HI Total Acidity Mini Titrator for Water Analysis

Similar documents
HI Total Alkalinity Mini Titrator for Water Analysis

HI Total Alkalinity Mini Titrator for Water Analysis

HI Titratable Acidity Mini Titrator for Fruit Juice Analysis

HI Titratable Acidity Mini Titrator for Fruit Juice Analysis

HI Titratable Acidity Mini Titrator for Fruit Juice Analysis

Measures 100 ppm to 100% water content. Precision titrant delivery system. Anti-diffusion burette tip. Built-in stirrer

HI FREE & TOTAL SULFUR DIOXIDE MINITITRATOR for wine analysis

Autotitrator. Technical Information and Specifications. mpt-2. detailed specification sheets from

Determination of Langelier Index in Water

PtPt-electrode with temperature sensor, Intellical MTC695

ph Electrodes with Bluetooth Smart Technology

Total Acid Number in petroleum products by automatic titration

Thiols (mercaptans) in Fuels (ASTM D )

Method (6 to 1000 µg/l Chlorine as Cl 2 ) Digital Titrator

Instruction Manual Updated 8/27/2013 Ver. 1.1

ebook Best practices using automated titrators Achieving speed and accuracy in your lab

EasyPlus Titration. Food & Beverage Analysis Made Easy Swiss Precision for Your Analysis

Pt-electrode with temperature sensor, Intellical MTC695

IP67 Waterproof. Food Quality ph Meters. Five models to measure the ph and temperature of food, milk, meat, yogurt and cheese.

Water Determination in Ethanol by Karl Fischer Titration

Free Chlorine. Based on 4500-Cl D. in Standard Methods for the Examination of Water and Wastewater DOC

QUICK START GUIDE HI 903 KARL FISCHER VOLUMETRIC TITRATOR. Revision 1.0

Determination of Total Hardness in Water by Automatic Titration

COLE-PARMER LABORATORY SURFACTANT ION ELECTRODE INSTRUCTION MANUAL

3 To gain experience monitoring a titration with a ph electrode and determining the equivalence point.

Free and Total Sulfur Dioxide (SO 2. ) in wine (Ripper method) by automatic titration

ph Technical Calibration Solutions solutions Technical Solutions (±0.01 ph) for Each Point of the ph Scale Easy to Use Single Dose Sachets

COLE-PARMER REPLACEABLE MEMBRANE SCIENTIFIC SURFACTANT ION ELECTRODES INSTRUCTION MANUAL

Application Note. Determination of the Acid Number (TAN) Tips and Tricks

Titration DL22 F&B Food & Beverage Analyzer

METTLER TOLEDO Titrators. 30 Selected Applications Application brochure 12

TRATION: ANALYSIS OF SODIUM HYDROXIDE

Dräger Alcotest 6820 Alcohol Screening Device

Determination of Chlorine Dioxide, Chlorite and Chlorine

TRATION: ANALYSIS OF SODIUM HYDROXIDE

DROP TEST TOTAL HARDNESS (1 drop = 10 ppm)

ramé-hart Model 90 Goniometer / Tensiometer

Solutions for Calibration and Maintenance

DROP TEST P/M & P/T ALKALINITY (1 drop = 10 ppm)

Hardness, Total, Sequential

TECHNOCARE MEDISYSTEMS

888/890 Enter the Titrando world

Experiment 3. Potentiometric Titration Using a ph Electrode. information necessary for both purposes by monitoring the ph of the solution as the

Hardness (Total & Calcium) Test Kit TK4040-Z 1 drop = 2 or 10 ppm as CaCO 3

Dräger Alcotest 5510 Alcohol Screening Device

Detection. personal. Now, you can optimize your personal workflow. Promega instruments and reagents integrate easily.

Determination of the acid value (AV) Application Bulletin 200/3 e. Electrodes Solvotrode easyclean

Radnoti Langendorff Constant Pressure Non-Recirculating Pump Driven Isolated Heart System For Mouse EZ

25-Hydroxyvitamin D2-D3 Serum VD-200 UHPLC Analysis Kit User Manual

Dear HighQ Check System Owner :

Omnitest : 2013

Parts and Consumables. Sciclone ALH 3000 and Zephyr Liquid Handlers

SURETEST Torque Calibration System

Application Note No. 107/2013 Nitrogen & protein determination in beer and malt KjelDigester K-449, KjelMaster K-375 with KjelSampler K-376:

Acetic Acid in Vinegar by Acid/Base Titration

Application Note No. 113/2013 Nitrogen & protein determination in dry pet food KjelDigester K-449, KjelMaster K-375 with KjelSampler K-376:

Strength of Vinegar by Acid-Base Titration

Technical Data Sheet SONOFLOW CO.55 V1.0

Take an initial volume reading and record it in your. 11/17/2014 ChemLab - Techniques - Titration

With extended functionality the sensors are also applicable for the detection of air bubbles.

