BIS Technology Enabling safety and quality improvements in the cardiac operating room

Similar documents
A SAFE AND EFFECTIVE WAY TO OPTIMIZE ANESTHESIA DURING SURGERY

Hypotension after induction, corrected with 20 mg ephedrine x cc LR EBL 250cc Urine output:

Depth of Anesthesia Monitoring in Cardiac Surgery. Adam Dryden MD, FRCPC University of Ottawa Heart Institute

Depth of anaesthesia monitors Bispectral Index (BIS), E-Entropy and Narcotrend-Compact M

BIS Brain Monitoring for Critical Care

Awareness: Where do we stand?

The Effect of Bispectral Index Monitoring on Anesthetic Use and Recovery in Children Anesthetized with Sevoflurane in Nitrous Oxide

Diagnostics consultation document

BIS Monitoring. ASSESSMENT OF DEPTH OF ANAESTHESIA. Why measure depth of anaesthesia? or how to avoid. awareness in one easy lesson

Brain Monitoring of Anesthetic Effect

Original Article INTRODUCTION. Abstract

REFERENCE GUIDE USING THE BISPECTRAL INDEX (BIS ) MONITORING SYSTEM FOR CRITICAL CARE

Monitoring Consciousness Using the Bispectral Index During Anesthesia

Original Article. * Received for Publication: September 2, 2006 * Revision Received: December 27, 2006 * Revision Accepted: April 4, 2007

awareness during general anaesthesia. implications of explicit intraoperative recall

Monitoring for Unconsciousness During General Anaesthesia

Postgraduate Course of Anesthesiology What does anesthesia do with the brain? September 23, 2013 UZ Leuven

Abstract Patients and Methods:

2 Benefits of depth of anaesthesia monitors

May 2006 Page 1 / 5 Danmeter A/S

W J A. World Journal of Anesthesiology. Awareness during anesthesia: Current status in Japan. Abstract INTRODUCTION MINIREVIEWS.

Remifentanil. Addressing the challenges of ambulatory orthopedic procedures 1-3

National Institute for Health and Clinical Excellence Depth of anaesthesia monitoring (E-Entropy, Bispectral Index and Narcotrend)

The correlation of bispectral index with endtidal sevoflurane concentration and haemodynamic parameters in preschoolers

Kent CD: Awareness during general anesthesia: ASA Closed Claims Database and Anesthesia Awareness Registry. ASA Newsletter 74(2): 14-16, 2010

Increasing isoflurane concentration may cause paradoxical increases in the EEG bispectral index in surgical patients

Importance of Anaesthesiology in Indian Healthcare: A Review

Evaluation of Postoperative Complications Occurring in Patients after Desflurane or Sevoflurane in Outpatient Anaesthesia: A Comparative Study

SEEING KETAMINE IN A NEW LIGHT

Monitoring cortical electrical activity in anesthesia for obese patient

Type of intervention Anaesthesia. Economic study type Cost-effectiveness analysis.

Section 8: Accidental awareness during general anaesthesia

The bispectral index (BIS) monitor was developed

Pediatric Evaluation of the Bispectral Index (BIS) Monitor and Correlation of BIS with End-tidal Sevoflurane Concentration in Infants and Children

Article XIII ANALGESIA, CONSCIOUS SEDATION, DEEP SEDATION, AND GENERAL ANESTHESIA RULES FOR A DENTIST IN AN AMBULATORY FACILITY

Randomized, Double-Blind, Controlled Trial. Abstract. imedpub Journals

Comparing Patient Recovery after Laparoscopic Surgery for Women using Bispectral Index and Standard Clinical Method

January 27, 1992 to November 26, A total of 120 patients (60/site) were enrolled in the study as follows: PATIENT ENROLLMENT

Mr David A McDonald Service Improvement Manager Whole System patient Flow Improvement Programme Scottish Government

Use of cerebral monitoring during anaesthesia: Effect on recovery profile

SECTION 8: ACCIDENTAL AWARENESS DURING GENERAL ANAESTHESIA

Bio Anesthetic Monitor

COMPARISON OF RECOVERY PROFILES OF PROPOFOL & SEVOFLURANE ANESTHESIA WITH BISPECTRAL INDEX MONITORING (BIS) IN GENERAL ANESTHESIA

