Bone Conserving Hip Replacement Surgical technique

Similar documents
Surgical technique MkII instrumentation

Cementless Tapered Femoral Stem Surgical technique

MetaFix. Cementless Total Hip Replacement Surgical technique

Cementless Tapered Femoral Stem Surgical technique

3A ODEP. Preserving the natural anatomy and restoring patient biomechanics

Encina Taper Stem. Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

MetaFix. Cementless Total Hip Replacement Surgical technique

5A* ODEP. Conserving bone. Preserving soft tissue. Restoring biomechanics. rating

MetaFix Cementless Total Hip Replacement Product overview

Taperloc Complete Hip System. Surgical Technique

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

Trinity. Advanced Bearing Acetabular System Surgical technique

THE NATURAL FIT. Surgical Technique. Hip Knee Spine Navigation

Optimum implant geometry

Approach Patients with Confidence

Approach Patients with Confidence

Dual Mobility System Surgical technique

Dual Mobility System Evaluation surgical technique

S U R G I C A L T E C H N I Q U E

TaperFit. Cemented Total Hip Replacement Surgical technique

Bone Preservation Stem

Anterior Approach Surgical Technique. Paragon Stem System. enabling people to enjoy life

Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

Optimizing function Maximizing survivorship Accelerating recovery

Metha Short Hip Stem System

MIAA. Minimally Invasive Anterior Approach Surgical technique

TaperFill. Surgical Technique

Optimum implant geometry

Revision. Hip Stem. Surgical Protocol

Surgical Technique. Hip System

Surgical Technique r5.indd 1 12/8/10 10:36 AM

UNDERSTANDING TRADITION, MASTERING INNOVATION. Surgical Technique

TaperFit Cement-in-Cement Revision Femoral Stem Surgical technique

Uniglide. Unicompartmental Knee Replacement Product overview

Ovation Hip System. Surgical Technique

SURGICAL TECHNIQUE. Alpine Cementless Hip Stem

Progeny Hip Stem. Surgical Protocol and Product Specifications

asterloc Surgical Technique HIP SYSTEM UNDERSTANDING TRADITION, MASTERING INNOVATION Hip Knee Spine Navigation

SURGICAL TECHNIQUE. Entrada Hip Stem

MITCH TRH System Modular Head Operative Technique

Integral 180 Surgical Technique

Surgical technique. Dynamic Simulation Personalised Solution

Surgical Technique. *smith&nephew POLARSTEM Cementless Stem System

CORAIL HIP SYSTEM SURGICAL TECHNIQUE

Optimum implant geometry

FLH /11

Surgical Technique VPLWK QHSKHZ 1$126 1HFN 3UHVHUYLQJ +LS 6WHP 1716-e_NANOS_OPT.indd :27

Preoperative Planning. The primary objectives of preoperative planning are to:

Bi-Polar 22.2mm & 28mm System - Operative technique

PLR. Proximal Loading Revision Hip System

HIP SYSTEM SURGICAL TECHNIQUE

Hype Femoral stems. Surgical technique

Aesculap Trilliance Triple Tapered Polished Hip Stem

FIRST STEM SPECIFICALLY DESIGNED FOR AMIS. Surgical Technique

HELIOS h i p s y s t e m

AML Hip System. Design Rationale/ Surgical Technique

Hip Fracture Management. Product overview

Rotaglide+ TM. Total Knee System Product overview

3A ODEP rating, demonstrating 99.5% survivorship at 3 years for aseptic loosening

Avenir Femoral Hip System

Uniglide. Unicompartmental Knee Replacement Product overview

the shape, the size, the fit Ascension Modular Radial Head

Scan Bi-Polar 22/28. Operative Technique

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY

Common Instruments for Biomet Hip Systems

Cementless femoral stem type SF

Alloclassic Zweymüller Stem

Inspiring people, Enriching lives

SURGICAL TECHNIQUE. Alpine Cemented Hip Stem

3A ODEP rating, demonstrating 99.5% survivorship at 3 years for aseptic loosening

Featuring. Technology. Product Rationale

ZMR Crossover Instruments. Abbreviated Surgical Technique

*smith&nephew SL-PLUS Cementless Femoral Hip System. Product Information

EVOLVING OUR HERITAGE, MEETING YOUR NEEDS. Surgical Technique

Zenith. Total Ankle Replacement Surgical technique

S H O U L D E R Solutions by Tornier. Aequalistm. Pyrocarbon Humeral Head. surgical technique

comprehensive Design Rationale shoulder system Knees Hips Extremities Cement and Accessories PMI TEchnology

9800 Metric Blvd. Austin, Texas

RESTORATION MODULAR. Surgical Protocol REVISION HIP SYSTEM

THE P.F.C. SIGMA FEMORAL ADAPTER. Surgical Technique

Design Rationale. ECHELON Primary Hip System

Surgical Technique. *smith&nephew POLARSTEM Cementless and Cemented Stem System

Restoration Modular. Revision Hip System Surgical Protocol

Surgical Technique. DISCLOSURE: This device is not approved for sale in the U.S.A. Customer Service:

*smith&nephew SL-PLUS

TRIAL COMPONENTS SURGICAL TECHNIQUE REAMING THE TIBIAL AND FEMORAL INTRAMEDULLARY CANAL

ACTIS. TOTAL HIP SYSTEM Approach Active Patients with Confidence DESIGN RATIONALE

TORNIER AEQUALIS ASCEND. Shoulder System SURGICAL TECHNIQUE

RECOVERY. P r o t r u s i o

Operating Instruction. Müller Hip Stem

RESTORATION MODULAR. Surgical Protocol REVISION HIP SYSTEM

Comprehensive Reverse Shoulder System Augmented Baseplate

EXACTECH KNEE. Operative Technique ADDENDUM. Metaphyseal Cones. Surgeon focused. Patient driven. TM

Absolut TM Cemented Stem. Surgical Technique

Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology. Surgical Technique

ACETABULAR CUP SURGICAL TECHNIQUE

Clinical Evaluation Surgical Technique

RESTORATION MODULAR. Surgical Technique REVISION HIP SYSTEM

RECLAIM REVISION HIP SYSTEM

Transcription:

MiniHip Bone Conserving Hip Replacement Surgical technique

MiniHip Contents Operative summary 4 Overview 5 Pre-operative templating 6 Operative technique 7 Neck resection 7 Femoral canal preparation 7 Trial reduction 8 Implantation of the stem 8 Final reduction 9 Appendix: Stem extraction 9 Sizing guide 10 Description 11 Indications 11 Contraindications 11 Ordering information 11 2

Activity Versatility Efficiency a The bone conserving hip for active patients 3

MiniHip Operative summary a. Curved awl b. Broaching c. Trial reduction d. Implantation 4

Overview 138º The MiniHip bone preserving, physiological hip replacement has been specifically designed to address the clinical needs of active men and women of all ages who would usually be appropriate for a standard uncemented hip replacement. Anatomic restoration can be achieved by utilising an optimal neck resection (Figure 1). The dedicated short stem design of the MiniHip combines the bone preserving benefits of hip resurfacing with the inherent stability of traditional total hip replacement, providing a solution for demanding uncemented patients. Designed to fit and fill the proximal neck, the MiniHip ensures immediate and long-term proximal stability, which is further enhanced with a hydroxyapatite coating for stable cementless fixation (Bi-coat ). The initial press fit coating facilitates primary stability to help promote bone integration. The specialised instrumentation designed for all minimally invasive approaches, combined with a practical operative technique, assists in facilitating: Greater bone preservation 118º 127º a Superior physiological load transfer compared to standard THR 1 Proven Bi-coat fixation 2 Reproducible anatomical restoration 3,4 Efficient three stage procedure Note: MiniHip is suitable for Dorr type A and B bone quality. MiniHip is not suitable for type C, osteoporotic stove femurs. Figure 1. Reproducibility through anatomical restoration 5

MiniHip Pre-operative templating When using the MiniHip system, pre-operative planning is critical to determine the optimal size, neck angle and offset of the implant. Templating will help determine the level of neck resection and optimal cup position. The MiniHip X-ray templates are available in four different magnifications (100%, 110%, 115% and 120%). The 115% magnification is provided as standard. A/P and M/L X-rays should be used in combination with the templates to determine the correct size and positioning of the implant. The resection guideline or demarcation line is defined by using a medium length head (0mm) on the template overlaid onto the centre of rotation. The template is then rotated to achieve fit and fill of the neck superior/ laterally whilst in turn maximising coverage of the medial calcar and then finally distal lateral cortices contact. When using the M/L X-ray, proximal contact should be achieved posteriorly and anteriorly, and distal contact should be achieved posteriorly. The demarcation line is where the cementless coating ends proximally. To achieve anatomical restoration the following four key stages need to be implemented: Define centre of rotation Fit and fill in the neck Maximal medial calcar contact Distal lateral contact/fill (posterior, anterior, posterior- PAP) The neck resection/demarcation line of the stem should always be parallel to the head-neck junction as shown by the red line in Figure 2. Figure 2. Pre-operative templating 6

Operative technique a Step 1. Intra-operative templating When defining the neck resection in situ, use the piriformis fossa as a constant landmark to determine the level of resection. Step 2. Curved starter awl The entry point of the starter awl should be 3-4mm superior to the centre of the neck to create a pathway into the top of the diaphysis. This will help prevent both undersizing of the stem and misalignment of the broaches. The curved starter awl is used for further femoral preparation accommodating the natural curvature of the proximal femur allowing the compaction broaches to follow a sequential pathway. Step 3. Femoral canal preparation The stem is designed to be supported by compacted cancellous bone gaining mechanical stability and fixation in the neck and metaphysis. Always start with the smallest broach, progressively using larger broaches until the pre-templated size is achieved. 7

