LeadCare BLOOD LEAD ANALYZER. Quick Reference Guide

Similar documents
CoaguChek S System. Quick Reference Guide. This is a CLIA-waived System. Coagulation Testing with Fresh Whole Blood

Precision Xtra Training

Tips for Training New Customers

Blood Glucose Monitoring System. User Guide

Step-by-Step Instructions For OraQuick HCV Rapid Antibody Test

QUICK REFERENCE INSTRUCTIONS. THYROCHEK TSH Cassette

PROCEDURE. TITLE: Bedside Glucose Monitoring PC Laboratory. Issuing Department: Clinical Director Signature: Departments Involved:

MARSHALLTOWN MEDICAL & SURGICAL CENTER Marshalltown, Iowa

Dear HighQ Check System Owner :

To provide you with necessary knowledge and skills to accurately perform 3 HIV rapid tests and to determine HIV status.

ISO IVD 13485: : :2015

Items in the package:

Blood Glucose Monitoring System. Owner s Booklet

Blood Glucose & Ketone Monitoring System

Unigold Recombigen HIV 1/2 Training for HIV Testing Sites. Updated: February 2018 Cicely Richard Office of HIV/AIDS

CentriVet GK Blood Glucose & Ketone Monitoring System

Glucose Meter. User Guide. Veterinary Monitoring System. For dog and cat use only

Fraser Health Authority Accu-chek Inform II: Training Script

User Guide For in vitro Diagnostic Use in Animals Featuring the AlphaTRAK 2 Meter

ANTIBODY SCREENING by Uni-Gold Recombigen HIV

Management of Central Venous Access Devices. Blood Glucose Monitoring

DETERMINE SPECIMEN REQUIREMENTS HIV-1/2 Ag/Ab Combo TESTING PROCEDURE

Blood Glucose Monitoring System 12:24 PM 10/13/12. mg/dl. Before Meal. See Options. Uses only Contour Next blood glucose test strips USER GUIDE

PROCEDURE NO. POC LBH. Printed copies are for reference only. Please refer to the electronic copy for the latest version.

Blood Glucose Monitoring System

2. Before Testing Monitor Checker Test...10 Inserting Lancets into Lancing Device...11 Quality Control Testing...13

Rotavirus Test Kit. Instructions For Use. Format: Cassette Specimen: Fecal Extract Catalog Number: VEL-001-ROTA

Abbott PXP Glucose Meters Resource: Lin Gustafson, MT(ASCP) Point of Care Coordinator, Laboratory

How to Use ENBREL : Vial Adapter Method

HumaPen LUXURA HD INSULIN DELIVERY DEVICE INSTRUCTIONS FOR USE

Control D. User Manual. Blood Glucose Monitor. Subscribe on MYCONTROL.life HAIDEN

Accu-Chek Inform II: Point of Care Glucose Testing. Sharp Healthcare 2014

Point of Care testing refers to all laboratory testing that is done outside of the walls of the clinical laboratory in the proximity of the patient.

Point of Care Testing. Bedside Glucose Meter

GM700S USER S MANUAL. Blood Glucose Monitoring System

Instructions for Use. Welcome!

Instructions for Use Enbrel (en-brel) (etanercept) for injection, for subcutaneous use Multiple-dose Vial

This is a CLIA-waived system. Policies and Procedures Manual

Point of Care (POC) Glucose Testing Revised on: December, 2018 Reference: Policy LAB 23-A; Point of Care Nova Stat Strip Glucose Meter

Procine sphingomyelin ELISA Kit

MARSHALLTOWN MEDICAL & SURGICAL CENTER Marshalltown, Iowa

User manual for healthcare professionals

Protn-Latex. For Determination of Protein in Latex. (Cat. # Latex, Latex) think proteins! think G-Biosciences

Blood Glucose Monitoring System. Owner's Booklet. Instructions for Use

User Manual Important: First read the Medication Guide that comes inside your FORTEO carton.

ALPROLIX Coagulation Factor IX (Recombinant), Fc Fusion Protein INSTRUCTIONS FOR USE Do not Do not YOUR KIT CONTAINS:

BRS GM100 Glucose Monitoring System. User Instruction Manual Ver. 3.5

Instructions for Use HEMLIBRA (hem-lee-bruh) (emicizumab-kxwh) injection, for subcutaneous use

Blood Glucose Measurement. Omnitest 5 & Omnican Lance FAQ Frequently Asked Questions

Instructions for Use. For use with. 10 mg vial

User s Manual. Blood Glucose Meter

Worksheet. Worksheet. Worksheet. Worksheet. Student Performance Guide. Student Performance Guide

CoaguChek XS Plus System Whole Blood Protime/INR

For use only with Lilly 3 ml insulin cartridges (100 units/ml). Do not use other brands of insulin cartridges.

