Motorized Precision Goniometer

Similar documents
Goniometer WT-85. Goniometer WT-100. Goniometer WT-90. Goniometer WT-120. // West //

We bring quality to light. LGS 1000 Goniophotometer

Goniometer series 400

We bring quality to light. LGS 350 Goniophotometer

Standard Motorized Linear-motion stage Testing method (X axis, Y axis) Standard Motorized stage and 2-phase stepper motor/driver Cross-reference table

V New HGP 20. Standard grippers 7.5. Economical and versatile. Self centring. Choice of gripping action. Standard grippers.

Custom-Made Products / Scientific Research Instruments

Development of a Goniometer with Nanoradian Accuracy

DEVICE FOR MUSCLE COORDINATION IMPROVEMENT

People have Priority. Endodontics

LION. Application Note PRECISION. Linear Position Measurement with Eddy-Current Sensors. LA March, Applicable Equipment: Applications:

Custom Motion Systems

SpiderX. Portable Residual Stress X-Ray Diffractometer.

RiGO801 Laboratory Requirements

AMS 200. Goniophotometer for small to medium-sized lamps and modules

E200 ORT - Optical Rotary Torque Transducer. Contents

People have Priority. Endodontics

LMT-Goniophotometer GO-H 1400 Goniophotometer System for Measurement of Automotive Lamps

Custom Motion Systems

Description The 4000 Series offers up to 8600 in-lb of torque and 25 gpm (continuous ratings). This is the corner stone of the Char-Lynn line.

Type C Goniometer. Used to measure lamp and luminaire output, efficiency/efficacy, intensity distribution and zonal lumen density

MINISTAR DIGITAL AND CONTROL /// The new compact stirrers

Lexium 05 motion control

DAVIES GOLD SERIES DERMATOMES

WHITE PAPER. Efficient Measurement of Large Light Source Near-Field Color and Luminance Distributions for Optical Design and Simulation

Efficient Measurement of Large Light Source Near-field Color and Luminance Distributions for Optical Design and Simulation

Parallel-Axis Gear Terminology

AC CENTRIFUGAL FORWARD CURVED FAN 133 x 190

Maximal isokinetic and isometric muscle strength of major muscle groups related to age, body weight, height, and sex in 178 healthy subjects

Lecture 2. In The Name of Allah. Instrumentation. Dr. Ali Karimpour Associate Professor Ferdowsi University of Mashhad

Custom-Made Products / Scientific Research Instruments

TriAuto mini Compact, Cordless Endodontic Handpiece

XRAY Series Includes

Lexium 05 Servo Drives. Motion control The high concentrate solution for your machines

NC DOUBLE OPPOSING HEAD DRILL

A new geometric and mechanical verification device for medical LINACs

IES LM Test Report

Feng Xiujuan National Institute of Metrology (NIM),China

all ceramic all options The compact milling system Zenostar Telio CAD for Zenotec Your entrance into the digital world

Solar Illumination Study

Intelligent design is apparent from the detail

Installation of force transducers

Defining Cutting Edge Quality. Laser Cutting Head BIMO-FSC BIMO-FSC

CETR Adhesion Testing on Glass/Al Surface for Corning Inc.

MultiMotion. Joints for Dynamic Corrective Orthotic Systems. Our Newest Additions

Article No. see price AT4/11-2/I/S ,3 3,7 6 mm Zw = 4,9 mm AT4/11-S/I/S AT4/11-2/IA/S AT4/11-S/IA/S

POLARIS 10 SERIES. Hydraulic Gear Pumps and Motors. Max. speed. Min. speed. Theoretical displacement pressure p1

Defining Cutting Edge Quality. Laser Cutting Head BIMO-FSC BIMO-FSC

Dynamic Hollow Cylinder System Proposal

A new method of sonograph lateral resolution measurement using PSF analysis of received signal

What is a stepper motor?

