EEG Source Imaging in Epilepsy Evaluations

Similar documents
Est-ce que l'eeg a toujours sa place en 2019?

EEG source Localization (ESL): What do we know now?

Depth/surface relationships: Confronting noninvasive measures to intracerebral EEG

Depth/Surface Relationships: Confronting noninvasive measures to intracerebral EEG

Toward a more accurate delimitation of the epileptic focus from a surgical perspective

(Electric) Source Analysis Kanjana Unnwongse, MD

Benefit of Simultaneous Recording of EEG and MEG in Dipole Localization

EEG & MEG Source Imaging in Epilepsy: Which is Better?

Connectivity in epilepsy: Characterization of pathological networks on EEG, MEG and intracerebral EEG

Practical class neuromodulation and imaging: EEG source analysis. Pieter van Mierlo Willeke Staljanssens Gregor Strobbe

Temporal and spatial determination of EEG-seizure onset in the frequency domain

This presentation is the intellectual property of the author. Contact them for permission to reprint and/or distribute.

Seizure onset can be difficult to asses in scalp EEG. However, some tools can be used to increase the seizure onset activity over the EEG background:

EEG source localization of the epileptogenic focus in patients with refractory temporal lobe epilepsy, dipole modelling revisited

Spike voltage topography in temporal lobe epilepsy

EMG, EEG, and Neurophysiology in Clinical Practice

King s Research Portal

Analysis of the dynamics and origin of epileptic activity in patients with tuberous sclerosis evaluated for surgery of epilepsy

Electrical source imaging of interictal spikes using multiple sparse volumetric priors for presurgical epileptogenic focus...

Diagnosing Complicated Epilepsy: Mapping of the Epileptic Circuitry. Michael R. Sperling, M.D. Thomas Jefferson University Philadelphia, PA

EPILEPSY SURGERY EVALUATION IN ADULTS WITH SCALP VIDEO-EEG MONITORING. Meriem Bensalem-Owen, MD University of Kentucky

EEG-Correlated Functional MRI: Recent Methodologic Progress and Current Issues

Verification of dipole fit source localization in patients with epilepsy using postoperative MRI

BESA Research Quick Guide

Clinical Study Integrating Dense Array EEG in the Presurgical Evaluation of Temporal Lobe Epilepsy

Source Imaging in Mapping Eloquent Cortex December 6 th 2011

Intracranial EEG Substrates of Scalp EEG Interictal Spikes

EEG Wave of the Future: The Video-EEG and fmri Suite?

Evaluation of EEG localization methods using realistic simulations of interictal spikes:

The Changing Surgical Landscape in Kids

Is the Hemodynamic Response to Scalp Interictal Epileptic Discharges the Onset Zone of Intracerebral Interictal Discharges?

PRESURGICAL EVALUATION. ISLAND OF COS Hippocrates: On the Sacred Disease. Disclosure Research-Educational Grants. Patients with seizure disorders

EEG source localization in focal epilepsy: Where are we now?

Intracranial Studies Of Human Epilepsy In A Surgical Setting

PET and SPECT in Epilepsy

Subject: Magnetoencephalography/Magnetic Source Imaging

High Resolution Ictal SPECT: Enhanced Epileptic Source Targeting?

Research Article Effect of Brain-to-Skull Conductivity Ratio on EEG Source Localization Accuracy

Database of paroxysmal iceeg signals

Dipole Localization for Identification of Neuronal Generators in Independent Neighboring Interictal EEG Spike Foci

Scalp EEG Findings in Temporal Lobe Epilepsy

ESI and fmri of interictal and ictal epileptic discharges

Focal epilepsy recruiting a generalised network of juvenile myoclonic epilepsy: a case report

Accepted Manuscript. Editorial. Responsive neurostimulation for epilepsy: more than stimulation. Jayant N. Acharya

Common Ictal Patterns in Patients with Documented Epileptic Seizures

Spatial localisation of EEG dipoles in MRI using the International System anatomical references

5/22/2009. Pediatric Neurosurgery Pediatric Neurology Neuroradiology Neurophysiology Neuropathology Neuropsychology

Spatial and Temporal Analysis of Interictal Activity in the Epileptic Brain

Interictal High Frequency Oscillations as Neurophysiologic Biomarkers of Epileptogenicity

The American Approach to Depth Electrode Insertion December 4, 2012

Multimodal Imaging in Extratemporal Epilepsy Surgery

Advanced Imaging Techniques MRI, PET, SPECT, ESI-MSI, DTI December 8, 2013

ACCEPTED MANUSCRIPT. Ictal EEG Source Imaging for Presurgical Evaluation of Refractory Focal Epilepsy

Surgical Management of Post- Traumatic Epilepsy Complexities-Adhesions and Multifocality