For use only with Lilly 3 ml insulin cartridges (100 units/ml). Do not use other brands of insulin cartridges.

Title: Abbott Optium Xceed Glucose Meter Effective date: 16/05/2011. Summary of Significant Changes at this Revision. SOP updated.

QUICK REFERENCE INSTRUCTIONS

PLUS One. Blood Glucose Monitoring System. Owner s Manual

Hepatitis C Virus (HCV) Antibody Test

HumaPen SAVVIO INSULIN DELIVERY DEVICE INSTRUCTIONS FOR USE

Seven Simple Steps to Start. Your Dexcom G4 PLATINUM System

VOICE. Blood Glucose Monitoring System. Owner s Manual

GlucCell TM SYSTEM USER S GUIDE Ver 2.1 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System

User s Manual Blood Glucose Meter

Table of Contents Section 1 Introduction... 1 Section 2 System Components... 4 Section 4 Initial Setup... 9 Section 5 Meter Setup and Options...

Blood Glucose Monitoring System. mmol/l 5.2. Before Meal. See Options. Uses only CONTOUR NEXT blood glucose test strips from Bayer USER GUIDE

5.2mmol/L. 5.2 mmol USER GUIDE. Uses only CONTOUR NEXT blood glucose test strips from Bayer. Wireless Blood Glucose Monitoring System

Blood Glucose Monitoring System. Owner's Booklet. Instructions for Use

PRIMA. Blood Glucose Monitoring System. Owner s Manual

5.2 mmol USER GUIDE. 5.2 mmol/l. Bolus Reminder Notes. 12:00 PM l 10/13. Uses only Contour Next blood glucose test strips.

GlucCell TM SYSTEM USER S GUIDE ver 2.3 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System

Human Influenza A (Swine Flu) Rapid test

Blood Glucose Monitoring System. Owner's Booklet. Instructions for use.

Lilly. Disposable Insulin Delivery Device User Manual

Toxicology Blood Lead Comprehensive Testing

Malaria Pf/pan antigen Rapid Test

Logic. Owner s Guide. Blood Glucose Monitor

Sharps Container (not included) 1 Gather and check supplies. Gather supplies

Blood Glucose Monitoring System

Specimen Collection Policies

QUICK REFERENCE INSTRUCTIONS For use with Sofia and Sofia 2. Rx only

Before you use the TALTZ autoinjector, read and carefully follow all the step-by-step instructions.

Blood Glucose Monitoring System. Owner's Booklet. Instructions for Use

Table of Contents. Section 1 Introduction... 1 Section 2 Getting Started... 2 Section 3 Components... 5

PRO-V IDS Kit. Bisco. Instructions for Use. Provisional Restorative System

Instructions For Use PRALUENT (PRAHL-u-ent) (alirocumab) Injection, for Subcutaneous Injection Single-Dose Pre-Filled Syringe (75 mg/ml)

Blood Glucose Monitoring System. Owner's Booklet. Instructions for use

QUICK REFERENCE INSTRUCTIONS For use with Sofia only.

HBeAg and HBeAg Ab ELISA Kit

GM700 USER S MANUAL. Blood Glucose Monitoring System GM700

FLASH GLUCOSE MONITORING SYSTEM. User s Manual

120 mg USER GUIDE. 120 mg/dl. Bolus Reminder Notes. Uses only CONTOUR NEXT Blood Glucose Test Strips. 12:24 PM l 10/13.

