International Journal of Biological and Medical Sciences

Similar documents
vii LIST OF TABLES TABLE NO DESCRIPTION PAGE 1.1 System Suitability Parameters and Recommendations Acidic and Alkaline Hydrolysis 15

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

IJPAR Vol.3 Issue 4 Oct-Dec-2014 Journal Home page:

Hyderabad, India. Department of Pharmaceutical Chemistry, Glocal University, Saharanpur, India.

METHOD DEVELOPMENT AND VALIDATION BY RP-HPLC FOR ESTIMATION OF ZOLPIDEM TARTARATE

RP-HPLC Analysis of Temozolomide in Pharmaceutical Dosage Forms

Journal of Chemical and Pharmaceutical Research, 2017, 9(9): Research Article

CHAPTER 3: ANALYTICAL METHOD DEVELOPMENT AND VALIDATION

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

Pelagia Research Library

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

Available online at Scholars Research Library

Scholars Research Library

Journal of Pharmaceutical and Bioanalytical Science

International Journal of Pharma and Bio Sciences DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR THE ESTIMATION OF STRONTIUM RANELATE IN SACHET

Determination of propranolol in dog plasma by HPLC method

Journal of Chemical and Pharmaceutical Research

Development and Validation of a Simultaneous HPLC Method for Quantification of Amlodipine Besylate and Metoprolol Tartrate in Tablets

Development, Estimation and Validation of Lisinopril in Bulk and its Pharmaceutical Formulation by HPLC Method

Development and validation of stability indicating RP-LC method for estimation of calcium dobesilate in pharmaceutical formulations

Pelagia Research Library

Development and Validation for Simultaneous Estimation of Sitagliptin and Metformin in Pharmaceutical Dosage Form using RP-HPLC Method

SIMULTANEOUS ESTIMATION OF VALSARTAN AND HYDROCHLOROTHIAZIDE IN TABLETS BY RP-HPLC METHOD

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS TOLBUTAMIDE IN PURE AND PHARMACEUTICAL FORMULATIONS

Scholars Research Library. Der Pharmacia Lettre, 2015, 7 (5):44-49 (

Journal of Chemical and Pharmaceutical Research, 2013, 5(1): Research Article

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page:

Journal of Chemical and Pharmaceutical Research, 2018, 10(2):1-5. Research Article. RP- HPLC Method for Estimation of Furosemide in Rabbit Plasma

World Journal of Pharmaceutical Research

Research Article. Liquid-liquid extraction method for Ziprasidone (ZRS) bioanalysis by using ZRS-D 8 (stable isotope) as internal standard

Available online Research Article

ISSN: ; CODEN ECJHAO E-Journal of Chemistry 2011, 8(3),

Development and validation of RP-HPLC method for simultaneous estimation of gliclazide and metformin in pure and tablet dosage form

RP-HPLC METHOD DEVELOPMENT AND VALIDATION FOR THE ESTIMATION OF BACLOFEN IN BULK AND PHARMACEUTICAL DOSAGE FORMS

Stability indicating RP-HPLC method development and validation of Etizolam and Propranolol hydrochloride in pharmaceutical dosage form

Reverse Phase HPLC Analysis of Atomoxetine in Pharmaceutical Dosage Forms

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.

Validation of UV Spectrophotometric and HPLC Methods for Quantitative determination of Iloperidone in Pharmaceutical Dosage Form

New RP-HPLC Method for the Determination of Fludarabine in Pharmaceutical Dosage Forms

J Pharm Sci Bioscientific Res (4): ISSN NO

LC-MS/MS Method for the Determination of Tenofovir from Plasma

Development and validation of related substances method for Varenicline and its impurities

RP-HPLC Method Development and Validation of Abacavir Sulphate in Bulk and Tablet Dosage Form

F. Al-Rimawi* Faculty of Science and Technology, Al-Quds University, P.O. Box 20002, East Jerusalem. Abstract

HPLC-UV Determination of Abacavir Sulphate in Pharmaceutical Dosage Forms

A New Stability-Indicating and Validated RP-HPLC Method for the Estimation of Liraglutide in Bulk and Pharmaceutical Dosage Forms

New RP - HPLC Method for the Determination of Valproic acid in Human Plasma

International Journal of Pharma and Bio Sciences

ISSN (Print)

Determination of Tetracyclines in Chicken by Solid-Phase Extraction and High-Performance Liquid Chromatography