Michel MRF Struys, MD, PhD, FRCA

Bispectral Index Monitoring Improves the Cognitive Function after Desflurane Anaesthesia in Elderly Patients Undergoing Spine Surgery

If you reduce variability in volume administration, HOW. you can reduce post-surgical complications, LOS and associated costs 1-4

UTILITY OF BISPECTRAL INDEX (BIS) MONITORING DURING GENERAL ANESTHESIA

Advancing the Art and Science of Anesthesia Control SNAP II TM. Monitor at a Higher Level

A PROSPECTIVE, RANDOMIZED COMPARISON OF THE EFFECTS OF THIOPENTAL AND PROPOFOL ON BISPECTRAL INDEX DURING CAESAREAN SECTION TILL DELIVERY OF NEWBORN

Setting The setting was tertiary care. The economic study appears to have been performed in Heidelberg, Germany.

REVIEW ARTICLES INTRAOPERATIVE AWARENESS: MAJOR FACTOR OR NON-EXISTENT?

Measure Abbreviation: PONV 01 (MIPS 430)

Multi-center (5 centers); United States and Canada. September 10, 1992 to April 9, 1993

When Is a Bispectral Index of 60 Too Low?

Bispectral Index Monitoring Improves the Cognitive Function After Desflurane Anaesthesia in Elderly Patients Undergoing Spine Surgery

Manual versus target-controlled infusions of propofol

Intraoperative awareness during general anaesthesia: results of an observational study

Awareness during anesthesia--an update.

Kinetics and Monitoring of Inhaled Anesthetics. Copyright , James H Philip, all rights reserved

Depth of anaesthesia monitoring

AAGBI Core Topics 2013 Depth of Anaesthesia Monitoring

Level of sedation evaluation with Cerebral State Index and A-Line Arx in children undergoing diagnostic procedures

Table 1. Relevant Publications by Company Investigators and Colleagues

Intraoperative awareness: controversies and non-controversies

Closed-Loop Control of General Anesthesia: My Clinical Experience

USAGE OF VARIOUS CONCENTRATIONS OF KETAFOL FOR DILATATION AND CURETTAGE

J Formos Med Assoc 2010;109(8): Contents lists available at ScienceDirect. Journal of the Formosan Medical Association

Age-related requisite concentration of sevoflurane for adequate sedation with combined epidural-general anesthesia

Can Depth of Anesthesia Monitoring Alter the Incidence of Mortality, POCD or Delirium?

JOURNAL OF INTERNATIONAL ACADEMIC RESEARCH FOR MULTIDISCIPLINARY Impact Factor 3.114, ISSN: , Volume 5, Issue 4, May 2017

Effect of preoperative oral amantadine on intraoperative anesthetic and analgesic requirements in female patients during abdominoplasty

Abstract. Keywords: General anaesthesia, Perioperative awareness, Depth of general anaesthesia, Bispectral index INTRODUCTION

The Commonwealth of Virginia REGULATIONS GOVERNING THE PRACTICE OF DENTISTRY VIRGINIA BOARD OF DENTISTRY Title of Regulations: 18 VAC et seq.

4/18/2018. Disclosure. Learning Objectives. St. Vincent Healthcare. Supportive Literature. Background

TITLE 5 LEGISLATIVE RULE WEST VIRGINIA BOARD OF DENTISTRY SERIES 12 ADMINISTRATION OF ANESTHESIA BY DENTISTS

Spectral entropy measurement of patient responsiveness during propofol and remifentanil. A comparison with the bispectral index {

Postoperative cognitive dysfunction a neverending story

Awake regional versus general anesthesia in preterms and ex-preterm infants for herniotomy

Pediatric Sedation Pocket Reference

Procedural Sedation. Conscious Sedation AAP Sedation Guidelines: Disclosures. What does it mean for my practice? We have no disclosures

Depth of anaesthesia monitoring: what s available, what s validated and what s next?

POCD: What is it and do the anesthetics play a role?

