US EPA SW-846 Method 6010D using the Thermo Scientific icap 7400 ICP-OES Duo

Similar documents
Analysis of trace elements in nutraceuticals in compliance with USP chapter <2232> Elemental Contaminants in Dietary Supplements

Determination of Copper in Green Olives using ICP-OES

Matrix Interferences in ICP-MS: Causes, Effects, and Strategies to Reduce or Eliminate Them

Determination of metals in industrial wastewaters by microwave plasmaatomic emission spectrometry

Analysis of Micronutrients in Milk by Flame Atomic Absorption Using FAST Flame Sample Automation for Increased Sample Throughput

Application note. Determination of metals in soil by microwave plasma - atomic emission spectrometry (MP-AES) using DTPA extraction.

Evaluating the performance of the OneNeb Series 2 Nebulizer with PerkinElmer Optima 7/8x00 Series ICP-OES systems

Determination of available nutrients in soil using the Agilent 4200 MP-AES

Performance Characteristics of the Agilent High Matrix Sample Introduction (HMI) Accessory for the 7500 Series ICP-MS. Product Overview.

SECTIOn 3. Multi-Element ClP Standards for ICP & ICP-MS

Trace Metal Characterization of Soils Using the Optima 7300 DV ICP-OES

Analysis of Milk for Major and Trace Elements by ICP-MS

Routine Analysis of Fortified Foods using the Agilent 7800 ICP-MS

Analysis of Blood Serum on the Liberty Series II ICP OES with the Axially- Viewed Plasma

Analysis of Blood Serum on the Liberty Series II ICP OES with the Axially-Viewed Plasma

GLASS EXPANSION NEWSLETTER

Bottom Ash Data Week 37

Mike Hinds, Royal Canadian Mint

Bottom Ash Data Week 30

AVIO 200 ICP-OES CONSUMABLES AND SUPPLIES. Consumables and Supplies Reference Guide

Bottom Ash Data Week 38

Matrix Reference Materials - SCP SCIENCE

Low-Pressure Chromium Speciation in P2O5 using the Spectro ARCOS MV ICP and the ESI SC-DX chromfast System

MULTI-COMPONENT ANALYSIS OF HEAVY METALS

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages

Bottom Ash Data Week 9

Bottom Ash Data Week 17

Bottom Ash Data Week 49

Analysis of Organic Fertilizers for Nutrients with AAnalyst 800 Atomic Absorption Spectrophotometer

Understanding New USP Chapter <2232> for Trace Elemental Contaminants in Dietary Supplements and Nutraceutical Products

The Investigation of Factors Contributing to Immunosuppressant Drugs Response Variability in LC-MS/MS Analysis

Food safety is an area of growing concern as a result of pollution,

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

Multi Analyte Custom Grade Solution

Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column

Technology offer: High efficiency sample introduction nebulizer

Test Report No.T JP Date: FEB 22, 2017 Page 1 of 6

Detection of heavy metals in honey samples using Inductively Coupled Plasma Mass Spectrometry (ICP-MS)

DETERMINATION OF TRACE ELEMENTS IN WATERS AND WASTES BY INDUCTIVELY COUPLED PLASMA - MASS SPECTROMETRY EPA Method (Revision 5.

Application Note novaa 800 D. Determination of Macro and Trace Minerals as well as Toxic Trace Metals in Powdered Milk. Challenge.

Test Report No.T JP Date: FEB 24, 2017 Page 1 of 6

Bottom Ash Data Week 8

CERTIFICATE OF ANALYSIS. tel: fax:

Journal of Chemical and Pharmaceutical Research

Bottom Ash Data Week 12

Rapid determination of phosphate and citrate in carbonated soft drinks using ion chromatography

Trace Elemental Characterization of Edible Oils with Graphite Furnace Atomic Absorption Spectrophotometer

USP <232> and <233> Understanding Your Path to Compliance with the New Elemental Impurity Chapters. Steve Wall Agilent Technologies

LC-MS/MS Method for the Determination of Tenofovir from Plasma

Elemental Scientific. seafast S2. Elution Profiles. Elemental Scientific

Optimization of digestion methods for mineral in spirullina by Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES)

Impurity Profiling of Carbamazepine by HPLC/UV

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

Detection of oxygenated polycyclic aromatic hydrocarbons (oxy-pahs) in APCI mode with a single quadrupole mass spectrometer

Total Acid Number in petroleum products by automatic titration

METHOD 8316 ACRYLAMIDE, ACRYLONITRILE AND ACROLEIN BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC)

