The effects of computed tomography derived low doses on human peripheral blood cells

Similar documents
Managing Patient Dose in Computed Tomography (CT) INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION

Assessment of Individual Radiosensitivity in Human Lymphocytes using Micronucleus and Microgel Electrophoresis Comet Assays

Managing Patient Dose in Computed Tomography (CT)

LYMHOCYTE CHROMOSOMAL ABERRATION ASSAY IN RADIATION BIODOSIMETRY

Why is CT Dose of Interest?

Cell Viability, DNA Damage And Relative Mitotic Arrest Dependence On Radiation Dose

Clastogenic factors in blood plasma obtained from subjects exposed to. Carita Lindholm STUK - Radiation and Nuclear Safety Authority

X-Ray & CT Physics / Clinical CT

Radiation and Cancer Risk

CURRENT CT DOSE METRICS: MAKING CTDI SIZE-SPECIFIC

ESTABLISHING DRLs in PEDIATRIC CT. Keith Strauss, MSc, FAAPM, FACR Cincinnati Children s Hospital University of Cincinnati College of Medicine

RADIATION SAFETY. Junior Radiology Course

8/18/2011. Acknowledgements. Managing Pediatric CT Patient Doses INTRODUCTION

Change in frequency of radiation induced micronuclei during interphase of four-cell mouse embryos in vitro

"The Good Side of Radiation: Medical Applications"

Clinical Image Gallery Next Generation Volume 1

The radiotracer 99m Tc-MIBI is not genotoxic for human peripheral blood lymphocytes at diagnostic radioactive dose

Background Radiation in U.S. ~ msv/yr msv/yr ~0.02 ~0.02 msv msv/day /day (~2 m rem/day) mrem/day) NCRP 4

Radiation induced DNA double strand breaks undergoing PET/CT examinations.

Survey of patients CT radiation dose in Jiangsu Province

Lecture -2- Environmental Biotechnology

A multicentric study on patient dose in multislice CT

Mugimane Manjanatha, Ph.D

Genotoxic and acute toxic properties of selected synthetic cannabinoids

Online publication date: 28 January 2010 PLEASE SCROLL DOWN FOR ARTICLE

Measurement of organ dose in abdomen-pelvis CT exam as a function of ma, KV and scanner type by Monte Carlo method

Introduction and Background

Justification, Optimization and Communication in Pediatric CT Imaging: Recent Improvements and Persistent Challenges Designated Emphasis in Nuclear

DNA damage in subpopulations of human lymphocytes irradiated with doses in the range of 0 1 Gy of X-radiation

Radiation Protection- Cath lab

Genotoxic effects of 60 Co γ-rays on Chinese hamster ovary (CHO) cells

CT Dose Estimation. John M. Boone, Ph.D., FAAPM, FSBI, FACR Professor and Vice Chair of Radiology. University of California Davis Medical Center

UNIVERSITY OF SOUTH ALABAMA RADIOLOGIC SCIENCES

Dako IT S ABOUT TIME. Interpretation Guide. Agilent Pathology Solutions. ALK, ROS1 and RET IQFISH probes (Dako Omnis) MET IQFISH probe (Dako Omnis)


Managing the imaging dose during Image-guided Radiotherapy. Martin J Murphy PhD Department of Radiation Oncology Virginia Commonwealth University

Regional diagnostic reference levels and collective effective doses from CT scanners in India

Managing Radiation Risk in Pediatric CT Imaging

Radiation Dose Risk and Diagnostic Benefit in Imaging Investigations

Radiation related cancer risk & benefit/risk assessment for screening procedures

Session 3 Radiation effects and health risks from radiation exposure at the workplace Contributed papers

Debra Pennington, MD Director of Imaging Dell Children s Medical Center

IMAGE GENTLY HOW CAN YOU HELP?

Ionizing Radiation Exposure of the Population of the United States. David A. Schauer Executive Director

Assessment of effective dose in paediatric CT examinations

Radiation exposure of the Yazd population from medical conventional X-ray examinations

The radiation dose in retrospective

Doses from pediatric CT examinations in Norway Are pediatric scan protocols developed and in daily use?

created by high-voltage devices Examples include medical and dental x-rays, light, microwaves and nuclear energy

Biological Dosimetry Method: a Probable way for Measuring Percent Depth Dose

Relative Survival Rate

Managing the imaging dose during image-guided radiation therapy

Expanding therapy options for

Onion (Allium cepa) genotoxicity test

CT Head Dose Reduction Using Spiral Scanning Protocol

Current status of diagnostic imaging in dental university hospitals in Japan

CT Quality Control Manual FAQs

ROMANIA MEDICAL EXPOSURE IN 2016 IN ROMANIAN RADIOLOGICAL DEPARTMENTS. Olga GIRJOABA and Alexandra CUCU

CT Radiation Risks and Dose Reduction

Pitfalls and Remedies in PET/CT imaging for RT planning

Exercise 6. Procedure

In Vitro Evaluation of Genotoxic Effects under Magnetic Resonant Coupling Wireless Power Transfer

