RD180 SP TECHNOLOGY GUIDE READ THIS PRODUCT INSERT THOROUGHLY BEFORE USE

Similar documents
Single Use Curlew TM Multiple Biopsy Forceps

The Ceterix NovoStitch Disposable Suture Passer. Do Not Reuse

Visit Linvatec.com today to learn more. Surgical Technique: Sequential Meniscal Running Stitch

Doc no: IFU/CPL Issue date: Rev no: 00 Rev date: 1

Initial placement 24FR Pull PEG kit REORDER NO:

Device Preparation (all steps to be performed per standard interventional technique)

Doc no: IFU/CC Issue date: Rev no: 04 Rev date:

Initial placement 20FR Guidewire PEG kit REORDER NO:

Technique Guide KISSloc Suture System

Technique Guide. *smith&nephew SPEEDSCREW Fully Threaded Knotless Implant

CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE

Technique Guide. *smith&nephew MAGNUM 2 Knotless Implant

Pinit Plate Small Bone Fusion System Bone Plate & Screw System

Passer. Sterile. D i. Do Not PASSER DESCRIPTION. The Ceterix. Page 1

Technique Guide Small Bone Fusion System

GENERAL TECHNIQUE GUIDE

EndoRelease ENDOSCOPIC CUBITAL TUNNEL RELEASE SYSTEM

Surgical Protocol written by Keith Lawhorn, M.D.

CHANGING THE WAY YOU LOOK AT THINGS

Arthroscopic Shoulder Repair Using the Smith & Nephew KINSA Suture Anchor

Instructions for Use Reprocessed Ethicon ENDOPATH XCEL TM Bladeless Trocar with OPTIVIEW Technology

Peel-Apart Percutaneous Introducer Kits for

Instructions for Use Reprocessed ENDOPATH XCEL Bladeless Endoscopic Trocars and Cannulas. Reprocessed Device for Single Use.

Echo PS Positioning System with Ventralight ST Mesh or Composix L/P Mesh

Look For These Other Products by PARÉ Surgical, Inc. INNOVATIVE MEDICAL DEVICES

Cardiva Catalyst III INSTRUCTIONS FOR USE

Duracryl sutures should be selected and implanted depending on the patient condition, surgical experience, suturing technique and wound size.

OR Configuration, Port Placement and Docking

Bard CapSure. Technique Guide. Permanent Fixation System SOFT TISSUE REPAIR. Laparoscopic Inguinal, Open and Laparoscopic Ventral Hernia Repair

RAPIDSORB RAPID ReSORBABLe CRANIAL CLAMP

ER REBOA Catheter. Instructions for Use

Ponsky * PEG Safety System - "Pull" Bard * PEG Safety System - "Guidewire" Information for Use

BIOKNOTLESSRC ROTATOR CUFF REPAIR SUTURE ANCHOR SURGICAL TECHNIQUE. Surgical Technique for Arthroscopic Rotator Cuff Repair. Raymond Thal, M.D.

Lotus transducer Instructions for use

Desara TV and Desara Blue TV

AFX. Femoral Implant. System. The AperFix. AM Portal Surgical Technique Guide. with the. The AperFix System with the AFX Femoral Implant

with Blom-Singer Gel Cap Insertion System

Precautionary Statement ( )

Extracapsular Repair Monofilament Nylon Suture

mild Devices Kit - Instructions for Use

MULTIFIX S Knotless Implants

Instructions for Use io-flex Probe

DEVELOPED BY MEDSHAPE, INC. IN CONJUNCTION WITH PATRICK ST. PIERRE, M.D. BICEPS TENODESIS ARTHROSCOPIC AND SUBPECTORAL SURGICAL TECHNIQUE

Lapidus Arthrodesis System Instructions for Use

Integra. DigiFuse Cannulated Intramedullary Fusion System SURGICAL TECHNIQUE

Device Technical File

Instructions for Use Reprocessed LASSO Circular Mapping Diagnostic Electrophysiology (EP) Catheter

For the Attention of the Operating Surgeon: IMPORTANT INFORMATION ON THE MATRIXRIB FIXATION SYSTEM

Technique Guide. MULTIFIX P PEEK 4.5mm Knotless Fixation Implant

DIGESTIVE HEALTH ENTERAL FEEDING PRODUCTS

Stratis INSTRUCTIONS FOR USE. Needle-free Injection System. 0.5mL volume (+/-5%)

Low Profile Neuro Plating System. Surgical Technique

Fibrlok II 2529 Universal Optical Fiber Splice

Step by Step Description Use of Bonopty Coaxial Bone Biopsy System

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

low ProfIle neuro PlaTIng system

MEDICAL CORPORATION Asbury Rd., P.O. Box 758, Farmingdale, NJ USA Fax

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system.