Program AGMA Gear Classification and Inspection Handbook Model

Filament Fusion Splicing Workstation

Rooter S. Compact, Cordless Endodontic Motor

Force Characteristics of Trocar Insertion Abdomen in Laparoscopic Surgery

MS MS Manual Motor Starter. General Information. Ordering. Popular Downloads. Dimensions MS Extended Product Type

India s largest Fitness Equipments Showroom

First Technology Safety Systems. Design Freeze Status. Flex-PLI-GTR Development

Technical Data Sheet SONOFLOW CO.55/xxx(H) V2.0

With extended functionality the sensors are also applicable for the detection of air bubbles.

Submersible. Pumps Motors. 60Hz 4 Submersible Pump. Pumping Solution

A Guide for Choosing the Right Calibration for Torque Transducers

6 Submersible Turbine Pump

SIMULATOR FOR TESTING THE FRICTION TORQUE OF THE FEMORAL HEAD OF A HIP PROSTHESIS

ENDO-EZE TM GENIUS ENDODONTIC SYSTEM WHERE SAFETY MEETS EFFICIENCY

Liquid ring vacuum pumps single-stage

FreeMotion 7.7 R Bike

Digital Signal Processing of Optical Encoder for High Resolution Angular Measurement of X-Ray Diffraction Goniometer

MANTIS A ROBOT WITH ADVANCED LOCOMOTION AND MANIPULATION ABILITIES

10 Years Experience in Industrial Phased Array Testing of Rolled Bars

Defining Cutting Edge Quality. Laser Cutting Head BIMO-FSC

6. Gear Measurement And Testing

Oral surgery and Implantology

Technical Data Sheet SONOFLOW CO.55 V1.0

Description The 4000 Series offers up to 8600 in-lb of torque and 25 gpm (continuous ratings). This is the corner stone of the Char-Lynn line.

MS MS Manual Motor Starter. General Information. Ordering. Popular Downloads. Dimensions MS Extended Product Type

Xstress 3000 G3/G3R. X-ray Stress Analyzer. Portable X-ray diffractometer specially designed for residual stress and retained austenite measurements

MAGNUM FITNESS SYSTEMS : 5000 Series

Ultrasound in Medicine

Selection. 1 Service factor Determine the required service factor from tables 9 and 10 on pages 87 and 88.

Navigator: 2 Degree of Freedom Robotics Hand Rehabilitation Device

Mechanics and Stages for Light Measurement Applications

Rolling bearings Needle roller bearings, drawn cup without inner ring Boundary dimensions and tolerances

TRANSFORMER ALL IN ONE ISOKINETIC MACHINE ANKLE ELBOW HIP SHOULDER WRIST TRUNK

NEMA FRAME DIMENSIONS* FOOT-MOUNTED AC MACHINES

High Grade Universal Testing Machines

Online Care, Online Control, Online Confidence

POLARIS 20 SERIES. Hydraulic Gear Pumps and Motors. Max. speed. Min. speed. Theoretical displacement pressure p1

General Information. Ordering. Popular Downloads. Dimensions. Products Low Voltage Products and Systems Circuit Breakers Manual Motor Starters

Вращатели VIROSAF серии крупнейшего в мире концерна Air Liquide Welding.

1. EXECUTIVE SUMMARY 2. PRODUCT SUMMARY

[3] involuteσⅲ(worm gear design system) English version

Research on Digital Testing System of Evaluating Characteristics for Ultrasonic Transducer

INSTRUCTION MANUAL (MAN-70254)

Keylock switches for PCB

Conveyor System MM3. Chain width 83mm MODU System MM3 conveyor is also available in stainless steel. See page DM1.

Nature Neuroscience doi: /nn Supplementary Figure 1. Characterization of viral injections.

1 Service factor Determine the required service factor from tables 9 and 10 on pages 87 and 88.

ULTR A SERIES G7-S13

A Haptic Control Interface for a Motorized Exercise Machine

Transcription:

Motorized Precision Goniometer Compact, Clear Aperture WT-85 Rotation range 10 Repeatability to 8.7 µrad Load capacity to 2 kg Option: Direct position measurement with angle Combination with WT-100 with common pivot point Precision-class goniometer stage Drive with high gear ratio for precision positioning. Two limit switches. Large clear aperture with 30 mm diameter. Can be combined with WT-100 for 2-axis motion with common pivot point. Versions DC servo motor with rotary encoder on the motor shaft Stepper motor Option: High-resolution optical angle for direct position measurement Vacuum versions available on request Application fields Precision microassembly, Metrology, Photonics, Optical alignment

