Quick Reference Guide

Similar documents
Challenging anatomies demand versatility.

Zenith Renu AAA Converter Graft. Device Description Planning and Sizing Deployment Sequence Patient Follow-Up

Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully

Access More Patients. Customize Each Seal.

Talent Abdominal Stent Graft

Cook Medical. Zenith Flex AAA Endovascular Graft with Z-Trak Introduction System Physician Training

Ancillary Components with Z-Trak Introduction System

RadRx Your Prescription for Accurate Coding & Reimbursement Copyright All Rights Reserved.

LOWERING THE PROFILE RAISING THE BAR

1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER

Zenith Alpha T HORACIC ENDOVASCULAR GRAFT

CLARIVEIN INFUSION CATHETER

ER REBOA Catheter. Instructions for Use

FROM THE EVERYDAY TO THE EXTRAORDINARY

Hostile Proximal Neck: A New Conformable EVAR Device

CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE

History of the Powerlink System Design and Clinical Results. Edward B. Diethrich Arizona Heart Hospital Phoenix, AZ

ENG TREO ABDOMINAL STENT-GRAFT SYSTEM TABLE OF CONTENTS

Nit-Occlud. Coil System for PDA Closure IMPLANTATION POCKET GUIDE. Rx only CV / B. Braun Interventional Systems Inc.

TriVascular Ovation Prime Abdominal Stent Graft System

Robert F. Cuff, MD FACS SHMG Vascular Surgery

AXS Catalyst Distal Access Catheter

A New EVAR Device for Infrarenal AAAs

Home Health Foundation, Inc. To create more permanent IV access for patients undergoing long term IV therapy.

2015 Clinical Update Endovascular Systems for AAA Repair

AXIOS Stent and Electrocautery Enhanced Delivery System. Quick Reference Guide

How to do AAA EVAR: Tips and Tricks

Optimizing Accuracy of Aortic Stent Grafts in Short Necks

Phoenix Atherectomy System Product Overview /LB

Instructions for Use

Instructions for Use Cordis PRECISE PRO Rx Nitinol Stent System

The evolution. AORFIX AAA Stent Graft now with the new AORFLEX Delivery System

PTA Balloon Dilatation Catheter

Document No. BMB/IFU/40 Rev No. & Date 00 & 15/11/2017 Issue No & Date 01 & 15/11/2017

Malperfusion Syndromes Type B Aortic Dissection with Malperfusion

Acute dissections of the descending thoracic aorta (Debakey

Instructions for Use

ENCORE, a Study to Investigate the Durability of Polymer EVAR with Ovation A Contemporary Review of 1296 Patients

What's on the Horizon for AAA: Unilateral & Percutaneous, "UP-EVAR" System Zoran Rancic M.D., Ph.D.

Zenith Alpha T HORACIC ENDOVASCULAR GRAFT

Directions For Use. All directions should be read before use

PTA Balloon Dilatation Catheter

Appropriate Device Selection for Endovascular Procedures

Young-Guk Ko, M.D. Severance Cardiovascular Hospital, Yonsei University Health System,

My personal experience with INCRAFT in standard and challenging cases

RECOMMENDED INSTRUCTIONS FOR USE

Durability of The Endurant Stent-Graft through 5 Years

TRAINING DOCUMENT, FOR INTERNAL USE ONLY. Pre-case Planning

Finally, the Control You Need to Deliver Accurate Treatment

Balloon in Balloon (BIB )

GENERAL TECHNIQUE GUIDE

LINEAR 7.5Fr. IAB Catheter

MULTILAYER FLOW MODULATOR (MFM ) FOR PERIPHERAL ANEURYSMS TREATMENT (LOWER LIMBS, VISCERALS AND SUBCLAVIAN)

Right Choice for Right Angles

Aortic stents, types, selection, tricks in deployment.

DIGESTIVE HEALTH ENTERAL FEEDING PRODUCTS

NON-COMPLIANT PTCA RAPID EXCHANGE DILATATION CATHETER

SANWICH TECHNIQUE TO REDUCE COMPLICATIONS WHEN TREATING BILATERAL INTERNAL ILIAC ARTERY

Anatomical challenges in EVAR


Durable outcomes. Proven performance.