Int. J. Pharm. Sci. Rev. Res., 30(1), January February 2015; Article No. 32, Pages:

DEVELOPMENT OF RP-HPLC METHOD FOR ESTIMATION OF DROTAVERINE HYDROCHLORIDE IN PHARMACEUTICAL FORMULATIONS

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

DETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS

Determination and pharmacokinetics of manidipine in human plasma by HPLC/ESIMS

retardation in infants. A wide variety of analytical methods for the analysis of

CHAPTER 2 SIMULTANEOUS DETRMINATION OF ANASTROZOLE AND TEMOZOLOMIDE TEMOZOLOMIDE CAPSULES 20 MG AND ANASTROZOLE TABLETS 1 MG

DEVELOPMENT AND VALIDATION OF NEW HPLC METHOD FOR THE ESTIMATION OF PALIPERIDONE IN PHARMACEUTICAL DOSAGE FORMS

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

Journal of Chemical and Pharmaceutical Research, 2018, 10(3): Research Article

Development and Validation of Stability Indicating HPLC method for Determination of Eperisone HCL in Bulk and in Formulation

Application Note. Author. Abstract. Introduction. Food Safety

Simultaneous Estimation of Gemcitabine Hydrochloride and Capecitabine Hydrochloride in Combined Tablet Dosage Form by RP-HPLC Method

A stability indicating RP-HPLC method for simultaneous estimation of darunavir and cobicistat in bulk and tablet dosage form

Scholars Research Library

Application Note. Authors. Abstract. Food

Development and Validation of a Polysorbate 20 Assay in a Therapeutic Antibody Formulation by RP-HPLC and Charged Aerosol Detector (CAD)

Development and Validation of Stability Indicating HPTLC Method for Estimation of Seratrodast

Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column

A HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC ASSAY FOR LERCANIDIPINE HYDROCHLORIDE

Available online Research Article

Development and Validation of RP-HPLC Method for the Estimation of Gemigliptin

Determination of Clarithromycin in Human Plasma by LC-EI Tandem Mass Spectrometry: Application to Bioequivalence Study

Simultaneous estimation of Metformin HCl and Sitagliptin in drug substance and drug products by RP-HPLC method

36 J App Pharm Vol. 6; Issue 1: 36-42; January, 2014 Rao et al., 2014

Application Note. Agilent Application Solution Analysis of fat-soluble vitamins from food matrix for nutrition labeling. Abstract.

A Validated Chiral Liquid Chromatographic Method for The Enantiomeric Separation of Dapoxetine Hydrochloride

Journal of Chemical and Pharmaceutical Research, 2012, 4(1): Research Article

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

RP- HPLC and Visible Spectrophotometric methods for the Estimation of Meropenem in Pure and Pharmaceutical Formulations

Analytical Method Development and Validation for the Estimation of Guaifenesin and Dextromethorphan by RP-HPLC

SIMULTANEOUS QUANTIFICATION OF TELMISARTAN AND METOPROLOL SUCCINATE IN TABLETS BY LIQUID CHROMATOGRAPHY

Ankit et al Journal of Drug Delivery & Therapeutics; 2013, 3(2), Available online at RESEARCH ARTICLE

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Quantification of Budesonide Using UPLC and Xevo TQ-S

Analysis of Rosuvastatin in Dried Blood Spot and Plasma Using ACQUITY UPLC with 2D Technology

ANALYTICAL TECHNIQUES FOR THE QUALITY OF ANTI- AIDS DRUGS

HPLC method for Pharmacokinetics of cis and trans isomer of cefprozil diastereomers in human plasma

A New RP-HPLC Method for the Simultaneous Estimation of Naltrexone Hydrochloride and Bupropion in Its Pure and Pharmaceutical Dosage Form

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS OF TRAMADOL IN PURE AND PHARMACEUTICAL FORMULATIONS

Journal of Chemical and Pharmaceutical Research

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD ESTIMATION OF TOLVAPTAN IN BULK PHARMACEUTICAL FORMULATION

Highly sensitive simultaneous quantitative analysis of estrone and equilin from plasma using LC/MS/MS

Pharmacologyonline 1: (2010) Newsletter Mohan et al.