Biological Effects of Ionizing Radiation Module 8 - AAPM/RSNA Curriculum. Basic Radiation Biology

Outline. NCRP Scientific Committee 6-2

Radiology. General radiology department. X-ray

GAFCHROMIC DOSIMETRY MEDIA TYPE MD-V3

ADVANTAGES OF MICRONUCLEI ANALYSIS THROUGH IMAGES AUTOCAPTURING AND SCREEN SCORING

Cellular Stress Response Induced by Low Dose Gamma Radiation

An Assessment of Organ and Effective Dose of Patients who Undertake CT Examinations in two Teaching Hospitals of Mashhad&Isfahan

Doses from Cervical Spine Computed Tomography (CT) examinations in the UK. John Holroyd and Sue Edyvean

Sources of Data of Stochastic Effects of Radiation. Michael K O Connor, Ph.D. Dept. of Radiology, Mayo Clinic

A more accurate method to estimate patient dose during body CT examinations with tube current modulation

Fetal Dose Calculations and Impact on Patient Care

Introduction Pediatric malignancies Changing trends & Radiation burden Radiation exposure from PET/CT Image gently PET & CT modification - PET/CT

Prediction of Organ and Effective dose with known mas and kvp for dose Optimisation Protocol and Recommendations in CT

Developing Auto-focusing Microscopy For Ultra High- Throughput Biodosimetry

Early in Life. Noboru Takamura, M.D., Ph.D.

Toshiba Aquillion 64 CT Scanner. Phantom Center Periphery Center Periphery Center Periphery

Tracking Doses in the Pediatric Population

Radiation Dose To Pediatric Patients in Computed Tomography in Sudan

Chief Radiographer TEI Clinical Associate 2016

Polymorphism of XRCC1 Gene Exon 6 (Arg194Trp) in Relation to Micronucleus Frequencies in Hospital Radiation Workers

Utilize radiation safety principles to reduce the amount of radiation used to achieve desired clinical result.

OPTION I TEST REVIEW

Combined Anatomical and Functional Imaging with Revolution * CT

Low-dose CT Lung Cancer Screening Guidelines for Pulmonary Nodules Management Version 2

Evaluation of genome damage in subjects occupationally exposed to possible carcinogens. D. Želježi, M. Mladini, N. Kopjar, A. Hursidic Radulovic

Comparison of Radiation-Induced Bystander Effect in QU-DB Cells after Acute and Fractionated Irradiation: An In Vitro Study

CT Dose Reduction in Pediatric Patients

3/5/2015. Don t Electrocute Me!: Common Misconceptions in Imaging and Radiation Safety (and What to Do About Them)

Specific Aspects of Radiochromic Film Dosimetry AAPM Task Group 235 An Update to Task Group 55 (1998)

Cell Division. Learning Objectives: Introduction. Revised Fall 2018

TomoTherapy. Michelle Roach CNC Radiation Oncology Liverpool Hospital CNSA. May 2016

Patient doses from X-ray computed tomography examinations by a single-array detector unit: Axial versus spiral mode

Testing of the Implementation of the Code of Practice on Dosimetry in X-ray Diagnostic Radiology Hungarian Contribution

LOW DOSES OF RADIATION REDUCE RISK IN VIVO

Application of chromosomal radiosensitivity assays to temporary nuclear power plant workers

Radiation Safety For Anesthesiologists. R2 Pinyada Pisutchareonpong R2 Nawaporn Sateantantikul Supervised by Aj Chaowanan Khamtuicrua

CT Fluoroscopy-Guided vs Multislice CT Biopsy ModeGuided Lung Biopies:a preliminary experience

Transcription:

The effects of computed tomography derived low doses on human peripheral blood cells Piroska Virág The Oncology Institute Prof. Dr. I. Chiricuta, Cluj-Napoca, Romania Low dose radiation effects on the immune system: current knowledge and future research needs 5th to 7th November 2013, Budapest, Hungary

Introduction Persons at risk for repeated radiation exposure (healthcare professionals, nuclear industry workers) are regularly monitored and restricted to effective doses of 100 msv every 5 years (max. 50 msv/year); Radiation exposure in patients who underwent medical imaging procedures is not typically monitored; Diagnostic imaging using x-rays continue to be the most common application of radiation in medicine (radiography, fluoroscopy, computed tomography, interventional radiology and bone densitometry); As the use of computed tomography (CT) has increased rapidly in the past few years, we considered that evaluations in patients who have undergone this examination can provide some valuable information on radiation risk; The aim of our study was to estimate the immediate cytogenetic effects of the exposure to low doses of irradiation on human peripheral blood cells during CT examination.

Computed tomography (CT) Inception of CT in 1970; Use has increased rapidly (7 fold for the entire population in the past decade; 15% of the total x-ray examinations; 70% of the radiation doses from medical procedures); The reasons for the increase in utilization: extremely rapid scanning; user-friendly three-dimensional software programs and multi-plannar imaging; CT involves higher radiation doses than the conventional x-ray imaging procedures (10-20 mgy vs. 0.02-10 mgy); Doses (expressed in absorbed dose, organ dose or effective dose) depend on a variety of factors: number of scans; tube current; tube voltage; the size of the patient; the scan pitch; the slices thickness etc. CT types: - axial CT for head scans; - helical or spiral CT for body scans; Indications: - diagnosis in sympthomatic patients; - screening in asympthomatic patients.

