PROVEN PLUS. Introducing the Avalus Aortic Valve by Medtronic.

Similar documents
PATIENT BOOKLET MEDTRONIC SURGICAL VALVE REPLACEMENT. Tissue Valve for Aortic and Mitral Valve Replacement

The St. Jude Medical Biocor Bioprosthesis

UNDERSTANDING YOUR HEART VALVE. Mosaic Tissue Valve

Cardioplegia Cannulae

CROWN PRT. Inservice implantation guide

Cardioblate CryoFlex Surgical Ablation System. Shaping Surgical Ablation.

TAV-IN-SAV SIZING GUIDE Evolut TAVR Transcatheter Aortic Valve in Degenerative Surgical Bioprosthesis

16 YEAR RESULTS Carpentier-Edwards PERIMOUNT Mitral Pericardial Bioprosthesis, Model 6900

MITROFLOW VALSALVA CONDUIT TM

COMMITTED FROM THE VERY START.

THE MEDTRONIC TRANSCATHETER AORTIC VALVE REPLACEMENT (TAVR) SYSTEM

Melody Transcatheter Pulmonary Valve and Ensemble Transcatheter Valve Delivery System GO TO INDEX COMMONLY BILLED CODES

COMPLEX CASES: LEFT MAIN

CoreValve in a Degenerative Surgical Valve

Trifecta Valve. Clinical Compendium. Five Year Data

2017 COMMONLY BILLED CODES

2018 COMMONLY BILLED CODES

TAVR for Valve-In-Valve. Brian O Neill Assistant Professor of Medicine Department of Medicine, Section of Cardiology

PATIENT BOOKLET MEDTRONIC MITRAL AND TRICUSPID HEART VALVE REPAIR

PATIENT BOOKLET. Medtronic Transcatheter Aortic Valve Replacement (TAVR) System. medtronic.com/tavr

MEMO 4D Reshaping Mitral Repair

Hemodynamics Benefit of Supra-Annular Design in Failed Bio-Prosthetic Valves

CLINICAL COMMUNIQUE 16 YEAR RESULTS

Resolute Integrity. Independent Conformability Assessment

What is TAVR? Transcatheter Aortic Valve Replacement

CAUTION- Investigational device. Limited by United States law to investigational use.

REF. Instructions for use Stented Porcine Tissue Valves Epic / Epic Supra INDICATIONS FOR USE CONTRAINDICATIONS DEVICE DESCRIPTION

ready to repair product brochure PERFORMANCE INNOVATION DESIGN mitral solutions

Medtronic Mosaic porcine bioprosthesis: Assessment of 12-year performance

Mitral Programme Update

Transcatheter Mitral Valve Replacement How Close Are We?

Outcome of Next-Generation Transcatheter Valves in Small Aortic Annuli: A Multicenter Propensity-Matched Comparison

Important Safety Information

Destination Therapy SO MUCH DATA IN SUCH A SMALL DEVICE. HeartWare HVAD System The ONLY intrapericardial VAD approved for DT.

Transcatheter aortic valve implantation for severe aortic valve stenosis with the ACURATE neo2 valve system: 30-day safety and performance outcomes

The stentless bioprosthesis has many salient features that

REDUCING THE IMPACT OF SURGERY AND FACILITATING FASTER RECOVERY

Echocardiographic Evaluation of Mitral Valve Prostheses

THE BLOOD PRESSURE PROCEDURE

Multicentre clinical study evaluating a novel resheatable self-expanding transcatheter aortic valve system

Incorporating the intermediate risk in Transcatheter Aortic Valve Implantation (TAVI)

PERFORMANCE YOU CAN TRUST. EverFlex Self-expanding Peripheral Stent with Entrust Delivery System

Transcatheter valve-in-valve implantation for degenerated surgical bioprostheses

LIFE IS DIFFERENT WITH PRO. Evolut PRO System

Tell the doctor who prescribed your MRI scan that you have an implanted Medtronic neurostimulation system.

MEMO 3D. The true reflection of the mitral annulus. Natural physiological 3D motion

Transcatheter Heart Valve. Replacement. With the Edwards SAPIEN 3. for Patients & Caregivers

TAVI- Is Stroke Risk the Achilles Heel of Percutaneous Aortic Valve Repair?

MEMO 3D RECHORD. Ready to repair. Guiding standards in Mitral valve repair

CoreValve Evolut R Technology review and Clinical Results. Paul TL Chiam

TAVR with the SAPIEN 3 Valve. See the Clinical Difference

Early Experience of Transcatheter Mitral Valve Replacement Results from the Intrepid Global Pilot Study

TAVI IN BICUSPID AOV AND VALVE-IN-VALVE

INSPIRIS RESILIA Aortic Valve

Transcatheter Aortic Valve Replacement

Outcomes of Mitral Valve Repair for Mitral Regurgitation Due to Degenerative Disease

Micra MC1VR01. MRI procedural information for Micra Model MC1VR01 MR Conditional single chamber transcatheter pacing device (VVIR)

Hani K. Najm MD, Msc, FRCSC FACC, FESC President Saudi Society for Cardiac Surgeons Associate Professor of Cardiothoracic Surgery King Abdulaziz