Specifications 65409100 65409101 65409200-0000 65409201-0001 Unit DC motor with rotary encoder DC motor with angle and rotary encoder Stepper motor Stepper motor and angle measuring system Toleranc e Active axes θ X θ X θ X θ X Motion and positioning Rotation range 10 10 10 10 Integrated sensor Sensor signal rotary encoder Sensor signal angle measuring system Sensor signal periods angle Sensor resolution rotary encoder Rotary encoder AB quadrature, RS- 422 Incremental angle Rotary encoder AB quadrature, RS- 422 Sin/cos, 1 V peakpeak Incremental angle Sin/cos, 1 V peakpeak 211 211 µrad 2000 2000 Design resolution 4.65 2.11 46.5 (full step) 2.11 µrad Counts/r ev. Minimum incremental motion 17.5 2 17.5 2 µrad typ. Unidirectional repeatability 69.8 8.7 69.8 8.7 µrad typ. Bidirectional repeatability ±69.8 ±8.7 ±69.8 ±8.7 µrad typ. Wobble ±125 ±125 ±125 ±125 µrad typ. Angular velocity 15 15 7 7 /s max. Limit switches 2 mechanical 2 mechanical 2 mechanical 2 mechanical Mechanical properties Drive screw type Ball screw Ball screw Ball screw Ball screw Drive screw pitch 1 1 1 1 mm Guide type Ball bearings Ball bearings Ball bearings Ball bearings Gear ratio 675:1 675:1 675:1 675:1 Load capacity 20 20 20 20 N max. Torque M x, power on 0.75 0.75 0.75 0.75 N m max. Permissible lateral force 15 15 15 15 N max. Permissible torque in θ y, θ z 4 4 4 4 N m max. Drive properties Motor Type DC motor DC motor 2-phase stepper motor 2-phase stepper motor Operating voltage, nominal 24 24 24 24 V nom. Operating voltage, max. 48 48 48 48 V max. Step resolution 200 200 Miscellaneous Operating temperature range 5 to 40 5 to 40 5 to 40 5 to 40 C Material Full steps/rev. Mass 0.9 0.9 0.9 1.1 kg ±5%

Connection Recommended s/drivers 65409100 65409101 65409200-0000 65409201-0001 Unit (motor/sensor) C-863 (single C-884 (up to 6 axes) 863.20C885 (to 40 axes) (motor) Sub-D 9 (m) (sensor) C-863 (single C-884 (up to 6 axes) 863.20C885 (to 40 axes) C-663.12 (single SMC Hydra (double 663.12C885 (up to 20 axes) (motor) Sub-D 9 (m) (sensor) C-663.12 (single SMC Hydra (double 663.12C885 (up to 20 axes) Toleranc e Connecting cables for motor and sensor are not in the scope of delivery and must be ordered separately. Ask about custom designs!

Drawings and Images WT-85 goniometer stage, dimensions in mm

WT-85 goniometer stage, DC motor, dimensions in mm WT-85 goniometer stage, stepper motor, dimensions in mm Direction of the axes and torques for goniometer stages

Ordering Information 65409100 WT-85 goniometer stage, 85 mm width, DC motor, ±5 rotation range, clear aperture 30 mm diameter, mechanical limit switches 65409101 WT-85 goniometer stage, 85 mm width, DC motor, ±5 rotation range, angle with A/B quadrature signal transmission, clear aperture 30 mm diameter, mechanical limit switches 65409200-0000 WT-85 goniometer stage, 85 mm width, stepper motor, ±5 rotation range, clear aperture 30 mm diameter, mechanical limit switches 65409201-0001 WT-85 goniometer stage, 85 mm width, stepper motor, ±5 rotation range, angle with sin/cos signal transmission, clear aperture 30 mm diameter, mechanical limit switches For accessories, please specify when ordering 720090000 Connection cable for stages with stepper motor, 3 m 720190000 Connection cable for stages with DC motor, 3 m 721090000 Cable set for stages with, 3 m