3D ANATOMY-BASED PLANNING OPTIMIZATION FOR HDR BRACHYTHERAPY OF CERVIX CANCER

Similar documents
Dosimetric Analysis of 3DCRT or IMRT with Vaginal-cuff Brachytherapy (VCB) for Gynaecological Cancer

INTRODUCTION PATIENT. J. Radiat. Res., 52, (2011)

Basic Concepts in Image Based Brachytherapy (GEC-ESTRO Target Concept & Contouring)

Linking DVH-parameters to clinical outcome. Richard Pötter, Medical University of Vienna, General Hospital of Vienna, Austria

MRI Guided GYN Brachytherapy: Clinical Considerations

Comparison of rectal and bladder ICRU point doses to the GEC ESTRO volumetric doses in Cervix cancer

Definitions. Brachytherapy in treatment of cancer. Implantation Techniques and Methods of Dose Specifications. Importance of Brachytherapy in GYN

MR-Guided Brachytherapy

The New ICRU/GEC ESTRO Report in Clinical Practice. Disclosures

Dose-Volume Histogram Analysis in Point A-based Dose Prescription of High-dose-rate Brachytherapy for Cervical Carcinoma

Course Directors: Teaching Staff: Guest Lecturers: Local Organiser: ESTRO coordinator: Melissa Vanderijst, project manager (BE)

EMBRACE- Studien Analysen und Perspektiven

Impact of Bladder Distension on Organs at Risk in 3D Intracavitary Brachytherapy for Cervical Cancer


Course Directors: Teaching Staff: Guest Lecturers: Local Organiser: ESTRO coordinator: Melissa Vanderijst, project manager (BE)

presenting Brachytherapy with focus on Gynecological Cancers

A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 6, NUMBER 2, SPRING 2005

Image based Brachytherapy- HDR applications in Gynecological Tumors

Course Directors : Teaching Staff : Guest Lecturer: Local Organiser: ESTRO coordinators: Melissa Vanderijst and Marta Jayes, project managers (BEL)

Assessment of air pockets in high-dose-rate vaginal cuff brachytherapy using cylindrical applicators

A patient-based dosimetric study of intracavitary and interstitial brachytherapy in advanced stage carcinoma of the cervix

Recent Advances and current status of radiotherapy for cervix cancer

Version A European study on MRI-guided brachytherapy in locally advanced cervical cancer EMBRACE (ENDORSED BY GEC ESTRO)

NIH Public Access Author Manuscript Int J Radiat Oncol Biol Phys. Author manuscript; available in PMC 2015 July 01.

GOROC POSITION PAPER ON IGBT FOR CERVICAL CANCER FACULTY OF RADIATION ONCOLOGY THE ROYAL AUSTRALIAN AND NEW ZEALAND COLLEGE OF RADIOLOGISTS

Dosimetric comparison of interstitial brachytherapy with multi-channel vaginal cylinder plans in patients with vaginal tumors

GYN GEC-ESTRO/ICRU 89 Target Concept. Richard Pötter Medical University Vienna

Sigmoid Colon is an Unexpected Organ at Risk in Brachytherapy for Cervix Cancer

High dose-rate tandem and ovoid brachytherapy in cervical cancer: dosimetric predictors of adverse events

Brachytherapy Planning and Quality Assurance

Venezia Advanced Gynecological Applicator Reaching beyond

Image guided brachytherapy in cervical cancer Clinical Aspects

Local Organiser: Madhup Rastogi, Radiation Oncologist, Ram Manohar Lohia Institute of Medical Sciences, Lucknow

The Evolution of RT Techniques for Gynaecological Cancers in a developing country context

REVISITING ICRU VOLUME DEFINITIONS. Eduardo Rosenblatt Vienna, Austria

Challenging Cases in Cervical Cancer: Parametrial Boosting. Beth Erickson, MD, FACR, FASTRO Medical College Wisconsin

High resolution (3 Tesla) MRI-guided conformal brachytherapy for cervical cancer: consequences of different high-risk CTV sizes

Brachytherapy an Overview

Brachytherapy Planning and Quality Assurance w Classical implant systems and modern computerized dosimetry w Most common clinical applications w

Utrecht Interstitial Applicator Shifts and DVH Parameter Changes in 3D CT-based HDR Brachytherapy of Cervical Cancer