E55A GELATIN, GELLING GRADE Gelatina

microprocessor controlled eddy current brake Load / accuracy Watt, speed independent / according to DIN VDE

SURETEST Torque Calibration System

Dräger Alcotest Handheld Product Suite

White Paper. Thermometric Titration of Acid Number According to ASTM D8045

TABLE OF CONTENTS 1.1. WARRANTY DAMAGED SHIPMENTS SERVICE INTRODUCTION UNPACKING AND INSTALLATION

ECHOLAB. Screening and Clinical Modality. User Programmable Protocols. Otoacoustic Emissions System TEOAE - DPOAE - ABR - AABR

Advanced in vitro exposure systems VITROCELL VC 1 SMOKING MACHINE

There are many varieties of particulate pollutants in our homes and offices. Ones from outside include industrial

RaySafe i3 INSTALLATION & SERVICE MANUAL

Elcometer 138/2. Surface Contamination Kit. Operating Instructions

Analysis of Micronutrients in Milk by Flame Atomic Absorption Using FAST Flame Sample Automation for Increased Sample Throughput

THS74/75 Industrial Temperature & Humidity Transmitter. Operation Manual

Gymna ShockMaster 500

MINISTAR DIGITAL AND CONTROL /// The new compact stirrers

DROP TEST P/M & P/T ALKALINITY (1 drop = 10 ppm)

Vitamin A-E Serum HPLC Analysis Kit

A new experience of speed

Hardness by EDTA Titration

25-Hydroxyvitamin D2-D3 Serum LC-MS/MS APCI Analysis Kit User Manual

Titrimetric Determination of Hypo Index, Thiosulfate, and Sulfite in EASTMAN Color Films, Process ECN-2 Fixer

2017 SPERM QUALITY ANALYZERS FOR VETERINARY / BREEDING MES CATALOGUE

Electrotherapy, ultrasound therapy, combined therapy, laser therapy and magnetotherapy Etius ULM

Quantitative Measurement of Emergency Biomarkers in Parallel

Glucose analyser GA 3

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems

Advanced in vitro exposure systems

Evolve 3 & 5 Service Manual

Determination of the total acid number in petroleum products

RLS /M MX SERIES

When worker safety is mission critical. Thermo Scientific EPD TruDose Electronic Dosimeter

Application Bulletin

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

BC380. The New Standard in Body Composition Analysis BODY COMPOSITION ANALYZER

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor

Frequently Asked Questions

PROCEDURE. TITLE: Bedside Glucose Monitoring PC Laboratory. Issuing Department: Clinical Director Signature: Departments Involved:

REEF CARE PROGRAM / Reef Colors. Reef Foundation. Testing and Supplementing

Automated Blood Pressure Monitor

DC Unbalance Tolerance Testing in PSE s

Transcription:

HI 84530 Total Acidity Mini Titrator for Water Analysis

Piston Driven Pump with Dynamic Dosing The HI 84530 incorporates dynamic dosing to provide precison titrant delivery. Dynamic dosing adjusts the amount of titrant dosed as the end point is approached for increased accuracy in endpoint detection. Piston Burette Piston burettes provide an exceptionally reliable titrant delivery. This highly accurate dosing method is attained by combining a pulse controlled step motor with a 5 ml polypropylene syringe. The rigid and stable body of our syringe allows for less frequent pump calibration. Users no longer have to account for the changing elasticity of tubing associated with peristaltic pumps. More About Dynamic Dosing With the integration of our piston burette, our titrator can adjust the volume and frequency of titrant dosed based on relative mv changes in the testing solution. This titrant delivery system is known as dynamic dosing, where titrant is delivered in larger doses at the start of the titration and smaller doses near the end point. These differences in dosing volume and frequency result in a faster titration without sacrificing accuracy. With larger doses in the beginning of the titration, the speed of the titration is increased, where smaller doses near the end point allow for more time for the titrant and analyte to react. Smaller doses also prevent the over titration of a sample and a more accurate determination of titrant volume used. ph Electrode The HI 84530 is supplied with the HI 1131B refillable, double junction, combination ph electrode. By design, the HI 1131B has a spherical tip for use in aqueous or liquid solutions. This versatile electrode provides a wide surface of contact with a sample and is ideal for any general acid/base titration in the water industry.