Case report. Epileptic Disord 2005; 7 (1): 37-41

Imaging in epilepsy: Ictal perfusion SPECT and SISCOM

A reappraisal of secondary bilateral synchrony

The power of Tensor algebra in medical diagnosis

Challenges for multivariate and multimodality analyses in "real life" projects: Epilepsy

A Review of Electrical Source Imaging

Frequency domain EEG source localization of ictal epileptiform activity in patients with partial complex epilepsy of temporal lobe origin

Surgery in temporal lobe epilepsy patients without cranial MRI lateralization

Neocortical Temporal Lobe Epilepsy

Source Analysis of Interictal Spikes in EEG and MEG

Spike frequency is dependent on epilepsy duration and seizure frequency in temporal lobe epilepsy

Difficult-to-Localize Intractable Focal Epilepsy: An In-Depth Look

What the Referring Physician Needs to Know About Magnetoencephalography (MEG)

PARAFAC: a powerful tool in EEG monitoring

Epilepsy Surgery: A Pediatric Neurologist s Perspective

Epileptic seizure detection using linear prediction filter

From Spikes to Ripples: The Evolving and Expanding Role of Electroencephalography in the Diagnosis and Treatment of Epilepsy

Imaging and EEG in Post-traumatic Epilepsy

EPILEPSY. New Ideas about an Old Disease. Gregory D. Cascino, MD

Epilepsy Surgery, Imaging, and Intraoperative Neuromonitoring: Surgical Perspective

Latero-Orbital and Anterior-Temporal Electrodes "Their Usefulness in Diagnosing Complex Partial Seizures"

ChosingPhase 2 Electrodes

Localization of Temporal Lobe Foci by Ictal EEG Patterns

High-resolution EEG: Cortical potential imaging of interictal spikes

Analysis of Seizure Onset on the Basis of Wideband EEG Recordings

Non-lesional Medically-intractable Localization-related Epilepsy Case Presentation December 8, 2013

Electroencephalography. Role of EEG in NCSE. Continuous EEG in ICU 25/05/59. EEG pattern in status epilepticus

Analysis of the generators of epileptic activity in early-onset childhood benign occipital lobe epilepsy

Clinical Policy: Digital EEG Spike Analysis

Epilepsy 101. Overview of Treatment Georgette Smith, PhD, APRN, CPNP. American Epilepsy Society

Transient Attenuation of Visual Evoked Potentials during Focal Status Epilepticus in a Patient with Occipital Lobe Epilepsy

Epilepsy & Behavior Case Reports

Invasive Evaluation for Epilepsy Surgery Lesional Cases NO DISCLOSURES. Mr. Johnson. Seizures at 29 Years of Age. Dileep Nair, MD Juan Bulacio, MD

Ictal near infrared spectroscopy in temporal lobe epilepsy: a pilot study

9/30/2016. Advances in Epilepsy Surgery. Epidemiology. Epidemiology

Combined EEG/MEG Can Outperform Single Modality EEG or MEG Source Reconstruction in Presurgical Epilepsy Diagnosis

One key to achieving a successful outcome of epilepsy surgery

EEG workshop. Epileptiform abnormalities. Definitions. Dr. Suthida Yenjun

Acute Management of Seizures

EEG Source Localization of Interictal and Ictal Spikes Acquired During Video-EEG Monitoring

Early seizure propagation from the occipital lobe to medial temporal structures and its surgical implication

Review Article Electroencephalography in Mesial Temporal Lobe Epilepsy: A Review

Interview. News & Views. The importance of surgery for epilepsy. Jerome Engel Jr

Seizure Detection with a Commercially Available Bedside EEG Monitor and the Subhairline Montage

Clinical Policy Title: Magnetoencephalography and magnetic source imaging

Successful Treatment of Mesial Temporal Lobe Epilepsy with Bilateral Hippocampal Atrophy and False Temporal Scalp Ictal Onset: A case report

Transcription:

EEG Source Imaging in Epilepsy Evaluations December 6, 2011 Thomas Bast, MD Head of the Department of Children and Adolescents Epilepsy Centre Kork Germany American Epilepsy Society Annual Meeting

Disclosure No conflict of interest American Epilepsy Society Annual Meeting

Learning Objectives Realize that EEG as a basic and unique method in epilepsy evaluation provides more information when methods of source imaging are applied Understand how simultaneous EEG adds information to MEG American Epilepsy Society Annual Meeting 3

What are the goals of EEG source analysis? Every EEG reviewer builds a hypothesis on the localization of the underlying cortical generator of interictal and/or ictal epileptic activity Quality of this hypothesis depends on experience Source analysis leads to more stable hypotheses and allows for better visualization by MRI coregistration 12 y, m, refractory epilepsy with tonic/hypermotor seizures 4

EEG source analysis: different models Raw data Averaged spikes (n=36) Discrete source model (regional source) L2 minimum norm Bilateral beamformer 10-45 Hz LAURA 5

