Low Dose Excellent Image Quality Rapid Reconstruction
Efficient 3 in 1 Dental X-ray System CBCT > Precise 3-D Anatomical structures - Accurate diagnosis for doctors - Safe implant for patients > Significant reduction in X-ray dose Cephalometric > Best image quality for diagnosis > Least X-ray exposure for patients Lateral PA SMV Carpus Lateral PA Carpus Panoramic image > Anatomic structure > Minimum distortion and artifact TMJ
Low Dose! Excellent Image Quality! Rapid Reconstruction! 0.2 Voxel slice 16 8cm Rapid Reconstruction 60 Rapid Visualization When running into the same Voxel sizes 30 21 FOV 16 8cm: 10 Sec FOV 16 14.5cm: 30 Sec A B HDXWILL Computation times of reconstruction are significantly reduced by the latest GPU technology. It takes much less than competitors. 0.2 Voxel slice 16 14.5cm stitch
Feature Outstanding Auto-Focusing Misaligned result Autofocusing correction UFS(Ultra Fast Scan technology) 8 Sec Stitching: 16 Sec 24 Sec Stitching: 36 Sec Ultra fast scan Normal scan Remarkable MAR(Metal Artifact Reduction) algorithm Without MAR With MAR
Clinical Application Diagnosis of TMJ disorder Bilateral TMJ in a single exposure by wide FOV Normal TMJ image Abnormal TMJ image Accurate diagnosis of abnormal TMJ by one shooting. DENTRI CT images of 16cm that can check both condyle at once Location and angle diagnosis of bilateral mandibular condyle erosion Accurate 3D volume rendering image Diagnosis of TMJ ankylosis & mandibular fossa
Clinical Application Implant diagnosis and shape check-up of anatomical structure Maximum utilization of three-dimensional measured value of residual bone by one to one actual measurement. Distance and angle measurement of mental nerve for implant fixation Planning of implant size and ideal position Maxillary sinus septum
Clinical Application before surgery. Simultaneous checking of the location of posterior superior alveolar artery and inferior alveolar nerve by one shot. Acquire the upper and lower jaw structure. Maxillary sinus septum Incisive nerve Mental foramen Inferior alveolar nerve pathway Integrated prosthetic designs and implant planning
Clinical Application Diagnosis of periodontal pocket and impacted teeth. Accurate diagnosis of bilateral impacted third molar teeth with just one scanning. Location of horizontally impacted both third molar teeth Periapical lesion Recognition of relation among buccolingual location of horizontally impacted the third molar tooth, root, and mandibular canal
Clinical Application Diagnosis of maxillary sinus and sinusitis. Hypertrophic Mucous Cyst check by high resolution image which is not shown on general radiograph. Mucous cyst Sinus Implant Surgery Sinusitis Sinus mucocele Chronic sinusitis spread to orbit
Clinical Application Endodontic treatment Clear check on irregular root canal by precise 0.1 VOXEL SIZE. C Shape canal Root canal wall 0.1 Voxel 0.5mm slice 3D Endoscopy view Clinical Application Measurements of airway Useful to evaluation on nasal airway and nasopharyngeal airway.
Clinical Application Orthodontic treatment Easy measurement of facial asymmetry by wide FOV 16 14.5cm which is necessary to cover the midsagittal plane. Location of impacted teeth check Bone thickness measurement for miniscrew insertion Maxillary asymmetry measurement Mandibular asymmetry measurement 3D Cephalometric image without distortion Asymmetric analysis
Software Will-Master OnDemand 3D Patient image management software and 2D viewer 3D viewer WillCeph Cephalometric analysis Software(Optional) Dental unit & chair Intra Oral X-ray With Sensor System Star-X Intra Oral X-ray Other equipment Wireless Portable X-ray Convenient to Use! Excellent Image Quality! Easy Operation! Reduced Radiation Dose High quality Image Ergonomic Design Reduced Radiation Dose Easy & Safe operation
PRODUCT DIMENSIONS DENTRI > Pano/ CBCT Non-stitch Mode stitch Mode DENTRI-C > Pano/ CBCT/ One-shot Ceph Non-stitch Mode stitch Mode DENTRI-S > Pano/ CBCT/ Scan Ceph Non-stitch Mode stitch Mode
SPECIFICATIONS MODEL PANORAMA CEPHALO FOV CT ONE-SHOT SCAN 16 14.5 FREE FOV 16 8 DENTRI Stitch Mode Non-stitch Mode DENTRI-C Stitch Mode Non-stitch Mode DENTRI-S Stitch Mode Non-stitch Mode X-ray beam Cone beam Patient Position Standing Tube Voltage 60 kv-110 kv Patient Alignment Focal Spot 0.5mm Control Device Vertical Column: electric motion(optional) Column: electric motion Temple Support: motion Alignment: Touch panel Exposure & Image acquisition: PC Voxel size(ct) 0.10, 0.15, 0.20, 0.25, 0.30 Detector Type CT & Panorama CMOS or asi Demensions (W D H) One shot type Cephalo Direct(a-Se, TFT) Install Standing DENTRI: 1201 mm 1361 mm 2455 mm DENTRI-C(Moving type): 2006 mm 1361 mm 2455 mm DENTRI-C(Fix type): 1999 mm 1361 mm 2455 mm DENTRI-S: 1941 mm 1361 mm 2455 mm (tolerance: ±5%) Scan type Cephalo TDI CCD CT & Panorama 14 bits or 16 bits Gray Scale One shot type Cephalo Scan type Cephalo 14 bits 16 bits System Weight (tolerance: ±10%) DENTRI: 243 kg DENTRI-C: 270 kg DENTRI-S: 260 kg CT(Pulsed) 8 s, 16 s, 24 s, 36 s Panorama 14 s and less Scan Time One shot type Cephalo 0.5 s, 1.0 s, 1.5 s, 2.0 s Field of View(CT) (cm cm) (Diam. Height) Max. 16 14.5(Stitch) 16 8 Free FOV Scan type Cephalo 8.2 s and less OS Window 7 64 bit Reconstruction Time (With MAR) less than 40 s Memory 16 G Specifications are subject to change without notice for improvement of product performance. Sales Office Taehwa Bldg, 29, Insa-dong 5-gil, Jongno-gu, Seoul, Korea Tel.82-1544-5735 / Fax. 82-2-2003-8497 www.hdx.co.kr R&D Center 14F, KCC Weltz Valley, 205, Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea www.hdx-will.com Manufacturing Facility #105, 201, 202, 203, 204, 38, Osongsaengmyeong4-ro, Osong-eup, Heungdeok-gu, Cheongju-si, Chungcheongbuk-do, Korea Tel. 82-43-710-7318 / Fax. 82-43-710-7312 CNDE03