CORAIL Hip System. Clinical Summary

Similar documents
Acetabular Cup System. Clinical Summary

PINNACLE Acetabular Cup System

SUMMIT and DURALOC. Clinical Summary

Femoral Revision Algorithm. A practical guide for the use of the CORAIL Hip System in femoral revision surgery

CHARNLEY Wires. Surgical Techniques

JOINT RECONSTRUCTION PORTFOLIO OVERVIEW

AUTOBLOQUANTE AUTOBLOQUANTE. Product Rationale Surgical Technique

This publication is not intended for distribution in the USA.

Approach Patients with Confidence

THE ATTUNE REVISION FIXED BEARING KNEE SYSTEM

)501( COPYRIGHT 2018 BY THE ARCHIVES OF BONE AND JOINT SURGERY

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

NEUFLEX MCP/PIP FINGER JOINT IMPLANT SYSTEMS SURGICAL TECHNIQUE. This publication is not intended for distribution in the USA.

THE ATTUNE REVISION ROTATING PLATFORM KNEE SYSTEM

DEPUY SYNTHES SOLUTIONS

Product Rationale. Where Strength and Modularity Connect

DEPUY SYNTHES SOLUTIONS

FIXATION FIRST WEAR REDUCTION OXIDATIVE STABILITY MECHANICAL INTEGRITY PROVEN TECHNOLOGY

PRODUCT RATIONALE & SURGICAL TECHNIQUE

Move Ahead with Confidence. Hip Replacement Solutions from DePuy Orthopaedics

CORAIL UPGRADE KIT. This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

CORAIL Upgrade Kit. Surgical Technique

Trusted technology. Trusted performance. Supporting healthcare professionals

Featuring. Technology. Product Rationale

Optimizing function Maximizing survivorship Accelerating recovery

Outcomes Following Total Hip Arthroplasty: A Review of the Registry Data

Optimum implant geometry

Produced on: Licenced for use until: Corail Stem (Standard Offset Collared)

Produced on: Licenced for use until: Corail Stem (Standard Offset Non-Collared)

SMARTSET Bone Cements. Product Information

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

DePuy Corail Collared vs. Collarless (ex MoM)

CERAMIC-ON-METAL. References: Cat No: version 2

CORAIL HIP SYSTEM DESIGN RATIONALE

DePuy CMW Heritage Bone Cements. Product Information

Optimum implant geometry

SELF-CENTERING Bipolar/Modular Cathcart Unipolar

2016 CELEBRATING 15 YEARS OF DATA REPORT NATIONAL JOINT REPLACEMENT REGISTRY. Metal and Ceramic Bearing Surface in Total Conventional Hip Arthroplasty

Exeter. Designed for Anatomic Restoration. Clinical Evidence Education

PINNACLE REVISION CUP SYSTEM

Gender Solutions Patello-Femoral Joint System

BRITISH HIP SOCIETY. Annual Scientific Meeting 2019 Nottingham, Concert Hall. Registration from with Refreshments

Smith & Nephew. R3 Cementless Cup

National Joint Replacement Registry. Metal and Ceramic Bearing Surface in Total Conventional Hip Arthroplasty

ACTIS. TOTAL HIP SYSTEM Approach Active Patients with Confidence DESIGN RATIONALE

CORAIL REVISION STEM. This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

CUTTING GUIDE SYSTEM PRODUCT RATIONALE. Custom-Made Patient Instruments for Total Knee Replacement

The Experience in Exeter with. hip fracture care. Data For Change

DURALOC. Acetabular Cup System. Surgical Technique

REVISION. Zimmer Biomet All Trabecular Metal Cups vs. All non-tm cementless cups

VERSALOK SURGICAL TECHNIQUE FOR ROTATOR CUFF REPAIR SURGICAL TECHNIQUE VERSATILITY STRENGTH SPEED

CORAIL Revision Hip System. Surgical Technique

The science of simplicity

Developmental Dysplasia of the Hip Good Results of Later Total Hip Arthroplasty

simplicity THE SCIENCE OF DESIGN RATIONALE

THE PERSONALIZED KNEE

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

Distally-Interlocked Modular Femoral Reconstruction Prosthesis

Approach Patients with CONFIDENCE

Informed Consent for HRA

Smith & Nephew. Polarstem Cementless

Tri-Lock Bone Preservation Stem

Triple Tapered Stabilised Hip C-STEM AMT. Surgical Technique

TOTAL HIP REPLACEMENT:

Summary of Arthroplasty Registry Reports of

Templating and Pre Operative Planning 2. Preparation of the Acetabulum 4. Trial Sizing and Impaction of the Shell 5.

DISCLOSURE FNFX ORIF OR ARTHROPLASTY? 11/21/2016 FEMORAL NECK FRACTURES: ORIF OR ARTHROPLASTY? ROYALTIES DEPUY, BIOMET

Bone Preservation Stem

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

Approach Patients with Confidence

National Joint Replacement Registry. Lay Summary 2015 Annual Report Hip and Knee Replacement

Case report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis?

DEPUY SYNTHES JOINT RECONSTRUCTION PATIENT EDUCATION SEMINAR

NJR 2009 NJR Activity 2008 Keith Tucker Survivorship Analysis Martyn Porter Outliers Paul Gregg Clinician Feedback Peter Howard

MARATHON Cross-Linked Polyethylene

National Joint Registry for England and Wales 3rd Annual Clinical Report

CORAIL Hip System. Product Rationale and Surgical Technique

CORAIL Hip System. Product Rationale and Surgical Technique

Clinical Study Mean 5-Year Clinical and Radiographic Outcomes of Cementless Total Hip Arthroplasty in Patients under the Age of 30

Operations included in the National Joint Registry (NJR) Quick links, go to: Hips > Knees > Ankles > Elbows > Shoulders > Trauma >

RECLAIM REVISION HIP SYSTEM

RECLAIM REVISION SOLUTIONS

G7 ACETABULAR SYSTEM. beautifully. efficient.

Understanding Hip Implant Options

Are there limits for a cementless short hip stem?

DePuy Attune CR and Attune PS

CORAIL HIP SYSTEM SURGICAL TECHNIQUE

Optimum implant geometry

HP KNEE EXTRACTION Instrumentation. Product Overview

Increased Rate Of Dislocation Of Total Hip Arthroplasty With Cementless Implants: Accuracy Of Acetabular Inclination.

Cemented Thompson versus cemented bipolar prostheses for femoral neck fractures

RM Philosophy Innovation based on clinical evidence.

DePuy Attune CR and Attune PS. Contents Recorded Usage in NJR Patient and Procedure Details Revision and Survivorship APPENDIX A Component List

Experimental Prediction of Contact Area in Hip Replacement and Hemi- Arthroplasty

DOWNLOAD OR READ : TECHNIQUES IN REVISION HIP AND KNEE ARTHROPLASTY PDF EBOOK EPUB MOBI

DePuy Attune CR and Attune PS. Contents Recorded Usage in NJR Patient and Procedure Details Revision and Survivorship APPENDIX A Component List

A RETROSPECTIVE COHORT STUDY OF MEDIUM-TERM DATA FROM A NATIONAL JOINT REGISTRY

HIP CONTINUUM OF CARE. Trauma and Joint Reconstruction Hip Portfolio

Transcription:

CORAIL Hip System Clinical Summary

25-year ARTRO Results: A Special Vintage from the Old World Vidalain, J-P The CORAIL Hip System: A Pratical approach based on 25 years of experience. 2011; Chapter 4.2.1:94-101 6 347 CORAIL stems were implanted in 320 patients between July 1986 and December 1990. The mean follow up of the cohort is 20.9 years. Only 12 stems (3%) were revised, and 7 of these were well-fixed stems that were removed to facilitate acetabular revision. When all causes of stem removal were considered, the CORAIL stem survival in this series was 97.7% at 15 years, 96.8% at 20 years and 96.3% in the 25th year. At final follow up 83% of patients were classified as having a totally normal hip using the Sedel score. The mean Harris Hip Score was 85. Primary Collared Uncemented Total Hip Arthroplasties in the Elderly: A Safe and Reliable Treatment Option Schaller G, Black J, Asaad A, Harper N, Webb S, Muirhead-Allwood S. The Journal of Arthroplasty 30 (2015) 407-410. 7 A consecutive cohort of 153 patients aged over 80 years were included in this study. The mean age was 84.5 (range 80-95 years) and 120 (78% ) were females. 144 patients received a collared CORAIL stem. The mortality rate at 90 days was 0.65%. Only one patient required revision, due to a dislocation following trauma. The Oxford Hip Score improved from a mean of 24 (range 4-41) pre-operatively to a mean of 46 (range 9-48) at 90 days. This study demonstrates the successful use of a collared cementless implant in an elderly population, with excellent short-term postoperative complication rate, low mortality rate and good functional outcomes.

Over the last 15 years, the PINNACLE Acetabular Cup System has been provided to over 2,300,000 patients. 1 The CORAIL hip system celebrated 30 years in 2016, and in that time has been provided to over 1,800,000 patients. 1 10 CORAIL HIP SYSTEM & PINNACLE HIP Solutions 10A* CORAIL, CORAIL AMT Total Hip System and PINNACLE Cementless Acetabular Cup 3A* CORAIL Cemented Total Hip System, PINNACLE GRIPTION Acetabular System In 2015 the CORAIL and CORAIL AMT Total Hip System and the PINNACLE Cementless Acetabular Cup were awarded an ODEP 10A* ratings by the Orthopaedic Data Evaluation Panel. 2 Australian Orthopaedic Association National Joint Replacement Registry Data for the CORAIL/PINNACLE Combination According to the 2016 AOANJRR annual report, the CORAIL PINNACLE combination is the most implanted combination in cementless total hip replacement across Australia. 3 Combination Total Year 1 Year 5 Year 10 CORAIL, PINNACLE 29,292 1.6% (1.5%, 1.8%) 3.0% (2.8%, 3.2%) 4.9% (4.3%, 5.7%) National Joint Registry for England, Wales, Northern Ireland and the Isle of Man. Registry Data for the CORAIL/PINNACLE Combination Based on the 2016 Annual Report, CORAIL PINNACLE was the most implanted combination in total hip replacement across England, Wales, Northern Ireland and the Isle of Man. 4,5 Combination Implantations Year 3 Year 5 Year 10 CoC 35,092 1.78% (1.64%-1.94%) 2.38% (2.20%-2.57%) 4.00% (3.38%-4.74%) CoP 16,320 1.26% (1.07%-1.48%) 1.90% (1.61%-2.24%) 2.81% (2.13%-3.72%) MoP 42,469 1.42% (1.30%-1.55%) 1.77% (1.62%-1.93%) 3.16% (2.72%-3.66%) * blue italics signify that fewer than 250 cases remained at risk at these time points

CORAIL uncemented hemiarthroplasty with a Cathcart head for intracapsular hip fractures B. J. L. Kendrick, H. A. Wilson, J. E. Lippett, A. R. McAndrew, A. J. M. D. Andrade. Bone Joint J 2013;95-B:1538-43. 8 A total of 306 patients received a Cathcart modular head on a collared CORAIL uncemented stem as a hemi-arthroplasty. The mean age of the patients was 83.3 years (range 46.6 to 94) and 216 (70.6%) were women. The mortality rate at 30 days was 5.8% which compares well to the 2011 NICE guidelines. 2 patients required revision to THR and in both cases this was due to continued deterioration of the acetabulum The primary aim of hemi-arthroplasty is to allow early mobilization and a return to normal activity. Within this study a total of 46.5% of patients returned to their own home by 30 days, which increased to 73.2% by 120 days. At one year a high proportion of patients had achieved their pre-fracture mobility rate. Using a modern uncemented hip implant in a hemi-arthroplasty for intracapsular hip fracture provided satisfactory results, with a good rate of return to pre-injury place of residence and an acceptable mortality rate. Hip arthroplasty in patients younger than 30 years: excellent ten to 16-year follow-up results with a HA-coated stem Wangen H, Lereim P, Holm I, Gunderson R and Reikerås O. Int Orthop. 2008 Apr; 32(2): 203 208. 9 A total of 49 uncemented THRs were performed using the CORAIL stem in 44 patients aged under 30 years (mean 25, range 15-30). At a mean follow up of 13 years the survivorship of the femoral stem was 100%. 100% of stems were well integrated, with no signs of radiological loosening and no signs of subsidence. The study reports excellent Harris Hip Scores (Mean 90, range 62-100)

