Abstract. Introduction

Similar documents
A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column

LC/MS/MS Analysis of Metabolites of Synthetic Cannabinoids JWH-018 and JWH-073 in Urine

Raptor HILIC-Si: Simplify the Switch to HILIC

The Raptor HILIC-Si Column

Biphenyl. Stationary Phase: Fast, Rugged Raptor Columns with Time-Tested Selectivity. Pure Chromatography. Selectivity Accelerated

Raptor HILIC-Si: Simplify the Switch to HILIC

High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine

ARC-18. Stationary Phase: Ahead of the Curve for Large, Multiclass Lists by Mass Spec. Pure Chromatography. Selectivity Accelerated.

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

UPLC-MS/MS Analysis of Azole Antifungals in Serum for Clinical Research

A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS

Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

Roc On with These Dependable LC Columns

Maria João Mendes Mendonça Barreira Department of Health Promotion and Chronic Deseases, INSA

Simultaneous Quantitative Analysis of Total Catecholamines and Metanephrines in Urine Using 500 MG CLEAN UP CCX2 and LC-MS/MS

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis

Reducing Sample Volume and Increasing Sensitivity for the Quantification of Human Insulin and 5 Analogs in Human Plasma Using ionkey/ms

Ultra Columns HPLC COLUMNS

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

Ultra Columns. also available. ordering note

Direct Analysis of Urinary Opioids and Metabolites by Mixed-Mode µelution SPE Combined with UPLC/MS/MS for Forensic Toxicology

Extraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis

Rapid, Simple Impurity Characterization with the Xevo TQ Mass Spectrometer

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

Vitamin D3 and related compounds by ESI and APCI

[ APPLICATION NOTE ] High Sensitivity Intact Monoclonal Antibody (mab) HRMS Quantification APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis

Simultaneous Quantitative Analysis of Total Catecholamines and Metanephrines in Urine Using CLEAN UP CCX2 and LC-MS/MS

Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ

Fully Automated Online Sample Preparation AND Quantification of Amiodarone from Whole Blood using CLAM-LC-MS/MS

Determination of Amantadine Residues in Chicken by LCMS-8040

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

DETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

LCMS-8030 Application Report. Steroids: Testosterone, Progesterone, Estradiol, Ethinylestradiol

A RAPID AND SENSITIVE ANALYSIS METHOD OF SUDAN RED I, II, III & IV IN TOMATO SAUCE USING ULTRA PERFORMANCE LC MS/MS

LC-MS/MS Method for the Determination of Tenofovir from Plasma

Dr. Erin E. Chambers Waters Corporation. Presented by Dr. Diego Rodriguez Cabaleiro Waters Europe Waters Corporation 1

Rapid Hydrolysis of Benzodiazepines in Urine. Alicia Zook 1 and Crystal Xander B.S. 2. Cedar Crest College, Allentown, PA 1

Integration of steroids analysis in serum using LC-MS/MS with full-automated sample preparation

Fully automated sensitive determination of immunosuppressant drugs in whole blood, using high quality internal standardization

Ultrafast Analysis of Benzodiazepines in Urine by the Agilent RapidFire High-Throughput Triple Quadrupole Mass Spectrometry System

Application Note LCMS-108 Quantitation of benzodiazepines and Z-drugs in serum with the EVOQ TM LC triple quadrupole mass spectrometer

Tentu Nageswara Rao et al. / Int. Res J Pharm. App Sci., 2012; 2(4): 35-40

Development and Validation of an UPLC-MS/MS Method for Quantification of Mycotoxins in Tobacco and Smokeless Tobacco Products

A FORENSIC TOXICOLOGY METHOD FOR THE DETERMINATION OF DESOMORPHINE, HEROIN, METHADONE, BUPRENORPHINE AND METABOLITES IN URINE USING LC/MS QQQ

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

Dry eye disease commonly known as atopic keratoconjunctivitis is an autoimmune disease of

Method Development for the Analysis of Endogenous Steroids Using Convergence Chromatography with Mass Spectrometric Detection

Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS

A New Stability-Indicating and Validated RP-HPLC Method for the Estimation of Liraglutide in Bulk and Pharmaceutical Dosage Forms

Development of a Bioanalytical Method for Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid

Estimation of zolmitriptan by a new RP-HPLC method

Analysis of Limonin in Citrus Juice Using QuEChERS and LC-MS/MS

APPLICATIONS TN Analytical Method

A High Sensitivity UPLC/MS/MS Method for the Analysis of Clopidogrel and Clopidogrel Carboxylic Acid Metabolite in Human K 2 EDTA Plasma