TAVI EN INSUFICIENCIA AORTICA

Neurostimulation Systems

QUICK REFERENCE HEARTWARE HVAD PUMP FLOW INDEX

Iatrogenic pathology of the heart:

Late failure of transcatheter heart valves: An open question

30-Day Outcomes Following Implantation of a Repositionable Self-Expanding Aortic Bioprosthesis: First Report From the FORWARD Study

Interventional procedures guidance Published: 26 September 2014 nice.org.uk/guidance/ipg504

3 rd TAVI Summit Seoul, August 9/10, 2013

CROWN PRT. The crowning touch. Experience designs performance

TAVI: Transapical Procedures

Treatment of Bio-Prosthetic Valve Deterioration Using Transcatheter Techniques

Experience with 500 Stentless Aortic Valve Replacements

15-Year Comparison of Supra-Annular Porcine and PERIMOUNT Aortic Bioprostheses

ThruPort Ergonic Minimal Incision Instrumentation

Stainless Steel. Cobalt-chromium

Indications and Late Results of Aortic Valve Repair

I will not discuss off label use or investigational use in my presentation.

Carpentier-Edwards supra-annular aortic porcine bioprosthesis: Clinical performance over 20 years

Valve Replacement without a Scalpel Transcatheter Aortic Valve Replacement (TAVR) Charles T. Klodell, M.D.

2017 Cardiovascular Symposium CARDIAC SURGERY UPDATE: SMALLER INCISIONS AND LESS COUMADIN DAVID L. SAINT, MD

TAVR or SAVR: Beyond the STS Score

Next Generation Therapies: Aortic, Mitral and Beyond

Transcatheter Aortic Valve Replacement

PROVEN. TRUSTED. COMMITTED. HeartWare HVAD System

TAVR Patient Screening & Identification Guide

LINQ THE RHYTHM TO THE SYMPTOM

Global Myocardial Protection

Percutaneous Valve Interventions. Percutaneous Valve Interventions

A UNIQUE APPROACH TO SACROILIAC JOINT FUSION PROCEDURES. Rialto PROCEDURE OVERVIEW. SI Fusion System

Portico (St. Jude Medical Inc, St.

In Vitro Two-Dimensional Echocardiographic Imaging of a Stented Porcine Bioprosthetic Valve: The Bent Strut Artifact

TSDA Boot Camp September 13-16, Introduction to Aortic Valve Surgery. George L. Hicks, Jr., MD

Aortic Stenosis and TAVR TARUN NAGRANI, MD INTERVENTIONAL AND ENDOVASCULAR CARDIOLOGIST, SOMC

Octopus Nuvo TISSUE STABILIZER. Take the next step with MICS CABG

T sors in the following aspects: the porcine aortic valve

Hani K. Najm MD, Msc, FRCSC, FRCS (Glasgow), FACC, FESC President of Saudi Heart Association King Abdulaziz Cardiac Centre Riyadh, Saudi Arabia.

New Cardiovascular Devices and Interventions: Non-Contrast MRI for TAVR Abhishek Chaturvedi Assistant Professor. Cardiothoracic Radiology

MITRAL (Mitral Implantation of TRAnscatheter valves)

CIPG Transcatheter Aortic Valve Replacement- When Is Less, More?

Integra. DigiFuse Cannulated Intramedullary Fusion System SURGICAL TECHNIQUE

PORTICO CE TRIAL ASSESSMENT OF THE ST. JUDE MEDICAL PORTICO TRANSCATHETER AORTIC VALVE IMPLANT AND THE TRANSFEMORAL DELIVERY SYSTEM

EVOLUT R FORWARD 30-DAY OUTCOMES PRESENTED AT THE TCT ANNUAL MEETING OCTOBER 31, 2016

Transcription:

PROVEN PLUS. Introducing the Avalus Aortic Valve by Medtronic. With more than 40 years of heart valve innovations, we took proven valve design concepts and adapted them for excellent implantability for you and performance for your patients. Avalus Bioprosthesis

YOU WANT THE VERY BEST FOR YOUR PATIENTS. SO DO WE. We designed the next generation bovine pericardial valve for better overall performance, improved implant experience, and a contemporary design to facilitate future valve-in-valve (ViV). O HO NH 2 Interior-mounted leaflets minimize damaging contact with the frame a design platform for long-term durability. AOA tissue treatment * to mitigate calcification over 20 years of clinical use on the Medtronic surgical tissue valve portfolio. 1,2 PROVEN Supra-annular design to enhance hemodynamics 3 Three laser cut bovine pericardial leaflets matched for thickness and deflection to provide consistent performance Two-part polymer frame minimizes stress zones on leaflets Sewing markers facilitate suture placement and valve orientation *No clinical data is available which evaluates the long-term impact of AOA treatment in patients.