Evaluation of Whole-Field and Split-Field Intensity Modulation Radiation Therapy (IMRT) Techniques in Head and Neck Cancer

Chapters from Clinical Oncology

Ritu Raj Upreti, S. Dayananda, R. L. Bhalawat*, Girish N. Bedre*, D. D. Deshpande

Preliminary reports. Primoz Petric, MD, MSc, Robert Hudej, PhD, Maja Music, MD. Abstract. Introduction

BLADDER RADIOTHERAPY PLANNING DOCUMENT

Johannes C. Athanasios Dimopoulos

Advances in Gynecologic Brachytherapy

Index. T1 and T2-weighted images, 189

SYSTEMS IN BRACHYTHERAPY. Alfredo Polo MD, PhD Division of Human Health International Atomic Energy Agency

Advances in Image-guided Brachytherapy

A Study on Dosimetry of Gynaecological Cancer and Quality Assurance of HDR Brachytherapy in BPKMCH, Nepal

IMRT - the physician s eye-view. Cinzia Iotti Department of Radiation Oncology S.Maria Nuova Hospital Reggio Emilia

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Rotating-shield brachytherapy (RSBT) for cervical cancer

CT Guided Contouring: Challenges and Pitfalls

ART for Cervical Cancer: Dosimetry and Technical Aspects

University of Alberta

MRI Based treatment planning for with focus on prostate cancer. Xinglei Shen, MD Department of Radiation Oncology KUMC

Defining Target Volumes and Organs at Risk: a common language

A B S T R A C T. 1. Introduction

Role of Belly Board Device in the Age of Intensity Modulated Radiotherapy for Pelvic Irradiation

Original Article ABSTRACT INTRODUCTION

Basic Fundamentals & Tricks of the Trade for Intracavitary Radiotherapy for Cervix Cancer. Paula A. Berner, B.S., CMD, FAAMD

ESTRO-CARO Teaching Course on Image-guided cervix radiotherapy - With a special focus on adaptive brachytherapy Hilton Hotel Toronto Toronto, Canada

Review of brachytherapy in

Comprehensive and Practical Brachytherapy March 04-8 March 2018, Ljubljana, Slovenia Day 1 Sunday 4 March 2018

Specialised Services Clinical Access Policy: Enhanced Image Guided Brachytherapy (IGBT) Service for the Treatment of Gynaecological Malignancies

NIA MAGELLAN HEALTH RADIATION ONCOLOGY CODING STANDARD. Dosimetry Planning

Image guided adaptive brachytherapy in patients with cervical cancer

PRINCESS MARGARET CANCER CENTRE CLINICAL PRACTICE GUIDELINES GYNECOLOGIC CANCER CERVIX

Outline. Contour quality control. Dosimetric impact of contouring errors and variability in Intensity Modulated Radiation Therapy (IMRT)

3D CONFORMATIONAL INTERSTITIAL BRACHYTHERAPY PLANNING FOR SOFT TISSUE SARCOMA

Comparison of high-dose-rate intracavitary brachytherapy dosimetry with and without anesthesia in patients with cervical carcinoma

Nordic Society for Gynecological Oncology Advisory Board of Radiotherapy

CT Guided Contouring: Challenges and Pitfalls

The Physics of Oesophageal Cancer Radiotherapy

Specification of Tumor Dose. Prescription dose. Purpose

NEWER RADIATION (3 D -CRT, IMRT, IGRT) TECHNIQUES FOR CERVICAL CANCERS (COMMON PELVIC TUMORS)

Outline - MRI - CT - US. - Combinations of imaging modalities for treatment planning

Vaginal Sparing with Volumetric Modulated Arc Therapy (VMAT) for Rectal Cancer. Scott Boulet BSc, RT(T)

Radiotherapy physics & Equipments

Clinical implementation of multisequence MRIbased adaptive intracavitary brachytherapy for cervix cancer

Original Date: June 2013 Page 1 of 7 Radiation Oncology Last Review Date: September Implementation Date: December 2014 Clinical Operations

Brachytherapy in Africa

D. LONG, H. FRIEDRICH-NEL, L. GOEDHALS AND G. JOUBERT

A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM *

Does the apex optimization line matter for single-channel vaginal cylinder brachytherapy planning?

