STUDY ON APPLICATION OF STRAIN MEASURING TECHNOLOGY IN BOARD LEVEL ASSEMBLY PROCESS

Similar documents
The Do s and Don ts of Pressure Transducers

Pb-Free/RoHS Solutions

IPC-6018A. Microwave End Product Board Inspection and Test IPC-6018A. A standard developed by IPC. Supersedes IPC-6018 January 1998

X-RAY / BONDTESTER RELIABILITY STUDY OF BGA DEVICES IMPACT OF INTERFACIAL VOIDING

Qualification and Performance Specification for Rigid Printed Boards

Failure Mechanisms and Risk on LEDs and LED Systems SMT

Pb-Free Reflow, PCB Degradation, and the Influence of Moisture Absorption

SpiderX. Portable Residual Stress X-Ray Diffractometer.

Avoiding the Pitfalls of Voiding in PCB Assemblies. Kim Flanagan Indium Corporation SMTA Capital August 23 rd, 2018

MODELING AN SMT LINE TO IMPROVE THROUGHPUT

Eye Of SOLDERLESS INTERCONNECT TECHNOLOGY GUIDELINE. the Needle

3D TSV Cu Pillar Probing Challenges & Experience

Matrix Series BGA Sockets

FlexiSafe MLCC Termination Device Performance

Research on Digital Testing System of Evaluating Characteristics for Ultrasonic Transducer

Imaging spot weld inspection using Phased Array technology new features and correlation to destructive testing

International Journal of Advance Engineering and Research Development. Gesture Glove for American Sign Language Representation

INSTRUCTION MANUAL LEG PRESS (NEW MODEL) OPTION OF K2 GYM

Study of Micro-Electrode Array for Neural Populations Stimulating and Recording

Stacked Die Advanced Interconnect Technologies

Angular Measurements with BIOPAC Goniometers & Torsiometers

Multielement ultrasonic probes for projection imaging of biological media

Sign Language Interpretation Using Pseudo Glove

GLAST Large Area Telescope:

Base S D T B

AcUMEDr. Arc Wrist Tower. For Wrist Arthroscopy And Fracture Reduction

Low Row. User manual E S S E N T I A L S T R E N G T H

Introducing Via-in-Pad Blind Via Technology to Any PCB Multilayer Fabricator

Failure criteria for Adhesives. Sainath Kadam, 3mE 19 oktober 2014

II. PROCEDURE DESCRIPTION A. Normal Waveform from an Electrocardiogram Figure 1 shows two cycles of a normal ECG waveform.

LION. Application Note PRECISION. Linear Position Measurement with Eddy-Current Sensors. LA March, Applicable Equipment: Applications:

Cerus P-Series General Specifications Section 15172

Goniometer series 400

3. Dimensions, weights Placement and Assembly Pressure drops Noise data Material... 14

Development of an Electronic Glove with Voice Output for Finger Posture Recognition

3. PATIENT POSITIONING & FRACTURE REDUCTION 3 8. DISTAL GUIDED LOCKING FOR PROXIMAL NAIL PROXIMAL LOCKING FOR LONG NAIL 13

Fundamentals of Pressure Transducers

for Heart-Health Scanning

Standard Practice for Verification of Testing Frame and Specimen Alignment Under Tensile and Compressive Axial Force Application 1

Embedded Based Hand Talk Assisting System for Dumb Peoples on Android Platform

Surface Mountable PTC Resettable Fuse: FSMD Series

Zimmer NexGen Trabecular Metal Tibial Tray

Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion

CRACK DETECTION AND PIPELINE INTEGRITY SOLUTIONS

Flaw Assessment Using Shear wave Phased array Ultrasonic Transducer

MEDIUM-FLOW PNEUMOTACH TRANSDUCER

Instruction Manual Aerogen, Inc. Part No. AG-AL1010 Rev. C

Other Major Component Inspection II

E SERIES. Contents CALIBRATION PROCEDURE. Version 2.0

A m e r i c a s D e n t a l E q u i p m e n t C o m p a n y. Rev 2/15. D a n s e r e a u

