LC/MS/MS of Trichothecenes and Zearalenone in Wheat Using Different Sample Prep Methods

Similar documents
Modified QuEChERS for HILIC LC/MS/MS Analysis of Nicotine and Its Metabolites in Fish

Improved Isolation and Analysis of Mycotoxins from Cereals, Beer and Wine

Analysis of Acrylamide in French Fries using Agilent Bond Elut QuEChERS AOAC kit and LC/MS/MS

Reduced Ion Suppression and Improved LC/MS Sensitivity with Agilent Bond Elut Plexa

New SPE Sorbent for Clean-up of Fusarium Toxin-contaminated Cereals & Cereal-based Foods, Bond Elut Mycotoxin

Application Note. Author. Abstract. Introduction. Food Safety

Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

Analysis of mycotoxins in food matrices using the Agilent Ultivo Triple Quadrupole LC/MS

Mycotoxin Analysis in Peanut Butter Using Captiva EMR Lipid Cleanup and LC/MS/MS

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Neosolaniol. [Methods listed in the Feed Analysis Standards]

Mycotoxin Analysis in Infant Formula Using Captiva EMR Lipid Cleanup and LC/MS/MS

Cannabinoid Quantitation Using an Agilent 6430 LC/MS/MS

Detection, Confirmation, and Quantification of Chloramphenicol in Honey, Shrimp and Chicken Using the Agilent 6410 LC/MS Triple Quadrupole

Determination of Aflatoxins in Food by LC/MS/MS. Application. Authors. Abstract. Experimental. Introduction. Food Safety

Author. Introduction. Small Molecule Pharmaceuticals & Generics

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid

Quantitative Analysis of Opiates in Urine Using RRHT LC/MS/MS. Application. Authors. Introduction. Abstract. Forensics

Analysis of Cholesterol-Lowering Drugs (Statins) Using Dried Matrix Spot Technology

Analyze Barbiturates in Urine with Agilent 6430 LC/MS/MS and Poroshell 120 EC-C18

Fat-Soluble Vitamins Analysis on an Agilent ZORBAX Eclipse PAH Polymeric C18 Bonded Column

Author. Introduction. Abstract

Application Note. Abstract. Authors. Pharmaceutical

For Client Review Only. All Rights Reserved. Advanstar Communications Inc Scarlett Biselli, Lutz Hartig, Heiner Wegner, and Christian Hummert

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis

Validation Report 23 B

DETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS

Determination of Amantadine Residues in Chicken by LCMS-8040

Multiclass Mycotoxin Analysis in Cheese Using Agilent Captiva EMR Lipid Cleanup and LC/MS/MS

Quantitative Analysis of Underivatized Amino Acids in Plant Matrix by Hydrophilic Interaction Chromatography (HILIC) with LC/MS Detection

Authors. Abstract. Forensic Toxicology. Irina Dioumaeva, John M. Hughes Agilent Technologies, Inc.

Authors. Abstract. Introduction. Environmental

Extraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis

LC-MS/MS analysis of Chlorates in Milk and Whey Powder using the Agilent 6470 QQQ

Determination of Eight Estrogens in Milk by UHPLC and the Agilent 6495 Triple Quadrupole Mass Spectrometer

Determination of Multi-Residue Tetracyclines and their Metabolites in Milk by High Performance Liquid Chromatography - Tandem Mass Spectrometry

Agilent 6460 LC-QQQ Highly Sensitive and Robust Analysis for Lipophilic Marine Toxins in Shellfish

Application Note. Authors. Abstract. Food

Efficient Quantitative Analysis of THC and Metabolites in Human Plasma Using Agilent Captiva EMR Lipid and LC-MS/MS

Determination of Amphetamine and Derivatives in Urine

LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell 120 EC C18 Column

Extended Mass Range Triple Quadrupole for Routine Analysis of High Mass-to-charge Peptide Ions

Quantification of lovastatin in human plasma by LC/ESI/MS/MS using the Agilent 6410 Triple Quadrupole LC/MS system