ROTABLATORTM. Peripheral. Rotational Atherectomy System. Quick Reference Cards

DEVELOPED BY MEDSHAPE, INC. IN CONJUNCTION WITH PATRICK ST. PIERRE, M.D. BICEPS TENODESIS ARTHROSCOPIC AND SUBPECTORAL SURGICAL TECHNIQUE

2014 ANNUAL CLINICAL UPDATE. TriVascular Inc. Ovation and Ovation Prime Abdominal Stent Graft Systems

Balloon in Balloon (BIB )

Indications for use. Contraindications within the United States

DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service

Ponsky * PEG Safety System - "Pull" Bard * PEG Safety System - "Guidewire" Information for Use

Nellix Endovascular System: Clinical Outcomes and Device Overview

SYNFLATE SYSTEM SURGICAL TECHNIQUE

INSTRUCTIONS FOR USE FOR:

The Art of. Flow Restoration. Ikazuchi Zero. Semi-Compliant PTCA Balloon OVERVIEW CROSSABILITY LOW PROFILE CASE STUDY CODES

RadRx Your Prescription for Accurate Coding & Reimbursement Copyright All Rights Reserved.

GORE EXCLUDER AAA Endoprosthesis ANNUAL CLINICAL UPDATE OCTOBER Section I Clinical experience. Section II Worldwide commercial experience

The Ventana Off-the-Shelf Graft for Pararenal AAA. Andrew Holden Associate Professor of Radiology Auckland Hospital

Current Status of Abdominal Aortic Stent Grafts. John R. Laird Professor of Medicine Director of the Vascular Center UC Davis Medical Center

Thoracic Endovascular Aortic Repair (TEVAR) Indications and Basic Procedure

Instructions for Use 1

Single Use Curlew TM Multiple Biopsy Forceps

Optimal Techniques for Obtaining Large Caliber Arterial Access

The catheter-based treatment of valvular disease and aortic

CP STENT. Large Diameter, Balloon Expandable Stent

The AperFix II System

PTCA Dilatation Catheter. Instructions for Use

AFX. Femoral Implant. System. The AperFix. AM Portal Surgical Technique Guide. with the. The AperFix System with the AFX Femoral Implant

PRODUCTS FOR THE DIFFICULT AIRWAY. Courtesy of Cook Critical Care

ABDOMINAL XT ABDOMINAL STENT GRAFT SYSTEM

Excimer Laser for Coronary Intervention: Case Study RADIAL APPROACH: CORONARY LASER ATHERECTOMY FOR CTO OF THE LAD FOLLOWED BY PTCA NO STENTING

INNOVATIVE PRODUCTS G, J AND GJ-TUBES WITH ENFit TM CONNECTION

Taming The Aorta. David Minion, MD Program Director, Vascular Surgery University of Kentucky Medical Center Lexington, Kentucky, USA

The SplitWire Percutaneous Transluminal Angioplasty Scoring Device. Instructions for Use

Peripheral Arterial Disease: A Practical Approach

Advancing Lives and the Delivery of Health Care. The High-Flow Port Designed for Apheresis

Pocket Reference Guide For (CTO) Technologies

Figure 1: Revolution TM Peripheral Atherectomy System Diagram. Table 1: Revolution TM Peripheral Atherectomy System Specifications Minimum Burr

Case Study of Implantation of a VICI VENOUS STENT - Combined NIVL and PTS Stenting

Endovascular Repair o Abdominal. Aortic Aneurysms. Cesar E. Mendoza, M.D. Jackson Memorial Hospital Miami, Florida

MAXIMIZE RADIAL SOLUTIONS TO PERIPHERAL CHALLENGES

CLOSES WITH SECURITY. LEAVES WITHOUT A TRACE.