PHOTOCATALYTIC DECONTAMINATION OF CHLORANTRANILIPROLE RESIDUES IN WATER USING ZnO NANOPARTICLES. DR. A. RAMESH, Ph.D, D.Sc.,

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

Application Note. Author. Abstract. Introduction. Food Safety

Determination of Benzodiazepines in Urine by CE-MS/MS

LC Columns and Accessories

SUPPORTING INFORMATION FOR: CONCENTRATIONS OF POLYBROMINATED DIPHENYL ETHERS, HEXABROMOCYCLODODECANES AND TETRABROMOBISPHENOL-A IN BREAST MILK FROM

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1.

Journal of Chemical and Pharmaceutical Research

Title: Pharmacokinetics of daikenchuto, a traditional Japanese medicine (Kampo) after. single oral administration to healthy Japanese volunteers

Comparison of Biotage Extrahera vs. Manual Sample Processing Using a Vacuum Manifold

Development and Validation of a Polysorbate 20 Assay in a Therapeutic Antibody Formulation by RP-HPLC and Charged Aerosol Detector (CAD)

Analytical Method for 2, 4, 5-T (Targeted to Agricultural, Animal and Fishery Products)

Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System

Analysis of Cannabinoids in Cannabis by UHPLC Using PDA Detection

Simultaneous Analysis of Intact Human Insulin and Five Analogs in Human Plasma Using μelution SPE and a CORTECS UPLC Column

A Novel Platform of On-line Sample Pre-treatment and LC/MS/MS Analysis for Screening and Quantitation of Illicit Drugs in Urine

Comprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids

Overview. Introduction. Experimental. Cliquid Software for Routine LC/MS/MS Analysis

ACQUITY UPLC WITH PDA DETECTION: DETERMINING THE SENSITIVITY LIMITS OF OXYBUTYNIN AND RELATED COMPOUNDS

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Development and Validation of RP-HPLC Method for the Estimation of Gemigliptin

Pelagia Research Library

HVA, VMA and 5-HIAA in Urine

Research and Reviews: Journal of Pharmaceutical Analysis

Sanjog Ramdharane 1, Dr. Vinay Gaitonde 2

Simultaneous Determination of Prescription and Designer Benzodiazepines in Urine and Blood by SPE and LC-MS/MS

Neosolaniol. [Methods listed in the Feed Analysis Standards]

LC/MS Analysis of Various Hydrophilic Compounds Using a Polymer-Based Amino Column - Shodex TM HILICpak TM VG-50 2D

SWATH Acquisition Enables the Ultra-Fast and Accurate Determination of Novel Synthetic Opioids

Comparison of a UPLC Method across Multiple UHPLC Systems

Restek PAL SPME Fibers cat.#

Highly Reproducible Detailed cis/trans FAMEs Analysis Ensured by New Optimized Rt-2560 Column Manufacturing and Application-Specific QC Test

Workflow for Screening and Quantification of the SAMHSA (NIDA) Panel in Urine Using UHPLC-TOF

CHAPTER 2 SIMULTANEOUS DETRMINATION OF ANASTROZOLE AND TEMOZOLOMIDE TEMOZOLOMIDE CAPSULES 20 MG AND ANASTROZOLE TABLETS 1 MG

Development of a High Sensitivity SPE-LC-MS/MS Assay for the Quantification of Glucagon in Human Plasma Using the ionkey/ms System

Quantitation by High Resolution Mass Spectrometry: Case Study of TOF MS for the Quantitation of Allopurinol from Human Plasma

Application Note. Abstract. Authors. Pharmaceutical

Transcription:

