytical SFC Sample:. Dimethylphthalate. Caffeine. Uracil. Cortisone 9..... 6 7 8 9 Highly controlled chemistry of monolayer formation and end-capping Extremely high column-to-column reproducibility High selectivity and efficiency for separations Suitable for separations of acidic, neutral and basic organic compounds, and pharmaceuticals Sepax SFC-Cyano Products Column: SFC-Cyano (µm, Å,.6xmm) Mobile phase: % Acetonitrile/% H Flow rate:. ml/min Detector (UV): nm Injection volume:. µl Temperature: Ambient ( o C) Sample:. -Cyanophenol. Anisole. Benzophenone The SFC-Cyano packing materials are bonded with propyl cyano functional groups that enable special interaction with polar compounds. The monomeric bonding chemistry produces very high efficiency and high resolution separations. Sepax SFC-Cyano Pore size P/N m,.6xmm Å 6-6 m,.6xmm Å 6-6 m,.6xmm Å 6-6 m,.xmm Å 6- m,.xmm Å 6- m,.xmm Å 6- m, xmm Å 6- m, xmm Å 6- m, xmm Å 6- www.sepax-tech.com -877-SEPAX-US

AU Sepax SFC-Amino Si Si Silica: Spherical, high purity (< ppm metals) Pore size: Å Particle size:,, 7 and m Pore volume:. ml/g Surface area: m /g Phase structure: Polymeric and no endcapping % Carbon:.% Coverage: ~.6 mol/m (CH ) NH Well controlled chemistry of polymeric monolayer High column-to-column reproducibility Utilized as both SFC and LC phases Versatile mobile phases: non-aqueous solvents, such as hexane/ethyl acetate and chloroform/methanol, and aqueous solutions Recommended for separations of pharmaceuticals, saccharides, nucleotides, and basic organic compounds Sepax SFC-Amino Products Sepax SFC-Amino Pore size P/N m,.6xmm Å 6-6 m,.6xmm Å 6-6 m,.6xmm Å 6-6 m,.xmm Å 6- m,.xmm Å 6- m,.xmm Å 6- m,.xmm Å 6- m, xmm Å 6- m, xmm Å 6- m, xmm Å 6- m, xmm Å 6-.. Peak N=, Sym=..... 6 8 6 8 Column: SFC-Amino (µm, Å,.6xmm) Mobile phase:.7% EtH/.% H /8% Isooctane Flow rate:. ml/min Detector (UV): nm Injection volume:. µl Temperature: Ambient ( o C) Sample:. Toluene. Benzanilide. p-nitroaniline www.sepax-tech.com 6-877-SEPAX-US

AU mau Sepax SFC-Silica Si H Suitable for separations in aqueous and non-aqueous mobile phases Suitable for separations of polar and basic organic compounds, such as vitamins, steroids, as well as pharmaceuticals SFC test chromatogram,, Silica: Spherical, high purity (< ppm metals) Pore size: Å Particle size:,, 7 and m Pore volume:. ml/g Surface area: m /g Phase structure: activated hydroxyl (-H) % Carbon: %, 9 8 7 6 (N=7,).7.6.... Peak N=,6 Sym=. 6 7 8 Column: Sepax SFC-Silica (µ,.6x mm) Mobile phase: C /MeH Gradient: t (min) 6 7 8 9 MeH(%) Flow rate:. ml/min Detection (DAD): nm Instrument: Berger Analytical SFC Sample:. Dimethylphthalate. Caffeine. Uracil. Cortisone 9.. 6 8 6 8 Column: SFC-Silica (µm, Å,.6xmm) Mobile phase:.7% EtH/.% H /8% Isooctane Flow rate:. ml/min Detector (UV): nm Injection volume:. µl Temperature: Ambient ( o C) Sample:. Toluene. Benzanilide. p-nitroaniline Activated silica surface Ultra high purity Enhanced mechanical stability Sepax SFC-Silica Products Sepax SFC-Silica Pore size P/N m,.6xmm Å 67-6 m,.6xmm Å 67-6 m,.6xmm Å 67-6 m,.xmm Å 67- m,.xmm Å 67- m,.xmm Å 67- m, xmm Å 67- m, xmm Å 67- m, xmm Å 67- www.sepax-tech.com 7-877-SEPAX-US