Transcription:

Quick Reference Guide

Indications for Use The AFX Endovascular AAA System is indicated for endovascular treatment in patients with AAA. The devices are indicated for patients with suitable aneurysm morphology for endovascular repair, including: Adequate iliac/femoral access compatible with the required delivery systems (diameter 6.5mm) Non-aneurysmal aortic neck between the renal arteries and the aneurysm With a length of 15mm With a diameter of 18mm and 32mm With neck angle of 60 to the body of the aneurysm Aortic length 1.0cm longer than the body portion of the chosen bifurcated model. Common iliac artery distal fixation site With a distal fixation length of 15mm With ability to preserve at least one hypogastric artery With a diameter of 10mm and 23mm With an iliac angle of 90 to the aortic bifurcation Extension stent grafts must have the ability to overlap the bifurcated stent graft by at least 30 to 40mm proximally and at least 15 to 20mm distally. Contraindications The AFX Endovascular AAA System is contraindicated in: Patients who have a condition that threatens to infect the stent graft. Patients with sensitivities or allergies to the device materials.

AFX System Components VELA Suprarenal Endograft VELA Infrarenal Endograft AFX Bifurcated Stent Graft Limb Extensions AFX System Components

Materials Required AFX2 Procedure: Materials Required ENDOLOGIX PRODUCTS * AFX Introducer System- S17-45 AFX 2 Bifurcated Delivery System- BEAXX-XX/IXX-XX VELA Suprarenal Endografts- AXX-XX/CXX-O20-V (as required) VELA Infrarenal Endografts- AXX-XX/CXX-V (as required) Limb extensions- ISXX-XX/CXX-SA or IXX-XX/CXX-F-SA (as required) Endovascular Snare 0.035 Stiff Wire EQUIPMENT Power injector Ultrasound (e.g. Sonosite) (optional) IVUS (optional) OR SUPPLIES Sheaths: 7F Contralateral 6-8F sheath for ipsilateral percutaneous access *All medical devices and tools are to be selected and utilized at the discretion of the medical professional. Additional Wires: 0.035 Standard Guidewire x2 0.035 Stiff Wire (e.g. Luderquist, Meier) Catheters: 0.035 compatible hard tip 5F angiographic pigtail catheter (adequate length) Exchange catheters (e.g. Berenstein, Kumpe, etc.) Balloons: Compliant Aortic balloon (e.g. Coda, Reliant, etc.) PTA balloons Other: Access needles Micro puncture Standard syringes Radiopaque contrast media Radiopaque (ruler) in millimeter increments Heparinized solution and sterile saline solution If Percutaneous: Ipsilateral pre-close device (Abbott Vascular, Inc. Perclose ProGlide closure device) Contralateral Doctor preference for 7F Sheath

Sterile Transfer: Best Practices Preloaded wire straightener Sterile tray Removal of sheathed wire from the tray Sterile transfer of device and sheathed wire with preloaded straightener Best Practice: Hold contralateral wire with both hands when removing device from tray. Sterile Transfer

System Set Up AFX System Set Up Do not apply excessive tension while withdrawing the contralateral wire, as this may lead to vessel and/or device damage. 1. System Set Up Flush side port and guidewire lumen. Position the AFX introducer and the 7F contralateral sheath in place. Position the snare wire above the bifurcation. Advance the AFX2 delivery system over the stiff guidewire and up to the hemostasis valve of the AFX introducer. Align the snareable tip of the contralateral wire with the end of the wire straightener. Refer to the IFU for full instructions. 2. Contralateral Wire Insertion As a unit, insert the wire with the straightener into the lumen of the AFX introducer and slightly tighten the hemostasis valve. Advance the contralateral wire into the AFX introducer, loosen the hemostasis valve and peel off the wire straightener. Best Practices: Always keep a hand on the wire while inserting into valve. Yellow portion of wire must enter wire straightener to create hemostasis. 3. Contralateral Wire Snaring While advancing the contralateral wire from the ipsilateral side, snare the floppy end of the wire at the aortic bifurcation. Withdraw the contralateral wire and snare out of the 7F contralateral sheath while simultaneously advancing the contralateral wire up the ipsilateral side. Advance the AFX2 delivery system until the handle docks into the hemostasis valve of the AFX introducer. Ensure the side port is pointing medially to maintain alignment of the contralateral limb. Best Practice: Upon snaring the contralateral wire, advance the wire up through the ipsilateral side and withdraw the wire out of the contralateral sheath at the same rate.