A Fast Dilute-And-Shoot Method for Simultaneous 5-Hydroxyindoleacetic Acid (5-HIAA), Vanillylmandelic Acid (VMA), and Homovanillic Acid (HVA) LC-MS/MS Analysis in Human Urine By Shun-Hsin Liang and Sue Steinike Abstract In this partial validation study, we demonstrated the performance of a fast dilute-and-shoot LC-MS/MS method using a Raptor Biphenyl column for the simultaneous analysis of 5-hydroxyindoleacetic acid (5-HIAA), vanillylmandelic acid (VMA), and homovanillic acid (HVA) in human urine. Excellent results were obtained for linearity, accuracy, and precision. With this method, these serotonin and catecholamine metabolites can be measured in human urine with a 5-minute total analysis time. The analytical method is applicable to clinical labs that require a combination of fast analysis times and low-cost sample preparation procedures for 5-HIAA, VMA, and HVA using LC-MS/MS analysis. Introduction 5-Hydroxyindoleacetic acid (5-HIAA), vanillylmandelic acid (VMA), and homovanillic acid (HVA) are Figure 1: Structures of VMA, HVA, and 5-HIAA the final metabolites of serotonin, epinephrine, and dopamine, respectively (Figure 1). Measurement of these metabolites in urine is used for the diagnosis of carcinoid and neuroendocrine tumors including neuroblastoma, pheochromocytoma, and paraganglioma. Several commercial products are available for the simultaneous measurement of these three analytes in urine. However, these commercial kits all require extensive sample preparation and chromatographic analysis times of up to 16 minutes. The development of a faster and simpler method would greatly reduce the time and cost of this type of clinical test. In this study, we developed a fast dilute-and-shoot method for accurate and specific 5-HIAA, VMA, and HVA LC-MS/MS analysis in urine using a Raptor Biphenyl column. The Raptor Biphenyl column was selected for this work because our initial investigation determined that it offers better peak shape and sensitivity than a C18 column.

Experimental To evaluate linearity, eight standard solutions (0.2, 0.4, 1.0, 5.0, 10, 25, 50, and 100 µg/ml) were prepared in synthetic human urine (Surine negative urine control, Cerilliant). In addition, two levels of urine control samples (Bio-Rad Lyphochek quantitative urine control, bilevel minipak #75X) were used as QC samples for accuracy and precision analysis. Controls 1 and 2 were described by Bio-Rad Laboratories as normal and abnormal levels, respectively, and had labeled concentration ranges (Table II) for 5-HIAA, VMA, and HVA that were determined by Bio-Rad using a reversed-phase HPLC method. All prepared standards and samples were diluted 10x by mixing 40 µl of prepared standard or sample in urine with 60 µl of water and 10 µl of internal standard solution (. µg/ml of 5-HIAA-D5, VMA-D, and HVA-D5 in methanol) in a 0.45 µm Thomson SINGLE StEP PVDF filter vial (Restek, cat.# 25896). Standards and samples were filtered and injected for analysis. 5-HIAA, VMA, and HVA LC analysis was performed on a Shimadzu Nexera XR System coupled with a Sciex API 4000 mass spectrometer. conditions were as follows and analyte transitions are provided in Table I. Analytical column: Raptor Biphenyl (5 µm, 100 mm x 2.1 mm; cat.# 909512) Guard column: Raptor Biphenyl EXP guard column cartridge (5 µm, 5 mm x 2.1 mm; cat.# 90950252) and EXP direct connect holder (cat# 25808) Mobile phase A: 0.1% Formic acid + 5 mm ammonium formate in water Mobile phase B: Methanol Gradient Time (min) %B 0.00 15.00 80.01 15 5.00 15 Flow rate: 0.5 ml/min Injection volume: 5 µl Column temp.: 0 C Ion mode: Negative ESI Table I: Analyte Transitions Analyte CAS # Precursor Ion Product Ion Qualifier Product Ion Qualifier 5-HIAA-D5 195.1 148.0 5-HIAA 54-16-0 190.0 145.9 144.0 VMA-D 200.1 19.9 VMA 55-10-7 197.0 17.9 16.9 HVA-D5 186.1 127.0 HVA 06-08-1 181.0 121.9 16.9 Results and Discussion To develop a quantitative dilute-and-shoot method, it is important to ensure chromatographic separation of all matrix interferences from the target analytes. Upon initial method development, it was observed that the response of HVA internal standard suffered from urine matrix suppression and resulted in inaccurate measurement of HVA concentration. To solve this problem, it was necessary to modify the additive type in the mobile phase and select an LC column with the proper phase chemistry. The final method demonstrated that the Raptor Biphenyl column is unique in that it offered excellent chromatographic performance for simultaneous accurate and precise quantification of 5-HIAA, VMA, and HVA in diluted human urine samples (see Figure, 4, and 5 for representative chromatograms). Linear responses were obtained from 0.2 100 µg/ml for 5-HIAA, VMA, and HVA. A 1/x weighted quadratic regression provided the best fit for the standard calibration curves of all three analytes. The deviations were all 10% (except for the lowest concentration, which was 15%) and the R 2 values all were 0.999 1.000 (see examples in Figure 2). As estimated from the signal-to-noise value of the 0.2 µg/ml standard injection, the LODs were 0.0, 0.007, and 0.02 µg/ml for 5-HIAA, VMA, and HVA, respectively. www.restek.com 2