Awareness during anesthesia: A rare but disturbing complication According to the American Society of Anesthesiologists

Enhancing patient care in the ICU with NeuroMonitoring

Richard A. Beers, M.D. Professor, Anesthesiology SUNY Upstate Medical Univ VA Medical Center Syracuse, NY

Summary question. How can pain relief during childbirth be improved? How can anaesthesia for Caesarean sections be improved?

Guidelines for preventing and managing accidental awareness during general anesthesia

Recovery of psychomotor function after propofol sedation is prolonged in the elderly

Abstract. Introduction

A Comparison of Spinal, Epidural, and General Anesthesia for Outpatient Knee Arthroscopy

"Gentlemen, this is no humbug" Dr John Collins Warren, 17 October : Horace Wells 1846: William T. Morton

Dae-hee Kim 1, Ji-young Yoo 1, Jong-Yeop Kim 1, Soo-hwan Ahn 1, Seongsu Kim 2, and Sang-kee Min 1. Clinical Research Article

Anesthesia: Analgesia: Loss of bodily SENSATION with or without loss of consciousness. Absence of the sense of PAIN without loss of consciousness

PERIOPERATIVE MEDICINE

Management of post-strabismus nausea and vomiting in children using ondansetron: a value-based comparison of outcomes 1^

REGIONAL/LOCAL ANESTHESIA and OBESITY

Regulations: Minimal Sedation. Jason H. Goodchild, DMD

Chapter 25. General Anesthetics

Postoperative Pain Experience: Results from a National Survey Suggest Postoperative Pain Continues to Be Undermanaged

Transcription:

BIS Technology Enabling safety and quality improvements in the cardiac operating room

BIS technology backs you up with proven brain monitoring. Using the BIS monitor has made me more of a scientist and a more perceptive clinician. It is, in short, an essential part of modern anesthesia. Irene Osborn, MD Mt. Sinai Medical Center Given the complexity of the decisions you face, it makes sense to incorporate the added security of BIS monitoring into your practice. Used in millions of procedures requiring anesthesia, BIS technology can provide insight into the direct and patient-specific effects of anesthesia on the brain. how bis works Raw EEG data are obtained through a sensor placed on the patient s forehead The BIS system processes the EEG information and calculates a number between 0 and 100 that provides a direct measure of the patient s level of consciousness A BIS value of 100 indicates the patient is fully awake A BIS value of 0 indicates the absence of brain activity BIS Index Range BIS Range and Clinical State 100 Awake Responds to normal voice Light / Moderate Sedation 80 May respond to loud commands or mild prodding / shaking 60 General Anesthesia Low probability of explicit recall Unresponsive to verbal stimulus 40 Deep Hypnotic State 20 Burst Suppression 0 Flat Line EEG This chart reflects a general association between clinical state and BIS values. Ranges are based on results from a multi-center study of the BIS involving the administration of specific anesthetic agents. BIS values and ranges assume that the EEG is free of artifacts that can affect its performance. Titration of anesthetics to BIS range should be dependent upon the individual goals established for each patient. These goals and associated BIS ranges may vary over time and in the context of patient status and treatment plan.

Insight into brain responses 1 BIS can help clarify the distinction between brain and spinal cord responses, enabling you to manage anesthetic goals of hypnosis, analgesia, and immobility Brain Consciousness Memory function Because BIS measures electrical activity in the brain, it provides a direct correlation with depth of consciousness (hypnosis) Responses to surgical stimulation are frequently indicators of the need for additional analgesia. These responses are often mediated in the spinal cord BIS enables you to assess consciousness and sedation separately from cardiovascular reactivity HYPNOSIS BALANCED ANESTHESIA Spinal Cord Analgesia reflex movement ANALGESIa IMMOBILITY