Positioning System. Laparoscopic ventral hernia repair KEY BENEFITS SOFT TISSUE REPAIR

Achieving Independence. A Guide to Self-Catheterization with the Bard Touchless Plus Intermittent Catheter System

Technique Guide with Application Forceps. FlapFix. Quick and stable fixation of cranial bone flaps following a craniotomy.

Directions For Use. All directions should be read before use

Advisor FL Circular Mapping Catheter, Sensor Enabled D-AVSE-D10-F20, D-AVSE-DF10-F20, D-AVSE-D10-F15, D-AVSE-DF10-F15. Instructions for Use

Correction System. Surgical Technique

FS MTS. Micro Periodontal Tissue Scissors

Increase Strength, Flexibility, Range of Motion and Endurance. NeckXsystems Guidelines & Exercise. NeckX is Patent Pending

JuggerLoc Bone-to-Bone System for Ankle Syndesmosis Fixation. Surgical Technique

Basic Trocar System. Basic transbuccal instrumentation system for simplified intraoral plate and screw application.

Collinear Reduction Clamp

Technique Guide. Cranial Clamps with Application Instrument. Quick and stable fixation of cranial bone flaps following a craniotomy.

Product Information Packet

LOGIC SURGICAL TECHNIQUE GUIDE. In d i c at i o n s. Co n t r a i n d i c at i o n s. Mandibular Distraction System

CrossFix II. All-Suture, All-Inside Meniscal Repair System. Surgical Technique

Technique Guide. Rapid IMF Device. Temporary mandibular fixation device.

Instructions for Use Reprocessed Arthroscopic Shavers

Surgical Technique & Product Catalogue. Guide for Open & MIS Procedures

ThruPort Ergonic Minimal Incision Instrumentation

KneeAlign System Surgical Technique Guide

CATHETER ACCESS KIT. For use with Prometra Programmable Infusion Systems

Technique Guide. *smith&nephew N8TIVE ACL Anatomic ACL Reconstruction System

TrueSight Personalized Planning & Targeting System. Operative technique

AcUMEDr. Olecranon Threaded Compression Rod

CLARIVEIN INFUSION CATHETER

O.S.2-C & O.S.2-V. Static Staple - Stainless steel

SURGICAL TECHNIQUE THE TENDON ANCHOR SYSTEM

Endorectal Balloon (ERB) Endorectal Balloon (ERB) Instructions for Use

TABLE OF CONTENTS. 2 (8144 Rev 2)

Low Bend Distal Tibia Plates

Absorbable Woven Polyglycolic Acid Mesh Tube (Absorbable Nerve Conduit Tube) INSTRUCTIONS FOR USE 2 6

Integra. Endoscopic Gastrocnemius Release System SURGICAL TECHNIQUE

Zimmer NexGen MIS Tibial Component. Cemented Surgical Technique IMAGE TO COME

AXS Catalyst Distal Access Catheter

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plate Aiming Instruments. Part of the 3.5 mm LCP Percutaneous Instrument System.

WristMotion Wrist Hemiarthroplasty System Instructions for Use

Desara and Desara Blue

ACL reconstruction with the ACUFEX Director Drill Guide and. ENDOBUTTON CL Fixation System. *smith&nephew. Knee Series Technique Guide ENDOBUTTON CL

Uncompromised Exposure

CRANIOMAXILLOFACIAL. Rethinking Possibilities, Reshaping Lives

Knee Preservation System

Transcription:

RD180 SP TECHNOLOGY GUIDE READ THIS PRODUCT INSERT THOROUGHLY BEFORE USE FIG. 1 RD180 SP - THE RUNNING DEVICE 1 2 6 3 7 4 5 1 NEEDLE 2 FERRULE 3 SUTURE 4 DEVICE TIP 5 ANGLED SHAFT 6 HANDLE 7 PINK LEVER RD180 SP - THE RUNNING DEVICE DESCRIPTION Each sterile package contains one (1) RD180 SP suturing device (FIG. 1). RD180 SP is used for the placement of surgical suture as supplied in an appropriate RD QUICK LOAD. A short length of modified surgical stainless steel tubing, called a ferrule 2, is attached to one end of the suture 3. The ferrule is loaded into the ferrule compartment in the distal end of the device tip 4. Suture Placement and Suture Reset (FIG. 2) are each achieved by sequentially squeezing and releasing the pink lever 7. During Suture Placement, the initial squeeze of the pink lever advances the retracted needle forward through the selected tissue placed in the jaw of the device tip; the full squeeze advances the needle into the ferrule attached to its suture held in the device tip s distal end. Release of the pink lever retracts the needle, which pulls the now engaged ferrule and suture back through the tissue. Next, with the device tip oriented for Suture Reset, a second squeeze of the pink lever advances the needle with its now engaged ferrule and suture forward through the empty jaw into the device tip s distal end, where a latch feature retains the ferrule and suture. Release of the lever returns the needle alone back to its retracted position in the distal shaft ready for repeat suture placement. SOLUTIONS SUTURE PLACEMENT SUTURE RESET FIG. 2 SQUEEZE Advance Needle Forward Through Tissue RELEASE Pull Suture Back Through Tissue SQUEEZE Reinsert Suture Into Distal End RELEASE Retract Needle For Repeat Use 1

RD QUICK LOAD SUTURE FIG. 3 RD QUICK LOAD SUTURE 1 SUTURE TRAY 2 SUTURE RELEASE FEATURE 3 FERRULE 4 SUTURE 5 SUTURE TUBE 2 4 5 3 1 DESCRIPTION Each LSI SOLUTIONS RD QUICK LOAD sterile surgical suture is held in a customized tray 1 with suture release feature 2, designed to enable the rapid, easy and reliable loading of suture into RD and RD180 devices. RD QUICK LOAD products are available in excellent quality non-absorbable or absorbable suture materials in both braided and monofilament configurations (FIG. 11). A short length of modified surgical stainless steel tubing, called a ferrule 3, is attached to the end of the suture 4. The RD QUICK LOAD suture also includes a detachable clear suture tube 5 to keep the suture from tangling. Each sterile RD QUICK LOAD suture is individually packaged for single patient use. INDICATIONS RD QUICK LOAD surgical suture is indicated for use in general soft tissue approximation, but not for use in cardiovascular and neurological procedures. CAUTION: To avoid accidental needle exposure, DO NOT squeeze lever during suture loading. 2

LOADING SUTURE CAUTION: To avoid accidental needle exposure, DO NOT squeeze lever during suture loading. FIG. 4 1 REMOVE Suture And Suture Tube From Ferrule Holder Or Tray REMOVE & DISCARD ferrule holder before loading suture into RD180. OR REMOVE suture and suture tube from tray by grasping suture tube at suture release feature and pulling suture tube completely out of tray. 2 INSERT Suture Into Suture Track INSERT suture into the suture track as shown; may require pulling ferrule and suture further out of suture tube. 3 PULL Ferrule Into Compartment PULL suture to seat ferrule into ferrule compartment in the distal end of the device tip. It may help to guide the ferrule with a finger. Make sure ferrule is fully seated behind latch. 4 REMOVE Suture Tube 5 FIRE & RESET Orient Suture As Shown, Squeeze And Release Lever To Ensure Suture Is Ready In Distal End Of Device Tip FIRE & RESET to ensure suture is loaded properly. To avoid jamming the ferrule into the ferrule compartment, orient the suture directly away from the jaw as shown. Squeeze the lever to advance the needle through the jaw and into the newly loaded ferrule. Release the lever to pick up and retract the ferrule with attached suture back on the needle into the shaft. While continuing to orient the suture as shown, squeeze the lever to advance the needle, ferrule, and suture forward through the jaw to reset the ferrule into its compartment. Release the lever again and retract back the now-empty needle, leaving the ferrule and suture ready for patient use. 3