rdering Information.8 m Analytical Columns (length x ID mm) Phases.x.x.x.x.x.x SFC-Cyano ( Å) 6-6- 6-6- 6-6- SFC-NH ( Å) 6-6- 6-6- 6-6- SFC-SCX ( Å) 66-66- 66-66- 66-66- SFC-Pyridine (Å) 69-69- 69-69- 69-69- SFC-Diol ( Å) 66-66- 66-66- 66-66- SFC-Silica ( Å) 67-67- 67-67- 67-67-.8 m Analytical Columns (length x ID mm) Phases.x.x.6x.6x.6x.6x SFC-Cyano ( Å) 6-6- 6-6 6-6 6-6 6-6 SFC-NH ( Å) 6-6- 6-6 6-6 6-6 6-6 SFC-SCX ( Å) 66-66- 66-6 66-6 66-6 66-6 SFC-Pyridine (Å) 69-69- 69-6 69-6 69-6 69-6 SFC-Diol ( Å) 66-66- 66-6 66-6 66-6 66-6 SFC-Silica ( Å) 67-67- 67-6 67-6 67-6 67-6. m Analytical Columns (length x ID mm) Phases.x.x.x.x.x.x SFC-Cyano ( Å) 6-6- 6-6- 6-6- SFC-NH ( Å) 6-6- 6-6- 6-6- SFC-SCX ( Å) 66-66- 66-66- 66-66- SFC-Pyridine (Å) 69-69- 69-69- 69-69- SFC-Diol ( Å) 66-66- 66-66- 66-66- SFC-Silica ( Å) 67-67- 67-67- 67-67-. m Analytical Columns (length x ID mm) Phases.x.x.6x.6x.6x.6x SFC-Cyano ( Å) 6-6- 6-6 6-6 6-6 6-6 SFC-NH ( Å) 6-6- 6-6 6-6 6-6 6-6 SFC-SCX ( Å) 66-66- 66-6 66-6 66-6 66-6 SFC-Pyridine (Å) 69-69- 69-6 69-6 69-6 69-6 SFC-Diol ( Å) 66-66- 66-6 66-6 66-6 66-6 SFC-Silica ( Å) 67-67- 67-6 67-6 67-6 67-6 m Analytical Columns (length x ID mm) Guard column Phases.x.x.x.x.x.x * SFC-Cyano ( Å) 6-6- 6-6- 6-6- SFC-NH ( Å) 6-6- 6-6- 6-6- SFC-SCX ( Å) 66-66- 66-66- 66-66- SFC-Pyridine (Å) 69-69- 69-69- 69-69- SFC-Diol ( Å) 66-66- 66-66- 66-66- SFC-Silica ( Å) 67-67- 67-67- 67-67- www.sepax-tech.com 8-877-SEPAX-US