AFX System Set Up If anatomy is heavily calcified or tortuous, advance the entire system (AFX Introducer and AFX2 delivery catheter) into the aorta to avoid damage to the stent graft. Visually verify that the stent graft is seated on the aortic bifurcation, and that the proximal end is not covering the lowest renal artery. 4. Stent Graft Transfer Pin the AFX introducer handle and advance the inner core. Continue until the transfer stop is aligned with the device handle then remove the transfer stop. Advance the inner core in 50mm increments until the stent graft fully exits the end of the AFX introducer. Orient the contralateral limb by pinning the AFX introducer handle and rotating the inner core. Pin the AFX2 delivery system handle and gently pull down on the contralateral wire and inner core simultaneously to guide each limb into its respective iliac artery. Best Practices: Ensure delivery system remains parallel to direction of transfer. Once at the transfer stop pin the introducer sheath and inner core and twist to resolve wire orientation if misaligned. Use a dry sponge to enhance grip to aid in graft transfer. System Set Up

AFX2 Deployment AFX2 Deployment 1. AFX2 Main Body Deployment Hold the inner core Y-connector, and twist the control cord cap to disengage it. Slowly pull the cap to deploy the main body of the stent graft. Continue to pull on the control cord until the main body cover material exits through the Y-connector. If necessary, cap the port with a standard luer cap. The yellow marker on the control cord indicates that the main body cover is fully withdrawn into the inner core. 2. Contralateral Limb Deployment Hold the AFX2 delivery system steady by pinning the inner core. Slowly pull the yellow contralateral wire cover to deploy the contralateral limb. Continue pulling until the yellow contralateral wire cover is fully removed. Failure to pin the inner core during contralateral limb deployment may result in premature ipsilateral limb deployment. Benign deflection of the welded wire may occur upon limb deployment.

AFX2 Deployment 3. Contralateral Wire Release Advance a pigtail catheter over the contralateral wire until the tip is in contact with the wire lock. Advance the pigtail and wire together until an arch is formed above the wire lock. Hold the pigtail catheter in place and pull on the contralateral wire to release it from the wire lock. 4. Ipsilateral Limb Deployment Hold the AFX2 delivery system steady by pinning the device handle. Pull on the inner core slightly to deploy the ipsilateral limb inside the AFX introducer. Pin the inner core and retract the AFX introducer slightly to release the deployed ipsilateral limb. Best Practice: Pull on the inner core until the wire lock is just above the aortic bifurcation to deploy the ipsilateral limb inside the AFX Introducer sheath. AFX2 Deployment

AFX2 System Removal AFX2 System Removal Retract the inner core until it reaches a positive stop. Squeeze the handle snap cap to undock the AFX2 delivery system from the AFX introducer. Remove the AFX2 delivery system from the aortic guidewire. If resistance is encountered during withdrawal of the AFX2 delivery catheter through the bifurcated stent graft, rotate the inner core 90 degrees and proceed with withdrawal. Do not advance the inner core as this may disturb the bifurcated stent graft positioning.

AFX2 Troubleshooting Contralateral Wire Issue Lock Wire prematurely deploys Contralateral wire fails to release Solution Deploy the contralateral limb and re-cannulate through the deployed limb Retract the pigtail from the tip of the wire to the level of the bifurcation. Retract the inner core to deploy the ipsilateral limb while simultaneously retracting the contralateral until the locking mechanism is positioned above the bifurcation. Retract AFX Introducer to deploy limb before retracting system. While advancing the contralateral wire, continue retracting the inner core until the tip retracts into the AFX Introducer and a stop is felt. Detach the bifurcated delivery system from the AFX Introducer and disconnect the contralateral wire from the locking mechanism. Re-advance the pigtail catheter while ensuring proper cannulation of thebifurcated device and position at or above the renal arteries. AFX2 Troubleshooting

AFX2 Troubleshooting AFX2 Troubleshooting Tethering Issue Anchoring of the bifurcated device may be required if movement occurs during Aortic Extension System advancement. Solutions Position and inflate an appropriately sized PTA balloon, from the contralateral side, to anchor the AFX2 Bifurcated device, during advancement of the Aortic Extension. Depending on balloon size it may be necessary to use a contralateral sheath larger than 7F. The appropriate size PTA balloon should be based upon the diameter of the contralateral common iliac artery. CAUTION: If a balloon is used to stabilize the stent graft when introducing extension stent graft delivery catheter, care should be taken to avoid over-inflation of the balloon and/or disturbance of the bifurcated graft positioning. Do not exceed the manufacturer s recommended maximum balloon inflation diameter. Rupture of the balloon may occur. Adhere to balloon inflation parameters as described in this booklet. Over-inflation beyond the nominal diameter of the stent graft may result in damage to the vessel wall and/or vessel rupture, or damage to the stent graft. PTA Balloon Aortic Extension Best Practice: Determine whether balloon tethering may be required prior to the case. Should there be a likelihood balloon tethering will be required, have the appropriate aortic balloon size and model on hand.