MiniHip A stable fit is achieved when the broach fits and fills the proximal femur and the face of the final broach sits flush with the resection line, as detailed in the pre operative templating on page 6. In order to ensure that the femur will accommodate the planned size of implant, a 1mm cancellous ring should be maintained around the broach for sizes 1-4 and a 2mm ring for sizes 5-9. Usually a 2-4mm ring of cancellous bone around the medial calcar is also observed. Step 4. Trial reduction A trial reduction may then be performed using a trial head and the broach. Intraoperative X-ray To assess the trial orientation and sizing, it is recommended that an intraoperative X-ray using a C-arm be taken whilst the broach, trial neck and head are in still in situ prior to implantation of the definitive implants. Step 5. Implantation of the stem The final broach indicates the size of the definitive implant, which is inserted by hand. If the definitive stem seats by more than 10mm proud above the resection line, remove the stem and re-broach with the finishing broach 2-4mm below the resection line. 8

Appendix a Once the stem is seated by hand, the stem impactor can be used to fully seat the implant until the edge of the Bi-coat (demarcation line) is flush with the resection line. Step 6. Final reduction Once the acetabular cup is implanted, a full trial reduction can be performed allowing for fine tuning of the head offset. The definitive head is impacted onto the stem ensuring the trunnion is free from debris. The hip can then be reduced and closure performed. Stem extraction In the unlikely event that the stem needs to be removed the stem extractor set can be used. The extractor device is placed over the 12/14 trunnion and the slap hammer is rotated until the trunnion is securely clamped. Do not implant the stem with this instrument. Note: Do not overtighten the thread as this will cause damage to the plastic collar on the extractor. It should be tight enough to form an interference fit around the base of the neck to aid removal. The stem can then be extracted in conjunction with revision ancillary instruments. If the stem extractor is required it should be ordered separately prior to the operation. 9

MiniHip Sizing guide offset neck length stem length Size 1 2 3 4 5 6 7 8 9 offset (mm) 32.2 33.3 34.5 35.6 36.8 37.9 39.1 40.2 41.4 neck length (mm) 29.5 30.5 31.5 32.5 33.5 34.5 35.5 36.5 37.5 stem length (mm) 79.5 84.2 89.0 93.8 98.5 103.3 108.0 112.8 117.5 10

Description Contraindications Ordering information The MiniHip is a titanium femoral stem (Ti-6Al-4V) coated with a layer of hydroxyapatite applied over a layer of pure titanium. The distal section of the stem is polished. The device is available in a range of nine sizes each providing a 130 o CCD neck angle. The device is intended to be used with 12/14 modular taper heads. The MiniHip is intended to provide increased patient mobility and reduce pain by replacing the damaged hip joint articulation in patients where there is evidence of sufficient sound bone to seat and support the components. Infection Osteomyelitis Sepsis Osteomalacia Distant foci of infections Osteoporosis Marked bone loss or bone resorption Metabolic disorders which may impair bone formation Vascular insufficiency Implants 580.0001 Size 1 Standard Stem 580.0002 Size 2 Standard Stem 580.0003 Size 3 Standard Stem 580.0004 Size 4 Standard Stem 580.0005 Size 5 Standard Stem 580.0006 Size 6 Standard Stem 580.0007 Size 7 Standard Stem 580.0008 Size 8 Standard Stem a Indications The indications for the MiniHip stem as a total hip arthroplasty include: Muscular atrophy or neuromuscular disease Allergy to implant material Severe deformity 580.0009 Size 9 Standard Stem Instruments 580.9991 MiniHip Cementless Stem System Non-inflammatory degenerative joint disease including osteoarthritis and avascular necrosis Rheumatoid arthritis Correction of functional deformity Developmental dysplasia/congenital dislocation of the hip X-Ray templates 580.9190 MiniHip X-ray template 115% 580.9090 MiniHip X-ray template 100% Stem extractor set 580.9410 Stem Extractor Set The MiniHip stem is indicated for cementless use only. 11

References: 1. Short stems are less likely to lead to bone resorption; bone remodeling following THR. Yeoman M, Cizinauskas A, Lowry C, Vincent G, Collins SN, Simpson DJ, Continuum Blue, UK; 2 Corin Ltd, UK; 3 Imorphics, UK. Data held on file at Corin 2. Collier CG. The assessment of early osteointegration, as a function of coating. August 2002. Report held on file. 3. Short stem total hip replacement: are you being conservative enough? Simpson DJ, Lowry C, Yeoman M, Cizinauskas A, Vincent G, Collins SN, Corin, UK; 2 - Continuum Blue, UK; 3 - Imorphics, UK. Data held on file at Corin 4. Presented data at the Baden Baden 58th Annual VSO meeting, (Tetnang, Germany) 2010. Dr Christian Grasselli discussed the multicentre clinical data for 250 bone conserving MiniHips. The Corinium Centre Cirencester, GL7 1YJ, UK t: +44 (0)1285 659 866 f: +44 (0)1285 658 960 e: info@coringroup.com www.coringroup.com Printed on 9lives 80 which contains 80% total recycled fibre and is produced at a mill which holds the ISO 14001 for Environmental Management Systems. The pulp is bleached using Elemental Chlorine Free processes. 2012 Corin P No I920 Rev2 02/2012 ECR 11672