Vaginal Sparing with Volumetric Modulated Arc Therapy (VMAT) for Rectal Cancer. Scott Boulet BSc, RT(T)

Similar documents
Dosimetric Analysis of 3DCRT or IMRT with Vaginal-cuff Brachytherapy (VCB) for Gynaecological Cancer

IMRT - the physician s eye-view. Cinzia Iotti Department of Radiation Oncology S.Maria Nuova Hospital Reggio Emilia

A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer

A treatment planning study comparing Elekta VMAT and fixed field IMRT using the varian treatment planning system eclipse

La Pianificazione e I Volumi di Trattamento

Role of Belly Board Device in the Age of Intensity Modulated Radiotherapy for Pelvic Irradiation

Radiation Therapy: From Fallacy to Science

Treatment Planning & IGRT Credentialing for NRG SBRT Trials

A Dosimetric Comparison of Whole-Lung Treatment Techniques. in the Pediatric Population

A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM *

Outline. Contour quality control. Dosimetric impact of contouring errors and variability in Intensity Modulated Radiation Therapy (IMRT)

Implementation of Gynaecological IMRT Planning Technique Clinical Guidelines and Constraints. Chloe Pandeli

Feasibility of the partial-single arc technique in RapidArc planning for prostate cancer treatment

The Evolution of RT Techniques for Gynaecological Cancers in a developing country context

Treatment Planning for Lung. Kristi Hendrickson, PhD, DABR University of Washington Dept. of Radiation Oncology

NEWER RADIATION (3 D -CRT, IMRT, IGRT) TECHNIQUES FOR CERVICAL CANCERS (COMMON PELVIC TUMORS)

Defining Target Volumes and Organs at Risk: a common language

Original Article. Teyyiba Kanwal, Muhammad Khalid, Syed Ijaz Hussain Shah, Khawar Nadeem

SBRT TREATMENT PLANNING: TIPS + TRICKS. Rachel A. Hackett CMD, RT(T)

Kenny Guida, DMP, DABR March 21 st, 2015

Evaluation of the Dynamic Arc-Therapy in Comparison to Conformal Radiation Therapy in Radiotherapy Patients

THE TRANSITION FROM 2D TO 3D AND TO IMRT - RATIONALE AND CRITICAL ELEMENTS

ART for Cervical Cancer: Dosimetry and Technical Aspects

Recent Advances and current status of radiotherapy for cervix cancer

IMRT Planning Basics AAMD Student Webinar

Department of Radiotherapy & Nuclear Medicine, National Cancer Institute, Cairo University, Cairo, Egypt.

The New ICRU/GEC ESTRO Report in Clinical Practice. Disclosures

IMAT: intensity-modulated arc therapy

Head and Neck Treatment Planning: A Comparative Review of Static Field IMRT RapidArc TomoTherapy HD. Barbara Agrimson, BS RT(T)(R), CMD

Evaluation of Three-dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy Techniques in High-Grade Gliomas

IGRT Solution for the Living Patient and the Dynamic Treatment Problem

PRINCESS MARGARET CANCER CENTRE CLINICAL PRACTICE GUIDELINES GYNECOLOGIC CANCER CERVIX

BLADDER RADIOTHERAPY PLANNING DOCUMENT

A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM *

Intensity modulated radiotherapy (IMRT) for treatment of post-operative high grade glioma in the right parietal region of brain

3D ANATOMY-BASED PLANNING OPTIMIZATION FOR HDR BRACHYTHERAPY OF CERVIX CANCER

Jean Pouliot, PhD Professor and Vice Chair, Department of Radiation Oncology, Director of Physics Division

Comparison of high and low energy treatment plans by evaluating the dose on the surrounding normal structures in conventional radiotherapy

The Physics of Oesophageal Cancer Radiotherapy

Savita Dandapani, MD, PhD City of Hope Duarte, CA

New Technologies for the Radiotherapy of Prostate Cancer

Introduction of RapidArc TM : an example of commissioning and implementing a QA programme for a new technology

Clinical experience with TomoDirect System Tangential Mode

Stereotactic ablative body radiation for prostate cancer SABR

Course Directors: Teaching Staff: Guest Lecturers: Local Organiser: ESTRO coordinator: Melissa Vanderijst, project manager (BE)

