Effect of occlusal splint thickness on electrical masticatory muscle activity during rest and clenching

Similar documents
Reestablishment of Occlusion with Prosthesis and Composite Resin Restorations

Articulators. 5- Wax up and refining the occlusion for dental restorations.

BUCCAL MUCOSA RIDGING AND TONGUE INDENTATION: INCIDENCE AND ASSOCIATED FACTORS

To Determine the Influence of the Complete Denture Prosthesis on Masticatory Muscle Activity in Elderly Patients: An in vivo Study

Jaw relation registration in RPD

OCCLUSION: PHYSIOLOGIC vs. NON-PHYSIOLOGIC

Neuromuscular Dentistry: Transcutaneous Electrical Nerve Stimulation and Orthotic Solutions in Full Mouth Reconstruction

MDJ Stabilization Splint (Night Guard, Mouth Guard) Vol.:6 No.:2 2009

TEMPOROMANDIBULAR JOINT DISORDER: ROLE OF BILATERAL BALANCED AND CANINE GUIDANCE OCCLUSAL SPLINTS: A CLINICAL STUDY

MUSCLE ACTIVITY AFTER REPOSITIONING

Principle of Occlusion

Prosthodontics. Dental articulator. 1-Allow most of the prosthetic work to be done in the absence of the patient.

Prosthetic Management of TMJ Disorders

Horizontal jaw relations: The relationship of mandible to maxilla in a

The effect of a Lucia jig for 30 minutes on neuromuscular re-programming, in normal subjects

529-A Treatment and Management of the Edentulous Patient. Upon completion of this course the student should be able to:

Methods of determining vertical dimension of occlusion

Case Report Use of Zirconia to Restore Severely Worn Dentition: A Case Report

The effect of occlusal splint treatment on the temporomandibular joint dysfunction patient

Restoration of Smile And Function in Partially Edentulous Patient With worn out Anterior Dentition

Surface electromyography of jaw muscles and kinesiographic recordings: diagnostic accuracy for myofascial pain

Do pianists play with their Teeth?

Case Report Prosthodontic Rehabilitation of the Patient with Severely Worn Dentition: A Case Report

Jaw relations and jaw relation records

Surface Electromyography Findings in Unilateral Myofascial Pain Patients: Comparison of Painful vs Non Painful Sides

Shadeguides Finding the Centric Relation The Kois Deprogrammer

Horizontal Jaw Relation

Review Does altering the occlusal vertical dimension produce temporomandibular disorders? A literature review

Comparisons of Condylar Movements with the Functional Occlusal Clutch and Tray Clutch Recording Methods in CADIAX system

Evaluation of the effect of two different occlusal splints on maximum occlusal force in patients with sleep bruxism: a pilot study

Vertical relation: It is the amount of separation between the maxilla and

Quantitative analysis of occlusal force balance in intercuspal position using the Dental Prescale system in patients with temporomadibular disorders

Dr Mohammed Alfarsi Page 1 9 December Principles of Occlusion

CATCH IT RIGHT -A CASE REPORT ON OCCLUSAL SPLINT

Immediate Effect of Occlusal Errors on Masticatory Muscle Activity in Denture Wearers: A Pilot Study

Initial Doctor Questionnaire

CAD/CAM Dentures. CAD/CAM Dentures. AvaDent Digital Dentures. Disclosure 5/25/15. Summary of Advantages of CAD/CAM Complete Dentures CAD/CAM

Concepts of occlusion Balanced occlusion. Monoplane occlusion. Lingualized occlusion. Figure (10-1)

Deprogrammers made. Deprogrammers can be used for... How do deprogrammers work?

Int J Clin Exp Med 2017;10(11): /ISSN: /IJCEM

TMD Management in 2010: Science or Smoke and Mirrors

JAMSS Speed-to-Treat Protocol For treatment of jaw joint and muscle sprain/strain injuries

The Effect of Different Occlusal Splints on The Electromyographic Activity of Elevator Muscles: A Comparative Study

Ascertaining of temporomandibular disorders (TMD) with clinical and instrumental methods in the group of young adults

Re-evaluation of the Condylar Path as the Reference for Occlusion

Temporomandibular disorders and the need for stomatognathic treatment in orthodontically treated and untreated girls

A Case Report of the Symptom-Relieving Action of an Anterior Flat Plane Bite Plate for Temporomandibular Disorder

Case report: Lingualized occlusion -A better way for enhancing function & esthetic

Case Report Replacement of Missing Anterior Teeth in a Patient with Temporomandibular Disorder

The role of occlusal splints (soft and hard) in the management of Myofascial Pain Dysfunction Syndrome

Full-mouth rehabilitation of a patient with severe attrition using the Hobo twin-stage procedure

Muscles of mastication [part 1]

A CLASSIFICATION SYSTEM FOR THE MANAGEMENT OF BIOMECHANICAL FACTORS IN DENTISTRY

SYSTEMATIC REVIEW AND META-ANALYSIS

Comparative evaluation of clinical performance of different kind of occlusal splint in management of myofascial pain

Tooth preparation for posterior fi xed partial denture (FPD) Tooth preparation for anterior fi xed partial denture (FPD)

Intra-rater reliability of TMJ joint vibration a pilot study

Maximizing Insurance Benefits

A Clinical and Cephalometric Study of the Influence of Mandibular Third Molars on Mandibular Anterior Teeth

Introduction to Occlusion and Mechanics of Mandibular Movement

PATIENTS REFFERED TO SPLINT THERAPY: A SURVEY OF ONE HUNDRED FOURTY TWO PATIENTS

Reduction in parafunctional activity: a potential mechanism for the effectiveness of splint therapy

Vertical Dimension in Restorative Dentistry short seminar

Anterior midline point stop device (AMPS) in the treatment of myogenous TMDs: Comparison with the stabilization splint and control group

Modified Dahl s Appliance: A clinical Report

A Systematic Approach for Rehabilitation of Occlusion in Fixed Partial Denture

Title. CitationApplied Surface Science, 262: Issue Date Doc URL. Type. File Information.