HI 84530 Mini Titrator for Water Applications Piston Driven pump with Dynamic Dosing This piston driven dosing pump incorporates dynamic dosing to provide highly accurate, repeatable results. CAL CHECK CAL CHECK alerts users to potential problems during calibration such as contaminated buffers or dirty/broken electrodes. ph/mv M eter In addition to automatic titration, the HI 84530 can also be used as a ph/mv meter. Log-on-Demand Log data up to 400 samples (200 for titration; 200 for ph/mv). Graphic Mode/Exportable Data Displays in-depth data on titration, which can then be stored and exported to either a USB drive or PC using the USB connection. Automatic Stirrer Speed Control Maintains stirrer speed at approximately 600 rpm regardless of viscosity of solution. GLP Feature The HI 84530 includes a GLP Feature that allows users to view calibration data for the ph electrode and dosing pump. Easy to use interface User intuitive design with large keys and easy to navigate screens. ph Electrode The HI 84530 is supplied with the HI 1131B ph electrode. This versatile electrode can be used in all types of water.

Easy to Use, Fast and Affordable All-in-one Solution The HI 84530 is an easy to use, fast and affordable mini automatic titrator with a ph meter designed for the rapid and accurate analysis of Total Titratable and Strong Acidity in water. This new generation of mini automatic titrator improves upon the titrant delivery system and measuring ranges for increased accuracy compared to previous models. This meter reflects Hanna s years of experience as a manufacturer of analytical instruments. The HI 84530 incorporates a precise piston dosing system, which allows for a highly accurate determination of the amount of titrant used. It is also capable of dynamic dosing, making testing both faster and more accurate. Pump calibrations are performed with the provided Hanna standard, help assure the accuracy of the measurement. An intuitive interface makes the instrument simple to use and the dedicated HELP key guides the user through set-up, calibration status, and troubleshooting. This mini titrator includes a pre-programmed analysis method based on the Standard Methods of Water and Wastewater Determination. It uses a powerful algorithm which analyzes the shape of the electrode response in order to determine when the titration reaction has reached completion. This mini-titrator is also designed to be used as a benchtop ph/mv meter. As a ph meter, it has many features of a professional grade benchtop including automatic calibration up to 3 points with 4 available buffers, a 0.01 ph resolution, accuracy of +/- 0.01 ph, automatic temperature compensation and comprehensive GLP Data. The GLP data includes date, time, offset, slope, and buffers used for calibration. Accuracy is always ensured with Hanna s unique Cal-Check feature, which analyzes the response of the electrode during the calibration process. Based on electrode response in the buffer, indicators are displayed on screen to alert the user of potential problems during calibration. These indicators include Buffer Contaminated, Electrode Dirty/Broken, and overall probe condition as a percentage that is based on both the offset and slope characteristic of the electrode. The Cal-Check function not only ensures an accurate ph reading when the HI 84530 is used as a ph meter but also an accurate titration since the end point is determined by a set ph value. Why Titratable Total Acidity is So Important Acidity is a quantitative measurement of the water sample s ability to react with a strong base solution to a specific ph value. Many chemical species can contribute to the acidity measurement depending on the method of analysis. These species can include strong acids (hydrochloric acid, nitric acid, sulfuric acid, etc.), weak acids (acetic acid, carbonic acid, etc.), and hydrolyzing salts (iron, aluminum, manganese, etc.). Acidity is an important parameter used to determine the quality of water (surface, drinking, wastewater). It is an essential monitoring device to define and control the pollution levels. Acidity effects many things including chemical reaction rates, biological processes, and corrosiveness. All-in-One Water Titrator, ph Meter, Electrode and Magnetic Stirrer in one package

Features Setup Screens Tutorial and HELP Screens The LCD features an easy to use setup screen that allows the user to change measuring range, time, date, language and more. Accessing the tutorial menu provides helpful information during calibration and titration. Rear USB Outputs For PC connection and to export data to a USB drive 1 5 2 6 7 3 CAL CHECK Titration Curve Displayed On Screen CAL CHECK is a Hanna exclusive process for checking the condition of electrodes which helps keep measurements accurate. The HI 84530 offers real time graphing of the titration curve on the LCD. 8 4 Display 1) Current time and instrument mode information (ph meter or Titrator) 2) Procedural indicators 3) Instrument status 4) Virtual option keys 5) Stirrer and icon status GLP Log and Recall data The GLP feature records electrode and pump calibration data to help keep measurements accurate and reliable. The HI 84530 can log up to 400 samples (200 for titration results; 200 for mv/ph) and recall or export data to a USB stick or PC. During the instrument s operation a set of information are displayed on the LCD. Displayed icons: Stirrer on Procedure Warnings Adjustable Backlit LCD Users are warned if there is an error in procedures such as the use of a wrong buffer. The HI 84530 offers a backlit LCD with adjustable brightness levels. This ensures that the LCD is always easy to read. Pump running Stirrer is not working properly Wait for stable reading Parameter can be modified 6) Main reading information 7) ph temperature compensation mode (Manual or Automatic) 8) Temperature reading