It s All About Margins. Maaike Milder, Ph.D. Accuray Symposium April 21 st 2018

Measurement of Dose to Critical Structures Surrounding the Prostate from. Intensity-Modulated Radiation Therapy (IMRT) and Three Dimensional

BRACHYTHERAPY IN HORSES

Changing Paradigms in Radiotherapy

Basics of Cervix Brachytherapy. William Small, Jr., MD Professor and Chairman Loyola University Chicago

Feasibility of the partial-single arc technique in RapidArc planning for prostate cancer treatment

Assessment of dose homogeneity in conformal interstitial breast brachytherapy with special respect to ICRU recommendations

Medical Dosimetry Graduate Certificate Program IU Graduate School & The Department of Radiation Oncology IU Simon Cancer Center

Radiation Planning Index for dose distribution evaluation in stereotactic radiotherapy

Can we deliver the dose distribution we plan in HDR-Brachytherapy of Prostate Cancer?

Goals and Objectives: Head and Neck Cancer Service Department of Radiation Oncology

Basics of Cervix Cancer Brachytherapy

Transcription:

SAUDI JOURNAL OF OBSTETRICS AND GYNECOLOGY VOLUME 11 NO. 2 1430 H - 2009 G 3D ANATOMY-BASED PLANNING OPTIMIZATION FOR HDR BRACHYTHERAPY OF CERVIX CANCER DR YASIR BAHADUR 1, DR CAMELIA CONSTANTINESCU 2, DR MOHAMAD EZZAT 2, MS NOOR GHASAL 2 Department of Radiology, King Abdulaziz University Hospital, Jeddah, Saudi Arabia 1 Department of Oncology, King Faisal Specialist Hospital & Research Center, Jeddah, Saudi Arabia 2 Abstract: Aim: To evaluate the dosimetric superiority of inverse planning optimization and isodose line manually optimization (both 3D planning methods) versus conventional treatment plan (point A planning method), using various dosimetric indices in HDR brachytherapy planning for cervical carcinoma. Methods and materials: The data from 10 patients treated with HDR brachytherapy for cervical cancer using tandem and ovoids has been analyzed. Target and organ at risk volumes were defined using systematic guidelines. Dose distributions were created according to three different dose calculation protocols: point A, isodose line manually optimization, and inverse planning and dose volume histograms from these plans were analyzed, and all plans were evaluated for V100%, V95%, the conformity index CI = V100%/VCTV, and the dose homogeneity index DHI = (V100% - V150%)/ V100% for target. For rectum D5cc, V50%, V70% and V100% of prescription dose were evaluated. For bladder D5cc, V50%, V80% and V100% of prescription dose were evaluated. Results: Both 3D planning methods showed significant better target coverage compared with point A calculation: average 85.65% isodose manually shaping vs. 48.43% point A calculation (p < 0.003) and 90.33% inverse planning vs. 48.43% point A calculation (p < 0.001) for V7Gy. Dose homogeneity was better for both 3D planning protocols: average 0.33% isodose manually shaping vs. 0.39% point A calculation (p < 0.008) and 0.31% inverse planning vs. 0.39% point A calculation (p < 0.031) for DHI. For organs at risk, point A calculation average was 4.29 Gy vs. 4.99 Gy isodose manually shaping (p < 0.037) and 4.29 Gy point A calculation vs. 5.14 Gy inverse planning (p < 0.013) for D5cc of rectum; and average 4.88 Gy point A calculation vs. 6.32 Gy isodose manually shaping (p < 0.019) and 4.88 Gy point A calculation vs. 5.78 Gy inverse planning (p < 0.019) for D5cc of bladder. Conclusion: The 3D planning methods improve dose conformity and homogeneity of target coverage while minimizing dose to critical structures by chosen the appropriate priorities and allows for easy comparison between patients. Keywords: Cancer cervix, inverse planning, Brachytherapy Address for Correspondence: Dr. Yasir Bahadur, Department of Radiology, King Abdulaziz University Hospital, P.O. Box 6615, Jeddah 21452, Saudi Arabia Fax: 0096626408047 E-mail: yasirbahadur@hotmail.com 27