PLUS Polyetheretherketone (PEEK) polymer stent provides strength and flexibility, and offers resistance to permanent deformation. Ease of Implant for You Soft and pliable sewing cuff facilitates needle penetration, suture placement, and valve seating for an improved implant experience Lower valve profile and narrow commissure posts expand ostia clearance and give you more space for knot tying Streamlined valve holder improves visibility in both standard and minimally invasive approaches Simple one-cut release

Designed to achieve 100% coaptation and minimize central regurgitation. Performance and Lifetime Management for Your Patients alve dimensions and V geometry enable future ViV replacements EEK base frame impregnated P with barium sulfate provides for radiopacity and visibility olymer frame mitigates the P risk of potential metal on metal corrosion with transcatheter stent materials RI Safe in all MR environments M without conditions Flexible support frame with firm base designed to maintain circularity and consistent hemodynamic performance.

Ordering and Specifications Avalus Valve Order Number Valve Size Stent Diameter (TAD) Internal Orifice Diameter * External Sewing Ring Diameter Valve Profile Height Aortic Protrusion (1) (2) (2a) (3) (4) (5) 40019 19 mm 19 mm 17.5 mm 18 mm 27.0 mm 13.0 mm 11.0 mm 40021 21 mm 21 mm 19.5 mm 20 mm 29.0 mm 14.0 mm 12.0 mm 40023 23 mm 23 mm 21.5 mm 22 mm 31.0 mm 15.0 mm 13.0 mm 40025 25 mm 25 mm 23.5 mm 24 mm 33.0 mm 16.0 mm 14.0 mm 40027 27 mm 27 mm 25.5 mm 26 mm 36.0 mm 17.0 mm 15.0 mm TAD Tissue Annulus Diameter * Measurement shows stent frame including tissue (2) and stent frame excluding tissue (2a). Accessories Order Number Description 7420 Valve Handle 7400S T7400 Avalus Sizers Tray, Accessory, Avalus References 1. Medtronic Freestyle Aortic Root Bioprosthesis was first implanted clinically in August 1992. Freestyle Aortic Root Bioprosthesis 15-Year Clinical Compendium. 2016 Medtronic. 2. Jamieson WR, Riess FC, Raudkivi PJ, et al. Medtronic Mosaic porcine bioprosthesis: assessment of 12-year performance. J Thorac Cardiovasc Surg. August 2011;142(2):302-7. 3. Ruzicka DJ, Hettich I, Hutter A, et al. The complete supraannular concept. Circulation 2009;120[suppl 1]:S139-S145. 1 2 3 5 4 Avalus Bioprosthesis Indications: The Avalus bioprosthesis is indicated for the replacement of diseased, damaged, or malfunctioning native or prosthetic aortic valves. Contraindications: None known. Warnings/Precautions/ Adverse Events: Only physicians who have received proper training in valve replacement should use this device. Accelerated structural deterioration due to calcific degeneration of bioprosthesis may occur in: children, adolescents, young adults, and patients with altered calcium metabolism (e.g., chronic renal failure, or hyperparathyroidism). Adverse events can include: angina, cardiac dysrhythmias, endocarditis, heart failure, hemolysis, hemolytic anemia, hemorrhage, infection other than endocarditis, transvalvular or paravalvular leak, myocardial infarction, nonstructural valve dysfunction (leaflet entrapment/impingement, obstructive pannus ingrowth, suture dehiscence, inappropriate sizing or positioning, or other), pericardial effusion or tamponade, prosthesis regurgitation, prosthesis stenosis, prosthesis thrombosis, stroke, structural valve deterioration (calcification, leaflet tear or perforation, or other), thromboembolism, tissue dehiscence, and transient ischemic attack. These complications could lead to reoperation, explant of the bioprosthesis, permanent disability, or death. Caution: Federal law (USA) restricts this device to sale by or on the order of a physician. For a listing of indications, contraindications, precautions, warnings, and potential adverse events, please refer to the Instructions for Use. For countries that use eifus, consult instructions for use at www.medtronic.com/manuals. Note: Manuals can be viewed using a current version of any major internet browser. 710 Medtronic Parkway Minneapolis, MN 55432-5604 USA Tel: (763) 514-4000 Fax: (763) 514-4879 Toll-free: (800) 328-2518 LifeLine CardioVascular Technical Support Tel: (877) 526-7890 Tel: (763) 526-7890 Fax: (763) 526-7888 rs.cstechsupport@medtronic.com Europe Medtronic International Trading Sàrl Route du Molliau 31 Case Postale CH-1131 Tolochenaz Switzerland Tel: (41 21) 802-7000 Canada Medtronic of Canada Ltd. 99 Hereford Street Brampton, Ontario L6Y 0R3 Canada Tel: (905) 460-3800 Toll-free: (800) 268-5346 Asia Medtronic International Ltd. 49 Changi South Avenue 2 Nasaco Tech Centre Singapore 486056 Singapore Tel: (65) 6436-5000 Latin America Doral Corporate Centre II 3750 NW 87th Avenue, Suite 700 Miami, FL 33178 USA Tel: (305) 500-9328 2018 Medtronic. All rights reserved. Medtronic, Medtronic logo and Further, Together are trademarks of Medtronic. All other brands are trademarks of a Medtronic company. UC201608716b EN 04/2018 medtronic.com