International Journal of Research in Pharmaceutical and Nano Sciences Journal homepage:

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR ESTIMATION OF LACOSAMIDE IN BULK AND ITS PHARMACEUTICAL FORMULATION

Transcription:

International Journal of Biological and Medical Sciences Vol. 1, Issue, 1, p7-11, 01 January, 2017 Available online at http://www.injbms.com Original Article Bioanalytical assay validation of CYP2E1 marker chlorzoxazone in human plasma: Application for protein binding study Siddhartha Singh a*, Neerja Trivedi b, Devendra Kumar c a Division of Pharmaceutics, National Institute of Pharmaceutical Education Research. Raebareli, India b Center of Biomedical Research. Lucknow, India c Department of Pharmacology and Therapeutics. KGMU, Lucknow, India Article History: Received 10 September 2016 Received in revised form 10 November 2016 Accepted 30 November 2016 Published online 01 January 2017 Key Words Chlorzoxazone Phenacetin Human plasma Protein binding * Corresponding Author singh.siddhartha59@gmail.com Abstract A simple and precise HPLC-PDA method was developed for the quantification of chlorzoxazone in human plasma using phenacetin as internal standard. The analyte and internal standard were extracted from the plasma sample using simple protein precipitation method. Chromatographic separation was achieved on a Thermo (250 4.6 mm, 5 µm) column with a mobile phase consisting TDW and acetonitrile in gradient manner at a flow rate of 1.0 ml /min. The assay was validated with a linear range of 0.12-8 µg /ml for chlorzoxazone using 200 µl of plasma sample. The intraand inter-day assay precision ranged from 3.03% to 1.18% and 2.63 to 5.9%, respectively, and intra and inter-day assay accuracy was between from 2.85 to 6.4% and 3.12% to 6.5%, respectively. The method was successfully applied to the protein binding studies of chlorzoxazone in human plasma. INTRODUCTION Chlorzoxazone (5-chloro-3H-benzooxazol-2-one) (Fig 1), is an efective muscle relaxant. It is a centrally acting agent for painful musculoskeletal conditions (1). Its main metabolite is 6- hydroxychlorzoxazone; it has been proposed that this metabolic pathway could be a useful marker for the activity of cytochrome P4502E1 (CYP2E1) (2, 3). Chlorzoxazone acts primarily at the level of the spinal cord and subcortical areas of the brain where it inhibits ultisynaptic reflex arcs involved in producing and maintaining skeletal muscle spasm of varied etiology. It is used to decrease muscle tone and tension and thus to relieve spasms and pain associated with musculoskeletal disorders Various analytical methods for therapeutic monitoring have been reported in the literature for the determination of Chlorzoxazone in commercial dosage form and biological fluids such as highperformance liquid chromatography (HPLC) (4) reverse phase high performance liquid chromatography (RP-HPLC) (5) spectrometry (LC-ESI-MS/MS)(6) and spectrophoto (7). The main problems encountered in using such methods are either the need for derivatization or the need for time consuming extraction procedures. Chlorzoxazone (Analyte ) Phenacectin (IS) Fig.1 Structure of Chlorzoxazone (analyte) and phenacetin (IS) There are, however, a few simple precise and rapid methods for determining the plasma concentration of chlorzoxazone in patients, they are much less those using high performance liquid chromatography (HPLC). Most existing methods require tedious procedures or require special equipment. That is why the aim of this study was to standardize simple, precise selective, highly robust