Elemental Scientific. Automated Speciation. prepfast-ic Chromium Speciation for Toy Materials (EN 71-3) ICP ICPMS AA

Improved Extraction and Analysis of Hexavalent Chromium from Soil and Water

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

Bottom Ash Data Week 1

Bottom Ash Data Week 40

Development and Validation of a Polysorbate 20 Assay in a Therapeutic Antibody Formulation by RP-HPLC and Charged Aerosol Detector (CAD)

METHOD DEVELOPMENT AND VALIDATION: QUANTIFICATION OF METALS IN LIQUIDS AND AEROSOL OF E-CIGARETTES

WAGENINGEN EVALUATING PROGRAMS FOR ANALYTICAL LABORATORIES. Certificate of Analysis. International Soil-Analytical Exchange REFERENCE MATERIAL

25-Hydroxyvitamin D2-D3 Serum VD-200 UHPLC Analysis Kit User Manual

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

More structural information with MS n

Comparison of Full Scan MS2 and MS3 Linear Ion Trap Approaches for Quantitation of Vitamin D

COMPARATIVE ANALYSIS FOR MACRO AND TRACE ELEMENTS CONTENT IN GOJI BERRIES BETWEEN VARIETIES FROM CHINA AND R. MACEDONIA

Internal Calibration System of Thermo Scientific Varioskan Flash with Improved Sensitivity, Accuracy and Dynamic Range

of human hair and nails. Part I. Analytical methodology, Sci. Tot. Environ. 2000, 250/1-3,

Vitamin D3 and related compounds by ESI and APCI

Supplementary Information for

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

Single particle ICPMS based methods for tracking environmental leaching of nanoparticles from consumer products

Selection and Optimization of the Sample Introduction System

TRACE ELEMENTS IN URINE. Event #1, 2010

Doubling the throughput of long chromatographic methods by using a novel Dual LC workflow

Considerations when Analyzing Real-World Samples by ICP Spectrometry

Electronic Supporting Information

Leaching Behavior of Coal Combustion Products and the Environmental Implication in Road Construction. Project Progress Report. Jianmin Wang NUTC R201

Detection and Quantification of Inorganic Arsenic in Fruit Juices by Capillary Ion Chromatography with Suppressed Conductivity Detection

Mass Directed Flash Chromatography by Biotage. Biotage Dalton Mass Detectors

ACQUITY UPLC WITH PDA DETECTION: DETERMINING THE SENSITIVITY LIMITS OF OXYBUTYNIN AND RELATED COMPOUNDS

Mercury Speciation Determinations in Asian Dietary Supplements

POLIMERSAN A.S. Orta Mahalle Universite Cd. 29 Orhanli-Tuzla Istanbul (EE)

POTENTIAL HEALTH RISK ASSESSMENT OF HEAVY METALS [Cd, Cu AND Fe] CONCENTRATIONS IN SOME IMPORTED FROZEN FISH SPECIES CONSUMED IN NIGERIA

Identification and Quantification at ppb Levels of Common Cations and Amines by IC-MS

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Supporting Information

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

ELEMENT 2/ ELEMENT XR Consumables and Parts Catalog

Quantitative Analysis of THC and Main Metabolites in Whole Blood Using Tandem Mass Spectrometry and Automated Online Sample Preparation

02006B 1 vial 02006B 1 vial Store at -20 C. Lyophilized recombinant IL-2

Direct determination of toxic trace metals in honey and sugars using inductively coupled plasma atomic emission spectrometry

Optimizing Sample. Chromium Analyses in Waters. Jane Timm, James Lovick Jr, Raymond Siery, ato 2011 NEMC, Bellevue, Washington

Test Report No.: GZHL IP Date: Sep 01, 2016 Page 1 of 12

Evaluation of an LC-MS/MS Research Method for the Analysis of 33 Benzodiazepines and their Metabolites

ICP-OES Organics Kit Installation Instructions

Transcription:

APPLICATION NOTE 43152 US EPA SW-846 Method 6010D using the Thermo Scientific icap 7400 ICP-OES Duo Authors James Hannan, Application Specialist, Thermo Fisher Scientific, Hemel Hempstead, UK Keywords Environmental analysis, SW-846 Method 6010D, US EPA Goal This application note describes the performance of the Thermo Scientific icap 7400 ICP-OES Duo for the analysis of environmental sample types by the US EPA Method 6010D. The icap 7400 ICP-OES Duo achieves short analysis times per sample whilst maintaining compliance with the protocol. Introduction On 21 October 1976, the United States (US) congress enacted the Resource Conservation and Act (RCRA), which governs the disposal of solid and hazardous waste. Guideline methods for the analysis of these types of samples are collated under Test methods for evaluating solid waste, physical/chemical methods Solid Wastes (SW)-846. One of the specified methods is US Environmental Protection Agency (EPA) Method 6010D Inductively Coupled Plasma-Optical Emission Spectrometry. This method prescribes the use of Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES) instrumentation for the determination of 31 elements in groundwaters, industrial and organic wastes, soils, sludges and sediments. All samples, except filtered groundwater, must be digested prior to analysis using either US EPA Method 3050B Acid Digestion of Sediments, Sludges, and Soils or US EPA Method 3051A Microwave Assisted Digestion of Sediments, Sludges, Soils, and Oils. US EPA Method 6010D is used within the USA and its variants are widely used in other regions, therefore the ability to undertake this type of analysis using US EPA Method 6010D represents an important benchmark for any ICP-OES instrument.

Instrumentation The Thermo Scientific icap 7400 ICP-OES Duo was used to analyze a selection of environmental sample types within the quality control framework of the US EPA Method 6010D. A duo instrument was selected as it enables elements expected at low concentrations to be measured axially for maximum sensitivity whilst elements expected at high concentrations can be measured radially. This allows the dynamic range of the instrument to be extended compared to that of an axial view only instrument. The instrument parameters used for this analysis are shown in Table 1. Table 1. Instrument parameters. Parameter Pump Tubing (Standard Pump) Pump Speed Spray Chamber Center Tube Nebulizer Setting Sample Tygon orange/white Drain Tygon white/white Internal Standard Tygon orange/blue 50 rpm Glass cyclonic 2 mm Glass concentric Nebulizer Gas Flow 0.7 L min -1 Auxiliary Gas Flow 0.5 L min -1 Coolant Gas Flow 12 L min -1 RF Power Exposure Time 1250 W UV 15 s, Vis 5 s Sample and standard preparation Solid samples were digested according to US EPA Method 3051A. A microwave digestion system (Ethos EZ SK10, Milestone) was used to digest 1 ± 0.005 g of sample in 2 ml of concentrated nitric acid ( 68% TraceMetal grade, Fisher Scientific, Loughborough, UK) and 6 ml of concentrated hydrochloric acid (34 37% TraceMetal grade, Fisher Scientific), this digestion extract was then made up to a final volume of 100 ml with ultra-pure deionized water (18.2 MΩ). Calibration standards were prepared in 6% hydrochloric acid v/v and 2% nitric acid v/v, and their element concentrations were selected to cover the required measurement range of each analyte. A 5 mg L -1 yttrium internal standard was automatically introduced online with the internal standard mixing kit. The internal standard wavelengths were appropriately matched to analyte wavelengths for each of the viewing modes, Axial/Radial and UV/Vis range. Details of the analyte wavelengths, plasma views and internal standard wavelengths selected are presented in Table 2. Method development and analysis A LabBook was setup using the Thermo Scientific Qtegra Intelligent Scientific Data Solution (ISDS) Software for the analysis of a selection of elements covered by the US EPA Method 6010D (Table 2). Table 2. Acquisition parameters. Wavelength (nm) Plasma view Internal standard (nm) Interfering elements Al 396.152 Radial Y 371.030 Ca As 189.042 Axial Y 224.306 N/A Ba 493.409 Axial Y 324.228 N/A Be 234.861 Axial Y 324.228 N/A Ca 422.673 Radial Y 371.030 N/A Cd 214.438 Axial Y 224.306 N/A Co 238.892 Axial Y 324.228 N/A Cr 357.869 Axial Y 324.228 N/A Cu 224.700 Axial Y 224.306 N/A Fe 259.940 Radial Y 371.030 N/A K 766.490 Radial Y 371.030 N/A Mg 202.582 Radial Y 371.030 Co, Na Mn 257.610 Axial Y 324.228 N/A Na 589.592 Radial Y 371.030 K Ni 341.476 Axial Y 324.228 N/A P 177.495 Axial Y 224.306 N/A Pb 261.418 Axial Y 324.228 Co, Fe Sb 206.833 Axial Y 224.306 N/A Se 196.090 Axial Y 224.306 N/A Tl 377.572 Axial Y 324.228 N/A V 292.402 Axial Y 324.228 N/A Zn 213.856 Axial Y 224.306 N/A *N/A not available Due to the unknown and potentially highly contaminated nature of waste and soil samples, significant spectral overlaps may be observed and therefore will need to be identified and either removed or compensated for. Single element solutions for each of the major and trace elements were analyzed as spectral interference checks (SIC) to check for their spectral contributions on other analytical elements. For concentrations of SIC solutions, see Table 3. Once identified, the Inter- Correction (IEC) function was used to calculate interference correction factors. The interferences observed with these solutions are detailed in Table 2.