AFX2 Troubleshooting Device Removal Issue Resistance is encountered during withdrawal of the AFX2 delivery catheter through the bifurcated stent graft. Solution Rotate the inner core 90 degrees to reposition the wing on the delivery system, and proceed with withdrawal. Control Cord Issue Control cord will not deploy the bifurcated main body. Solution Confirm the device is not deployed. Hold the AFX Introducer in place and start retracting inner core. This will restart the deployment of the graft by popping sutures as inner core passes through main body. DO NOT cut the control cord handle. AFX Graft Selection

AFX Graft Selection AFX Graft Selection Step 1 Choose Proximal Endograft Measure aortic neck diameter and renal to bifurcation distance to select the proximal aortic extension. Aortic Vessel Diameter (mm) Proximal Extension Diameter (mm) 18-23 25 20-26 28 23-32 34

AFX Graft Selection Step 2 Select Iliac Limb Dimensions Measure common iliac artery diameters and lengths to select iliac limb dimensions for the bifurcated stent graft.* Consider iliac extensions, if applicable (Step 4). Iliac Vessel Diameter (mm) Bifurcated Limb Diameter (mm) Available Limb Lengths (mm) 10-11 13 40 10-14 16 30, 40, 55 14-18 20 30, 40 *Limb lengths dependent on specific bifurcated device. See specifications under Model Numbers.

AFX Graft Selection Step 3 Select Bifurcated Stent Graft Use the renal to bifurcation length determined in Step 1 to choose the length of the main body. Ensure appropriate overlap with the proximal extension.** For main body diameter, use one diameter size smaller than the proximal aortic diameter. Proximal Endograft Diameter (mm) Main Body Diameter (mm) Main Body Lengths (mm) Proximal Endograft Covered Lengths (mm) 25 22 40, 60, 70, 80, 90 55, 75, 95 28 25 60, 70, 80, 90, 100, 110, 120 55, 75, 95 34 28 60, 70, 80, 90, 100, 110, 120 80, 100 **Extension stent grafts must have the ability to overlap the bifurcated stent graft by at least 30 to 40mm proximally and at least 15 to 20mm distally.

AFX Graft Selection Step 4 Choose Iliac Extensions, if applicable Ensure appropriate overlap with iliac limbs of the bifurcated stent graft.** Straight Proximal Diameter (mm) Distal Diameter (mm) Length (mm) 16 16 55 16 16 88 20 20 55 Shaped (Tapered or Stepped ) Proximal Diameter (mm) Distal Diameter (mm) Length (mm) 20 25 55 20 25 65 20 13 70 20 13 88 **Extension stent grafts must have the ability to overlap the bifurcated stent graft by at least 30 to 40mm proximally and at least 15 to 20mm distally. AFX Model Numbers