Blood Glucose Monitoring System. Owner's Booklet. Instructions for Use

Instructions for Use Neulasta (nu-las-tah) (pegfilgrastim) Injection, for subcutaneous use Single-Dose Prefilled Syringe. Plunger rod Used plunger rod

NovoPen Echo User guide

For use only with INSTRUCTIONS FOR USE

Blood Glucose Monitoring System USER GUIDE. Replaces Owner s Booklet. AW A Rev. date: 11/2017 AW A

Polymer Technology Systems, Inc. CardioChek PA Comparison Study

Good to know. Tips and tricks for accurate blood glucose monitoring

For Self-Testing Use Portable Whole Blood Test System. User Guide

Transcription:

LeadCare II BLOOD LEAD ANALYZER Quick Reference Guide

Precautions Precautions Caution The LeadCare II Blood Lead Analyzer is a CLIA-waived device. Facilities that perform tests with the LeadCare II System must have a CLIA Certificate of Waiver as issued under the authority of the Public Health Service Act (PHSA) (42 U.S.C. 263(a). In addition to a waiver certificate, laboratories performing this test must comply with all applicable state and local laws. Any modifications by the laboratory to the test system or the manufacturer s instructions will result in the test no longer meeting the requirements of the waived category. All laboratories eligible for a CLIA Certificate of Waiver must follow the manufacturer's instructions as specified in the LeadCare II User's Guide, LeadCare II Quick Reference Guide and LeadCare II Test Kit package insert. Observe universal precautions for handling blood samples as defined by the U.S. Public Health Service, Centers for Disease Control. Refer to the LeadCare II User's Guide for information about where to find this document. The LeadCare treatment reagent contains dilute hydrochloric acid solution. The reagent is harmful if swallowed. Keep out of reach of children. If swallowed, consult a physician. If the reagent contacts eyes, flush immediately with water and consult a physician. Do not mix components from different lots of test kits. Test kit components (kit box, sensors, controls, and treatment reagent tubes) are labeled with expiration dates. Using any item with an expired date may produce inaccurate results. Do not use any component with an expiration date that has passed. Check the expiration on the kit box as this is the earliest date. Proper sample preparation is essential for accurate results. Take precautions to ensure that the sample collection area is not contaminated by environmental sources of lead. Refer to Collecting and Handling Blood Lead Samples 2004 published by the Department of Health and Human Services, Centers for Disease Control. Use only fresh, whole blood. Mix the blood with treatment reagent within 24 hours of collection. Follow sample collection instructions exactly. 54 F 97 F Wear protective gloves, safety glasses and lab coats. Dispose of materials in appropriate biohazard containers. Allow analyzer, test kit and samples to reach room temperature before testing.

Required Materials D LeadCare II Blood Lead Testing System LeadCare II LeadCare II BLO OD LE A D ANALYZ E R LeadC Blood Testing S erence Card User's guide Calibration button reader LeadCare II Blood Lead Analyzer Sensor retainer AC power cord Instructional CD-ROM Quick reference guide AA batteries Required Materials Analyzer Kit Contents Test Kit Contents Droppers Treatment reagent tubes Capillary tubes and plungers Calibration button Control solutions Blood lead sensors Labels Package insert LeadCare II worksheet Power on the Analyzer I POWER I POWER I POWER Connect the analyzer to an outlet using the AC power cord or install batteries as shown below. Battery Installation (Optional) 2 I POWER 1 Push white tab up and pull blue cover off. To turn ON the analyzer, move the switch to the left. IOIOI 2 1 - I POWER + - To turn the analyzer OFF, move the switch to the right. 2 + IOIOI Insert batteries as shown and replace cover. - 3 + - + 4

Analyzer Calibration and Quality Control Perform this calibration procedure each time you open a new Test Kit. 1 2 The first time you turn on the analyzer, you will see the PLEASE CALIBRATE message. Remove the calibration button from the Test Kit. 3 4 CALIBRATION SUCCESSFUL LeadCare II LeadCare II Hold the calibration button to the button reader until you hear a beep. NOTE: Button must touch both the center contact and metal side of button reader. Make sure the number on the button matches the display. The analyzer is ready when the PREPARE SAMPLE message appears. Quality Control LeadCare II Blood Lead Controls are intended to monitor the accuracy and precision of your blood lead testing using the LeadCare II Blood Lead Testing System. How Often to Test with Controls Test two levels of quality control: on each new lot of test kits received on each new shipment of test kits received to test the technique of new users if you suspect that the test kit may not have been stored properly at any time you think that the system may not be working properly Results obtained on control samples that are within the expected ranges means that your LeadCare II System is operating properly. Refer to the LeadCare II User's Guide for additional important information on quality control.

