More structural information with MS n

Similar documents
Agilent 6410 Triple Quadrupole LC/MS. Sensitivity, Reliability, Value

Quadrupole and Ion Trap Mass Analysers and an introduction to Resolution

PTM Discovery Method for Automated Identification and Sequencing of Phosphopeptides Using the Q TRAP LC/MS/MS System

New Instruments and Services

Single Quadrupole Compact Mass Spectrometer for Liquid Sample

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

SYNAPT G2-S High Definition MS (HDMS) System

Rapid, Simple Impurity Characterization with the Xevo TQ Mass Spectrometer

Impurity Identification using a Quadrupole - Time of Flight Mass Spectrometer QTOF

LC/MS Crossroads. Jerry Pappas Sales Representative 265 Davidson Avenue Somerset, NJ

Introduction to LC/MS/MS

LC/MS/MS SOLUTIONS FOR LIPIDOMICS. Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS

Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System

SCS Mass Spectrometry Laboratory

Characterization of an Unknown Compound Using the LTQ Orbitrap

Increased Identification Coverage and Throughput for Complex Lipidomes

Introduction to the Oligo HTCS Systems. Novatia, LLC

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

Agilent s LC/MS Portfolio and Applications Examples

NIH Public Access Author Manuscript J Proteome Res. Author manuscript; available in PMC 2014 July 05.

Don t miss a thing on your peptide mapping journey How to get full coverage peptide maps using high resolution accurate mass spectrometry

Detection of oxygenated polycyclic aromatic hydrocarbons (oxy-pahs) in APCI mode with a single quadrupole mass spectrometer

Advances in Hybrid Mass Spectrometry

for the Identification of Phosphorylated Peptides

Liquid Chromatograph Mass Spectrometer LCMS-8040 C146-E188E

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

New Instruments and Services

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

Mass Directed Flash Chromatography by Biotage. Biotage Dalton Mass Detectors

Ion Source. Mass Analyzer. Detector. intensity. mass/charge

2. Ionization Sources 3. Mass Analyzers 4. Tandem Mass Spectrometry

application Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS

QSTAR Operation. May 3, Bob Seward

Ultra High Performance Liquid Chromatograph. Nexera X2 C196-E079

New Mass Spectrometry Tools to Transform Metabolomics and Lipidomics

Jose Castro-Perez, Henry Shion, Kate Yu, John Shockcor, Emma Marsden-Edwards, Jeff Goshawk Waters Corporation, Milford, MA, U.S. and Manchester, UK

Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations

MSQ. Hardware. Document No Revision 02 October 2003

Designer Cannabinoids

Comparison of mass spectrometers performances

Measuring Phytosterols in Health Supplements by LC/MS. Marcus Miller and William Schnute Thermo Fisher Scientific, San Jose, CA, USA

Applying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis

Vitamin D3 and related compounds by ESI and APCI

Shotgun Proteomics MS/MS. Protein Mixture. proteolysis. Peptide Mixture. Time. Abundance. Abundance. m/z. Abundance. m/z 2. Abundance.

The New 6495 Triple Quadrupole LC/MS

1. Sample Introduction to MS Systems:

Fundamentals of Soft Ionization and MS Instrumentation

2D-LC as an Automated Desalting Tool for MSD Analysis

Improving Selectivity in Quantitative Analysis Using MS 3 on a Hybrid Quadrupole-Linear Ion Trap Mass Spectrometer

Automated Purification and Analytical Reinjection of a Small Molecule Drug, Probenecid, on a Gilson LC/MS Dual Function System

Bioanalytical Quantitation of Biotherapeutics Using Intact Protein vs. Proteolytic Peptides by LC-HR/AM on a Q Exactive MS

Sample Concentration and Analysis of Human Hormones in Drinking Water

Quantitative Analysis of Opiates in Urine Using RRHT LC/MS/MS. Application. Authors. Introduction. Abstract. Forensics

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

Supporting information

Fast and easy separation of 23 drugs of abuse. including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS

Technical Note # TN-31 Redefining MALDI-TOF/TOF Performance

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

Mass Spectrometry at the Laboratory of Food Chemistry. Edwin Bakx Laboratory of Food Chemistry Wageningen University

amazon speed Innovation with Integrity Ion Trap Performance Beyond Imagination Ion Trap MS

Comparison of a UPLC Method across Multiple UHPLC Systems

Join the mass movement towards mass spectrometry

Essential Lipidomics Experiments using the LTQ Orbitrap Hybrid Mass Spectrometer

High-Throughput Analysis of Oligonucleotides using Automated Electrospray Ionization Mass Spectrometry