Table 3. Single element SIC solutions. Concentration Na 1000 Al, Ca, Mg 500 Fe, Si 200 B, Ba, Cu, Mn 50 Other trace elements 20 Results and discussion Method detection limits (MDLs) were established by measuring a blank solution (6% HCl, 2% HNO 3 v/v). This solution was analyzed three times with each analysis having seven replicates; the standard deviation of the repeats for each of these analyses was multiplied by 3 and a mean value calculated to provide the MDL. These calculated MDLs can be seen in Table 4. Table 4. Method detection limits achieved. Wavelength (nm) View MDL (μg L -1 ) Al 396.152 Radial 6.91 As 189.042 Axial 1.74 Ba 493.409 Axial 0.13 Be 234.861 Axial 0.12 Ca 422.673 Radial 14.0 Cd 214.438 Axial 0.17 Co 238.892 Axial 0.93 Cr 357.869 Axial 0.68 Cu 224.700 Axial 0.85 Fe 259.940 Radial 3.92 K 766.490 Radial 31.8 Mg 202.582 Radial 28.0 Mn 257.610 Axial 0.15 Na 589.592 Radial 6.87 Ni 341.476 Axial 0.56 P 177.495 Radial 0.32 Pb 261.418 Axial 0.61 Sb 206.833 Axial 2.7 Se 196.090 Axial 0.82 Tl 377.572 Axial 0.30 V 292.402 Axial 0.79 Zn 213.856 Axial 0.23 The US EPA Method 6010D requires that a very strict quality control procedure should be followed to ensure the validity of sample data. Quality control checks should be carried out following instrument calibration, during sample analysis and at the end of the analytical run. All checks must meet the required US EPA Method criteria for the sample data to be valid. The instrument was set up using the parameters shown in Table 1. Immediately after calibration, an Initial Calibration Verification (ICV) solution and an Initial Calibration Blank (ICB) were analyzed. The validity of the calibration was verified through the analysis of a Continuing Calibration Verification (CCV) solution and Continuing Calibration Blank (CCB) after every 10 samples, and at the end of each analysis batch run. The ICB must return a result less than 0.5 times the Lower Limit of Quantification (LLOQ) for each element, while the ICV and CCV solutions must be within ±10% of the true values. The CCB must not contain target analytes above the LLOQ. Analysis of the CCV and CCB was then repeated every 10 samples and at the end of the analysis run to ensure the instrument remained in calibration, the results for the ICV and the first CCV are shown in Table 5. Table 5. Initial and continuing calibration verification checks (ICV & CCV). ICV CCV Al 0.504 100.9 2.463 98.5 As 0.496 99.1 2.508 100.3 Ba 0.515 103 2.55 102 Be 0.482 96.5 2.524 101 Ca 0.488 97.7 2.542 101.7 Cd 0.53 106 2.503 100.1 Co 0.496 99.3 2.412 96.5 Cr 0.492 98.3 2.493 99.7 Cu 0.501 100.2 2.436 97.4 Fe 0.47 93.9 2.379 95.2 K 0.461 92.2 2.453 98.1 Mg 0.509 101.9 2.453 98.1 Mn 0.469 93.8 2.476 99 Na 0.544 108.8 2.538 101.5 Ni 0.469 93.8 2.455 98.2 P 0.474 94.8 2.513 100.5 Pb 0.501 100.2 2.615 104.6 Sb 0.501 100.2 2.443 97.7 Se 0.523 104.7 2.578 103.1 Tl 0.518 103.5 2.521 100.8 V 0.496 99.2 2.41 96.4 Zn 0.499 99.9 2.522 100.9

