AcUMEDr. LoCKING CLAVICLE PLATE SYSTEM

Similar documents
AcUMEDr. Locking Proximal Humeral Plate. PoLARUSr PHPt

Locking Clavicle Plating System. Surgical Technique

Clavicle Plating System Acu-Sinch Repair System. Surgical Technique

Clavicle CORE Plating System Surgical Technique

Locking Radial Head Plates

AcUMEDr. Anatomic Midshaft Forearm Plates

WINSTA-C. Clavicle Plating System

AcUMEDr. Olecranon Threaded Compression Rod

Locking Ankle Plating System. Surgical Technique

AcUMEDr. FoREARM ROD SYSTEM

Surgical Technique International Version. Clavicle Locking Plate

Osteotomy System. The reference lines on the plate help facilitate the creation of the osteotomy, when a free hand cut is preferred.

Acu-Loc Wrist Spanning Plate System. Surgical Technique

Surgical Technique. Clavicle Locking Plate

Surgical Technique. Proximal Humerus Locking Plate

Forearm Fracture Solutions. Product Overview

Fibula Rod System. Lateral Malleolus Fracture Indications:

Acu-Sinch Repair System. Technical Monograph

Zimmer Small Fragment Universal Locking System. Surgical Technique

Acu-Loc Wrist Plating System. Surgical Technique

Osteotomy System. Surgical Technique

Technique Guide. LCP Proximal Femoral Hook Plate 4.5/5.0. Part of the LCP Periarticular Plating System.

SMV Scientific Bone Plate and Screw System Surgical Technique

Surgical Technique. Olecranon Locking Plate

Mayo Clinic Congruent Elbow Plate System

Elbow Plating System

TABLE OF CONTENTS. 2 (8144 Rev 2)

Surgical Technique. Ankle Plating System

Surgical Technique. Elbow Plating System

PediLoc 3.5mm and 4.5mm Contour Femur Plate Surgical Technique

Forearm Fracture Solutions. Surgical Technique

VA-LCP Anterior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

Surgical Technique. Targeter Systems Overview

Percutaneous Scaphoid Fixation: A Volar Approach

Instrument and Implant for wrist fracture

The Flower Straight Fibula Plate

Percutaneous Humeral Fracture Repair Surgical Technique

LoCKING FOREFOOT/ MIDFOOT PLATES

Surgical Technique. CONQUEST FN Femoral Neck Fracture System

MetaFix Ludloff Plate

modular ClaVICle PlaTe system

3.5 MM VA-LCP PROXIMAL TIBIA PLATE SYSTEM

Conventus CAGE PH Surgical Techniques

Technique Guide. 3.5 mm LCP Periarticular Proximal Humerus Plate. Part of the Synthes locking compression plate (LCP) system.

The Flower Proximal Humerus Plate

Surgical Technique. Fibula Rod System

Technique Guide. 3.5 mm LCP Olecranon Plates. Part of the Synthes locking compression plate (LCP) system.

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

Humeral SuturePlate. Surgical Technique

Surgical Technique. Calcaneal Locking Plate

Surgical Technique. Distal Humerus Locking Plate

Locking Forefoot/Midfoot Plating System

3.5 mm LCP Superior and Superior Anterior Clavicle Plates. Part of the Synthes modular clavicle plate system.

Elbow Plating System. Surgical Technique

PediLoc 3.5mm and 4.5mm Bowed Femur Plate Surgical Technique

Forefoot/Midfoot Plating System. Surgical Technique

Surgical Technique Guide

LCP Superior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plate Aiming Instruments. Part of the 3.5 mm LCP Percutaneous Instrument System.

OptiLock Periarticular Plating System For Distal Tibial Fractures. Surgical Technique

3.5 mm LCP Clavicle Hook Plates

Surgical Technique. Forearm Fracture Solutions

Technique Guide. 2.7 mm/3.5 mm LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system.

Olecranon Locking Plate II

Forefoot/Midfoot Plating System

Distal Radius Plate Instrument and Implant Set. Discontinued December 2017 DSUS/TRM/0916/1063(1)

Biomet Large Cannulated Screw System

3. PATIENT POSITIONING & FRACTURE REDUCTION 3 8. DISTAL GUIDED LOCKING FOR PROXIMAL NAIL PROXIMAL LOCKING FOR LONG NAIL 13

Merete PlantarMAX Lapidus Plate Surgical Technique. Description of Plate

Hand Fracture System with Small Bone External Fixation System. Product Overview

Clavicle Hook Locking Plate

Small Fragment Plating System. Securing optimal fixation through locked and compression plating technology

LCP Periprosthetic System. Part of the Synthes locking compression plate (LCP) system.