Using the Controls (See Prepare the Sample for Additional Information) Treat the controls as you would a patient blood sample. Refer to the LeadCare II User's Guide for detailed instructions on how to perform blood lead testing. 4 5 6 Label a fresh treatment reagent tube Level 1 Control. After thorough mixing, remove the cap from the Level 1 control vial and place it top down on a clean laboratory wipe. 7 8 9 Holding the capillary tube almost horizontally with the green band on top, fill the tube to the 50 µl black line. Replace the cap on the control vial. Calibration & Quality Control Wipe the outside of the capillary to remove any excess control. Inspect the capillary tube to confirm that it is properly filled. Place the capillary tube into the treatment reagent tube. Insert a plunger into the top of the capillary tube. Dispense the entire volume of control into the reagent. Replace the tube cap. Invert the tube 8 to 10 times to mix the sample completely. Control material in treatment reagent tube will appear red. Analyze the control sample according to the instructions provided in the Analyze the Sample section. Repeat this process for the Level 2 control. Lead Control Test Results: Expected Results Control target values and acceptable ranges are provided on the control vial label. The blood lead result you obtain for a control should be within the acceptable range. If the results are not within the listed range, refer to the Troubleshooting section of the User's Guide. If, after following the instructions, the controls are still out of range, call ESA Technical Support at 1-800-275-0102. CAUTION: Do NOT proceed to patient samples unless both Level 1 and Level 2 control results are within the acceptable ranges.

Prepare the Sample 1 2 Label the tube with the patient ID using the labels provided. Holding the capillary tube almost horizontally with the green band on top, fill the capillary to the 50 µl black line. Note: The CDC s Steps for Collecting Fingerstick Blood Samples for Lead Testing is provided in Appendix C of the User s Guide. 3 4 OR If using blood from a tube, make sure the blood is well mixed by inverting the tube 8 to 10 times before sampling. Hold the capillary tube almost horizontally with the green band on top, fill the tube to the 50 µl black line. Remove excess blood from the outside of the tube with a clean wipe or gauze. Use caution not to drain the blood from the end of the capillary tube.

5 6 Wrong Wrong Wrong Air Excess Correct Underfilled Bubbles Blood Inspect the capillary tube for proper filling. Make sure there are no gaps or bubbles, or any excess blood on the outside of the capillary. Place the capillary tube into the treatment reagent tube. Insert a plunger into the top of the capillary tube. Dispense the entire volume into the bottom of the tube. 7 8 Prepare the Sample Replace the tube cap. Invert the tube 8 to 10 times to mix the sample completely. The sample is ready when the mixture turns brown. Samples may be stored up to one week if refrigerated. CAUTION: Any visual impairment, such as color blindness may affect the operator's ability to detect the sample color change. Operators with vision deficiencies should invert the tube 8 to 10 times to ensure that the sample is properly mixed.

Analyze the Sample 1 2 LeadCare II Remove a sensor from the sensor container. Close the container. Insert the sensor (with black bars facing up) completely into the analyzer until you hear a beep. 3 4 LeadCare II Make sure the sensor lot number matches the display. Make sure the sample is thoroughly mixed. Allow samples that were stored refrigerated to reach room temperature before use. 5 6 adcare II Remove the cap from the tube. Squeeze the walls of the dropper and insert into the sample. Release the pressure to draw some sample into the dropper. Touch the dropper tip to the X on the sensor and squeeze the walls to dispense the sample.

7 8 Wait 3 minutes until the test is done. The analyzer will beep and display the lead result in µg/dl Pb. Record the test results on the LeadCare II worksheet provided. 9 10 Remove the used sensor. 11 Discard materials in appropriate containers. 12 Analyze the Sample The analyzer is ready for the next sample. The analyzer displays Low when it detects a blood lead level below 3.3 ug/dl. Low results should be recorded as < 3.3 µg/dl. The majority of your patient samples should produce Low results.