RP- HPLC method a method for determining the concentration of chlorzoxazone in human plasma. This method was applicable for protein binding study in human plasma. MATERIAL AND METHODS Chemicals and Materials Chlorzoxazone and phenacetin (Internal standard, IS) were obtained from Sigma Aldrich (St.Louis, MO). HPLC grade acetonitrile and methanol were from Sigma Aldrich Chemicals Pvt Ltd (Mumbai, India). Sodium acetate AR, glacial acetic acid AR, and ammonia solution (25%) were purchased from E Merck Pvt. Ltd (Mumbai, India). Potassium chloride was purchased from SRL pvt. Ltd Mumbai Ultrapure water was obtained from a Milli-Q PLUS PF water purification system. Heparin sodium injection I.P. (1000 IU/mL) was purchased from Biologicals E. Limited (Hyderabad, India). Human plasma was collected as per the guidelines of the institutional ethics committee. Instrumentation and chromatographic conditions The method was developed using a Waters HPLC system (Milford USA) consisted of a binary pump (model 515), auto sampler (model 717) connected to waters 2996 Photo diode Array detector. The separation was achieved on Thermo (250 4.6 mm, 5 µm) column with a mobile phase consisting TDW and acetonitrile in a gradient at a flow rate of 1 ml/ min. Detection range of PDA detector was 200-500nm. Detection was carried out with PDA at 279 nm wave lenght. Total run time was 14 min and volume of injection was 50 μl, prior to injection of analyte, the column was equilibrated for 30-40 min with mobile phase. Analysis was performed at ambient temperature. The data collection and analysis were performed using breeze - version 3.1 software. Preparation of Stock and standard Solution Chlorzoxazone and IS stock solutions for CS samples were prepared in acetonitril (normal concentrations 1.0 mg/ml). CS samples were prepared by spiking respective stock solutions in blank human plasma at concentrations of 0.12, 0.25, 0.5, 1, 2, 4, and 8 µg/ml. CS samples were prepared from a blank plasma pool. Chlorzoxazone stock solution for QC was prepared separately. QC samples at three different concentrations (0.12, 1 and 8 µg/ml as LLOQ, medium and high, respectively) were prepared separately in five replicates, independent of the calibration standards. Calibration curves were plotted as concentration of drugs versus peak area response. QC samples were prepared from different matrix pools on each day of analysis. All prepared plasma samples were stored at -15ºC or below and all prepared stock solutions were stored at a 4 C. Sample Preparation Calibration standard, QC and plasma-protein binding samples were extracted using protein precipitation method (8). An aliquot of sample mixture (200 µl) of blank human plasma mixed with 10 µl of internal standard (5µg/ ml). In 180 µl of plasma add 10 µl of chlorzoxazone (stock cc) and 10 µl of IS. Vortex it for 2 min. Prior to analysis, all frozen samples were thawed and allowed to equilibrate at room temperature. To an aliquot of 200 µl of spiked plasma sample and 20 ml internal standard (5 mg/ ml) were added and vortexed for 20 s. Then, 600 ml of acetonitrile was added to precipitate plasma protein. The sample was then vortexed vigorously for 2 min and centrifuged at 12,000 rpm for 15 min. The supernatant organic layer was transferred to clean test tube, dried and finally reconstituted in 200 µl acetonitrile. The reconstituted solution was transferred into a 300 µl autosampler vials and 50 µl was injected into HPLC. Recovery The recovery of chlorzoxazone and IS, was determined by comparing the responses of the analytes extracted from replicate QC samples (n = 5) with the response of analytes from postextracted plasma samples at equivalent concentration. Recoveries of chlorzoxazone were determined at QC low, QC medium and QC high concentrations, viz., 0.12, 1 and 8 µg/ml, the recovery of the IS was determined at a single concentration of 5 µg/ml. Validation procedure The method was validated to demonstrate the specificity, linearity, matrix effect, accuracy, precision and (Guideline For Industry, FDA) (9). The specificity of the method was evaluated by analyzing blank human plasma samples collected from six different rats to investigate the potential interferences in the liquid chromatographic peak region for the analyte and IS using the proposed extraction procedure and chromatographic conditions. Linearity was tested at six concentration levels covering a range of 0.12-8 µg / ml. The calibration curve was obtained by plotting the peak area ratio (peak area analyte/peak area IS) versus concentration. The results were fitted to a linear regression analysis y = mx + c, a using weighing factor (1/x 2 ). The acceptance criteria for each back-calculated standard concentration were ± 15% deviation from the nominal value except at the LOQ, which was set at ± 20%. The lower limit of quantitation (LOQ) of the validation was assessed as the lowest concentration on the calibration curve that could be quantitatively determined with acceptable precision and accuracy with in ± 20%. The LOQ was established based on six replicates on five consecutive days. The matrix effect was evaluated in human plasma by comparing the corresponding peak areas of the post extraction spiked samples to those of the standard solutions evaporated directly and reconstituted in mobile phase. Experiments were performed at the three QC levels. If the ratio was less than 85% or more than 115%, the matrix effect was regarded as being of significance. Batches consisting of five calibration standards at each concentration and QC samples were analyzed on five days to complete the method validation. In each batch, QC samples at 0.12, 1 and 8 µg/ml were assayed in sets of five replicates to evaluate the intra- and inter- day precision and accuracy. The