Specifications HI 84530 - Total Acidity Accessories Titrator Accuracy (@25ºC/77ºF) Method Principle Pump speed Stirring Speed Logging Data ph Meter Accuracy (@25ºC/77ºF) Low : 15.0-400.0 mg/l (ppm) as CaCO 3 meq/l: 0.3-8.0 meq/l as CaCO 3 High : 300-4000 mg/l (ppm) as CaCO 3 meq/l: 6.0-80.0 meq/l as CaCO 3 Low : 0.1 mg/l / 0.1 meq/l High : 1 mg/l / 0.1 meq/l Low : ± 1 ppm or 3% of reading, whichever is greater High : ± 15 ppm or 3% of reading, whichever is greater acid-base titration - total acidity (phenolphthalein) / strong acidity (Methyl Orange) end point titration : 8.30 ph / 3.7 ph 10 ml/min 600 rpm up to 200 samples -2.0 to 16.0 ph / -2.00 to 16.00 ph 0.1 ph / 0.01 ph ±0.01 ph Calibration 1, 2 or 3 calibration points; 4 available buffers (4.01, 7.01, 8.30, 10.01) Temperature Compensation Logging Data mv Meter Accuracy Logged Data Temperature Accuracy Additional Specifications ph Electrode Temperature Probe Environment Power Supply manual or automatic from -20 to 120 C (-4 to 248 F) Up to 200 samples (ph or mv) -2000.0 to 2000.0 mv 0.1 mv ± 1.0 mv Up to 200 samples (ph or mv) -20.0 to 120.0 C (-4.0 to 248.0 F) 0.1 C ±0.4 C without probe error HI 1131B glass body, refillable, with BNC connector and 1 m (3.3 ) cable (included) HI 7662-T stainless steel temperature probe with 1 m (3.3 ) cable (included) 0 to 50 C (32 to 122 F); RH max 95% non-condensing 12 VDC adapter (included) Dimensions 235 x 200 x 150 mm (9.2 x 7.9 x 5.9 ) Weight 1.9 kg (67.0 oz.) Reagents HI 84530-50 Titrant solution for Low (100 ml) HI 84530-51 HI 84530-55 Titrant solution for High (100 ml) Calibration Standard (100 ml) HI 84530-60 Hydrogen Peroxide (30 ml) ph Calibration Solutions HI 7004M HI 7007M HI 70083M HI 7010M Buffer solution ph 4.01 (230 ml) Buffer solution ph 7.01 (230 ml) Buffer solution ph 8.30 (230 ml) Buffer solution ph 10.01 (230mL) Electrode Fill and Storage Solutions HI 7082 HI 70300L Electrode fill solution (4 x 30 ml) Electrode storage solution (500 ml) Electrode Cleaning Solution HI 7061M Electrodes HI 1131B HI 7662-T Electrode Cleaning Solution (230 ml) ph Electrode Other Accessories HI 70500 HI 71005/8 HI 71006/8 HI 731319 HI 740036P HI 740236 HI 920013 Temperature probe Tube set with cap for titrant bottle, tip and valve 115 Vac to 12 Vdc, 800 ma 230 Vac to 12 Vdc, 800 ma Stir bar, 25 x 7 mm (10 pcs.) 100 ml Beaker (10 pcs.) 5 ml Syringe for minititrator PC Connection Cable Ordering Information HI 84530-01 (115V) and HI 84530-02 (230V) are supplied with: HI 84530-70 Reagent Kit for Water Analysis HI 1131B ph electrode HI 7662-T temperature probe HI 740036P Two 100 ml beakers HI 70500 Tube set (aspiration tube with titrant bottle cap and dispensing tube with tip), Dosing Pump Valve HI 740236 5 ml Syringe 1 ml plastic pipette HI 731319 stir bar HI 920013 power adapter Instruction manual and quality certificate