Editorial Process: Submission:11/14/2017 Acceptance:07/31/2018

Statistical Analysis and Volumetric Dose for Organ at Risk of Prostate Cancer

The objective of this lecture is to integrate our knowledge of the differences between 2D and 3D planning and apply the same to various clinical

International Multispecialty Journal of Health (IMJH) ISSN: [ ] [Vol-3, Issue-9, September- 2017]

Sanja Ognjenovic A PROJECT. submitted to. Oregon State University. University Honors College

Helical Tomotherapy Experience. TomoTherapy Whole Brain Head & Neck Prostate Lung Summary. HI-ART TomoTherapy System. HI-ART TomoTherapy System

International Journal of Health Sciences and Research ISSN:

GYNECOLOGIC CANCER and RADIATION THERAPY. Jon Anders M.D. Radiation Oncology

Chapters from Clinical Oncology

Reena Phurailatpam. Intensity Modulated Radiation Therapy of Medulloblastoma using Helical TomoTherapy: Initial Experience from planning to delivery

REVISITING ICRU VOLUME DEFINITIONS. Eduardo Rosenblatt Vienna, Austria

Evaluation of Whole-Field and Split-Field Intensity Modulation Radiation Therapy (IMRT) Techniques in Head and Neck Cancer

Knowledge-Based IMRT Treatment Planning for Prostate Cancer: Experience with 101. Cases from Duke Clinic. Deon Martina Dick

The role of Radiation Oncologist: Hi-tech treatments for liver metastases

Automated Plan Quality Check with Scripting. Rajesh Gutti, Ph.D. Clinical Medical Physicist

3D-CRT Breast Cancer Planning

Advances in external beam radiotherapy

Prostate and Lymph Node VMAT Treatment Planning

Corporate Medical Policy

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 17, NUMBER 6, 2016

Stereotactic MR-guided adaptive radiation therapy (SMART) for locally advanced pancreatic tumors

Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases

The sigmoid colon and bladder shielding in whole pelvic irradiation at prostate cancer (forward planned IMRT from Institute of Oncology Ljubljana)

Mesothelioma XRT: From Old School to New School. A brief walk down memory lane at UCLA

VMAT planning study in rectal cancer patients

Dosimetric Comparison of Intensity-Modulated Radiotherapy versus 3D Conformal Radiotherapy in Patients with Head and Neck Cancer

A Thesis. entitled. based on CBCT Data Dose Calculation. Sukhdeep Kaur Gill. Master of Science Degree in Biomedical Science

Efficient SIB-IMRT planning of head & neck patients with Pinnacle 3 -DMPO

3D Pre-treatment Dose Verification for Stereotactic Body Radiation Therapy Patients

Treatment Planning for Breast Cancer: Contouring Targets. Julia White MD Professor

Role of IMRT in the Treatment of Gynecologic Malignancies. John C. Roeske, PhD Associate Professor The University of Chicago

Rectal dose and toxicity dosimetric evaluation for various beam arrangements using pencil beam scanning protons with and without rectal spacers

Application of asi-kvcbct for Volume Assessment and Dose Estimation: An Offline Adaptive Study for Prostate Radiotherapy

Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI)

Implementation of advanced RT Techniques

ENDPOINTS IN ONCOLOGY- HOW LONG WILL A CANCER PATIENT SURVIVE? DR GUNJAN BAIJAL CONSULTANT RADIATION ONCOLOGY MANIPAL GOA

IMRT - Intensity Modulated Radiotherapy

Elekta - a partner and world-leading supplier

Locally advanced disease & challenges in management

Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR

Department of Radiation Oncology, İstanbul University Cerrahpaşa Faculty of Medicine, İstanbul-Türkiye ), D 5%

Dose escalation for NSCLC using conformal RT: 3D and IMRT. Hasan Murshed

TRANS-TASMAN RADIATION ONCOLOGY GROUP INC. Quality Assurance. Treatment Planning Benchmark

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

Andrew K. Lee, MD, MPH Associate Professor Department tof fradiation Oncology M.D. Anderson Cancer Center

CBCT of the patient in the treatment position has gained wider applications for setup verification during radiotherapy.