3D ANATOMY-BASED PLANNING OPTIMIZATION FOR HDR BRACHYTHERAPY OF CERVIX CANCER Dr Yasir Bahadur, Dr Camelia Constantinescu, Dr Mohamad Ezzat, Ms Noor Ghasal Introduction: Brachytherapy has been a standard component of radiation therapy for cervical cancer since shortly after the discovery of radium. Dose optimisation in brachytherapy is not a new concept and has been studied for more than 70 years. The reasons why this has only relatively recently become a topic for widespread study, is due to technological advances both in computing power and in imaging possibilities in 3D such as with CT and MRI. In the particular case of cervix cancer, although there have been several different applicator systems and prescription methods, variations of the Manchester system have been the most commonly used. Dose prescription guidelines for this system are described in the ICRU report No. 38. Although these systems have provided a large body of well-documented clinical experience to support general prescription guidelines, there are limitations of these methods that likewise have been well documented (1, 2). With the development of CT and MRI, compatible applicators, and computerized 3D treatment planning, it is now possible to obtain much more detailed information regarding tumor coverage and dose to nearby critical structures. Several authors have documented the underestimation of dose to bladder and rectum predicted by the Manchester system (3 6). To address the inadequacies of traditional planning methods, three-dimensional treatment planning systems and anatomy-based planning optimization for brachytherapy are becoming available. Systematic guidelines for target delineation and dose constrictions have not yet been established for each disease site using anatomy-based planning systems. In clinical practice, dwell positions or/and time values are usually adjusted manually. These optimization methods are therefore highly operator dependent, and practical guidelines to determine the dwell positions or to optimize the dwell time of each dwell position have not been clearly established. Moreover, some available methods, such as geometric and dose-point optimization are based on the location of the active dwells, failing to use anatomic information. To address these inadequacies, different anatomy-based inverse planning algorithms have been developed, governed by prescribed dose constraints on each anatomic volume. The purpose of this study is to retrospectively evaluate the dosimetric superiority of inverse planning optimization and isodose line manually optimization (both 3D planning methods) versus conventional treatment plan (point A planning method), using various dosimetric indices in HDR brachytherapy planning for cervical carcinoma. In this study we describe and compare two methods of 3D dose optimization with the traditional method of prescribing dose for the tandem and ovoids applicator in cervical cancer. This comparison is made by analyzing dose distributions to target and organ at risk volumes, comprehensive constraint definitions, target coverage, dose homogeneity, and OAR sparing. Methods and materials: We retrospectively analysed the data from 10 patients treated in our radiation therapy unit with HDR brachytherapy for cervical cancer using tandem and ovoids. The patients have been randomly selected. Target and organ at risk volumes were defined using systematic guidelines (1, 2). The FIGO staging of these ten patients were as follow; one case was stageib2, 5 stages IIB, 1 stage IIIA, 2 stage IIIB and 1 stage VIA. All patients received External Beam Radiotherapy(EBRT) a dose of 45 Gy in 25 fractions over 5 weeks with concomitant weekly Cisplatin, followed by three fraction of 7 Gy weekly using Fletcher Suit Device (FSD). Target delineation: In this study, the clinical target volume included: the gross tumor volume, entire uterus, cervix, ovoids, and vaginal extent of the tumor. The entire uterus was chosen to safely encompass all tumours while reducing the risk of a geographic miss. Organ at risk volumes included the bladder and rectum. The entire bladder was contoured and the rectum was contoured 2cm below the ovoid till the recto-sigmoid flexure. No walls have been contoured for the organs at risk. CT based planning was performed on Varian Brachyvision planning system, version 8.0, for Varian HDR VariSource 200. The clinical target volume (CTV) and organs at risk (OAR) of bladder and rectum were delineated. For each patient, 3 plans were made. The prescription dose was 7 Gy. Dose distributions were created according to three different dose calculation protocols: point A, isodose line manually optimization, and inverse planning. Point A calculation protocol is the conventional treatment planning, prescribing the dose at point A and assuming equal times for all dwell positions. Isodose line manually optimization was used as an alternative planning method; it is a 3D planning method and consists in manually shaping the isodose lines, using a free hand tool of the planning system. The treatment planning system automatically calculates the dwell times accordingly. The isodose lines shaping was performed by a physician. Inverse planning identifies the combination of dwell times that best conforms to dose constraints of target volume and critical organs. After the volumes of interest are contoured, dose constraints are given to dose calculation within each volume. Once the volumes of interest are drawn and the dose constraints are set, the inverse planning algorithm is run to calculate the optimal dwell times that fulfil the dose constraints. The dose constraints used in our study were: For CTV: 95% of the volume to receive 7 Gy and 100% of the volume to receive 6.65 Gy (95% of the prescribed dose) (as a minimum). For rectum: 5% of the volume to receive 4.9 Gy (70% of the prescribed dose) and 100% of the volume to receive 3.5 Gy (as a maximum). For bladder: 5% of the volume to receive 5.6 Gy (80% of the prescribed dose) and 100% of the volume to receive 4 Gy (as a maximum). 28