AcUMEDr. AcUTRAKr. Headless Compression Screw

3.5 mm LCP Low Bend Medial Distal Tibia Plate Aiming Instruments

Small Fragment Plating System

Technique Guide. 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

Technique Guide. Compact 2.0 LOCK Mandible. The locking system for the mandible.

2.7 mm/3.5 mm VA-LCP Anterior Clavicle Plates. Part of the Synthes modular clavicle plate system.

AcUMEDr. ScAPHOID TARGETING GUIDE

System. Humeral Nail. Surgical Technique

Hand Fracture System. Surgical Technique

3.5 mm LCP Olecranon Plates

Clavicle Fracture Solutions Value Analysis Committee - Resource Guide

Wright Medical Technology, Inc Cherry Road Memphis, TN

Zimmer Small Fragment Universal Locking System

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system.

The Flower Forefoot PROCEDURE GUIDE.

Open reduction; plate fixation 1 Principles

3.5 mm LCP Superior Anterior Clavicle Plates

Surgical Technique. Cannulated Angled Blade Plate 3.5 and 4.5, 90

Cannulated Angled Blade Plate 3.5 and 4.5, 90.

LCP Distal Humerus Plates

Humerus shaft - Reduction & Fixation - Compression plate - AO Surgery Reference. Compression plating

A locking plate system that expands a surgeon s options in trauma surgery. Zimmer NCB Plating System

2.7 mm/3.5 mm LCP Distal Fibula Plate System. Part of the Synthes locking compression plate (LCP) system.

tep Ankle Fracture Plating System

LCP Superior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

Transcription:

AcUMEDr LoCKING CLAVICLE PLATE SYSTEM

LoCKING CLAVICLE PLATE SYSTEM Since 1988 Acumed has been designing solutions to the demanding situations facing orthopedic surgeons, hospitals and their patients. Our strategy has been to know the indication, design a solution to fit, and deliver quality products and instruments. Acumed s Locking Clavicle Plates are designed to provide excellent fixation for acute fractures, malunions, and non-unions of the clavicle. While often treated conservatively, a portion of these fractures can benefit from a low profile, congruent, locking plate. Soft tissue irritation is minimized, and patient function improves while returning them to their normal activities sooner. Closed Treatment of Displaced Middle-Third Fractures of the Clavicle Gives Poor Results. 1 The results of the 52 cases studied with an average follow-up of 38 months: 15% nonunion rate 25% pain requiring NSAID's 36% difficulty lifting 20lb overhead 39% tenderness at fracture site 31% signs of nerve compression 31% were dissatisfied with the result "We now recommend open reduction and internal fixation of severely displaced fractures of the middle third of the clavicle in adult patients" With the Locking Clavicle Plates, Acumed has designed a comprehensive solution for repairing fractures located from the middle third to the distal third of the clavicle. Standard ORIF procedures for clavicle fractures including, pinning, reconstruction, and DC plating have historically provided less than desirable results. 2 Traditional hardware frequently causes soft tissue irritation and/or fails prior to union, requiring a second procedure. Designed in conjunction with William Geissler, MD, the Locking Clavicle Plate offers a low profile solution for superior plating of the clavicle. Pre-contoured to match the natural S-shape of the clavicle, this titanium plate offers increased strength, with a rounded profile and a low-profile screw-plate interface. This design not only reduces OR time spent in contouring a plate but also minimizes soft-tissue irritation for the patient. The Locking Clavicle Plates are included in a comprehensive system of implants and instrumentation specifically designed to treat clavicle injuries. Acumed s locking instrumentation provides a quick, straightforward means of inserting the locking screws with accurate precision each and every time. 2