Interpreting Patient Test Results Interpreting Patient Test Results The analyzer s display window shows the blood lead result. The result is in micrograms (µg) of lead per deciliter (dl) of whole blood. No calculation is needed. Results are displayed to one decimal place. The reportable range of the test is 3.3 to 65 µg/dl. Low in the display window indicates a blood lead test result less than 3.3 µg/dl. When this occurs, report the blood lead result as less than (<) 3.3 µg/dl. High in the display windows indicates a blood lead test result greater than 65.0 µg/dl. When this occurs, report the blood lead result as greater than (>) 65 µg/dl. Blood lead test results should be shared with the patient s physician for interpretation and to determine when retesting and follow-up care are necessary. Blood lead levels less than 10 µg/dl are below the level of concern. Blood lead levels above 10 µg/dl indicate possible lead poisoning, which is a serious medical condition. Patients with blood lead levels above 10 µg/dl must be confirmed with a venous sample. The following table shows when to test patients again if the result is above 10 µg/dl. 1 Retesting Guidelines If blood lead result of screening test is: Perform diagnostic test on venous blood within: 10 19 µg/dl 3 months 20 44 µg/dl 1 month to 1 week (the higher the result, the more urgent the need for follow-up testing) 45 59 µg/dl 48 hours 60 69 µg/dl 24 hours Greater than or equal to 70 µg/dl Immediately as an emergency lab test When the LeadCare II display reads High, the analyzer has detected a blood lead level greater than 65 µg/dl. High results on LeadCare II should be followed up immediately as an emergency laboratory test. Venous confirmation samples can be tested on the LeadCare II System to rule out contamination in the first sample. However, if the result of the venous sample is also above 10 µg/dl, ESA recommends that you send the venous sample to a reference laboratory for confirmation by another method. NOTE: If you are concerned about the accuracy of results near the 10 µg/dl threshold, ESA recommends that you set the confirmation threshold at 8 µg/dl, and have venous samples sent out for confirmation by a reference laboratory. Report all blood lead test results to the appropriate state or federal agency. Contact your State Childhood Lead Poisoning Prevention Program for the specific case management guidelines that apply to your patients. 1 CDC (Centers for Disease Control). Screening Young Children for Lead Poisoning: Guidance for State and Local Public Health Officials. Atlanta: CDC, 1997.

Maintenance Interpreting Results Maintenance Maintaining the Analyzer Clean the analyzer with a damp cloth and warm, soapy water. Do not immerse in water. Disinfect with dilute (10%) bleach solution. Do not leave any soap film on the analyzer. Do not allow liquid of any kind into the sensor connector. Do not wash the inside of the calibration button reader. Remove the sensor retainer to clean. Dry thoroughly before reinstalling. ESA Biosciences Technical Support Number 1-800-275-0102

Troubleshooting STARTUP MESSAGES DEFINITION WHAT TO DO PLEASE CALIBRATE Analyzer must be calibrated the first Calibrate the analyzer. Refer to the ANALYZER WITH BUTTON time you use it. calibration instructions in this guide. TEMP IS TOO HOT The temperature is too hot for testing. Wait until the screen displays PLEASE WAIT UNTIL the PREPARE SAMPLE message. ANALYZER IS IN TEMP RANGE TEMP IS TOO COLD The temperature is too cold for testing. Wait until the screen displays PLEASE WAIT UNTIL the PREPARE SAMPLE message. ANALYZER IS IN TEMP RANGE ELECTRONIC The internal quality control check Call ESA Biosciences Technical QC CHECK FAILED failed. Support at 1-800-275-0102. CALL TECH SERVICE ERROR X PROCESSING MESSAGES DEFINITION WHAT TO DO WARNING The temperature is changing rapidly. Allow system temperature to stabilize. TEMP IS UNSTABLE This message flashes for 2 seconds. TEST MAY FAIL THIS IS A USED SENSOR The sensor in the analyzer is wet Remove the used sensor or adjust the PLEASE REMOVE SENSOR or previously used. new sensor until the screen displays the PREPARE SAMPLE message. PLEASE REMOVE SENSOR A sensor was left in the analyzer. Remove the sensor. SENSOR OUT OF VIAL The sensor in the analyzer has been Remove the sensor and insert a new TOO LONG out of the container too long and sensor. PLEASE REMOVE SENSOR cannot be used. TEST FAILED There is not enough sample on the Remove the sensor, discard it and PLEASE REMOVE SENSOR sensor or the sensor failed. insert a new sensor. When adding the sample to the sensor, make sure the sample covers the X area. SENSOR REMOVED TOO SOON The sensor was removed from the Remove the sensor, discard it, insert a analyzer before the end of the test. new sensor and add another drop of sample. Wait 180 seconds (3 minutes) for the test to finish. TEMP IS UNSTABLE The temperature in the room is too Move the analyzer to an area where RESULT DISCARDED unstable to yield accurate test results. there are fewer temperature changes PLEASE REMOVE SENSOR (away from sources of cold or heat). The temperature is stable enough when the PREPARE SAMPLE message indicates that the Analyzer is ready. PLEASE RECALIBRATE There was a problem with transferring Repeat the calibration procedure. the calibration data to the analyzer Refer to the calibration procedure from the calibration button. in this guide. SYSTEM FAILURE One of the main system Call ESA Biosciences Technical CALL TECH SERVICE components failed. Service at 1-800-275-0102. PLEASE CALIBRATE The analyzer must be calibrated Calibrate the analyzer. Refer to the ANALYZER WITH BUTTON before you can use it. calibration instructions in this guide. The PREPARE SAMPLE message indicates that the analyzer is ready to use. SENSOR LOT TOO OLD The sensor is from a lot that has Discard the sensor and the expired PLEASE RECALIBRATE expired. lot. Use a sensor from a new lot and recalibrate the analyzer. CHANGE BATTERIES SOON Message flashes before or after a Change the batteries. Use four 1.5 V test. Voltage is too low for the AA alkaline batteries. analyzer to run a test.