SAUDI JOURNAL OF OBSTETRICS AND GYNECOLOGY VOLUME 11 NO. 2 1430 H - 2009 G The constraints for the organs at risk were set to have 100% priority, while for the CTV were set with 50% priority. The dwell time constraints were set at 300 s The algorithms used by both isodose line manually shaping and inverse planning protocol are beyond the scope of this study. Dose distributions and dose volume histograms from these plans were analyzed, and all plans were evaluated using following indices: the volume receiving 100% of prescription dose V100%, the volume receiving 95% of prescription dose V95%, the conformity index CI = V100%/ VCTV, and the dose homogeneity index DHI = (V100% - V150%)/ V100% for target. For rectum, the doses received by volume of 5 cm3 (D5cc) and volumes receiving 50% (V50%), 70% (V70%) and 100% (V100%) of prescription dose were evaluated, and for bladder, the doses received by volume of 5 cm3 (D5cc) and volumes receiving 50% (V50%), 80% (V80%) and 100% (V100%) of prescription dose were determined. The statistical analysis was done using the Wilcoxon matched pairs test and a p value of < 0.05 was considered significant. Results: Dose distributions and dose volume histograms were generated for the target and organs at risk for all patients and all calculation protocols, as shown in Fig. 1.-3. The mean values with standard deviation for all dosimetric indices are given in (Table 1), as well as the p value generated by Wilcoxon matched pairs test. The point A calculation protocol has been considered as baseline of reference. Comparison of dose optimization methods in HDR brachytherapy for cervix cancer (table1) with 50 % priorities to CVT versus 100 % for the OAR Dose volume histogram analysis showed that both 3D planning methods indicated significant difference in clinical tumor volume prescription dose coverage compared with point A calculation: average 85.65% isodose manually shaping vs. 48.43% point A calculation (p < 0.003) and 90.33% inverse planning vs. 48.43% point A calculation (p < 0.001) for V7Gy. Also, the dose homogeneity was better for both 3D planning protocols: average 0.33% isodose manually shaping vs. 0.39% point A calculation (p < 0.008) and 0.31% inverse planning vs. 0.39% point A calculation (p < 0.031) for DHI. No statistical significance was found between isodose manually shaping and inverse planning FIG. 1. POINT A CALCULATION PROTOCOL FIG. 2. ISODOSE LINE MANUALLY SHAPING 29