UNLOADING RD180 SP UNLOADING FERRULE AND REMAINING SUTURE FROM RD180 SP There are three simple and convenient options for removal of used ferrules from the needle prior to reloading RD180 SP. The easiest method is the AUTO-RELEASE Technique as illustrated below (FIG. 5). This technique automatically removes the suture and ferrule from the needle by simply pulling the lever fully forward. The next method is the PULL-OFF Technique as illustrated below (FIG. 6). This rapid approach requires an adequate length of suture remains attached to the ferrule throughout the unloading and does not utilize any other instruments. The third common unloading option, the CLAMP Technique (FIG. 7), is also simple and fast, but it requires an additional grasping device, such as a needle driver, to grasp and remove the used ferrule from the needle. FIG. 5 AUTO-RELEASE Technique Retract Suture Back. Pull Lever Fully Forward. Remove Suture With Ferrule. RETRACT NEEDLE, FERRULE, SUTURE PULL LEVER FULLY FORWARD REMOVE SUTURE, INSPECT This unloading technique requires that the needle with its engaged ferrule and suture must first be retracted back into the distal end of the device shaft. If they are not, simply squeeze and release the pink lever to pick up and retract the ferrule, suture, and needle. Once the ferrule, suture, and needle are retracted into the shaft, pull the pink lever fully forward to automatically remove the ferrule and suture off of the needle. Inspect and discard the used ferrule and suture. FIG. 6 PULL-OFF Technique SUTURE TRACK Retract Suture Back. Place Suture Over Distal Tip. Pull Suture With Ferrule Off Needle. SUTURE TRACK INSPECT As the name implies, the ferrule is simply pulled away from and off the needle by hand grasping and pulling the suture during this unloading technique. When adequate suture remains attached to the ferrule, ensure that the needle attached to the ferrule and suture is retracted in its resting position in the distal shaft. To avoid pulling the ferrule back through the suture track into its ferrule compartment across the jaw from the needle, orient the suture over the distal jaw as illustrated by the bent red arrow in (FIG. 6). One brisk pull on the suture in a direction away from the needle typically pops the ferrule off from the needle to free the used ferrule and suture from the device. INSPECT: The ferrule remains attached to the suture and the needle and device are undamaged. FIG. 7 CLAMP Technique Advance Needle Slightly. Grasp Ferrule With Clamp. Retract Needle Back. INSPECT A surgical grasping clamp, such as a needle driver, can be effectively used to remove the ferrule from the needle. Since this approach requires an additional tool and typically slightly more time than the other techniques, this option is usually reserved for situations in which the AUTO-RELEASE Technique or the PULL-OFF Technique are not effective. Squeeze the device s lever to slightly advance the needle with its attached ferrule. Apply the tip of the jaws of the grasping tool, shown highlighted in yellow (FIG. 7), only to the distal portion of the ferrule. Care must be taken to avoid damaging the needle with the grasper. Do not rock or rotate the ferrule with the grasper because such motion may bend, fatigue or break the needle tip. Push the pink lever fully forward to retract back the needle and to slide the tip of the needle out of the ferrule held in the grasper. Inspect that the ferrule has been successfully removed from the needle and that the needle and device are undamaged. 4