Troubleshooting of Inaccurate Results Scenario 1: Troubleshooting results below the target or expected value Make sure the analyzer is calibrated to the sensor lot in use. Check the expiration date on the test kit box. Do NOT use a test kit that is beyond the expiration date. Note: the analyzer will not perform a test when it is calibrated for a sensor lot that has expired. Use only fresh, whole blood from patients. Do NOT use plasma or serum. Less than 50 µl in the capillary tube will tend to produce lower blood lead results. Make sure that there are no clots or bubbles in the capillary tube. Always mix the blood sample with treatment reagent. Results generated with untreated blood are not accurate. Do NOT use clotted blood. If there are clots in the blood, obtain a new sample. Operate the analyzer only within the specified humidity range 12 to 80% relative humidity. Make sure that the analyzer, test kit, and sample are all at the same temperature before testing. Note: The analyzer will not initiate a test if the temperature is changing too rapidly, or if the temperature is outside of the operating range. Avoid operating the LeadCare II System in drafts. Make sure the blood and treatment reagent is thoroughly mixed before placing onto the sensor. Keep the lid on the sensor container closed to protect unused sensors. Do NOT touch the sensor while running a test. Scenario 2: Troubleshooting results above the target or expected value Make sure the analyzer is calibrated to the sensor lot in use. Check the expiration date on the test kit box. Do NOT use a test kit that is beyond the expiration date. To avoid contamination, thoroughly clean the sample site prior to puncture. Use clean gloves during testing and keep your gloved hands clean. Make sure you are using lead-free collection devices. Do NOT touch the ends of the capillary tubes or the plungers. This could cause contamination. Excess blood on capillary tube. Be sure to wipe excess blood from the tube with a downward motion. The accuracy of the test depends on filling the capillary tube with 50 µl. Excess blood on the outside of the tube will tend to produce higher blood lead results. Do NOT use clotted blood. If there are clots in the blood, obtain a new sample. Do NOT leave the treatment reagent tube uncapped other than to add the blood sample and remove the blood sample/treatment reagent mixture. Make sure to thoroughly mix blood with the treatment reagent. The mixture should turn brown before you place it on the sensor. Operate the analyzer only within the specified humidity range 12 to 80% relative humidity. Make sure that the analyzer, test kit, and sample are all at the same temperature before testing. Do NOT use a sensor that has been dropped on the floor or exposed to contaminants. Do NOT touch the sensor while running a test. If you have any doubt about the accuracy of your results, refer to the Troubleshooting section of the User's Guide. If, after following the instructions, the problem persists, call ESA Biosciences Technical Support at 1-800-275-0102. Troubleshooting

To place an order, call 1-800-959-5095. Analyzer: LeadCare II Analyzer Kit 70-6760 Reagents: LeadCare II Test Kit 70-6762 Parts and Accessories: Label Printer (U.S. only) 70-3447 Printer Labels 70-3443 AA Batteries (4 Pack) 50-0005 Sensor Retainer 70-6543 Quick Reference Guide 70-6552 User s Guide 70-6551 Instructional CD-ROM 70-6554 AC Power Cord 70-6692 International Power Plug Set 70-6693 ESA Biosciences Technical Support Number 1-800-275-0102 LeadCare II Serial Number: ESA Biosciences, Inc. 22 Alpha Road, Chelmsford, MA 01824 USA (800) 275-0102 www.esainc.com Copyright 2005-2007. ESA Biosciences Inc. Produced under the following U.S. Patent Numbers: 5,368,707; 5,468,366; 5,217,594; 5,873,990 Part Number: 70-6552 Rev C