3D ANATOMY-BASED PLANNING OPTIMIZATION FOR HDR BRACHYTHERAPY OF CERVIX CANCER Dr Yasir Bahadur, Dr Camelia Constantinescu, Dr Mohamad Ezzat, Ms Noor Ghasal regarding the dose homogeneity index (p < 0.546). For the organs at risk considered in this study, point A calculation method showed to provide better sparing then both 3D planning methods: average 4.29 Gy point A calculation vs. 4.99 Gy isodose manually shaping (p < 0.037) and 4.29 Gy point A calculation vs. 5.14 Gy inverse planning (p < 0.013) for D5cc of rectum; and average 4.88 Gy point A calculation vs. 6.32 Gy isodose manually shaping (p < 0.019) and 4.88 Gy point A calculation vs. 5.78 Gy inverse planning (p < 0.019) for D5cc of bladder. Again, the difference between isodose manually shaping and inverse planning regarding the sparing of organs at risk was not statistically significant (p < 0.165 for D5cc of rectum and p < 0.919 for D5cc of bladder). Discussion: Brachytherapy has been a standard component of therapy for carcinoma of the cervix for over 100 years. Although the Manchester system of prescribing to point A has been widely used for treatments with tandem and ovoids, several authors have questioned the accuracy of this planning method in terms of target coverage and dose to critical nearby structures (3, 5, 8, 9). In particular, the method described in ICRU report No. 38 dictates dose distributions based on the visualization of the applicator and bony landmarks rather than coverage of the tumor and critical structures (3). With the advent of CT-based treatment planning systems, these controversial issues can be quantitatively addressed. FIG. 3. INVERSE PLANNING Table 1. Comparison of dose optimization methods in HDR brachytherapy for cervix cancer Isodose manually shaping (b) Inverse planning (c) p (a-b) p (a-c) p (b-c) CTV V 7Gy (%) 85.65 + 8.25 90.33 + 7.97 0.003 0.001 0.275 V 95% (%) 88.2 + 7.6 91.61 + 7.21 0.003 0.001 0.556 CI (%) 0.85 + 0.08 0.90 + 0.07 0.003 0.001 0.275 DHI (%) 0.33 + 0.09 0.31 + 0.11 0.008 0.031 0.546 Rectum D 5cc (Gy) 4.99 + 1.05 5.14 + 7.97 0.037 0.013 0.919 V 50% (%) 34.91 + 14.09 38.16 + 7.21 0.027 0.011 0.244 V 70% (%) 11.67 + 7.93 12.96 + 19.04 0.004 0.009 0.431 V 80% (%) 4.44 + 4.56 6.26 + 2.31 0.013 0.013 0.184 V 100% (%) 1.22 + 0.98 1.87 + 7.73 0.652 0.148 0.695 Bladder D 5cc (Gy) 6.32 + 4.19 5.78 + 3.17 0.019 0.019 0.232 V 50% (%) 49.77 + 28.23 51.76 + 13.63 0.013 0.013 0.198 V 80% (%) 15.88 + 20.32 11.01 + 24.28 0.006 0.012 0.155 V 100% (%) 7.04 + 17.96 3.79 + 12.51 0.078 0.954 0.148 30

SAUDI JOURNAL OF OBSTETRICS AND GYNECOLOGY VOLUME 11 NO. 2 1430 H - 2009 G The important next step to these studies documenting the inadequacies of the ICRU prescription method is to determine whether something can be done to improve on it. As the use of anatomy-based treatment planning for HDR brachytherapy of the cervical carcinoma becomes more widely used, a systematic method of dose optimization is important for quality assurance, reproducibility, and respect of time restrictions. Currently available optimization schemes, such as geometric and dose point optimization, fail to use the anatomic information. Because these optimizations are based only on the location of the active dwells, these methods necessarily result in an approximation of the shape of the anatomy. Reducing the clinical target volume to a geometric representation without regard to anatomic relationships can result in a poor coverage of the target and an overdosage of normal tissues. To maintain complete coverage of the tumor and simultaneously reduce the dose to normal organs at risk of radiation injury, the dose distribution should be as conformal as possible to the relevant anatomy. Alternatively, dose distribution can be manually obtained by adjusting relative dwell time values until an acceptable solution is found; computer is used only to calculate the dose distribution once the plan has been decided by the dosimetrist. This approach, or the combination of this approach with geometric optimization, requires more time and skill. A better and more efficient planning system would mean replacing manual planning with a computer optimization program that integrates scan based anatomic information. The current commercial planning systems cannot be truly anatomy based without a genuinely anatomy-based optimization. An important distinction must be made between a planning system where doses are optimized based on anatomic structures vs. a geometrically optimized planning system where doses are optimized based on location of the active dwells. Employment of anatomy-based optimization is the final step toward truly anatomy-based planning. This approach brings the planning process nearest to the real clinical issues. In this study we described and compared two methods of 3D dose optimization (isodose line manually shaping and inverse planning) with the traditional method of prescribing dose for the tandem and ovoids applicator in cervical cancer (point A planning method), by retrospectively analyzing dose distributions to target and organ at risk volumes, using various dosimetric indices. Both 3D planning methods proved to provide superior dosimetric target coverage than conventional treatment plan (point A planning method). However, this improvement in target coverage was associated with slightly more dose to organ at risk Kelly et al showed that inverse planning simulated annealing (IPSA) did not improve clinical tumour coverage (CTV) as compared with point A method of calculation with optimization (median 87 % Vs 82 %, p=0.36) dose to bladder and rectum were less, p=0.04 and P= 0.05 respectively. Our study did not show a similar improvement in the sparing of rectum and bladder doses which could be due to their definition of target volume which excluded the anterior and posterior vaginal walls, while in our study the target volume include all vaginal walls and this explain why in our study the inverse planning has little effect in sparing the OAR.. Also, because the 3D planning methods are independent of the dosimetrist experience, and the anatomic dose prescription does not change, plans are produced that are consistent between patients, allowing comparisons between them. With these dose 3D optimization methods, physicians have more control of the treatment. The ability to balance the target dose coverage against the dose homogeneity and the protection of organs at risk is improved and the focus becomes the physician s prescription to the target and the adjustments required to limit injury to normal structure, adapted to individual clinical circumstances. However, a note of caution must be added: in the case of isodose line manually shaping method, enabling isodoses to conform to the specific topography of the target may involve wide variations in dwell times, resulting in hot spots within the implant and the clinical consequences must be considered carefully. There are no clearly defined rules for treatment plan optimization in brachytherapy, and the exact limits of variations between dwell times are yet unknown. In this regard, software tools performing automatic optimization of the dose distribution should be used with caution. This is not the case of inverse planning method, where constraints for the dwell times can be easily set, resulting in more homogeneous dwell times and making this method to appear safer.( this means that although there is no statistically significant between the isodose manual shaping and in verse planning; the inverse planning is better and reliable The total treatment planning time for a case (including CT, contouring, dosimetry, analysis, and approval) is around 60 min for 3D planning protocols and about 45 min for point A calculation method. Conclusion: As the use of anatomy-based treatment planning for HDR brachytherapy of the cervix becomes more widely used, a systematic method of dose optimization is important for quality assurance, reproducibility, and respect of time restrictions. Although manually adjusting relative dwell time values is always an option, the 3D planning methods (isodose line manually optimization, and inverse planning) provide a reliable, fast and automatic solutions for the optimization of dose distribution by improving dose conformity and homogeneity of target coverage while minimizing dose to critical structures by chosen the appropriate priorities and allows for easy comparison between patients. The dosimetric gain achieved by inverse planning may reflect in patient treatment outcome significantly. 31