ACTIONS To facilitate the placement of multiple stitches of the same suture (i.e., running or tying the suture) without needing to manually reset each ferrule, the ferrule resetting mechanism of RD180 SP enables the remote return and resetting of the ferrule back into the ferrule compartment. The operator presents an appropriate tissue structure into the gap of the metal jaw in the device tip of the RD180 SP. During suture placement, the pink lever is squeezed to advance the retracted needle from the shaft of the device through the tissue in the jaw and into the ferrule. The distal contoured end of the RD180 SP needle engages and captures the ferrule with its attached suture. Releasing the pink lever retracts the needle with attached ferrule and suture back through the tissue. For Suture Reset, the distal tip is then moved away from any tissue structures to clear the jaw for ferrule resetting. The pink lever is again fully squeezed to advance the needle, ferrule and suture forward through the empty jaw toward the ferrule compartment at the most distal end of the device tip. Care must be taken to ensure the suture crimped to the distal end of the ferrule is oriented to permit the suture to freely pass through the suture track opening in the ferrule compartment. Jamming misoriented suture into the ferrule compartment can damage suture and device. With the pink lever fully squeezed and the needle with its attached ferrule and suture completely forward, the now rotated needle will permit the ferrule reset latch to engage the face of the ferrule and cause its release from the needle. With the first tissue suture placement complete, the ferrule reset into the ferrule compartment, and the pink lever back in its starting location, RD180 SP is ready for another tissue bite. This sequence can be repeated for up to 12 bites (or 12 complete functional cycles) per device. CONTRAINDICATIONS Minimally invasive surgical procedures should only be performed by physicians having adequate training and familiarity with endoscopic techniques. In addition, medical literature should be consulted relative to techniques, complications and hazards prior to the performance of minimally invasive procedures. RD180 SP is not intended to be used with any suture other than RD QUICK LOAD suture. Do not use this suture under conditions in which excessive suture tension can lead to tissue damage. For example, do not use RD QUICK LOAD surgical suture through an excessively narrow, restrictive or defective cannula access port, which could significantly impair easy and smooth passage of the suture or device. WARNINGS Do not resterilize. The performance of RD180 SP after cleaning or other reprocessing has not been verified and is not supported by LSI SOLUTIONS. Discard open, unused, expired or damaged devices or devices in damaged primary packaging. As with any foreign body, prolonged contact of any suture with salt solutions, such as those found in the urinary or biliary tracts, may result in calculus formation. Users should be familiar with surgical procedures and techniques involving suture before employing RD180 SP for wound closure, as the risk of wound dehiscence may vary with the site of application. Acceptable surgical practice must be followed with respect to drainage and closure of infected or contaminated wounds. Redundant, cut-away suture remnants, used ferrules, and RD180 SP devices, along with packaging, must be accounted for and disposed of consistent with standard, accepted medical device disposal procedures. RD180 SP is indicated for use in the approximation of soft tissue. Applications other than for soft tissue closure, or to anchor another device, can result in failure to pick up suture or in damage to the device making it unsuitable for continued use. Never drive the needle into suture, bone, dense ligamental tissue, or other instruments. PRECAUTIONS Federal (U.S.A.) law restricts this device to sale, distribution and use by, or on, the order of a physician. Check for hemostasis or leakage where appropriate. Minimally invasive instruments may vary in diameter from manufacturer to manufacturer. Before endoscopic instruments and accessories from different manufacturers are employed together in a procedure, verify compatibility and ensure electrical isolation or grounding are not compromised. Care must be taken when inserting this or any device through a cannula to avoid advancing the device incorrectly (e.g., too far or too quickly). Device insertion should be easy, smooth and controlled to minimize the risks of trauma to the patient or damage to the device. Always assure insufflation, camera position and device tip location are viewed under direct visualization before advancing the needle. Ensure obstructions do not interfere with the movement of the needle of RD180 SP. In handling RD180 SP, care should be taken to avoid jamming the suture into the ferrule compartment and damage to the needle. Avoid damage to the needle, suture or ferrules due to direct application of surgical instruments, like forceps, needle holders, clamps, etc. Adequate knot security requires accurate completion of accepted surgical techniques for constructing surgically tied knots or the use of the TK Ti-KNOT DEVICE and TK QUICK LOAD as warranted by surgical circumstances and the experience of the surgeon. Before loading RD180 SP with another RD QUICK LOAD suture, assure the remaining suture tail and ferrule from the previous load has been removed from the needle. Failure to appropriately remove used ferrules from the needle can result in damage to the device, including intracorporeal or extracorporeal fracturing off the tip of the needle, making it unsuitable for continued use. After each loading and re-loading of a new suture into this device, squeeze the pink lever to drive the needle forward into the new ferrule loaded into the ferrule compartment. If the ferrule is picked-up by the needle, then squeeze the lever again to reset the ferrule and suture back behind the latch. If the needle rotation is oriented to reset the ferrule, then the needle will retract back without the ferrule and suture attached. This cycling (FIG. 4, Step 4) of the needle helps ensure that the previous ferrule was properly removed, the new ferrule is installed properly and the operator receives the device with its needle oriented to pick-up the ferrule on its first needle advancement. If the previous ferrule was not properly removed from the needle prior to reloading the device, the needle will not fully advance into the new ferrule in the ferrule compartment. Driving a needle with a ferrule into another ferrule can lead to the breaking off of the tip of the needle. Do not use RD180 SP to dissect or aggressively manipulate tissue structures. Verify the ferrule is still retained within the ferrule compartment and the device has not been damaged or deformed before attempting to place a stitch. Do not manipulate the device at any time with the pink lever partially actuated. This may expose sharp surfaces that can cause trauma to the patient, the device operator or other staff, or damage the device. To avoid inadvertent suture damage, ensure the ferrule always enters the ferrule compartment with its suture oriented to freely pass through the ferrule compartment s suture track. Do not use damaged or expired suture. Ensure the advancing needle targets and enters the ferrule compartment. For example, during the suture placement avoid using an extended needle to manipulate or lift tissue because such an action can cause the needle to deviate from its targeted course toward the ferrule compartment. A needle tip, not entering the ferrule compartment properly, can strike the distal tip of the device and lead to undesired outcomes, including needle tip fracture. For another example, during suture reset, avoid applying tension to the suture from the ferrule on the needle. Tension on the suture can cause the needle to deviate off target and lead to the ferrule possibly striking the distal tip, which can cause needle tip fracture. ADVERSE REACTIONS Adverse effects associated with the use of suture include wound dehiscence, failure of adequate wound support in closure sites where expansion, stretching or distension occur, enhanced bacterial infectivity, minimal acute inflammatory tissue reaction, localized irritation when skin sutures are left in place for greater than 7 days, calculi formation in urinary and biliary tracts when prolonged contact with salt solutions such as urine and bile occurs, and pain, edema and erythema. MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING RELATED PATENTS 5,431,666; 5,520,702; 5,562,686; 5,643,289; 5,669,917; 5,766,183; 6,368,334; 6,533,796; 6,641,592; 6,997,931; CA2141911; CA2141912; CA2141913; CA2173520; EP0669101; EP0669102; EP0669103; EP0748612 and DE69505283.7; DE69512447.1; DE69512446.3. Additional patents pending. The LSI logo, LSI SOLUTIONS, RD180, The Running Device, TK, Ti-Knot, Quick Load, and Perfect Performance Policy are trademarks and registered trademarks of LSI SOLUTIONS. 5