LC/MS Method for Comprehensive Analysis of Plasma Lipids

Direct Analysis of Folic Acid in Digestive Juices by LC/TOF-MS Application

Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system

Determination of Sulfonamide Antibiotics in Bovine Liver Using Agilent Bond Elut QuEChERS EN Kits by LC/MS/MS

Determination of Benzodiazepines in Urine by CE-MS/MS

Determination of 44 Pesticides in Foodstuffs by LC/MS/MS Application

Rapid and Robust Detection of THC and Its Metabolites in Blood

Determination of Patulin in Apple Juice Using SPE and UHPLC-MS/MS Analysis

Accurate quantification of regulated mycotoxins by UHPLC-MS/MS and screening for 200+ mycotoxins in food and feed.

Validation Report 8. EURL for Cereals and Feeding stuff National Food Institute Technical University of Denmark

Detection and elimination strategies of matrix effects. in quantitative multi-target LC-ESI-MS/MS analysis

Accurate Quantitation of Regulated Mycotoxins by UHPLC/MS/MS

Validation Report 20

Using Software Tools to Improve the Detection of Impurities by LC/MS. Application Note. Christine Miller Agilent Technologies.

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

A FORENSIC TOXICOLOGY METHOD FOR THE DETERMINATION OF DESOMORPHINE, HEROIN, METHADONE, BUPRENORPHINE AND METABOLITES IN URINE USING LC/MS QQQ

Supporting Information

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

A RAPID AND SENSITIVE ANALYSIS METHOD OF SUDAN RED I, II, III & IV IN TOMATO SAUCE USING ULTRA PERFORMANCE LC MS/MS

Determination of Isoflavones in Soybean by LC/MS/MS

LC-MS/MS Method for the Determination of Tenofovir from Plasma

Extraction of a Comprehensive Steroid Panel from Human Serum Using ISOLUTE. SLE+ Prior to LC/MS-MS Analysis

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

Detection of Cannabinoids in Oral Fluid with the Agilent 7010 GC-MS/MS System

Quantitative Analysis of Amphetamine-Type Drugs by Extractive Benzoylation and LC/MS/MS. Application. Introduction. Authors. Abstract.

Ultrafast Analysis of Benzodiazepines in Urine by the Agilent RapidFire High-Throughput Triple Quadrupole Mass Spectrometry System

Analysis of Vitamins Using an SFC/UHPLC Hybrid System with a Triple Quadrupole LC/MS for Quantification

Identification of Steroids in Water by Ion Trap LC/MS/MS Application

Analyze Biogenic Amines in Salmon and Shrimp by Capillary Electrophoresis-Tandem MS

Two-Dimensional LC/MS/MS to Reduce Ion Suppression in the Determination of Cannabinoids in Blood Plasma

Determination of Multiple Mycotoxins in Grain Using a QuEChERS Sample Preparation Approach and LC-MS/MS Detection

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

Determination of Tetracyclines in Chicken by Solid-Phase Extraction and High-Performance Liquid Chromatography

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.

Detection of Low Level of Chloramphenicol in Milk and Honey with MIP SPE and LC-MS-MS

Development and Validation of an UPLC-MS/MS Method for Quantification of Mycotoxins in Tobacco and Smokeless Tobacco Products

Agilent 6470 Triple Quadrupole LC/MS System and EMR-Lipid. The Combination for Confident Pesticide Quantitation. Christoph Mueller

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

Dienes Derivatization MaxSpec Kit

T-2 toxin. [Methods listed in the Feed Analysis Standards]

Agilent 6410 Triple Quadrupole LC/MS. Sensitivity, Reliability, Value

Rapid Analysis of Bisphenols A, B, and E in Baby Food and Infant Formula Using ACQUITY UPLC with the Xevo TQD

Quantitation of Protein Phosphorylation Using Multiple Reaction Monitoring

Determination of Chlorophenoxyacetic Acid and Other Acidic Herbicides Using a QuEChERS Sample Preparation Approach and LC-MS/MS Analysis

Vitamin D3 and related compounds by ESI and APCI

Quantitative Determination of Drugs of Abuse in Human Plasma and Serum by LC/MS/MS Using Agilent Captiva EMR Lipid Cleanup