Precontoured Plate Geometry matches the anatomy of the patient with little or no bending. The Locking Clavicle Plate may also act as guide or template for restoring the patient's original anatomy when reconstructing a malunion, nonunion, or a highly comminuted fracture, unlike intramedullary rods/pins or straight plates. Superior Biomechanical Stability is engineered into both the design of the plates and their orientation on the clavicle. Yield Strength 87.5 Stress: Clavicle Plate Plating the superior aspect of the clavicle has been found to be biomechanically the most stable 3. Acumed in house analysis showed that when subjected to equal force, a 3.5mm N 26 Recon Plate 87.5 N SS reconstruction plate broke in multiple locations while Acumed s clavicle plate suffered no permanent deformation 4. Recon Plate Clavicle Plate low 87.5 N failure Multiple Plate Options are available to fit a wide variety of clavicle curvatures. For central one-third applications, there are five different lengths and curvatures in both left (blue) and right (green), and for distal/lateral fractures two specialized J plates are available. Color coded for left (blue) and right (green) application. Laser marked for proper orientation. Low profile plate/screw interface. Locking holes. Anterior surface is rounded to minimize irritation. All plates have a combination of locking holes and compression slots for maximum fixation. Standard compression/ reduction slots. 1) Hill et al, J Bone Joint Surg (Br.) 1997;79-B:537-539 2) Bostman et al, J Trauma: Injury, Infection, and Critical Care. 1997; 5:778-783 3) Iannotti, et, al, JSES, Sept/Oct 2002 4) Data on file at Acumed Larger compression/ reduction slots. Undersurface is tubularized for additional stability, especially in torsion. Beveled medial and lateral profile to minimize irritation. 3

SURGICAL TECHNIQUE By William Geissler, M.D. This section offers Acumed s suggested method for implanting the Locking Clavicle Plate. For specific questions not addressed here, please contact your local Acumed representative or Acumed at 888 627-9957. Step 2: Exposure Step 1: Patient Positioning The patient is initially placed in the beach chair position. A bolster is placed between the shoulder blades to help facilitate reduction of the fracture during the case. The patient's involved upper extremity is prepped and draped in a sterile fashion allowing the arm to be manipulated to help further reduce the fracture if required. Approximately a six cm transverse (medial to lateral) incision is made over the palpable fracture of the clavicle, usually in the middle third. The medial fragment is usually proximal in relation to the distal fragment.the incision is usually placed midway between the proximal/distal migration of the proximal fragments. Dissection is carried down to the fascia and the skin flaps are elevated. The cutaneous nerves are protected. The musculature is then subperosteally elevated off the bone fragments. It is important to keep soft tissue attachments to the butterfly fragments in an attempt to maintain vascularity. The fracture is reduced. Step 3: Plate Selection Step 4: Plate Placement The appropriately sized left or right clavicle plate is selected from the five different lengths and curvatures in the system. Usually the larger plates are ideal for most males, the medium plates for smaller males and most females, and the smallest plates for the smallest patients. The two middle slots may be placed over the fracture, ideally leaving two to three locking and/or non-locking holes both proximal and distal to the fracture fragments; however, the plate can be slid medially or laterally for the most ideal location. In cases of non-union or malunion, the curve of the plate can assist in anatomic reduction of the clavicle, reducing strain on the sternoclavicular and acromioclavicular joints. NOTE: Lag screw fixation across the major fracture fragment may be performed prior to placement of the plate. After the near cortex is drilled with the 3.5mm drill (MS-DC35), the 2.8/3.5mm drill sleeve (MS-DS2835) is inserted and the far cortex is drilled with a 2.8mm drill (MS-DC28). Once the plate's ideal positioning has been selected, it is provisionally stabilized to the clavicle with bone clamps (PL-CL04). The non-locking screws may be placed either unicortical or bicortical. If bicortical screws are used, it is important to not over-penetrate the distal cortex and potentially risk neurovascular injury. A curved retractor (PL-CL03) or other means of protection should be placed under the inferior surface of the clavicle to protect the neurovascular structures from over-penetration of the drill bit. NOTE:The plate may be rotated 180 for a more anatomical fit on fractures that are more lateral than the central 1/3. A plate of the opposite dexterity may also be used if the patient s anatomy requires a different curvature than that provided with the correct-sided plate. 4

Step 5: Non-Locking Screw Insertion Step 6: Locking Screw Insertion For early stability, the first two screws placed should be medial and lateral to the fracture site. Although 3.5mm screws (CO-3XX0) are recommended, optional 2.7mm (CO-27XX) and 4.0mm (CA-4XX0) screws are available upon request. Assemble the driver handle (MS-3200 or MS-1210) to the driver tip (HPC-0025 or HT-2502). Using the appropriate drill size (MS-DC28 or MS-DC5020) and the offset drill guide (PL-2095), drill, measure for depth (MS-9022) and place the screws into the slots with the assembled driver. Once the two screws are installed, the bone clamps (PL-CL04) holding the plate to the clavicle may be removed. Using the locking drill guide (MS-LDG35) and the 2.8mm drill (MS-DC28), place the 3.5mm locking screws (COL- 3XX0) into the threaded holes so that there are at least three screws (if possible) on each side of the fracture. NOTE:The bolster may be temporarily removed or the long driver tip (HT-2502) may be used if the patient's head is in the way during drilling and insertion of the screws. Once the screws are placed, the bolster may be replaced. Tapping (MS-LTT35 or MS-LTT27) is recommended for patients with dense bone. The drill guide (MS-LDG35) must be removed prior to tapping. NOTE:The drill (MS-DC28 or MS-DC5020) will need to be replaced if it comes in contact with the retractor. Step 7: Final Plate and Screw Position An intraoperative radiograph is recommended to check the position of the screws and the final reduction of the fracture. If the surgeon feels the bone quality of the lateral fragment is poor, sutures may be passed from medial to lateral around the coracoid process and the plate to take stress off of the lateral fixation. The musculature is then re-approximated directly over the plate. The skin is then closed in layers with a subcuticular stitch for the remaining skin layer. Post-op Protocol The patient is placed in an arm sling and starts pendulum range of motion exercises. Passive motion exercises are initiated from the first four weeks, active assisted from four to six weeks, and active strengthening is initiated at six weeks post operatively, once healing is seen radiographically. 5