Components of a Mass Spectrometer

LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell 120 EC C18 Column

LECTURE 3. Ionization Techniques for Mass Spectrometry

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

Agilent 7700x ICP-MS

PosterREPRINT RAPID, SELECTIVE SCREENING OF URINE SAMPLES FOR GLUCURONIDES BY LC/MS/MS INTRODUCTION ABSTRACT

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

Mass Spectrometry Course Árpád Somogyi Chemistry and Biochemistry MassSpectrometry Facility) University of Debrecen, April 12-23, 2010

Comprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids

Agilent 6490 Triple Quadrupole LC/MS System with ifunnel Technology. Ultra sensitive quantitative performance

MALDI-TOF. Introduction. Schematic and Theory of MALDI

Ozonolysis of phospholipid double bonds during electrospray. ionization: a new tool for structure determination

MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager

Edgar Naegele. Abstract

Methods in Mass Spectrometry. Dr. Noam Tal Laboratory of Mass Spectrometry School of Chemistry, Tel Aviv University

Ultra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification

[ APPLICATION NOTE ] High Sensitivity Intact Monoclonal Antibody (mab) HRMS Quantification APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

LC-MS/MS Method for the Determination of Tenofovir from Plasma

Targeted and untargeted metabolic profiling by incorporating scanning FAIMS into LC-MS. Kayleigh Arthur

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices

MASS SPECTROMETRY BASED METABOLOMICS. Pavel Aronov. ABRF2010 Metabolomics Research Group March 21, 2010

Using Multiple Mass Defect Filters and Higher Energy Collisional Dissociation on an LTQ Orbitrap XL for Fast, Sensitive and Accurate Metabolite ID

Moving from targeted towards non-targeted approaches

amazon Turning Speed into Solutions

Workflow for Screening and Quantification of the SAMHSA (NIDA) Panel in Urine Using UHPLC-TOF

LC-MS/MS quantitative analysis of Polyunsaturated Omega 3, 6,7 and 9 Fatty Acids in Serum for

Quantitation of Protein Phosphorylation Using Multiple Reaction Monitoring

Amadeo R. Fernández-Alba

INTRODUCTION CH 3 CH CH 3 3. C 37 H 48 N 6 O 5 S 2, molecular weight Figure 1. The Xevo QTof MS System.

Determination of Amantadine Residues in Chicken by LCMS-8040

REDOX PROTEOMICS. Roman Zubarev.

Metabolomics: quantifying the phenotype

Analysis of Peptides via Capillary HPLC and Fraction Collection Directly onto a MALDI Plate for Off-line Analysis by MALDI-TOF

Transcription:

PRODUCT SPECIFICATIONS The LTQ XL linear ion trap mass spectrometer More structural information with MS n The LTQ XL linear ion trap mass spectrometer delivers more structural information faster and with more confidence. Product highlights Electron Transfer Dissociation (ETD) enabled Multiple dissociation techniques including PQD Extensive coverage for predicted and unpredicted metabolites Fast polarity switching for high sensitivity analysis of unknowns Intelligent Data Dependent acquisition Platform for hybrid MS n high resolution, accurate mass Improved Sensitivity in LC-MS Analysis Extended performance The LTQ XL extends the MS n performance of the LTQ linear ion trap with powerful new tools to generate extensive structural information for the most demanding proteomics and metabolism applications. With unparalleled sensitivity and ultra-fast cycle time, the LTQ XL delivers more information from less sample in less time. The unmatched high quality spectra of the LTQ XL in combination with powerful new software packages deliver complete solutions for your structural elucidation questions. The advanced Thermo Scientific Xcalibur Data Dependent software suite, which includes the MS 3 neutral loss experiment, enables rapid identification of post-translational modifications and metabolites. This feature greatly reduces the amount of time needed to analyze and interpret the data. Powerful software control and data processing in addition to innovative technology provide superior coverage for protein and metabolite analysis.