REFERECES: 1. 2. 3. 4. 5. 6. 7. 8. 9. Richard Potter et al., Recommendations from gynaecological (GYN) GEC ESTRO working group (II): Concepts and terms in 3D image-based treatment planning in cervix cancer brachytherapy 3D dose volume parameters and aspects of 3D image-based anatomy, radiation physics, radiobiology, Radiotherapy and Oncology, Vol. 78, 67 77, 2006. Haie-Meder C. et al., Recommendations from Gynaecological (GYN) GEC-ESTRO Working Group (I): Concepts and terms in 3D image based 3D treatment planning in cervix cancer brachytherapy with emphasis on MRI assessment of GTV and CTV, Radiotherapy and Oncology, Vol. 74, 235 245, 2005. Kelly D. DeWitt et al., 3D Inverse treatment planning for the tandem and ovoid applicator in cervical cancer, Int. J. Radiation Oncology Biol. Phys., Vol. 63, No. 4, 1270 1274, 2005. Etienne Lessard et al., Inverse planning for interstitial gynaecologic template: truly anatomy-based planning, Int. J. Radiation Oncology Biol. Phys., Vol. 54, No. 4, 1243 1251, 2002. G. K. Rath et al., Comparison of inverse planning optimization with classical optimization methods in HDR interstitial template Brachytherapy planning for cervical carcinoma, Int. J. Radiation Oncology Biol. Phys., Vol. 69, No. 3, 2007. D. Baltas, Optimisation - inverse optimisation and inverse planning in brachytherapy: almost a common approach to external beam, Int. J. Radiation Oncology Biol. Phys., Vol. 58, No. 4, 2002. Dietmar Georg et al., Image-guided radiotherapy for cervix cancer: high-tech external beam therapy versus hightech brachytherapy, Int. J. Radiation Oncology Biol. Phys., Vol. 71, No. 4, pp. 1272 1278, 2008. Nag S., Cardenes H., et al. Proposed guidelines for image-based intracavitary brachytherapy for cervical carcinoma: report from image-guided brachytherapy working group, Int. J. Radiat. Oncology Biol. Phys., Vol. 60, No. 4, 2004. Enrique Chajon et al., Inverse planning approach for 3-D MRI-based pulse-dose rate intracavitary brachytherapy in cervix cancer, Int. J. Radiation Oncology Biol. Phys., Vol. 69, No. 3, pp. 955 961, 2007. 32