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

Identification of Imidacloprid Metabolites in Onions Using High Resolution Accurate Mass Spectrometry (LC/Q-TOF MS) and Accurate Mass Tools

Agilent 6490 Triple Quadrupole LC/MS System with ifunnel Technology. Ultra sensitive quantitative performance

Quantitative Method for Amphetamines, Phentermine, and Designer Stimulants Using an Agilent 6430 LC/MS/MS

LC/MS/MS of Buprenorphine and Norbuprenorphine in Whole Blood Using Agilent Bond Elut Plexa PCX and an Agilent Poroshell 120 Column

3-Acetyldeoxynivalenol. 15-Acetyldeoxynivalenol

Dr. Erin E. Chambers Waters Corporation. Presented by Dr. Diego Rodriguez Cabaleiro Waters Europe Waters Corporation 1

Fast quantitative Forensic Analysis of THC and its Metabolites in Biological Samples using Captiva EMR- Lipid and LC/MSMS

Transcription:

LC/MS/MS of Trichothecenes and Zearalenone in Wheat Using Different Sample Prep Methods Application Note Food Testing & Agriculture Authors Nick Byrd and Danielle Sweeney Campden BRI Gloucestershire UK Thomas Glauner Agilent Technologies, Inc., Waldbronn Germany Abstract A modified QuEChERS and Agilent Bond Elut Mycotoxin SPE demonstrate excellent analyte sensitivity for the detection of trichothecenes and zearalenone by LC/MS/MS. The Bond Elut mycotoxin SPE cartridge, with its greater sorbent capacity, produces cleaner extracts with slightly improved LODs and LOQs. However, the modified QuEChERS method is substantially quicker and uses much less solvent and sorbent. Both sample preparation approaches showed excellent linearity for all mycotoxins (R 2 0.995). Spiked wheat samples (50 µg/kg, n = 9) showed recoveries within 72 to 105% (CV ~ 11%) relative to immuno-affinity, a well recognized and effective form of sample clean up for mycotoxins. In this example two sample preparation procedures are used, which when combined with performance levels of the Agilent 6460 Triple Quadrupole LC/MS, can reduce the cost of analysis yet still produce data with sensitivity commensurate with regulatory control requirements.