Figure 2: Calibration Curves for 5-HIAA, VMA, and HVA LC Analyses VMA y = -0.00028 x 2 + 0.178 x + 0.0114 (r = 0.9999) 5-HIAA y = -0.00106 x 2 + 0.417 x + 0.022 (r = 0.9999) HVA y = -.25e-005 x 2 + 0.092 x + 0.000782 (r = 0.9999) www.restek.com

Three sets of samples were prepared and analyzed to evaluate method accuracy and precision. Method accuracy was demonstrated to be acceptable as the quantitative concentrations fell within the nominal concentration ranges for both the low and high urine control samples (Table II). The %RSD ranged from 0.2 2.8% and 0.2 2.9% for intraday and interday, respectively (data not shown), indicating acceptable method precision. Table II: Accuracy and Precision of Urine Control Samples QC Level 1 (n = ) QC Level 2 (n = ) Analyte Range (µg/ml)* Average Conc. (µg/ml) %RSD Range (µg/ml)* Average Conc. (µg/ml) %RSD 5-HIAA 2.69 4.49.59 2.2 21.6 2.7 27.5 1.7 VMA 2.12.90.4 1.0 10.9 18.2 16. 0.2 HVA 1. 2.46 1.95 2.4 12.9 18.9 17.5 2.9 *The QC sample concentration ranges were supplied by the vendor. Conclusion Commercial kits for the analysis of 5-hydroxyindoleacetic acid (5-HIAA), vanillylmandelic acid (VMA), and homovanillic acid (HVA), require extensive sample preparation and chromatographic analysis times up to 16 minutes. In contrast, using Restek s dilute-and-shoot method and a Raptor Biphenyl column, these serotonin and catecholamine metabolites can be measured in a quick 5-minute analysis. This method is applicable to clinical 5-HIAA, VMA, and HVA LC-MS/MS analysis in urine and provides the benefits of both fast analysis times and low-cost sample preparation procedures. Figure : 5-HIAA, VMA, and HVA LC Analysis in Fortified Synthetic Human Urine Conc. Peaks t R (min) (µg/ml) Precursor Ion Product Ion 1. 4-Hydroxy--methoxymandelic acid-d (VMA-D) 0.90 0.8 200.1 19.9 2. Vanillylmandelic acid (VMA) 0.92 1 197.0 17.9. 5-Hydroxyindole-4,6,7-D--acetic-D2 acid (5-HIAA-D5) 1.80 0.8 195.1 148.0 4. 5-Hydroxyindole--acetic acid (5-HIAA) 1.82 1 190.0 145.9 5. 4-Hydroxy--methoxyphenyl-D-acetic-D2 acid (HVA-D5) 2.10 0.8 186.1 127.0 6. Homovanillic acid (HVA) 2.12 1 181.0 121.9 1 2 4 Column Raptor Biphenyl (cat.# 909512) Dimensions: 100 mm x 2.1 mm ID Particle Size: 5 µm Guard Column: Raptor Biphenyl guard column cartridge 5 mm, 2.1 mm ID, 5 µm (cat.# 90950252) Temp.: 0 C Sample Diluent: Water Inj. Vol.: 5 µl Mobile Phase A: 0.1% Formic acid, 5 mm ammonium formate in water B: Methanol Detector Ion Notes Time (min) Flow (ml/min) %A %B 0.00 0.5 85 15.00 0.5 20 80.01 0.5 85 15 5.00 0.5 85 15 MS/MS ESI- The synthetic urine (Surine) was fortified with VMA, HVA, and 5-HIAA to a concentration of 10 μg/ml. A 40 μl aliquot of fortified urine was mixed with 60 μl of water and 10 μl of internal standard solution (. μg/ml in methanol) in a Thomson 0.45 μm PVDF filter vial and injected for analysis after filtration. 5 6 0.0 0.5 1.0 1.5 2.0 2.5.0 Time (min) LC_CF0660.5 4.0 4.5 5.0 www.restek.com 4