OPERATIVE TECHNIQUE SKS Total Knee Replacement

AK FIXATOR SYSTEM AK1

Design of the HRV Analysis System Based on AD8232

System. Humeral Nail. Surgical Technique

APPLICATION AND DEPLOYMENT OF ADVANCED NDE TECHNIQUES IN HIGH PRESSURE VESSELS

Installation of force transducers

HER103, HER107 Power Diodes - Fast Recovery

Low Temperature Curable Polyimide Film Properties and WLP Reliability Performance with Various Curing Conditions

Monitor Instructions for Models: CHB-R6 CHB-UV6

Electromyography II Laboratory (Hand Dynamometer Transducer)

THE DEVELOPMENT AND MANUFACTURE OF FIXED- ULTRASONIC INSPECTION REFERENCE REFLECTORS AND TRANSDUCERS FOR COMPRESSOR BLADE DOVETAILS

Input Load (ma) Typ.

Nuclear Associates

Chapter 5: Checking and Maintaining Ultrasound Equipment

Each student should record the ECG of one of the members of the lab group and have their own ECG recorded.

Technical support: +49 (0)7223 /

Measurement System Analysis Page 1 of 15

Descriptions of NDT Projects Fall 2004 October 31, 2004

DEFORMATION TRANSDUCER CALIBRATOR OPERATION

The Bowflex Conquest Home Gym Assembly Instructions

A hybrid approach for identification of root causes and reliability improvement of a die bonding process a case study

Mechanical Simulation of Probing on SMART POWER POA devices

CATHETER ACCESS KIT. For use with Prometra Programmable Infusion Systems

FUSE TECHNICAL REPORT

Development and application of a hand force measurement system

Assignment Question Paper I

ANATOMIC SURGICAL TECHNIQUE. 5 in 1. Conventional instrumentation 07/11/2013

ULTR A SERIES G7-S75

Overview of the FITNESSGRAM Body Composition Standards

1. EXECUTIVE SUMMARY 2. PRODUCT SUMMARY

Patella Planing System

DSI Series Installation

PROFESSIONAL GRADE FITNESS CABLES INSTRUCTION MANUAL AND EXERCISE GUIDE. Engineered by

Design of Low-Power CMOS Cell Structures Using Subthreshold Conduction Region

Quality Assurance of Ultrasound Imaging in Radiation Therapy. Zuofeng Li, D.Sc. Murty S. Goddu, Ph.D. Washington University St.

ULTR A SERIES G7-S23

ULTR A SERIES G7-S13

COIL PROCESSING SOLUTIONS

Fill the Void. Tony Lentz Greg Smith

PCA Enhanced Kalman Filter for ECG Denoising

Quality Management Guideline for Suppliers. Appendix. Instructions for the Preparation of 8D-Reports

Cu/SnAg Double Bump Flip Chip Assembly as an Alternative of Solder Flip Chip on Organic Substrates for Fine Pitch Applications

Zimmer Trabecular Metal Ankle Interpositional Spacer and Trabecular Metal Ankle Fusion Spacer

R-Group Finland Oy. RLS Lifting Sockets Technical Manual According to Eurocodes, EU Machinery directive 2006/42/EC and VDI/BV-BS 6205 CE Approved

8 Performing Medical Procedures

3M Four Wall Header.100 x.100 Low Profile, SMT Straight, Straight and Rt Angle Through-Hole D2500 Series

High-Power Locomotive Solid Axle Defect on-line Detection Technique

Figure 1: EVKT-MACOM with EVMA-CONN Daughter Board

JNL454 55" STOP. 40kg 88lbs. 140cm. AVF Group Ltd. Hortonwood 30, Telford, Shropshire, TF1 7YE, England. Leaflet No rev00

Transcription:

As originally published in the SMTA Proceedings STUDY ON APPLICATION OF STRAIN MEASURING TECHNOLOGY IN BOARD LEVEL ASSEMBLY PROCESS Yabing Zou, Daojun Luo, Weiming Li China Electronic Product Reliability and Environmental Testing Institute Guangzhou, China zouybing@163.com ABSTRACT The board level assembly technology which contains soldering and assembling is the key link in the manufacture of electronic products. The quality and reliability of board level assembly process directly affects the quality and reliability of the whole products. This has to consider the impact of the strain on the soldering and assembling process. With the high density package and assembly prevails, and the materials at the transformation of environmental protection laws and regulations, the strain-induced damages in board level assembly process are frequent. It is well known that the excessive strain can result in various failure modes for different package types, surface finishes, or laminate materials. Such failures include solder joint cracking, trace damage, laminate related adhesive failure (pad lifting) or cohesive failure (pad crater) and substrate cracking. Therefore, characterization of PCBA strain in worst-case is critical to the reliability assurance for electronic products. The application of strain gage test had been improved to be one favorable and effective method to discriminate the hazardous process. Based on the conversion principle between strain and resistance change, strain gage test is a kind of effective measuring technology, which can be used in the fields such as theoretical verification, quality inspection and scientific research. However, the study on strain measurement for PCBAs in electronic industry has just started, and there are still many unsolved puzzles, whether about strain gage selection or about measurement methodology. To address these problems, this study conducted a deep analysis of the basic principle for strain gage test technology combining with strain-induced damage phenomena of PCBAs. Then the strain gage test was applied to PCBA reliability evaluation during a typical mechanical assembly process. And systematic analysis for some critical problems during this process was conducted, such as the strain gage selection technology, specific operation method and strain data analysis method. Key words: strain measuring technology, board level assembly process, strain-induced damage INTRODUCTION The application of strain gage test for controlling the warpage of printed circuit board (PCB) had been improved to be one favorable and effective method to discriminate the hazardous process. However, along with the increasing of interconnect density and the embrittlement of halogen-free of PCB substrate, the probability of damage resulted from warpage also increased. Otherwise the thermal stress from multiple soldering process and mechanical stress form assembling and working bring the challenges to the component undoubtedly [1,2]. Recently, a great deal of PCB assembly manufacturers required to operate under the special strain level from the client or the component supplier. In this case, the study for the strain distribution on the PCB by means of strain gage methodology gets the wide attention more and more. Characterization of the worst case for PCB assembly (PCBA) strain is critical due to the susceptibility of components to strain induced failures. Excessive strain can result in various failure modes for different types [3, 4], surface finishes, or laminate materials. Such failures include solder joint cracking, trace damage, laminate related adhesive failure (pad lifting) or cohesive failure (pad crater) and substrate cracking. The strain gage test [5] allows the objective analysis of the strain and strain rate levels to which a surface mount component may be subjected during PCBA assembly, test and operation. PCBA strain measurement includes application of strain gages to the printed circuit board near the specified components, followed by subjecting the instrumented board to various test, assembly, and handling operations. Steps which exceed strain limits are deemed excessive and re identified so that corrective actions can be made. The strain limits may come from the customer, component supplier or internal best known practices. TEST METHOD The typical PCBA strain gage test procedure includes the following four steps. Step 1: Select strain gage sensor A strain gage is a device whose electrical resistance varies in proportion to the amount of strain in the device. The IPC/JEDEC-9704 [6] guideline document recommends using three-element stacked rosette strain gages for PCB strain gage tests. A rosette strain gage (see Figure 1) consists of three independent strain gages stacked on top of each other. Unlike a wire strain gage, which can measure strain in only Proceedings of SMTA International, Sep. 25-29, 2016, Rosemont, IL, USA Page 488