Linac Based SBRT for Low-intermediate Risk Prostate Cancer in 5 Fractions: Preliminary Report of a Phase II Study with FFF Delivery

Guidelines for the use of inversely planned treatment techniques in Clinical Trials: IMRT, VMAT, TomoTherapy

8/1/2017. Clinical Indications and Applications of Realtime MRI-Guided Radiotherapy

Innovazioni tecnologiche in Radioterapia" Sergio Fersino Radioterapia Oncologica

Intensity-Modulated and Image- Guided Radiation Treatment. Outline. Conformal Radiation Treatment

Radiotherapy Advances

Evaluation of Normal Tissue Complication Probability and Risk of Second Primary Cancer in Prostate Radiotherapy

The Effects of DIBH on Liver Dose during Right-Breast Treatments: A Case Study Abstract: Introduction: Case Description: Conclusion: Introduction

Feasibility of 4D IMRT Delivery for Hypofractionated High Dose Partial Prostate Treatments

Transcription:

Vaginal Sparing with Volumetric Modulated Arc Therapy (VMAT) for Rectal Cancer Scott Boulet BSc, RT(T)

Outline Background Objectives Design Results Discussion Conclusion Acknowledgements Questions

Background RT for Rectal Cancer Anatomical considerations and challenges Vaginal side effects following RT Sexual Dysfunction: treatment and management Vaginal sparing: What is being done? Previous studies

Rectum Anatomy Lu, J., & Brady, Luther W. (2010). Decision Making in Radiation Oncology (Medical Radiology Radiation Oncology). Dordrecht: Springer.

Rectal Cancer Lu, J., & Brady, Luther W. (2010). Decision Making in Radiation Oncology (Medical Radiology Radiation Oncology). Dordrecht: Springer.

Rectal Cancer 3D Conformal RT Lu, J., & Brady, Luther W. (2010). Decision Making in Radiation Oncology (Medical Radiology Radiation Oncology). Dordrecht: Springer.

Rectal Cancer IMRT Improved target coverage, homogeneity, and conformality, while lowering dose to adjacent organs-at-risk. The use of preoperative IMRT IGRT with a SIB resulted in a high 5- year LC rate and non-negligible late toxicity

VMAT MLCs moving continuously as gantry rotates Delivering a sculpted, tightly-focused beam of radiation directly to a tumor in less than two minutes. Varian Medical Systems

Female Pelvic Anatomy Morton, D., Albertine, Kurt H., & Foreman, K. Bo. (2011). The big picture gross anatomy (McGraw-Hill's AccessMedicine). New York, N.Y.: McGraw Hill Medical.

Vaginal Side Effects Sexual Dysfunction Dyspareunia Dryness Stenosis

Management Techniques Dilators Pelvic Floor Muscle training Lubricants Moisturizers Estrogen

Vaginal Dilators includes the use of dilators, sexual intercourse, vibrators, fingers, or similar shaped devices commenced 2-8 weeks post radiotherapy, Risk of rectovaginal fistulae and psychological consequences Non-consistent education and compliance

Vaginal sparing: what is being done? NOTHING! Why? Doesn't effect all people with rectal cancer Older women are less interested in sex Vagina is difficult to contour Not previously possible with 3DCRT Lack of literature Uncomfortable subject to talk about.

Vaginal sparing: what is being done? As vaginal mean dose increases, vaginal stenosis increases. Severe vaginal stenosis is significantly reduced at mean doses <43Gy

Study Objectives To investigate whether VMAT treatment plans with, and without, vaginal sparing could significantly reduce the volume of the vagina that receives 20Gy (V20Gy), 30, 40, 45, or 50Gy when targeting rectal cancer tumours. Determine whether the maximum dose delivered, and the mean dose delivered are significantly different between the two treatment plans.

Methods Sample Size = 10 patients (Retrospective) Inclusion: 1) Diagnosed locally advanced rectal cancer 2) Stage T3, N1-2, MX/MO (Lower 1/3) 3) Recent pre-op MRI available for delineating the vagina 4) pre-operative 3DCRT At CancerCare Manitoba 5) 45G/25 FXs to the primary disease and lymph nodes, Boost 5.4Gy/3 FXs 6) simulated supine with full bladder and knee rest.