RD180 SP TECHNIQUE PEARLS FIG. 8 ADVANCE NEEDLE PRIOR TO INSERTION DO NOT HOLD SUTURE COMPLETE SQUEEZE, HOLD, COMPLETE RELEASE FIG. 9 SUTURE PLACEMENT RD180 SP DEVICE ORDERING REORDER # 021450 SUPPLIED: Box of 6, Sterile FIG. 11 GENERAL Except During Cannula Insertion NO OBSTRUCTIONS TAKE UP SLACK Avoid Hitting Suture, Instruments, Bone, Etc. Pull Suture Tail To Relieve Excess STAY AHEAD Suture Behind Tip Prevents Locking SWEEP & TOUCH If Needed To Stay Ahead FIG. 10 OUT 1CM TIP DOWN ALWAYS RESET SUTURE RESET After Bite, Keep Suture Short Proper Orientation For Reinsertion Even Before Cannula Withdrawal RD QUICK LOAD SUTURE Non-Absorbable SUPPLIED: Box of 12, Sterile, Suture Length 53 Absorbable Suture Material Suture Type Reorder # Size Polyester Braided 020979 021010 0 Polypropylene Monofilament 020989 PGA Braided 021025 PDO Monofilament 021030 021506 0 SynPoly Monofilament 021145 LSI Brand POLYESTER POLYESTER POLYPROPYLENE STRONGSORB MONOGLIDE MONOGLIDE MONOGLIDE II Color / Coating Green / PTFE Green / PTFE Blue / NONE Purple / YES Purple / NONE Purple / NONE Purple / NONE SOLUTIONS 2011 LSI SOLUTIONS 7796 Victor-Mendon Rd. Victor, NY 14564 U.S.A. Tel: (866) 575-3493 Tech Support: (866) 428-9092 Fax: (585) 742-8086 www.lsisolutions.com P/N 021648B 01.08.14 6