BIS Improves Safety and Efficiency in the OR BIS monitoring and reduced risk of awareness in adults The Cochrane Review on BIS Author s conclusion: Anaesthesia guided by BIS within the recommended range (40-60) could improve anaesthetic delivery and postoperative recovery from relatively deep anaesthesia. In addition, BIS-guided anaesthesia has a significant impact on reduction of the incidence of intra-operative recall in surgical patients with a high risk of awareness. 13 Research demonstrates that awareness with recall occurs in 1 to 2 patients per 2, 3, 4 1000 receiving general anesthesia. Awareness is a leading cause of patient dissatisfaction with anesthesia. 5 BIS is the only consciousness monitoring technology proven in rigorous prospective clinical studies to help clinicians reduce the incidence of awareness with recall in adults by approximately 80%. 6, 8 20,000 to 40,000 cases of awareness with recall occur each year in the US. BIS monitoring may play a role in helping health care organizations address the recommendations proposed in the JCAHO Sentinel Event Alert 2 on preventing and managing the impact of anesthesia awareness. Myles, et al. Trial 6 Avidans, et al. Trial 7 Ekman, et al. Trial 8 Observed incidence of awareness with recall 1% 11 cases 1.0% 1% Reduction in incidence of awareness with recall in adults (high risk patients p<.05) 0.75% 0.2% 14 cases Reduction in incidence of awareness with recall in adults (general patient population p<.05) 0.5% 0.50% 0.1% 82% 0.21 0.25% 0.21 2 cases 2 cases 2 cases 0% Standard Practice BIS-guided 0% BIS-guided Expected incidence ETAG 0% Historical (No BIS) protocol protocol of Awareness in protocol Control n=1,238 n=1,225 n=967 High Risk Patients n=974 n=7,826 77% 2 cases BIS-guided protocol n=4,945

patients oriented on arrival at pacu More patients oriented on arrival at PACU 9 BIS monitoring and faster wake ups 9 BIS-monitored patients wake up faster, are extubated sooner, and are more oriented on arrival at the post-anesthesia care unit (PACU). 50% 40% 30% 20% 23% 87% 43% 10% 0% Standard Practice BIS Titrated PACU discharge time 200 195 BIS monitoring and shorter PACU stays 10 BIS-monitored patients have been shown to be eligible for PACU discharge 32% sooner. 180 160 Faster discharge from PACU 10 140 32% 132 120 Standard Practice BIS Titrated BIS monitoring and drug savings 9-12 % reduction in drug utilization with bis Multiple prospective randomized studies have measured the influence of BIS-guided anesthesia care compared to standard practice. 1300 1200 1100 1253 mg Reduction in drug utilization with BIS 9 Studies have shown reductions in the use of 1000 23% hypnotic anesthetics when anesthetics are titrated to the BIS index. 900 800 Standard Practice 964 mg BIS

BIS information enables us to give each patient the precise amount of anesthetic they require, thereby increasing efficiency and reducing the risk of awareness and postoperative side effects of drugs, such as nausea and vomiting. With BIS, patients wake faster, feel more alert, and go home earlier. James Mayfield, MD Medical Director of Perioperative Services Medical College of Georgia Health System Improving quality and safety for a variety of patients 6,9,11,12,14 BIS offers you added security in providing specialized care and comfort for your patients, including those who may be more sensitive to the hemodynamic effects of anesthesia. BIS provides valuable information about the status of your patients to help address their unique anesthetic requirements. This may be particularly valuable for: Patients with complex conditions whose status may suddenly or frequently change Patients with cardiovascular conditions Obese patients Trauma patients or others requiring reduced levels of anesthesia Widely studied, widely accepted, widely integrated BIS technology is Supported by thousands of published articles and abstracts Available extensively throughout Europe, Asia, Australia, and the Americas Licensed for integration into the patient monitoring systems of leading manufacturers

BIS is an invaluable teaching tool it equips my students with the information they need to determine when they can safely titrate back their anesthetic. The added confidence that BIS provides has a significant impact on the quality and efficiency of the anesthesia they administer. John O Donnell, CRNA University of Pittsburgh Medical Center BIS is ready when you are You can now access the full benefits of BIS technology with BISx, a device that allows you to interface with any BIS Ready patient monitoring system. Simply plug BISx into a BIS Ready system and BIS information is displayed along with other vital signs.* BISx integrates with systems in virtually every health care environment, from highend systems in ORs and intensive care units (ICU) to preconfigured systems in ambulatory surgery centers or procedural sedation locations. BISx also provides the flexibility to travel with the patient throughout the hospital (requires compatible brand/connectors on patient monitoring systems). *Available in select monitors. The BIS family of sensors The family of BIS sensors includes The Quatro Sensor for adult patients undergoing general anesthesia or sedation The Extend Sensor for adult patients monitored for a long period of time, such as those in the ICU The Pediatric Sensor for smaller patients The Bilateral Sensor to enable detection of hemispheric differences in the brain which may prove useful for advanced monitoring applications* *Bilateral hardware required. Hardware includes BISx4 and PIC-4 cable. BIS QUATRO BIS PEDIATRIC BIS BILATERAL