criteria for acceptability of the data included accuracy (% bias) and precision which must be within ± 15% of the nominal value and ± 20% at the LOQ. The accuracy was expressed as % bias: % Bias = (observed conc. nominal conc.) 100/ nominal conc. fortnight. On day 15, cells were fixed in 10% formalin followed by staining with alizarin red stain (40 mmol/l) 10 min washed 5 times with distilled water. Images were taken under inverted microscope (Nikon, ECLIPSE Ti-Series). Cells were appeared bright orange-red due to formation of alizarin red S-calcium complex which is then solubilised using 10% cetylpyridinium chloride in 10 mmol/l sodium phosphate for 30 min. The absorbance was read at 610 nm in a multi-well ELISA plate reader to determine the concentration of released alizarin red stain. All studies were carried out at 0.12 and 8 µg/ml in five replicates. The freeze-thaw was determined after three freeze-thaw cycles (room temperature to -70 ± 10ºC). The post extracted auto-sampler of chlorzoxazone was examined at 4ºC for 72 h. The bench-top of chlorzoxazone in biomatrix was evaluated at ambient temperature (25 ± 5ºC) for 24 h. The long-term freezer was determined at -80 ± 10º C over 30 days. The method was validated in compliance with FDA guidelines, in terms of specificity, Selectivity, linearity, precision, accuracy, limit of quantification, limit of detection, robustness and other aspects of analytical validation. Application of the method Chlorzoxazone plasma protein binding in human plasma was performed at three different concentrations (1.25 and 40 ng/ml). The bound and unbound fractions of chlorzoxazone were separated from human plasma samples by ultra-filtration through the centrifuge micro partition system (Amicon, Centrifree device Inc., MA, USA) (10). Samples in duplicates (0.5 ml) were placed in Centrifree devices and centrifuged at 1500g for 10 min to collect approximate 10% (100 ml) of the original volume of plasma as ultrafiltrate. Non-specific binding of chlorzoxazone was determined by spiking test concentration into 0.01 M phosphate buffer (ph 7.4) and applied same procedure as plasma. The in-vitro samples and their respective ultra-filtrates were analyzed by HPLC. The non-specific binding and plasma protein binding were determined using the following equations: Non-specific binding (%) = 100-[(conc. in buffer ultrafiltrate) 100/conc. in buffer] Plasma protein binding (%) =100-[(conc. in plasma ultrafiltrate) 100/conc. in plasma]. on reversed-phase liquid chromatographic columns. The chromatographic conditions were optimized with respect to specificity, resolution, and time of analysis. Hence we started the development activity with C 18 stationary phase of various manufacturers such as Zorbax, ODS (250 4.6 mm, 5 µm), Spherisorb ODS (250 4.6 mm, 5 µm) Symmetry shield C 18 (250 mm 4.6 mm, 5.0 μ), Phenomenex Luna C 18 (250 4.6 mm, 5 µm), Spheri-5, CYANO column (30 4.6 mm, 5 µm ) and Thermo (250 4.6 mm, 5 µm) column. The last two columns were found to be suitable. However, Thermo (250 4.6 mm, 5 µm) column was used as a good resolution and minimum elution time were obtained. The stationary phase was not only the parameter which could give better resolution. Mobile phase, ph and organic modifies also played very important role which leads the best separation. Different mobile phases containing acetonitrile, methanol, water and buffer were examined. Initially the methanol was used as an organic modifier which gives the poor baseline with baseline drift. Hence the response for the chlorzoxazone was reduced. To improve the resolution and response, acetonitrile was tried as an organic modifier. The base line was found good and response chlorzoxazone was improved. Effects of ph (3-7) and ionic strength (5-50 mm) were investigated using phosphate and acetate buffer. It was found that at higher and lower ph the tailing of the chlorzoxazone peak was more and also resolution was poor of the analyte. The effect of buffer concentration on the retention of chlorzoxazone was also studied. The mobile phase containing acetonitrile: TDW in gradients manner was selected as optimal for obtaining well-resolved peaks with acceptable system suitability parameters. Flow rates from 0.5 to 1.5 ml min - 1 were tested. Flow rates less than 0.5 ml/min led to an increase in retention times peak broadening and the time of analysis. High flow rates led to a remarkable increase in column pressure and decrease in resolution. It was found that 1 ml min -1 was optimal as it compromised between resolution and run time. Effect of the wavelength on the response factor was observed over the wavelength range 200-500. The detection wavelength, 279 nm was found optimal due to the high absorbtivity at this wavelength for rifampicin (Fig 2). Complete separation was achieved in < 14 min at ambient temperature (Fig 2). RESULT AND DISCUSSION HPLC method development Analysis of chlorzoxazone is a challenge owing to its high polarity and small molecular size, which lead to poor retention Fig.2 Representative Overlay chromatogram of analyte and IS after extraction of CS in human plasma