The icap 7400 ICP-OES Duo includes a highly regulated temperature control system. This advanced temperature control technology ensures that the spectrum position remains constant with fluctuations in the laboratory conditions. This ensures that the long-term signal stability of the instrument is exceptional and that CCV samples are within acceptable levels for extended periods, resulting in fewer sample re-runs. Interference check solutions were analyzed prior to the start of the sample analysis in order to verify the accuracy of the IEC factors and the background correction points. A mixed SIC solution (SIC-A) was prepared containing 500 mg L -1 each of Al, Ca, Mg and 200 mg L -1 of Fe. Then, a spiked SIC solution (SIC-B) was prepared by spiking the SIC-A solution with concentrations of 0.1 to 1 mg L -1 for the analyte elements. The values measured for SIC-B must be within 20% of the true value for the data to be acceptable. The obtained data is shown in Table 6. Method performance was verified by analyzing two samples, a soil certified reference material (CRM) (#SQC001, lot 017309, RTC, Laramie, WY, USA) and a locally collected soil sample spiked with the equivalent of 100 mg kg -1 for each of the trace analytes and 1000 mg kg -1 for the major elements. The results of the spiked local soil and CRM samples as well as recoveries are shown in Table 7. Table 6. Interference check solutions and recoveries. SIC-A SIC-B Target value As <DL 0.299 0.30 99.8 Ba <DL 0.154 0.15 102.7 Be <DL 0.562 0.55 102.2 Cd <DL 0.763 0.80 95.4 Co <DL 0.476 0.50 95.2 Cr <DL 0.765 0.70 109.2 Cu <DL 0.424 0.45 94.1 K <DL 0.633 0.65 97.4 Mn <DL 0.867 0.90 96.4 Na <DL 0.427 0.40 106.7 Ni <DL 0.602 0.60 100.4 P <DL 0.883 0.85 103.9 Pb <DL 0.366 0.35 104.7 Sb <DL 0.102 0.10 102.2 Se <DL 0.741 0.75 98.7 Tl <DL 1.030 0.95 108.4 V <DL 0.183 0.20 91.3 Zn <DL 0.273 0.25 109.0 Table 7. Method validation check samples and recoveries. Unspiked sample Soil sample Spiked sample Soil CRM #SQC001 Certified value Al 9948 10965 101.8 11346 11100 102.2 As 2.20 107.9 105.7 219.4 202.0 108.6 Ba 62.56 169.0 106.4 669.0 662.0 101.0 Be 0.613 108.4 107.7 326.8 328.0 99.6 Ca 1964 2943 97.9 3239 3090 104.8 Cd 0.084 104.1 104.0 241.8 265.0 91.2 Co 6.16 105.5 99.3 286.1 314.0 91.1 Cr 17.76 127.5 109.7 244.3 232.0 105.3 Cu 8.369 105.4 97.0 80.30 88.40 90.8 Fe 16005 17040 103.5 8718 8850 98.5 K 1854 2881 102.8 9745 8890 109.6 Mg 1945 2913 96.8 2043 1890 108.1 Mn 214.3 307.6 93.2 1355 1370 98.9 Na 63.61 1008 94.4 4953 4890 101.3 Ni 12.51 118.6 106.0 81.29 76.50 106.3 P 320.6 426.6 106.0 340.0 371.0 91.6 Pb 86.16 194.3 108.1 57.26 55.90 102.4 Sb 0.914 104.8 103.9 133.4 125.0 106.7 Se <DL 107.8 107.8 155.4 144.0 107.9 Tl <DL 97.54 97.5 115.1 118.0 97.5 V 15.13 117.2 102.0 239.8 220.0 109.0 Zn 33.70 127.0 93.3 254.3 258.0 98.6

Conclusion The Thermo Scientific icap 7400 ICP-OES Duo exceeds the requirements needed to meet the US EPA Method 6010D protocol. The instrument includes a high resolution optical system which minimizes spectral interferences and reduces stray light. In addition, the advanced Charged Injection Device (CID) detector results in higher sensitivity and lower noise, which produces a high signal to background ratio. The simplified work flows of the Qtegra ISDS Software enable complex procedures to be easily adhered to using the automatic interference correction and quality control protocols. Using the method described, the time taken for each sample analysis was 2 minutes 35 seconds. This short analysis time leads to a low quantity of waste being produced and low consumable requirements, minimizing both the cost of analysis and its environmental impact. Find out more at thermofisher.com/icp-oes For Research Use Only. Not for use in diagnostic procedures. 2017 Thermo Fisher Scientific Inc. All rights reserved. TraceMetal is a trademark of Fisher Scientific. Tygon is a trademark of Saint-Gobain Corporation. All other trademarks are the property of Thermo Fisher Scientific and its subsidiaries. This information is presented as an example of the capabilities of Thermo Fisher Scientific products. It is not intended to encourage use of these products in any manner that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. AN43152-EN 0817