J-PLATE SURGICAL TECHNIQUE By William Geissler, M.D. This section offers Acumed s suggested method for implanting the Congruent Clavicle Plate. For specific questions not addressed here, please contact your local Acumed representative or Acumed at 888 627-9957. Step 1: Exposure Step 2: Plate Placement Approximately a six cm transverse (medial to lateral) incision is made over the palpable distal third fracture of the clavicle. The exposure is made using the same method described in the previous surgical technique. The fracture is reduced and the appropriate plate is selected. Lag screw fixation across the major fracture fragment may be performed prior to placement of the plate. After the near cortex is drilled with the 3.5mm drill (MS-DC35), the 2.8/3.5mm drill sleeve (MS-DS2835) is inserted and the far cortex is drilled with a 2.8mm drill (MS-DC28). Once the plate's ideal positioning has been selected, it is provisionally stabilized to the clavicle with bone clamps (PL-CL04). The non-locking screws may be placed either unicortical or bicortical. If bicortical screws are used, it is important to not over-penetrate the distal cortex and potentially risk neurovascular injury. A curved retractor (PL-CL03) or other means of protection should be placed under the inferior surface of the clavicle to protect the neurovascular structures from over-penetration of the drill bit. Step 3: Non-Locking Screw Insertion Step 4: Locking Screw Insertion For early stability, the first two screws placed should be medial and lateral to the fracture site. Although 3.5mm screws (CO- 3XX0) are recommended, optional 2.7mm (CO-27XX) and 4.0mm (CA-4XX0) screws are available upon request. Assemble the driver handle (MS-3200 or MS-1210) to the driver tip (HPC-0025 or HT-2502). Using the appropriate drill size (MS-DC28 or MS-DC5020) and the offset drill guide (PL- 2095) drill, measure for depth (MS-9022) and place the screws into the slots with the assembled driver. Once the two screws are installed, the bone clamps (PL-CL04) holding the plate to the clavicle may be removed. NOTE:The drill (MS-DC28 or MS-DC5020) will need to be replaced if it comes in contact with the retractor. Using the locking drill guide (MS-LDG35) and the 2.8mm drill (MS-DC28), place the 3.5mm locking screws (COL-3XX0) into the threaded holes so that there are at least three screws on each side of the fracture. NOTE:The bolster may be temporarily removed or the long driver tip (HT-2502) may be used if the patient's head is in the way during drilling and insertion of the screws. Once the screws are placed, the bolster may be replaced. Tapping (MS- LTT35 or MS-LTT27) is recommended for patients with dense bone. The drill guide (MS-LDG35) must be removed prior to tapping. 6

Step 5: Final Plate and Screw Position An intraoperative radiograph is recommended to check the position of the screws and the final reduction of the fracture. If the surgeon feels the bone quality of the lateral fragment is poor, sutures may be passed from medial to lateral around the coracoid process and the plate to take stress off of the lateral fixation. The musculature is then re-approximated directly over the plate. The skin is then closed in layers with a subcuticular stitch for the remaining skin layer. Exposure Locking Drill Guide Final Fixation Post-op Protocol The patient is placed in an arm sling and starts pendulum range of motion exercises. Passive motion exercises are initiated from the first four weeks, active assisted from four to six weeks, and active strengthening is initiated at six weeks post operatively, once healing is seen radiographically. Minimal Scarring 7

AcUMEDr 5885 NW Cornelius Pass Road Hillsboro, OR 97124 888 627-9957 www.acumed.net Distributed by: Patent pending. CPS00-07-00 Effective: 07/2005