Figure 4: 5-HIAA, VMA, and HVA LC Analysis in Human Urine (Control Level 1) 4 1 2 5 6 0.0 0.5 1.0 1.5 2.0 2.5.0 Time (min) LC_CF0661.5 4.0 4.5 5.0 Conc. Peaks t R (min) (µg/ml) Precursor Ion Product Ion 1. 4-Hydroxy--methoxymandelic acid-d (VMA-D) 0.90 0.8 200.1 19.9 2. Vanillylmandelic acid (VMA) 0.92 2.12.90* 197.0 17.9. 5-Hydroxyindole-4,6,7-D--acetic-D2 acid (5-HIAA-D5) 1.80 0.8 195.1 148.0 4. 5-Hydroxyindole--acetic acid (5-HIAA) 1.82 2.69 4.49* 190.0 145.9 5. 4-Hydroxy--methoxyphenyl-D-acetic-D2 acid (HVA-D5) 2.10 0.8 186.1 127.0 6. Homovanillic acid (HVA) 2.12 1. 2.46* 181.0 121.9 *These concentration ranges were supplied by the vendor (see notes). Column Raptor Biphenyl (cat.# 909512) Dimensions: 100 mm x 2.1 mm ID Particle Size: 5 µm Pore Size: 90 Å Guard Column: Raptor Biphenyl guard column cartridge 5 mm, 2.1 mm ID, 5 µm (cat.# 90950252) Temp.: 0 C Sample Diluent: Water Inj. Vol.: 5 µl Mobile Phase A: 0.1% Formic acid, 5 mm ammonium formate in water B: Methanol Detector Ion Notes Time (min) Flow (ml/min) %A %B 0.00 0.5 85 15.00 0.5 20 80.01 0.5 85 15 5.00 0.5 85 15 MS/MS ESI- The human urine sample is the Bio-Rad Lyphochek quantitative urine control, level 1. A 40 μl aliquot of urine was mixed with 60 μl of water and 10 μl of internal standard solution (. μg/ml in methanol) in a Thomson 0.45 μm PVDF filter vial and injected for analysis after filtration. 5 www.restek.com

Figure 5: 5-HIAA, VMA, and HVA LC Analysis in Human Urine (Control Level 2) 4 2 1 5 6 0.0 0.5 1.0 1.5 2.0 2.5.0 Time (min) LC_CF0662.5 4.0 4.5 5.0 Conc. Peaks t R (min) (µg/ml) Precursor Ion Product Ion 1. 4-Hydroxy--methoxymandelic acid-d (VMA-D) 0.90 0.8 200.1 19.9 2. Vanillylmandelic acid (VMA) 0.91 10.9 18.2* 197.0 17.9. 5-Hydroxyindole-4,6,7-D--acetic-D2 acid (5-HIAA-D5) 1.81 0.8 195.1 148.0 4. 5-Hydroxyindole--acetic acid (5-HIAA) 1.8 21.6 2.7* 190.0 145.9 5. 4-Hydroxy--methoxyphenyl-D-acetic-D2 acid (HVA-D5) 2.11 0.8 186.1 127.0 6. Homovanillic acid (HVA) 2.14 12.9 18.9* 181.0 121.9 *These concentration ranges were supplied by the vendor (see notes). Column Raptor Biphenyl (cat.# 909512) Dimensions: 100 mm x 2.1 mm ID Particle Size: 5 µm Pore Size: 90 Å Guard Column: Raptor Biphenyl guard column cartridge 5 mm, 2.1 mm ID, 5 µm (cat.# 90950252) Temp.: 0 C Sample Diluent: Water Inj. Vol.: 5 µl Mobile Phase A: 0.1% Formic acid, 5 mm ammonium formate in water B: Methanol Detector Ion Notes Time (min) Flow (ml/min) %A %B 0.00 0.5 85 15.00 0.5 20 80.01 0.5 85 15 5.00 0.5 85 15 MS/MS ESI- The human urine sample is the Bio-Rad Lyphochek quantitative urine control, level 2. A 40 μl aliquot of urine was mixed with 60 μl of water and 10 μl of internal standard solution (. μg/ml in methanol) in a Thomson 0.45 μm PVDF filter vial and injected for analysis after filtration. Questions about this or any other Restek product? Contact us or your local Restek representative (www.restek.com/contact-us). Restek patents and trademarks are the property of Restek Corporation. (See www.restek.com/patents-trademarks for full list.) Other trademarks in Restek literature or on its website are the property of their respective owners. Restek registered trademarks are registered in the U.S. and may also be registered in other countries. 2016 Restek Corporation. All rights reserved. Printed in the U.S.A. www.restek.com Lit. Cat.# CFAN2465-UNV