Success of EEG source localization depends on Head model Realistic >> spherical Finite element method > boundary element method Individual > standard FEM model Wolters et al., Neuroimage 2006 Chen et al., Med Phys 2010 Hallez et al., Phys Med Biol 2009 Michel et al., Clin Neurophysiol 2004 Scheler et al., Hum Brain Map 2007 Wolters et al., Neuroimage 2006 6

Success of EEG source localization depends on Head model Number of electrodes Brodbeck et al., Brain 2011 Lantz et al., Clin Neurophysiol 2003 Michel et al., Clin Neurophysiol 2004 Wang et al., Clin Neurophysiol 2011 Dense-array EEG = 128-256 electrodes Holmes et al., Ped Neurosurg 2008 63 vs. 128 channels no relevant difference for most cases Lantz et al., Clin Neurophysiol 2003 7

Success of EEG source localization depends on Head model Number of electrodes Important: Inclusion of subtemporal positions Ebersole, J Clin Neurophysiol 1997 Ebersole & Wade, Neurology 1991 Kobayashi et al., Clin Neurophysiol 2000 Sperli et al., Epilepsia 2006 Hamaneh et al., J Clin Neurophysiol 2011 8

Success of EEG source localization depends on Head model Number of electrodes Analysis of spike onset instead of (potentially propagated) peak activity Averaging of similar spikes Bast et al., Neuroimage 2005 Bast et al., J Clin Neurophysiol 2006 Huppertz et al., Neuroimage 2001 Michel et al., Clin Neurophysiol 2004 Ramantani et al., J Clin Neurophysiol 2006 Zumsteg et al., Clin Neurophysiol 2005 9

EEG source analysis: onset propagation -40 ms RH? LORETA Peak LORETA 156 averages, 5 45 Hz 10

EEG dipole localization depends on SNR Bast et al., J Clin Neurophysiol 2006 11

EEG source analysis in presurgical epilepsy evaluation Comparison with invasive recordings Assaf & Ebersole, Epilepsia 1997 Holmes et al., Neurosurgery 2010 Merlet & Gotman, Clin Neurophysiol 2001 Ray et al., Clin Neurophysiol 2006 Zumsteg et al., Clin Neurophysiol 2005 Epilepsy surgery Correct localization on lobar level > 90% Michel et al., Clin Neurophysiol 2004 Sperli et al., Epilepsia 2006 12

Follow-up > 1 year Outcome Engel 1/2 77% Long-term EEG in all (19-29 electrodes) 55 additional dense array (128-256 electrodes) Interictal LAURA (routine dense array) + realistic head model (standard individual) Sensitivity (localization within resection zone and seizure free) Individual head model and 128-256 electrodes 84.1 Standard head model and 19-29 electrodes 59.1 Specificity (localization outside resection zone and not seizure free) Individual head model and 128-256 electrodes 87.5 Standard head model and 19-29 electrodes 62.5 Sensitivity > Structural MRI/PET/ictal SPECT 13

Ictal EEG Methods of interictal EEG source analysis ictal patterns Cave Artifacts Modeling of earliest rhythmic pattern Assaf & Ebersole, 1997 Assaf & Ebersole, 1999 Boon et al., Epilepsia 1996 Boon et al., J Clin Neurophysiol 2002 Holmes et al., Ped Neurosurgery 2008 Holmes et al., Neurosurgery 2010 Stern et al., J Clin Neurophysiol 2009 14

Impact of ictal EEG source analysis on decision making in presurgical epilepsy work-up Prospective study 100 patients 83 lesional 53 with unilateral mtle 27 channel EEG Ictal recordings in 93 31 analyzable without artifacts New and relevant information in 14 cases Boon et al., J Clin Neurophysiol 2002 15

Fixed source montages are feasible and allow for quick overview Left temporobasal spike (91 avr) Dipole and CLARA Onset -12 ms See also: Assaf & Ebersole, Epilepsia 1997 16

Fixed source montages are feasible and allow for quick overview See also: Assaf & Ebersole, Epilepsia 1997 17

Why MEG should be combined with EEG Is EEG old fashioned? MEG Better, bigger, higher Castle and old bridge, Heidelberg 18

Why MEG should be combined with EEG EEG onset P r o p a g a t I o n MEG onset Bast et al., Neuroimage 2005 19

Why MEG should be combined with EEG maximum signal minimum signal no signal 20

Why MEG should be combined with EEG Simulation 1/3 1/3 Bast et al., Neuroimage 2005 21

Impact on Clinical Care and Practice EEG source imaging adds information that has impact on decision making in presurgical work-up. It has a sensitivity of up to 84% (specificity 87.5%) compared to resection zone in seizure free patients. Use more than 10-20 electrodes! The more the better (at least 32 channels, better 128) Include subtemporal locations! Apply realistic head models! If you have access to MEG Don t forget to record EEG simultaneously! Use adequate methods for both when comparing EEG with MEG! 22

Kork Epilepsy Centre tbast@epilepsiezentrum.de 23