Introduction Mycotoxins are a group of toxic secondary metabolites produced by several species of mold. Fusarium molds are of significant importance as they are particularly prevalent on cereals such as wheat, maize, barley and oats that are grown in temperate regions. Infection often leads to lower crop yield, but depending on the infecting species a range of mycotoxins called trichothecenes may be formed. There are over 150 known trichothecenes. Surveys have shown that the most predominant trichothecene is deoxynivalenol but other trichothecenes such as Nivalenol, Fusarenone-X, Neosolaniol, 3- and 15-acetyl deoxynivalenol, Diacetoxyscirpenol (DAS), T-2 toxin and HT-2 toxin can also be present. They belong to the type A and B trichothecenes and share the same basic chemical structure. Zearalenone is not a trichothecene but can also be produced by a number of Fusarium species. When ingested, trichothecenes can pose a threat to animal and human health. They can be responsible for toxic symptoms ranging from feed refusal, skin irritation, vomiting and diarrhea. These compounds are also potent inhibitors of protein and DNA synthesis and have immunosuppressant activity. EU commission regulation No 1881/2006 has set maximum limits for deoxynivalenol in a range of unprocessed and processed cereal based foods. The latter limits are lower than those set for the raw material. Compliance to these limits is determined by chemical residue analysis. Gas chromatography methods with electron capture or mass spectrometric detection have been successfully employed to determine and quantify type A and B trichothecenes following derivatization of sample extracts. More recently, methods for the simultaneous determination of type A and B trichothecenes and zearalenone by LC/MS/MS have been developed. In this application note, the performance of two sample preparation procedures to determine nine trichothecenes and zearalenone in wheat by LC/MS/MS was compared. Methods and Results Either a modified QuEChERS extraction and dispersive SPE (d-spe), or an acetonitrile/water extraction with Bond Elut Mycotoxin SPE cartridge was employed for the sample preparation procedure (Table 1). Table 1. Sample Preparation Steps for and Bond Elut Mycotoxin SPE Methods in the Analysis of Trichothecenes and Zearalenone Bond Elut Mycotoxin SPE method 5 g milled sample 25 g milled sample 1. 10 ml MeOH:ACN (85:15) 1. 100 ml H 2 O:ACN (20:80) 2. 4 g MgSO 4 + 1 g NaCl 2. Shake for 1 hour 3. Shake and centrifuge Take 2-mL aliquot Take 8-mL aliquot 1. 300 mg MgSO 4 + 100 mg PSA 1. Bond Elut Mycotoxin 2. Vortex and filter through 2. Evaporate and reconstitute 0.02-µm membrane in 1 ml H 2 O:ACN (80:20) 3. Evaporate and reconstitute in 3. Filter through 0.02-µm 1 ml H 2 O:ACN (80:20) membrane Methanol/ACN solvent was added to each tube containing the milled sample and vortexed. An Agilent Bond Elut Nonbuffered extraction packet (p/n 5982-5550) containing 4 g MgSO 4 and 1 g NaCl was then added. The tube was vigorously shaken and centrifuged. An aliquot from the upper layer was transferred to a tube containing 1:3 by weight PSA/MgSO 4. When using 2-mL aliquots, 2-mL blank tubes were prepared manually by weighing in 300 mg MgSO 4 and 100 mg PSA. In later routine work, the aliquot was reduced to 1 ml, allowing the use of Bond Elut d-spe tubes containing 150 mg MgSO 4 and 50 mg PSA (p/n 5982-5022). Bond Elut Mycotoxin SPE Method A Bond Elut Mycotoxin SPE cartridge, 500 mg, 3 ml (p/n 12102167) was used in the second sample preparation scheme. An aliquot from the extracted sample was applied to the SPE cartridge. The eluent was collected and evaporated. The SPE method is an unretained SPE (scavenger) mechanism which eliminates matrix constituents from the sample likely to interfere with the ESI-MS/MS detection. 2

Conditions HPLC Conditions Columns Instrument Flow Rate Column Temp 30 C Injection Vol 10 µl Mobile Phase Agilent ZORBAX Rapid Resolution HT Eclipse Plus C18, 2.1 100 mm, 1.8 µm (p/n 959764-902) Agilent 6460 Triple Quadrupole LC/MS, Agilent 1290 Infinity LC System 5 ml/min A: Water + % acetic acid, 5 mm ammonium acetate B: Methanol + % acetic acid, 5 mm ammonium acetate MS/MS Conditions Table 2 shows the Agilent Jetstream parameters and Table 3 shows the MS conditions. MRM transistions and conditions were optimized using the MassHunter Optimizer software. Agilent Jet Stream parameters were optimized based on the mobile phase conditions and flow rates used in the analysis. Table 2. Agilent Jet Stream Parameters ESI with Agilent Jet Stream parameters, pos/neg fast polarity switching Drying gas temperature 200 C Drying gas flow 8 L/min Nebulizer pressure 45 psi Sheath gas temperature 400 C Sheath gas flow 12 L/min Capillary voltage ± 3,000 V Nozzle voltage ± 500 V Delta EMV 500 V Resolution Unit, unit Table 3. MS Conditions for The Analysis of Trichothecenes and Zearalenone Mycotoxin Precursor ion Product ion Fragmentor Collision energy Polarity 15-acetyl-deoxynivalenol 356 321 95 5 Positive 15-acetyl-deoxynivalenol 356 137 95 8 Positive 15-acetyl-deoxynivalenol 339 137 105 12 Positive 3-acetyl-deoxynivalenol 397 337 95 4 Negative 3-acetyl-deoxynivalenol 397 59 95 20 Negative Diacetoxyscirpenol (DAS) 384 307 105 4 Positive Diacetoxyscirpenol (DAS) 384 247 105 6 Positive Deoxynivalenol (DON) 355 265 95 4 Negative Deoxynivalenol (DON) 355 59 95 20 Negative Fusarenone-X 413 263 95 8 Negative Fusarenone-X 413 59 95 28 Negative HT-2 toxin 442 263 105 4 Positive HT-2 toxin 442 215 105 4 Positive Neosolaniol 400 215 95 16 Positive Neosolaniol 400 185 95 16 Positive Nivalenol 371 311 108 4 Negative Nivalenol 371 281 108 8 Negative Nivalenol 371 59 108 24 Negative T-2 toxin 484 215 120 16 Positive T-2 toxin 484 185 120 14 Positive Zearalenone 317 175 190 16 Negative Zearalenone 317 131 190 24 Negative Zearalanone 319 275 185 16 Negative Zearalanone 319 205 185 16 Negative 3