AFX Model Numbers AFX Model Numbers AFX 2 Bifurcated Stent Grafts Aortic Diameter Length Iliac Diameter Length Bifurcated Dimensions (mm) (mm) Dimensions (mm) (mm) BE A 22-40 / I 13 40 BE A 22-60 / I 13 40 BE A 22-60 / I 16 40 BE A 22-70 / I 16 30 BE A 22-70 / I 20 30 BE A 22-80 / I 16 40 BE A 22-80 / I 20 40 BE A 22-90 / I 16 30 BE A 22-90 / I 20 30 BE A 25-60 / I 16 40 BE A 25-70 / I 16 30 BE A 25-70 / I 20 30 BE A 25-80 / I 13 40 BE A 25-80 / I 16 40 BE A 25-80 / I 16 55 BE A 25-80 / I 20 40 BE A 25-90 / I 16 30 BE A 25-90 / I 20 30 Aortic Diameter Length Iliac Diameter Length Bifurcated Dimensions (mm) (mm) Dimensions (mm) (mm) BE A 25-100 / I 16 40 BE A 25-100 / I 20 40 BE A 25-110 / I 16 30 BE A 25-110 / I 20 30 BE A 25-120 / I 16 40 BE A 25-120 / I 20 40 BE A 28-60 / I 16 40 BE A 28-70 / I 16 30 BE A 28-70 / I 20 30 BE A 28-80 / I 16 40 BE A 28-80 / I 20 40 BE A 28-90 / I 16 30 BE A 28-90 / I 20 30 BE A 28-100 / I 16 40 BE A 28-100 / I 20 40 BE A 28-110 / I 16 30 BE A 28-110 / I 20 30 BE A 28-120 / I 16 40 BE A 28-120 / I 20 40

AFX Model Numbers VELA Suprarenal Endografts Proximal Distal VELA Aortic Diameter Diameter Length Length Radiopaque Dimensions (mm) (mm) Covered (mm) Open (mm) Marker A 25-25 / C 75 - O 20 V A 25-25 / C 95 - O 20 V A 28-28 / C 75 - O 20 V A 28-28 / C 95 - O 20 V A 34-34 / C 80 - O 20 V A 34-34 / C 100 - O 20 V VELA Infrarenal Endografts Proximal Distal VELA Aortic Diameter Diameter Length Radiopaque Dimensions (mm) (mm) Covered (mm) Marker A 25-25 / C 75 V A 25-25 / C 95 V A 28-28 / C 75 V A 28-28 / C 95 V A 34-34 / C 80 V A 34-34 / C 100 V Standard Infrarenal Aortic Extensions Proximal Distal Aortic Diameter Diameter Length Dimensions (mm) (mm) Covered (mm) A 25-25 / C 55 A 28-28 / C 55

AFX Model Numbers Flexible Limb Extensions Limb Extensions with Spine Proximal Distal Iliac Diameter Diameter Length Stand Dimensions (mm) (mm) Covered (mm) Design Alone I 16-16 / C 55 F SA I 20-13 / C 70 F SA I 20-13 / C 88 F SA I 20-20 / C 55 F SA Proximal Distal Iliac Diameter Diameter Length Stand Dimensions (mm) (mm) Covered (mm) Design Alone *Stepped I 16-16 / C 88 SA I S* 20-25 / C 55 SA I S* 20-25 / C 65 SA

www.endologix.com/contact INDICATIONS FOR USE: The Endologix AFX/AFX2 Endovascular AAA Systems are indicated for treatment of patients with abdominal aortic aneurysms having the vascular morphology suitable for endovascular repair using a surgical vascular access technique or a bilateral percutaneous technique; adequate iliac/femoral access compatible with the required delivery systems (diameter 6.5mm); a non-aneurysmal aortic neck between the renal arteries and the aneurysm: with length of 15mm, diameter 18 to 32mm and neck angle of 60 to the body of the aneurysm; aortic length 1.0cm longer than the body portion of the chosen bifurcated model; common iliac artery distal fixation site with length 15mm, diameter of 10 to 23mm, and with ability to preserve at least one hypogastric artery; and with an iliac angle of 90 to the aortic bifurcation. Extension stent grafts must have the ability to overlap the bifurcated stent graft by at least 30 to 40mm proximally and at least 15 to 20mm distally. CONTRAINDICATIONS: The Endologix AFX/AFX2 Endovascular AAA Systems are contraindicated for use in patents who have a condition that threatens to infect the graft and in patients with sensitivities or allergies to the device materials. Refer to the Instructions for Use for more information concerning Indications, Contraindications, Warnings and Precautions, and Adverse Events. CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician. NOTE: The AFX Endovascular AAA System and associated components are not available in all countries or regions. Please contact your Endologix representative for details regarding product availability. CE marked. Please refer to current product instructions for use. The ENDOLOGIX trademark is registered in the United States, European Community and Japan. The AFX trademark is registered in the United States, European Community and Argentina. Other foreign applications pending. 2016 Endologix Inc. All rights reserved. MM1103 Rev 01