BIS solutions to meet your needs. Covidien offers the proven brain function monitoring of BIS in a variety of solutions to provide you with the flexibility to monitor across the continuum of care. BIS VISTA Monitoring System BIS Fully Integrated Seamless solution Datascope * Dixtal * BIS VISTA Bilateral Monitoring System Dräger Medical * General Electric * Mennen Medical * Mindray * BIS VIEW Monitoring System Nihon Kohden * Philips * SpaceLabs Healthcare * References: 1. Dershwitz M. Should we measure depth of anesthesia? Semin Anesth Perioper Med Pain. 2001;20:246-256. 2. Joint Commission on Accreditation of Healthcare Organizations: Preventing, and managing the impact of, anesthesia awareness. Sentinel Event Alert. Oct 6, 2004;(32):1-3. 3. Practice Advisory for Intraoperative Awareness and Brain Function Monitoring: A Report by the American Society of Anesthesiologists Task Force on Intraoperative Awareness. Anesthesiology. 2006;104:847-64. 4. Sebel PS, Bowdle TA, Ghoneim MM, et al. The incidence of awareness during anesthesia: A Multicenter United States Study. Anesth Analg. 2004;99:833-839. 5. Myles PS, Williams DL, Hendrata M, et al. Patient satisfaction after anaesthesia and surgery: results of a prospective survey of 10,811 patients. Br J Anaesth. 2000;84:6-10. 6. Myles PS, Leslie K, McNeil J, et al. Bispectral Index monitoring to prevent awareness during anaesthesia: the B-Aware randomized controlled trial. Lancet. 2004;363:1757-1763. 7. Avidan M, et al. The New England Journal of Medicine. 2008; 358:1097-108. 8. Ekman A, Lindholm ML, Lennmarken C, et al. Reduction in the incidence of awareness using BIS monitoring. Acta Anaesthesiol Scand. 2004;48:20-26. 9. Gan TJ, Glass PS, Windsor A, et al. Bispectral Index monitoring allows faster emergence and improved recovery from propofol, alfentanil, and nitrous oxide anesthesia. BIS Utility Study Group. Anesthesiology. 1997;87:808-815. 10. White PF, Ma H, Tang J, et al. Does the use of electroencephalographic Bispectral Index or auditory evoked potential index monitoring facilitate recovery after desflurane anesthesia in the ambulatory setting? Anesthesiology. 2004;100:811-817. 11. Wong J, Song D, Blanshard H, et al. Titration of isoflurane using BIS Index improves early recovery of elderly patients undergoing orthopedic surgeries. Can J Anaesth. 2002;49:13-18. 12. Luginbuhl M, Wuthrich S, Petersen-Felix S, et al. Different benefit of Bispectral Index (BIS) in desflurane and propofol anesthesia. Acta Anaesthesiol Scand. 2003;47:165-173 13. Punjasawadwong Y, Boonjeungmonkol N, and Phongchiewboon A. Bispectral Index for Improving Anaesthetic Delivery and Postoperative Recovery. Cochrane Database of Systematic Reviews, 2007; 17(4): CD003843. 14. Burrow B, McKenzie B, Case C. Do anaesthetized patients recover better after Bispectral Index monitoring? Anaesth Intensive Care. 2001;29:239-245. COVIDIEN, COVIDIEN with logo, Covidien logo and positive results for life are U.S. and/or internationally registered trademarks of Covidien AG. Other marked brands are trademarks of a Covidien company. - * Trademark of its respective owner. 2010 Covidien. All rights reserved. - C-MN-BISCardSurgTech/GB - 03/2010 Covidien (UK) Commercial Ltd 154 Fareham Road Gosport Hampshire PO 13 OAS United Kingdom (UK) +44 (0) 1329 224226 [t] +44 (0) 1329 224334 [f] www.covidien.com