Sample extraction and recovery The blank plasma was used as a surrogate matrix organic solvent precipitation using acidified acetonitrile or methanol and DMSO in methanol resulted in non-reproducible recoveries and interferences from the sample matrix with the chromatography of Table 1 Intra-day and inter-day assay precision and accuracy for chlorzoxazone Accuracy (%Bias) Precision (%RSD) Concentration Intra-day Inter-day Intra-day Inter-day (µg/ml) 0.12 6.4 6.5 5.18 5.9 1-3.9-4.2 4.19 4.6 8 2.85 3.12 3.034 2.63 Table 2 Stability of chlorzoxazone in human plasma Nominal Conc. Stability Mean S.D. 0.12 µg/ml 8 µg/ml Auto sampler Bench-top Freeze-Thaw Long-term Auto sampler Bench-top Freeze-Thaw Long-term the analytes (data not shown). Liquid liquid extraction was not a feasible option due to extraction of endogenous product in human plasma, they produced significant matrix effect. Solid phase extraction (SPE) was investigated using Oasis HLB, CN and C18 cartridges for optimizing the extraction procedure. But SPE method was more expensive and not reproducible. Finally, protein precipitation for chlorzoxazonea and IS extraction was investigated using ACN. This resulted in considerable improvement in recovery of both analyte and IS. The absolute mean recovery of chlorzoxazone and IS were 90.0% and 70.35% respectively. The % CV values are within the acceptable limits (<10%) table (3) and (4). Validation procedures Precision (%RSD) Accuracy (%bias) 0.11 0.04 0.45 0.99 0.12 0.06 1.77-5.32 0.12 0.08 1.43-0.58 1.20 0.14 1.07 5.1 8.41 0.56 2.12-0.68 8.64 8.32 8.99 0.45 2.32-5.34 0.32 3.09-0.6 0.19 1.98 3.49 Selectivity and specificity Six lots of blank human plasma were analyzed for the evaluation of selectivity and specificity. These samples did not show any significant interfering peaks at the retention times of either chlorzoxazone the IS (Fig 2). Matrix effect The adverse consequences of matrix effects on the results of quantitative HPLC analyses have been fully recognized and the assessment of matrix effects is becoming an integral part of method development and validation. The matrix effect for chlorzoxazone at 0.12 and 8 µg/ ml concentration levels in human plasma was < ± 2%. Thus no significant matrix effect was observed. Table 3 Recovery of Chlorzoxazone in human plasma Concentration (µg/ml) %Recovery %CV 0.12 91 ± 4.2 4.2 Calibration curves 1 86 ± 4.35 3.8 8 87.42 ± 4.94 3.5 The peak area ratio of analyte to IS was linear over a concentration range of 0.1.2-8 µg/ml for chlorzoxazone. The calibration curve had a reliable reproducibility over the concentration range 0.12-8 µg/ml. The average regression (n=3) was found to be 0.998 ± 0.0017. The lowest concentration with RSD < ± 20% was taken as the LOQ and this was found to be 0.12 µg/ml. Accuracy and precision Intra- and inter-assay precision was determined from the relative standard deviations (% RSD) of the quality control samples ( LQC, MQC, and HQC). The intra-day assay precision and intraassay accuracy were within the limits and ranges from 3.03% to 1.18 % and 2.85 to 6.4% respectively (Table 1). The inter-day assay precision and accuracy ranged from 2.85 to 6.4% and 3.12 % to 6.5%, respectively. Both intra and inter-day precision and accuracy were found to be within the accepted variable limits. Table 4 Bound and unbound chlorzoxazone in protein binding study No of Freeze % Unbound %Bound %Recovery Thaw cycle Fresh Human Plasma 2.66±0.057 97.33±0.057 79.49±6.89 1 st Freeze Thaw 4.73±0.58 95.27±0.58 98.71±1.45 2 nd Freeze Thaw 5.16±0.87 94.84±0.87 100.18±19.14 3 rd Freeze Thaw 7.32±5.43 92.68±5.43 77.04±2.33 4 th Freeze Thaw 10.19±5.28 89.81±5.28 81.17±5.49 5 th Freeze Thaw 10.65±4.36 89.35±0.22 82.97±4.17