Fast continous polarity switching was used for this method to allow the measurement of each mycotoxin in the ionization mode that allows best sensitivity. This can be done either by using static MRM with or without time segmentation or by using Dynamic MRM. When using Dynamic MRM with a retention time window of 1 minute and a cycle time of 500 ms, the maximum number of concurrent MRMs is 12, resulting in a minimum dwell time of 31.5 ms and a maximum dwell time of 246.5 ms. A cycle time of 500 ms allowed for at least 20 data points across the chromatographic peak for accurate quantitation. A chromatogram for 50 ppb of the mycotoxins spiked into wheat matrix is shown in Figure 1. x10 2 1.1 1 Nivalenol Deoxynivalenol Fusarenon-X Neosolaniol 15-acetyl deoxynivalenol 3-acetyl deoxynivalenol Diacetoxyscirpenol HT-2 Toxin T-2 Toxin Zearalenone 0.9 Relative Abundance 0.7 0.5 0.3 0.1 0 4.6 4.8 5 5.2 5.4 5.6 5.8 6 6.2 6.4 6.6 6.8 7 7.2 7.4 7.6 7.8 8 8.2 8.4 8.6 8.8 9 Acquisition Time (min) Figure 1. 50 ppb Wheat Matrix Standard : normalized chromatogram for primary transitions. Please note that this method does not require chromatographic resolution between the isomers 15-acetyl DON and 3-acetyl DON because they are distinguished through measurement under different mass spec polarities. 4

Figure 2 shows the calibration curves for three selected mycotoxins acquired for matrix matched calibration standards with corresponding chromatograms. x10 4 Responses 0.9 0.7 0.5 0.3 0.1 0.0 Deoxynivalenol y = 70.928 X + 409.733 R 2 = 0.99542 0 10 20 30 40 50 60 70 80 90 100 110 120 130 Concentration (ng/ml) A Counts x10 2 9 8 7 6 5 4 3 2 1 0 355.0 -> 59.1, 355.0 -> 265.0 6.1 6.15 6.2 6.25 6.3 6.35 6.4 6.45 6.5 6.55 6.6 Acquisition Time (min) x10 5 1.8 Responses 1.6 1.4 1.2 T-2 Toxin y = 1399.1 X + 1047.7 R 2 = 0.99945 B Counts x10 4 1.6 1.4 1.2 1 484.0 -> 215.1, 484.0 -> 185.1 1.0 0.0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 130 Concentration (ng/ml) 7.5 7.6 7.7 7.8 7.9 8 8.1 8.2 8.3 8.4 8.5 8.6 8.7 8.8 8.9 Acquisition Time (min) x10 5 Counts x10 4 2.8 384.0 -> 307.1, 384.0 -> 247.0 Responses 3.0 2.8 2.6 2.4 2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.0 Diacetoxyscirpenol y = 2444.0 X - 614.9 R 2 = 0.99995 C 2.4 2 1.6 1.2 0 0 10 20 30 40 50 60 70 80 90 100 110 120 130 Concentration (ng/ml) 7.1 7.2 7.3 7.4 7.5 7.6 7.7 7.8 7.9 8 8.1 8.2 8.3 8.4 Acquisition Time (min) Figure 2. Calibration curves, (A) Deoxynivalenol, (B) T-2 toxin, (C) Diacetoxyscirpenol, with corresponding chromatograms. 5