Hardware features Ion Max API source Enhanced sensitivity and ruggedness Sweep Gas reduces chemical noise 60 interchangeable ion probe orientation Removable metal ion capillary tube provides vent-free maintenance Transfer ion optics Advanced ion guides High stability and ion transmission efficiency 2D linear quadrupole ion trap mass spectrometer Optimized analyzer dimensions Regulated helium flow for stable performance Automatic system calibration High-efficiency radial ion ejection Vacuum System Differentially-pumped vacuum system to 10 5 Torr Split-flow turbomolecular pump controlling vacuum in three regions Dual rotary vacuum pump configuration High-vacuum aluminum analyzer chamber Detection System Patented dual conversion dynode detector Two off-axis continuous dynode electron multipliers with extended dynamic range Digital electronic noise discrimination Integrated divert valve Fully-automated data system control enables user to divert the solvent front, gradient end point and any other portion of the HPLC run to waste User-definable default state of the valve, either to waste or to source Integrated syringe pump Syringe Pump allows automated infusion under data system control Options ESI probe compatible with liquid flow rates of <1 μl/ min to 1 ml/min, without splitting APCI source compatible with liquid flow rates of 50 μl/min to 2 ml/min, without splitting APCI/APPI source compatible with liquid flow rates of 50 μl/min to 2 ml/min, without splitting Electron Transfer Dissociation (ETD) enabled vmaldi ion source combines the speed of MALDI with the sensitivity and selectivity of MS/MS Nanospray source supports static packed tip and dynamic nanospray experiments, compatible with liquid flow rates of 50 nl/min* to 2 μl/min Metal needle option for high- and low-flow analyses *Lower limit is dependent on gauge of needle used. Software features Data system Xcalibur processing and instrument control software Microsoft Office XP software package Microsoft Windows XP operating system High-performance PC with Intel Pentium microprocessor High-resolution LCD color monitor Scan functions Full-scan mass spectra for sensitive analyses and rapid screening of unknown compounds Selected Ion Monitoring (SIM) for selected ions for target compound analysis Full-scan product ion spectra at sensitivities higher than any ion trap mass spectrometer Selected Reaction Monitoring (SRM) for a traditional LC/MS/MS quantitative analytical experiment MS n for multi-stage MS experiments to probe the structure of ions ZoomScan, a high-resolution, full-range scan to resolve isotopic envelopes often used for charge state determination of peptides and ionization state determination of organometallics Ultra ZoomScan for ultimate resolution 2 TurboScan, an ultra-fast scan to improve signal-tonoise and sampling rate

Exclusive technologies Pulsed Q Collision Induced Dissociation (PQD) enables trapping of low mass fragment ions (Figure 1) Electron Transfer Dissociation (ETD) enabled capability delivers peptide sequence information not available from conventional methods High Resolution Isolation (HRI) allows for the separation of an isobaric interfering species down to 0.3 Da, or for isolation of a thermally labile compound Unique, patented Automatic Gain Control (AGC ) ensures that the ion trap is always filled with the optimum number of ions for any scan type Dynamic Exclusion allows acquisition of MS/MS and MS n spectra from lower intensity ion species WideBand Activation generates more structurally informative spectra Normalized Collision Energy compensates for the mass-dependent energy deposition characteristics of ion trap mass spectrometers in MS/MS experiments, providing reproducible data from instrument to instrument Stepped Normalized Collision Energy allows for the variation of the collision energies in an experiment Multistage Activation generates combination MS/MS spectra and MS 3 spectra based on a user defined neutral loss Resonance Excitation Amp Main RF Amp Kinetic Energy Internal Energy Fragment Intensity Step 1: Activation at High Q PQD Time Step 2: Delay at High Q HQD Time 0 100 200 300 400 500 600 700 800 900 Time (µsec) Step 3: Pulse to Low Q and Trap Fragments Figure 1. Schematic of Pulsed Q Collision Induced Dissociation Process. Advanced data dependent experiments Data Dependent features trigger acquisition of MS n spectra only when a compound of interest is detected Isotopic Data Dependent scanning software triggers MS/MS scanning only when a specified isotopic pattern is detected Triple Play determines the charge state and MS/MS scan range of a multiply charged ion N th Order Triple Play allows the number of ions undergoing a Triple Play to be defined Data Dependent Neutral Loss (NL) MS 3 triggers MS 3 scan only on the MS/MS product ions with the pre-defined neutral loss to identify and characterize metabolites and post-translational modifications Ion Mapping automatically generates a 3-dimensional MS/MS map, yielding product ion, precursor ion, and neutral loss information Ion Mapping Browser Software displays data generated by Ion Mapping experiments Data Dependent Ion Tree performs MS n experiments on up to 25 species Data Dependent Zoom Map generates sequential MS/MS experiments using a ZoomScan for charge state determination prior to each MS/MS experiment System specifications MS/MS sensitivity Electrospray ionization (ESI) A loop injection of 2 μl of a 125 fg/μl solution of reserpine (250 femtograms total sample) at a flow of 400 μl/min of 50% isopropyl alcohol/50% water will produce a minimum signal-to-noise ratio of 100:1, for the transition of the isolated protonated molecular ion at m/z 609 to the largest two product ions, 397 and 448, when the mass spectrometer is operated at unit resolution in the full-scan MS/MS mode, scanning the product ion spectrum from m/z 165 615. Atmospheric pressure chemical ionization (APCI) A loop injection of 2 μl of a 125 fg/μl solution of reserpine (250 femtograms total sample) at a flow of 400 μl/min of 50% isopropyl alcohol/50% water will produce a minimum signal-to-noise ratio of 100:1, for the transition of the isolated protonated molecular ion at m/z 609 to the largest two product ions, 397 and 448, when the mass spectrometer is operated at unit resolution in the full-scan MS/MS mode, scanning the product ion spectrum from m/z 165 615. 3