one direction, a rosette strain gage measures the full state of strain on the surface of a part. In other words, it can measure not only the two extensional strains, e x and e y, but also the shear strain, g xy, with respect to some given x-y axis system. Figure 1: Three-Element Stacked Rosette Strain Gage According to the IPC/JEDEC-9704 guideline, details of the recommended strain gage are as follows: Three-element stacked rectangular (0 /45 /90 ) rosette strain gage 1.0 to 2.0 mm, 2 nominal, gage sensor size 120 or 350 W strain gages Lead wire attach pads located at or lead wires attached on one side of strain gage Step 2: Prepare PCB for Test and Mounting Strain Gages Typically, the test boards are not required to be electrically functional, but they must mechanically represent the latest design. The IPC/JEDEC-9704 guideline recommends that measure any BGA device with a package body size equal to or larger than 27 by 27 mm (see Figure 2). This includes selecting the location at which are going to mount the strain gages. If there is no space to mount a strain gage on the board, it might have to make space on the PCB by removing already mounted components on the test board. Figure 2: Recommended Gage Placement for BGA Components (IPC-9704) Board preparation is a critical part of the instrumentation process. Proper board preparation helps ensure the proper bonding of strain gages; this, in turn, improves reading accuracy. It also should perform strain gage attachment in accordance with instructions the strain gage and adhesive suppliers provide. Note that strain gages require the use of specially formulated adhesive systems, and strain gage suppliers typically provide this information. It can find additional details about board preparation, strain gage attachment, and wire routing in the IPC/JEDEC-9704 guideline document. Step 3: Measure Strain After preparing the board and mounting the strain gages, the third step in PCB strain gage testing is connecting the sensors to data acquisition instrumentation and running the actual test. The length of the test may vary - it can typically run for 5 to 10 seconds while data is recorded. IPC/JEDEC- 9704 recommends paying attention to the following parameters while running the test: Scan frequency (sampling rate): the rate at which data is sampled in the units of number of samples per second (Hz). For PCB strain gage tests, a minimum scan frequency of 500 Hz is recommended, although typical scan frequencies range from 500 Hz to 2 khz. Sampling Resolution: refers to the number of bits of the analog-to-digital converter (ADC) in the data acquisition hardware. The higher the resolution, the smaller the input signal changes that can be detected and the more accurate the measurement carries. For PCB strain gage tests, a minimum sampling resolution of 12 to 16 bits is recommended. Number of Channels: the number of available monitoring channels limits the number of measurements in one pass. At least 12 measurement channels are required to monitor four stacked rosettes mounted at all corners of a BGA chip, and at least three channels are required to measure one stacked rosette. While it can make multiple passes if there are insufficient channels, it must monitor all three gages in any stacked rosette at the same loading to avoid any strain calculation errors during analysis. Simultaneous Sampling: it must monitor all three gages in a stacked rosette at the same loading and in the same pass. The data acquisition device dictates how can take these measurements. Two of the common techniques are multiplexing and simultaneous sampling. Data acquisition devices that offer multiplexing feature one ADC and sample channels sequentially. For PCB strain gage tests, sequential sampling may result in miscalculated strain values. Data acquisition devices with simultaneous sampling offer an individual ADC per channel, resulting in measurements taken on all channels at the exact same time and eliminating any errors in strain calculations. Bridge Completion and Excitation Voltage each of the three individual gages in a stacked rosette is a quarter-bridge gage that requires bridge completion and excitation voltage both of which are provided by the data acquisition instrumentation to function. Bridge completion for a quarter-bridge strain gage sensor includes providing three of the four arms of a Proceedings of SMTA International, Sep. 25-29, 2016, Rosemont, IL, USA Page 489