Contouring Vagina contoured by single physician Pre-op MRI used for delineating vagina Target volumes and OARs contoured as per RTOG Anorectal Atlas

Contouring

Contouring

VMAT Two 360 coplanar arcs 6 MV Eclipse V11 planning software(varian Medical Systems) Rapid Arc (VMAT) 2 phases 45GY/25 FXs, 5.4Gy/3FXs

Optimization Target coverage: D100% = 95% Rx, Dmax <107% OARs: Bladder, small bowel, femoral heads 2VMAT Plans 1) VMAT plan (normal) Goals: Target coverage, OARs ALARA 2) VMAT with vagina objective Goals: decrease vagina dose without compromising target coverage and OAR sparing.

Results Formal comparisons between the two treatment plans were carried using Wilcoxon signed-rank testing All data were available for analysis except the V20 and V30Gy volumes due to a lack of variability. Significant differences, even with the Bonferroni correction, were observed for the mean and maximum doses delivered, as well as for the V50Gy volumes. The V45Gy volumes also appeared different between the two treatment plans (Table 2) and would normally be considered significant at the P-value 0.05 threshold, but because the threshold P-value was adjusted using the Bonferroni correction, it was no longer significant.

Results 120 Median Dose Comparison 100 80 60 VMAT VMAT with Vaginal Objective 40 20 0 Max Mean 50Gy 45Gy 40Gy 30Gy 20Gy

Table 1: Descriptive statistics of mean and maximum doses delivered by each of the VMAT treatment plans. Results Variable Median IQR 90 th percentile Minimum Maximum VMAT Mean Dose (cgy) 4990.90 71.60 5044.80 4779.20 5048.90 Maximum Dose (cgy) 5255.85 44.40 5314.60 5150.50 5319.40 VMAT with vaginal sparing Mean Dose (cgy) 4779.50 130.4 4876.00 4654.20 4880.20 Maximum Dose (cgy) 4962.80 65.20 5022.35 4922.3 5025.20

Table 2: Frequency and percent of volumes of the vagina exposed to 20, 30 40, 45 or 50Gy by each of the two VMAT treatment plans. Results VMAT VMAT with vaginal sparing Values Frequency Percent Values Frequency Percent V20Gy V20Gy 100.00 10 100.00 100.00 10 100.00 V30Gy 100.00 10 100.00 100.00 10 100.00 V30Gy V40Gy V40Gy 99.20 1 10.00 96.90 1 10.00 100.00 9 90.00 99.10 1 10.00 100.00 8 80.00 V45Gy 93.30 1 10.00 V45Gy 95.30 1 10.00 61.50 1 10.00 98.20 1 10.00 74.90 1 10.00 99.80 1 10.00 97.20 1 10.00 100.00 6 60.00 98.20 1 10.00 99.30 1 10.00 V50Gy 99.80 1 10.00 14.00 1 10.00 100.00 4 40.00 36.60 1 10.00 37.30 1 10.00 V50Gy 43.30 1 10.00 0.00 7 70.00 46.90 1 10.00 0.01 1 10.00 48.20 1 10.00 0.03 1 10.00 60.10 1 10.00 0.10 1 10.00 64.50 1 10.00 67.40 1 10.00 68.60 1 10.00

Results 100 Volume recieving radiation dose (%) 80 60 40 20 0 VMAT V45Gy VMAT V50Gy Sparing VMAT V45Gy Sparing VMAT V50Gy

DVH Comparison

Phase 1: 45 Gy

Plan Sum: 50.4 Gy/28Fx

Discussion Significance of decreasing the V50Gy, mean and maximum doses Contouring Vaginal Motion Use of a dilator during RT IGRTs role in vaginal sparing Concerns

reducing the V50Gy, mean, and maximum dose Does Vaginal Sparing translate to decreased toxicity?

Vaginal Motion

Vagina Contouring Image registration issues Need to generate consistent guidelines

Dilator during RT

IGRT IGRT improvements Smaller margins Less vagina in field Daily vagina assessment Adaptive radiotherapy Bladder filling

Concerns Potential risk of marginal relapse

Conclusion VMAT planning using an objective to spare the vagina can significantly reduce the volume of vagina receiving 50Gy, as well as the Dmax and Dmean, without compromising target coverage or adjacent organs at risk dose constraints.

Acknowledgment Bashir Bashir MD Oliver Bucher Eric VanUytven Junaid Khan John Ioculano

Thank you!