References 1. 1986-2015 sales data on file, DePuy International Ltd. 2. Orthopaedic Data Evaluation Panel. ODEP product ratings. Latest ODEP ratings can be found at www.odep.org.uk [Accessed 01/10/2015]. 3. Australian Orthopaedic Association National Joint Replacement Registry. Annual Report. Adelaide: AOA; 2016. Available from URL: https://aoanjrr.sahmri.com/annual-reports-2016. Extracted from Table TY1. Table TY1 Cumulative Percent Revision of Primary Total Conventional Hip Replacement Combinations with 10 Year Data (Primary Diagnosis OA) 4. National Joint Registry for England, Wales, Northern Ireland and the Isle of Man, 13th Annual Report, 2016. Table 3.8. Available from www.njrreports.org.uk 5. National Joint Registry for England, Wales, Northern Ireland and the Isle of Man, 13th Annual Report, 2016. Table 3.9. Available from www.njrreports.org.uk 6. Vidalain JP. 25-year ARTRO Results: A Special Vintage from the Old World. The CORAIL Hip System: A Pratical approach based on 25 years of experience. 2011;Chapter 4.2.1:94-101 7. Schaller G, Black J, Asaad A, Harper N, Webb S, Muirhead-Allwood S. Primary Collared Uncemented Total Hip Arthroplasties in the Elderly: A Safe and Reliable Treatment Option. J Arthroplasty. 2015;30(3):407-10 8. B. J. L. Kendrick, H. A. Wilson, J. E. Lippett, A. R. McAndrew, A. J. M. D. Andrade. CORAIL uncemented hemiarthroplasty with a Cathcart head for intracapsular hip fractures. Bone Joint J 2013;95-B:1538-43. 9. Wangen H, Lereim P, Holm I, Gunderson R and Reikerås O. Hip arthroplasty in patients younger than 30 years: excellent ten to 16-year follow-up results with a HA-coated stem. Int Orthop. 2008 Apr; 32(2): 203 208. All analysis was carried out by DePuy Synthes, the NJR do not vouch for the accuracy of the interpretation. The third party trademarks used herein are the trademarks of their respective owners. This publication is not intended for distribution in the USA. Johnson & Johnson Medical Limited PO BOX 1988, Simpson Parkway, Livingston, West Lothian, EH54 0AB, United Kingdom. Incorporated and registered in Scotland under company number SC132162. DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN 46582 USA Tel: +1 (800) 366 8143 Fax: +1 (574) 267 7196 DePuy International Ltd St Anthony s Road Leeds LS11 8DT England Tel: +44 (0)113 270 0461 DePuy (Ireland) Loughbeg Ringaskiddy Co. Cork Ireland Tel: +353 21 4914 000 Fax: +353 21 4914 199 0086 DePuy France S.A.S. 7 Allée Irène Joliot Curie 69800 Saint Priest France Tel: +33 (0)4 72 79 27 27 Fax: +33 (0)4 72 79 28 28 0459 depuysynthes.com Johnson & Johnson Medical Limited. 2017. All rights reserved. CA#DSEM/JRC/1015/0344(1) Issued:01/17