Wheatstone bridge (see Figure 3), where the gage acts as the fourth arm. Figure 3: Wheatstone Bridges Step 4: Analyze and Report Data Once it have acquired the raw strain data, it can begin the last step of the PCB strain gage test analyzing this data to calculate resultant stresses (maximum and minimum) induced on the board during the test. We can complete this analysis online during the test or offline after the test has finished and have collected all of the data. Analysis details vary with the particular strain limit criteria we are using. Many strain limit criteria may require obtaining strain rates or principal strain calculations using Mohr s circle equations. According to the IPC-9704 guideline, at a minimum, it should provide the peak values of the principal or axial strain (maximum and minimum) for each step monitored. A common way to report data is with a strain versus strainrate chart, where the y-axis represents maximum allowable principal strain and the x-axis represents strain rate. Strain rate is the change in the absolute value of strain between consecutive readings. APPLICATION OF STRAIN GAGE TEST IN PCBA MANUFACTURING PROCESS A typical case of strain damage evaluation for PCBA assembly process was analyzed as follows, focusing on the application of the strain gage technology as well as on the basic thinking about solving such problems. Testing Samples and Background The failure sample board was designed for daughter-mother board structure. The daughter board which made-up design for the four sub-boards layout, reflowed and then mounted on the motherboard by hand soldering. The failure BGA located at the edge of the daughter board. The cross section analysis showed that cracks were found in failure BGA solder joints. The failure solder joints matrix map was detailed in Figure 4. The principal crack mode was the crack between solder ball and BGA pad. Pad crater was detected in few solder joints. All the cracks occurred in BGA corner position where the stress was more centralized. The representative cross section views were shown in Figure.5. (a) Top Side (b) Bottom Side Figure 4: Matrix Map of BGA Failure Solder Joints (a) Cracking Between Solder Ball and BGA Pad (b) Pad Crater Crack Pad Crater Figure 5: Representative Section Views of Cracking Solder Joint Furthermore, the SEM inspection results showed that the cracking was between intermetallic compound (IMC) and nickel layer of BGA pad. The IMC layer either in BGA component side or in PCB pad side was uniform and continuous, with moderate thickness which directed the soldering process was desirable. The representative SEM views were shown in Figure 6. In addition, BGA package was found no evidence of significant deformation, and the height of BGA solder balls was uniform. It can exclude the influencing factors resulted from soldering thermal stress. Therefore, it has reason to suspect that the stress came from the assembly mechanical stresses. The typical high-risk stress step comprises V-cut separation, shield, covered, tighten, split cover and so on. The above processes need to be through the strain measuring technology one by one investigation and analysis [7]. Proceedings of SMTA International, Sep. 25-29, 2016, Rosemont, IL, USA Page 490

(3) Strain measurement For the typical mechanical assembly process (thread locking process), the scan frequency was chosen as 500Hz. The excitation voltage was chosen as 2V for the PCB material. Three monitoring channels and six monitoring channels were used in one pass for case 1 and case 2, respectively. Figure 6: Representative SEM Views of Cracking Solder Joint Testing Procedures (1) Strain gage selection Considering the character of the PCBA samples in this strain gage testing case, the information of the strain gages selected is listed as follows: gage type (three elements stacked rectangular (0 /45 /90 ) rosette strain gage), dimension (5mm*5mm), gage resistance (350Ω). (2) Strain gage attachment Quarter-bridge connection was applied for this test. The gage placement is with the gage substrate edge no more than 1.0mm away from each end of the component, aligned along the component length, as shown in Figure 7. 6 Figure 7: Gages Placement 3 4 5 1 2 (4) Data analysis Data analysis is the last step for strain measurement. Depending on the criteria, the peak values (maximum and minimum) of the principal or diagonal strain should be given for each step monitored. The maximum and minimum principal strains can be obtained by Strain Mohr circle analytical method, and the computation formula is as follows. 0 90 2, ( ) 2 ( ) 2 (1) max min 2 2 0 45 45 90 After the data analysis step, a comprehensive analysis and risk assessment should be conducted for the PCBA samples, in order to propose the corresponding improvement measures. Results and Suggestion According to the above measurement steps, after preparing PCBA samples and connecting the strain gages to the data acquisition instrument, the high-risk steps were conducted for the PCBA samples one by one and the strain-time data was obtained for the testing points, respectively. Depending on the second strength theory, the maximum principal strains were calculated by Strain Mohr circle analytical method (see Eq. (1)). Table 1 detailed the specific data analysis results for the different steps. The variation of maximum principal strain with time of V-cut separation were shown in Figure 8. The test results indicated that V-cut separation was the highest risk process for strain-induced damage. The maximum strain value of V-cut separation (above 6000μE ) was even more than 10 times the industry standard (600μE). Obviously, it is necessary to change the board separation method to eliminate the influence of the over stress. Table 1: Strain Gage Test Results Step Max. Strain Value (μe) 1 2 3 4 5 6 V-cut Separation 6507 362 3555 1602 6181 5242 Shield - - 115 94 - - Cover - - 190 234 - - Tighten - - 156 35 - - Split Cover Note - - 152 108 - - - : strain effect can be ignored. Proceedings of SMTA International, Sep. 25-29, 2016, Rosemont, IL, USA Page 491