m Analytical Columns (length x ID mm) Guard column Phases.6x.6x.6x.6x.6x.x * SFC-Cyano ( Å) 6-6 6-6 6-6 6-6 6-6 6- SFC-NH ( Å) 6-6 6-6 6-6 6-6 6-6 6- SFC-SCX ( Å) 66-6 66-6 66-6 66-6 66-6 66- SFC-Pyridine (Å) 69-6 69-6 69-6 69-6 69-6 69- SFC-Diol ( Å) 66-6 66-6 66-6 66-6 66-6 66- SFC-Silica ( Å) 67-6 67-6 67-6 67-6 67-6 67- m Analytical Columns (length x ID mm) Guard column Phases.x.x.x.x.x.x * SFC-Cyano ( Å) 6-6- 6-6- 6-6- SFC-NH ( Å) 6-6- 6-6- 6-6- SFC-SCX ( Å) 66-66- 66-66- 66-66- SFC-Pyridine (Å) 69-69- 69-69- 69-69- SFC-Diol ( Å) 66-66- 66-66- 66-66- SFC-Silica ( Å) 67-67- 67-67- 67-67- m Analytical Columns (length x ID mm) Guard column Phases.6x.6x.6x.6x.6x.x * SFC-Cyano ( Å) 6-6 6-6 6-6 6-6 6-6 6- SFC-NH ( Å) 6-6 6-6 6-6 6-6 6-6 6- SFC-SCX ( Å) 66-6 66-6 66-6 66-6 66-6 66- SFC-Pyridine (Å) 69-6 69-6 69-6 69-6 69-6 69- SFC-Diol ( Å) 66-6 66-6 66-6 66-6 66-6 66- SFC-Silica ( Å) 67-6 67-6 67-6 67-6 67-6 67- m preparative and semi-preparative Columns (length x ID mm) Guard column Phases 7.8x 7.8x x x.x * SFC-Cyano ( Å) 6-78 6-78 6-6- 6- SFC-NH ( Å) 6-78 6-78 6-6- 6- SFC-SCX ( Å) 66-78 66-78 66-66- 66- SFC-Pyridine ( Å) 69-78 69-78 69-69- 69- SFC-Diol ( Å) 66-78 666-78 66-66- 66- SFC-Silica ( Å) 67-78 67-78 67-67- 67- m preparative and semi-preparative Columns (length x ID mm) Guard column Phases.x.x.x.x.x.x ** SFC-Cyano ( Å) 6-6- 6-6- 6-6- SFC-NH ( Å) 6-6- 6-6- 6-6- SFC-SCX ( Å) 66-66- 66-66- 66-66- SFC-Pyridine (Å) 69-69- 69-69- 69-69- SFC-Diol ( Å) 66-66- 66-66- 66-66- SFC-Silica ( Å) 67-67- 67-67- 67-67- www.sepax-tech.com 9-877-SEPAX-US

m preparative and semi-preparative Columns (length x ID mm) Guard column Phases x x x x x.x ** SFC-Cyano ( Å) 6-6- 6-6- 6-6- SFC-NH ( Å) 6-6- 6-6- 6-6- SFC-SCX ( Å) 66-66- 66-66- 66-66- SFC-Pyridine (Å) 69-69- 69-69- 69-69- SFC-Diol ( Å) 66-66- 66-66- 66-66- SFC-Silica ( Å) 67-67- 67-67- 67-67- m preparative and semi-preparative Columns (length x ID mm) Guard column Phases 7.8x x x x.x * SFC-Cyano ( Å) 69-78 69-69- 69-69- SFC-NH ( Å) 69-78 69-69- 69-69- SFC-SCX ( Å) 669-78 669-669- 669-669- SFC-Pyridine ( Å) 699-78 699-699- 699-699- SFC-Diol ( Å) 669-78 669-669- 669-669- SFC-Silica ( Å) 679-78 679-679- 679-679- m preparative and semi-preparative Columns (length x ID mm) Guard column Phases.x.x.x.x.x.x ** SFC-Cyano ( Å) 69-69- 69-69- 69-69- SFC-NH ( Å) 69-69- 69-69- 69-69- SFC-SCX ( Å) 669-669- 669-669- 669-669- SFC-Pyridine (Å) 699-699- 699-699- 699-699- SFC-Diol ( Å) 669-669- 669-669- 669-669- SFC-Silica ( Å) 679-679- 679-679- 679-679- m preparative and semi-preparative Columns (length x ID mm) Guard column Phases x x x x x.x ** SFC-Cyano ( Å) 69-69- 69-69- 69-69- SFC-NH ( Å) 69-69- 69-69- 69-69- SFC-SCX ( Å) 669-669- 669-669- 669-669- SFC-Pyridine (Å) 699-699- 699-699- 699-699- SFC-Diol ( Å) 669-669- 669-669- 669-669- SFC-Silica ( Å) 679-679- 679-679- 679-679- * Guard column cartridge does not include the cartridge holder ** Guard column cartridge does not include the cartridge holder * Cartridge holder ** Cartridge holder P/N# -, $./EA for x mm guard cartridge P/N# -, $./EA for x mm guard cartridge P/N# -, $7/EA for x. mm guard cartridge Cartridge Holder Cartridge www.sepax-tech.com -877-SEPAX-US