Excellent linearity was observed for all mycotoxins (R 2 0.995) and spiked wheat samples (50 µg/kg, n = 9) showed recoveries within 72 to 105% (CV ~ 11 %) for all compounds and both sample preparation methods (Table 4). Analyte sensitivity was excellent with both sample preparation techniques, whereas the BE Mycotoxin SPE cartridge clean-up with its greater sorbent capacity produced cleaner extracts with slightly improved LODs (S/N > 3) and LOQs (S/N >10). The LOQs in the final extract for all mycotoxins ranged from 0.003 µg/kg (diacetoxyscirpenol) to 1.04 µg/kg (nivalenol) using modified QuEChERS, and from 0.002 µg/kg (diacetoxyscirpenol) to 6 µg/kg (15-acetyl-deoxynivalenol) for the BE Mycotoxin SPE method, respectively (Table 5). Table 4. Analyte Comparison of modified QuEChERS and Cartridge SPE Recovery Data Spiked in Wheat Samples at 50 µg/kg (n=9) Analyte retention time (min) recovery (%) RSD (%) BE Mycotoxin SPE recovery (%) BE Mycotoxin SPE RSD (%) Nivalenol 5.6 73 7 93 11 Deoxynivalenol 6.4 85 8 84 11 Fusarenon-X 6.8 81 9 89 9 Neosolaniol 6.8 94 9 77 9 15-acetyl deoxynivalenol 7.2 88 9 72 10 3-acetyl deoxynivalenol 7.2 100 9 92 11 Diacetoxyscirpenol 7.7 105 2 104 3 HT-2 8.0 83 8 99 4 T-2 toxin 8.2 83 8 100 4 Zearalenone 8.4 87 8 79 9 Table 5. Trichothecene and Zearalenone Limits of Detection and Quantification in Wheat Samples Analyte LOD (µg/kg) LOQ (µg/kg) BE Mycotoxin SPE LOD (µg/kg) Nivalenol 0.31 1.04 0.07 4 Deoxynivalenol 0.04 0.12 0.04 0.12 Fusarenon-X 0.09 0.3 0.08 6 Neosolaniol 0.13 0.03 0.1 15-acetyl deoxynivalenol 6 6 3-acetyl deoxynivalenol 0.1 0.34 0.1 0.33 Diacetoxyscirpenol 0.001 0.003 0.0006 0.002 HT-2 0.05 0.17 0.03 0.1 T-2 toxin 0.01 0.04 0.006 0.02 Zearalenone 0.02 0.06 0.02 0.06 LOD = limit of detection (S/N > 3), LOQ = limit of quantification (S/N > 10) BE Mycotoxin SPE LOQ (µg/kg) 6

Conclusion Wheat samples were spiked at 50 µg/kg with nine trichothecenes and zearalenone. Ion suppression in the sample extracts was overcome by quantifying against a matrix-matched standard. Both the modified QuEChERS and the Bond Elut Mycotoxin SPE demonstrated excellent analyte sensitivity. The Bond Elut mycotoxin SPE procedure, with its greater sorbent capacity, produced cleaner extracts with slightly improved LODs and LOQs. The two sample preparation techniques gave recoveries from 72 to 105%. However, the modified QuEChERS method had several advantages. It was substantially quicker, allowing greater sample throughput, and used considerably less solvent and sorbent resulting in significantly reduced analytical costs. References 1. F. Berthiller, R. Schuhmacher, G. Buttinger, and R. Krska (2005) Simultaneous determination of type A and B trichothecenes along with zearalenone by high performance liquid chromatography tandem mass spectrometry. Mycotoxin Res., 21(4): 237-240. 2. I.Sospedra, J. Blesa, J.M. Soriano, and J. Manes, (2010) Use of the modified quick easy cheap effective rugged and safe sample preparation approach for the simultaneous analysis of type A- and B-trichothecenes in wheat flour. J. Chrom. A, 1217: 1437-1440. For More Information These data represent typical results. For more information on our products and services, visit our Web site at www.agilent.com/chem. 7

www.agilent.com/chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc., 2012 Printed in the USA February 2, 2012 5990-9107EN