1 2 3 Figure 10: Variation of Maximum Principal Strain with Time (Stamp Hole Separation) The use of machinery board separation (see Figure 11) to place manual board separation method, the stain-induced damage further declined. The variation of strain with time was shown in Figure 12. 4 5 Figure 11: Machinery Separation 6 Figure 8: Variation of Maximum Principal Strain with Time Modify the PCB design from the V-cut slot to stamp hole, as shown in Figure 9. Then prepared the sample and connected the strain gage to the data acquisition instrument, the strain gage test started with board separation process. The variation of maximum principal strain with time was shown in Figure 10. The result showed that the maximum strain reduced to about 700μE significantly. Figure 9: Stamp Hole Design Figure 12: Variation of Maximum Principal Strain with Time (Machinery Separation) Obviously, by the stain measurement technology, the root cause for solder joint cracking failure was found, the high risk process was identified and corrected based on the failure cause and then was validated effectively with the aid of strain gage test. Thus the quality risk was avoided, and the products reliability was guaranteed. CONCLUSION PCBAs and components deformation control using strain gage measurement is proven beneficial to the electronic assembly industry, which can be used as a method to identify and improve manufacturing operations that may pose a high risk for interconnect damage. Proceedings of SMTA International, Sep. 25-29, 2016, Rosemont, IL, USA Page 492

This article studied on the application of strain measuring technology in PCBA reliability evaluation, such as the strain gage selection technology for PCBA, specific operation method of strain gage tests during PCBA assembly process and strain data analysis method. Accordingly, electronic process related technical personnel can quickly and reliably establish related evaluation scheme, and continue to identify and control the risky PCBA manufacturing process. The study on strain measurement for lead-free PCBAs in electronic industry has just started and there are still many unsolved puzzles. Facing to this new and challenging research field, there are many more to explore for PCBA strain/stress damage mechanism and evaluation method. ACKNOWLEDGEMENTS This research work was supported by the National Natural Science Foundation of China (Grant No. 51304176), Guangdong Provincial Public Welfare Research and Capacity Building Special Fund Project (Grant no. 2015A030401022). REFERENCES [1] J. Wang, P. He, and F. Xiao, The effect of residual stress on the flexing strength of PCB assembly, High Density Microsystem Design and Packaging and Component Failure Analysis, 2004. HDP'04. Proceeding of the Sixth IEEE CPMT Conference, PP 146-150. [2] D. A. Shnawah, M. F. M. Sabri and I.A.Badruddin, A review on thermal cycling and drop impact reliability of SAC solder joint in portable electronic products, Microelectron Reliab., vol. 52, pp. 90-99, 2012. [3] F.Liu, G. Meng, M. Zhao and J. F. Zhao, Experimental and numerical analysis of BGA lead-free solder joint reliability under board-level drop impact, Microelectron Reliab., vol. 49, pp. 79-85, 2009. [4] L. L. Mercado, S. Girouard and G. Hsieh, Electronic packaging solder joint reliablity assessment with a mechanics-based strain gage methodology, IEEE T. Compon. Pack. T., vol. 29, pp. 5-12, 2006. [5] H. Shi, J. Wu and J. Zhang, Research on Selection Method of Resistance Strain Gages for PCB, Semiconductor Technology, vol. 34, pp. 981-985, 2009. (in Chinese) [6] IPC/JEDEC-9704. Printed circuit assembly strain gage test guideline [S]. Northbrook, Illinois, 2011. [7] E. Wong and C. Wong, Approximate solutions for the stresses in the solder joints of a PCB subjected to mechanical arching, International Journal of Mechanical Sciences, vol. 51, pp. 152-158, 2009. Proceedings of SMTA International, Sep. 25-29, 2016, Rosemont, IL, USA Page 493