Stability The predicted concentrations for chlorzoxazone at 0.12 and 8 µg /ml samples deviated within the nominal concentrations in a battery of tests, viz., auto sampler (24 h), bench-top (6 h), repeated three freeze-thaw cycles and at -70 ± 10 ºC for 30 days (Table 2). The results were found to be within the assay variability limits during the entire process. Application of the method In-vitro plasma protein binding studies The present in-vitro study was carried out to determine the extent of plasma protein binding of chlorzoxazone. Bound and unbound drug from spiked/treated plasma was separated by the ultrafiltration technique. Concentration dependent human plasma protein binding was not observed within the selected concentration range. Non-specific binding of chlorzoxazone was found <5%. PPB of chlorzoxazone was determined at conc. 50µg/mL in human plasma. PPB of chlorzoxazone in fresh human plasma was 99.88±0.015 and after 5 th Freeze-thaw of plasma PPB was found to be 99.02±0.22.(Table-4) CONCLUSION Bio analytical method was developed and validated in human plasma for the model drugs chosen. Effect of multiple freezethaw cycles on the extent of plasma protein binding of drugs determined after every freeze-thaw cycles. No significant difference was observed in the percent bound determined in fresh human plasma and plasma after multiple freeze-thaw cycles In summary, a sensitive, rapid and specific HPLC assay of chlorzoxazone using protein precipitation method was developed and validated. A good linearity was obtained over the concentration range of 0.12-8 µg/ ml. Moreover, the assay demonstrate a high sensitivity with LOQ 0.12 µg/ ml using 200 µl volume of plasma sample and simple protein precipitation for extraction procedure. The method is accurate, precise, reproducible and was applied successfully protein binding study. ACKNOWLEDGEMENTS The authors are thankful to Director NIPER, Uttar Pradesh Lucknow, India, for providing the facility. 3. Peter R, Bocker R, Beaune PH, Iwasaki M, Guengerich FP, Yang CS. Hydroxylation of chlorzoxazone as a specific probe for human liver cytochrome P-450IIE1. Chemical research in toxicology. 1990;3(6):566-73. 4. Pawar UD, Naik AV, Sulebhavikar AV, Datar TA, Mangaonkar K. Simultaneous determination of aceclofenac, paracetamol and chlorzoxazone by HPLC in tablet dose form. Journal of Chemistry. 2009;6(1):289-94. 5. Battu PR. Simultaneous estimation of nimesulide and chlorzoxazone in pharmaceutical formulations by a RP- HPLC method. International Journal of ChemTech Research. 2009;1(2):283-5. 6. Battu PR. Simultaneous estimation of nimesulide and chlorzoxazone in pharmaceutical formulations by a RP- HPLC method. International Journal of ChemTech Research. 2009;1(2):283-5. 7. Sastry CS, Chintalapati R, Sastry BS, Lakshmi CS. Spectrophotometric determination of chlorzoxazone in pure state and formulations through oxidative coupling of its hydrolysis product. 2000. 8. Bhatta RS, Kumar D, Chhonker YS, Saxena AK, Jain GK. Bioanalytical method development and validation of novel antithrombotic agent S002-333 by LC-MS/MS and its application to pharmacokinetic studies. Biomedical chromatography : BMC. 2010;24(11):1234-9. 9. Food, Administration D. Guidance for industry: bioanalytical method validation (2001). Maryland, USA. 2007. 10. Chhonker YS, Kumar D, Shrivastava P, Kumar D, Singh R, Chandasana H, et al. LC MS/MS assay for the determination of natamycin in rabbit and human plasma: Application to a pharmacokinetics and protein binding study. Journal of Pharmaceutical Analysis. 2013;3(2):144-8. REFERENCES 1. Desiraju RK, Renzi NL, Jr., Nayak RK, Ng KT. Pharmacokinetics of chlorzoxazone in humans. Journal of pharmaceutical sciences. 1983;72(9):991-4. 2. Eap CB, Schnyder C, Savary L. Determination of chlorzoxazone and 6-hydroxychlorzoxazone in plasma by gas chromatography--mass spectrometry. Journal of chromatography B, Biomedical sciences and applications. 1998;705(1):139-44.