Patients and methods Patients: 13 untreated subjects, with different types of malignancies, subjected to CT, divided into two groups: - 6 were given cranial CT (CRN-CT), Pace (General Electrics, Japan) - mean absorbed dose of 17.5 mgy; - 7 thorax-abdomen-pelvis CT (TAP-CT), Aura (Philips, Netherlands) - mean absorbed dose of 43.85 mgy ; blood samples were collected before and immediately after CT; determinations were assessed on whole blood or peripheral blood mononuclear cells (PBMCs) isolated from whole blood in density gradient. Methods: the basal DNA lesions and those induced by irradiation were determined in fresh blood cells by Single Cell Gel Electrophoresis or Comet assay (CA); the potential chromosomal aberrations, induced by ionizing radiations were evaluated from cryopreserved PBMCs with Cytokinesis Blocked Micronucleus assay (CBMA); statistical processing of the experimental data was accomplished using GraphPad Prism software program, version 5.0 (GraphPad, San Diego, Ca, USA) and Excel. Statistical comparison between groups was made by t Student Test (p<0.05 statistical significance).

Single Cell Gel Electrophoresis or Comet assay (CA) Is a highly sensitive method for the assessment of DNA damage formation and repair (Tice et al., 2000), briefly: leukocytes from whole blood were embedded in low melting agarose; cells were layered onto slides precoated with normal melting agarose; the cell-slides were immersed in lyses solution to remove all non-nucleic material; electrophoresis was conducted in alkaline buffer (ph 13.2) at a field strength of 25V/300mA; slides were neutralized, fixed with ethanol, stained with Ethidium bromide and incubated in the dark; for the visualization of DNA damage an epifluorescent microscope was used (excitation filter: 510-560 nm, barrier filter: 590 nm) and 200 cells were analyzed per sample.

Representations of comet images and classes and parameters calculated by CA: lesion score (LS) and tail factor (TF) SL [UR]= A 0+B 1+C 2+D 3+E 4 A,B,C,D,E number of cells in comet classes 0,1,2,3,4 5 TF [%] = (A FA+ B FB+ C FC+ D FD+ E FE)/ Total number of cells A,B,C,D,E number of cells in comet classes 0,1,2,3,4 FA-FE mean proportion of DNA in the comet tail

The Cytokinesis Block MicroNucleus assay (CBMA) Is one of the most used methods for assessing unstable chromosomal aberrations, such as acentric chromosomal fragments, which are visible in interphase as extra nuclear corpuscles named micronuclei (Fenech, 2000), briefly: PBMCs isolated before and after CT were treated with Phytohemagglutinin M (PHA) to stimulate cell division and to ensure maximum yield of binucleated cells (20 µg PHA/ml cell culture); Cytochalasin B (Cyt B) was added to block cytokinesis process after 44 hours of incubation (6 µg Cyt B/ml cell culture); cells were harvested by cytocentrifugation at the end of the 28 hours incubation with Cyt B; the cells were stained with Giemsa 10% and examined at 1000x magnification.

Representations of binucleated cells and micronuclei and mathematical values obtained by CBMA Percentage of binucleated cells with micronuclei (%Bi+Mni) Number of micronuclei in 1000 binucleated cell (Nr.Mni/1000Bi) Giemsa stain, 1000x

Mean values of the CA determinations expressed by: lesion score (LS) and tail factor (TF) in patients subjected to CT LS [UR] TF [UR] 160 18 140 120 100 * * 16 *** 14 ** 12 ** ** 80 60 LS-before CT LS-after CT 10 8 6 TF-before CT TF-after CT 40 4 20 2 0 1 2 3 0 1 2 3 1-CRN; 2-TAP; 3-global evaluation

Mean values of the CBMA determinations evaluated by: %Bi+Mni and Nr.Mni/1000Bi in patients subjected to CT %Bi+Mni Nr.Mni/1000Bi 5 4.5 ** 0.05 0.045 * 4 0.04 3.5 0.035 3 0.03 2.5 %Bi+Mni 0.025 Nr.Mni/1000Bi 2 0.02 1.5 0.015 1 0.01 0.5 0.005 0 before CT after CT 0 before CT after CT Global evaluation

Conclusions Low-doses of irradiations, provided by CT, can cause detectable cytogenetic modifications in human blood cells, immediately after exposure, which consists of DNA lesions and chromosomal aberrations. There are noticeable interindividual differences between basal levels of DNA lesions and chromosomal aberrations. The DNA lesions after CT were higher in the cranial CT group. Since, the risks of radiation are cumulative, it is essential to radiologists to reduce to the minimum the radiation dose delivered by each CT scan administered. The data presented in this work are the results of a preliminary study of the low dose radiation effects in human blood cells. For a more accurate evaluation it is recommendable to increase the number of study cases.