MS n sensitivity Electrospray Ionization (ESI) A loop injection of 2 μl of a 125 fg/μl solution of reserpine (250 femtograms total sample) at a flow of 400 μl/min of 50% isopropanol/50% water will produce a minimum signal-to-noise ratio of 25:1, for the transition of the unit isolated protonated molecular ion at m/z 609 to the product ion at m/z 397 which is further fragmented to the product ion at m/z 365, when the mass spectrometer is operated at unit resolution in the full-scan MS/MS mode, scanning the product ion spectrum from m/z 165 615 Installation requirements Power One 230 Vac ±10.0%, 15 Amps, 50/60 Hz,single phase, with earth ground dedicated to the instrument 120 or 230 Vac single phase, with earth ground for the data system Gas One high-purity (99% pure, flow rate 15 L/min) nitrogen gas supply for the API source One ultra high-purity helium gas supply (99.998% pure) with less than 1 ppm each of water, oxygen, and total hydrocarbons for the mass analyzer Environment System averages 2300 W (8000 Btu/h) output when considering air conditioning needs Operating environment must be 15 27 C (59 80 F) and relative humidity must be 40 80% with no condensation Optimum operating temperature is 18 21 C (65 70 F) Dimensions/weight MS: 56 79 59 cm (h w d) MS: ~120 kg Two roughing pumps: 38.6 kg each Performance specifications Mass range m/z 15 200 m/z 50 2000 m/z 200 4000 Linear dynamic range Under typical experimental conditions, at least four and a half (4.5) orders of magnitude Resolution, scan speed, and mass accuracy See Table 1 Polarity switching 100 msec between positive and negative MS scan power MS n, for n = 1 through 15 Contact closure Start In/Out Start Out is programmable Analog Inputs One (1) analog Input (0 1 V) One (1) analog Input (0 10 V) 461.0 425.3 537.2 650.8 471.9 749.0 638.0 630.1 462.4 404.6 419.5 445.6 455.7 416.5 Time (min) Figure 2. LC/MS analysis of an enzymatic digest of 4 fmol of myoglobin. 4

Table 1. Resolution, scan speed, and mass accuracy specifications. LTQ XL Mass Accuracy (Da) Peak Width (FWHM) Scan Rate (Da/Sec) Turbo 1.5 3 125,000 Normal 0.15 0.7 16,667 Enhanced 0.15 0.45 5,000 Zoom 0.15 0.3 1,111 Ultrazoom 0.15 0.15 28 itraq reporter ions itraq signature ion 145.0 273.11 b 1 291.26 y 1 420.3 (M+2H) 2+ 567.4 671.2 663.3 b 4 679.9 y 2 695.5 y 3 y 4 114 115 116 117 113.5 114.0 114.5 115.0 115.5 116.0 116.5 117.0 m/z m/z Intensity Relative 114 831 1.00 115 768 0.92 116 829 0.98 117 841 1.01 228.2 245.13 b 2 387.3 b 3 456.3 548.3 646.3 b 5 b 6 1085.5 y 5 1068.5 y 7 y 6 791.4 810.5 938.5 910.5 971.5 1196.5 1213.5 100 200 300 400 500 600 700 m/z 800 900 1000 1100 1200 Figure 3. PQD spectrum for QNCDQFEK in BSA digest derivatized with the four itraq reagents mixed together at a ratio of 1:1:1:1. Find out more at thermofisher.com 2016 Thermo Fisher Scientific Inc. All rights reserved. SEQUEST is a registered trademark of the University of Washington. Intel and Pentium are registered trademarks of Intel Corporation. Microsoft and Windows are registered trademarks of Microsoft Corporation. itraq is a trademark of Applera Corporation. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms, and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. PS62357-EN 1116S