Prosthetic and Surgical Approach for Oral Rehabilitation in a Patient with Amelogenesis Imperfecta: A Clinical Report

Application of ARCUS digma I, II systems for full mouth reconstruction: a case report

ANTERIOR OPEN BITE AS A COMPLICATION OF THE TREATMENT OF BRUXISM WITH ANTERIOR BITE PLANE: A CASE REPORT

Occlusion in complete denture

Dental Research Journal

Journal of American Science, 2012:8(3)

Effect of stabilization splint therapy on pain during chewing in patients suffering from myofascial pain

The Reinforced Removable Retainer

Case Report Reestablishment of Occlusal Vertical Dimension in Complete Denture Wearing in Two Stages

Temporomandibular Joint Disorders

DR. PETER DAWSON S PHILOSOPHY OF FUNCTIONAL OCCLUSION

Full mouth occlusal rehabilitation; by Pankey Mann Schuyler philosophy

Diagnosis. overt Examination. Definitive Examination. History. atient interview. Personal History. Clinical Examination.

Outline. Limiting your risk when treating patients with TMD. Temporomandibular Disorders 20/01/2014. TMD diagnosis. Condylar position and TMD risk

The Journal of Craniomandibular & Sleep Practice. ISSN: (Print) (Online) Journal homepage:

SPLINT THERAPY: WHAT WORKS, WHAT DOESN T AND WHY?

Achieving esthetics and occlusion concepts in a limited restorative space utilizing adhesive prosthodontic approach

Selection and arrangement of teeth in rpd

Occlusion and removable prosthodontics

Restoring Severe Anterior Wear Cases; A Step by step Process

Up Date on TMD WHAT IS TMD? Temporomandibular Disorders (TMD)*: Donald Nixdorf DDS, MS

Electromyographic and patient-reported outcomes of a computer-guided occlusal adjustment performed on patients suffering from chronic myofascial pain

Unique Dental Supply. Catalog We Bring World Quality Products to Enhance your Business QUALITY PRODUCTS SINCE 1974

PATIENT INSTRUCTIONS FOR BRACE REMOVAL

S.A.F.E. Protocol For prevention of jaw joint and muscle sprain/strain injuries during dental treatment

Citation for published version (APA): Koutris, M. (2013). Masticatory muscle pain: Causes, consequences, and diagnosis

Splint Appliance. Selection Guide. Great Lakes. See inside...

LEARN FROM A LEADER. Intensive, hands-on training that will prepare you to confidently fabricate the appliances you want.

REVIEW ARTICLE The Essentials of Occlusal Splint Therapy Sangeeta Yadav, Jyoti T. Karani

(Images are at the end of article)

Experience of Orthodontic Treatment and Symptoms of Temporomandibular Joint in South Korean Adults

A Critical Evaluation of different methods of recording centric jaw relation of completely edentulous individuals - An In Vivo Study *

Anatomy and physiology of Temporomandibular Joint

Transcription:

Occlusion / Temporomandibular Disorder Occlusion Effect of occlusal splint thickness on electrical masticatory muscle activity during rest and clenching Murillo Sucena Pita (a) Adriana Barbosa Ribeiro (a) Alicio Rosalino Garcia (b) Vinicius Pedrazzi (a) Paulo Renato Junqueira Zuim (b) (a) Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirão Preto, University of São Paulo USP, Ribeirão Preto, SP, Brazil. (b) Department of Dental Materials and Prosthodontics, School of Dentistry of Araçatuba, São Paulo State University UNESP, Araçatuba, SP, Brazil. Abstract: The extent of separation between the maxillary and mandibular teeth in the fabrication of interocclusal splints designed to achieve efficiency and muscle relaxation is controversial and undefined in the literature. Based on this premise, the aim of this study was to evaluate the effect of interocclusal splint thicknesses of 3 and 6 millimeters on the electrical activity of the anterior temporal and masseter muscles during rest and dental clenching. Twenty asymptomatic individuals (10 males and 10 females) were selected using the Research Diagnostic Criteria (RDC). Electromyography (EMG) was performed both with and without the 3- and 6-mm splints using the Bio EMG software package, which recorded values given in microvolts (µv). The results, which were assessed using analysis of variance (ANOVA) to a 5% significance level (p < 0.05), showed increased electrical activity of the masticatory muscles during dental clenching compared with at rest, with greater activity in the masseter muscle. The electrical activity did not differ according to the thickness of the splints or between males and females. We can conclude that both splint thicknesses are effective in treating muscle hyperactivity given their similar clinical behavior for asymptomatic individuals. Descriptors: Electromyography; Temporal Muscle; Masseter Muscle; Occlusal Splints; Dental Occlusion. Declaration of Interests: The authors certify that they have no commercial or associative interest that represents a conflict of interest in connection with the manuscript. Corresponding author: Vinícius Pedrazzi E-mail: pedrazzi@forp.usp.br Received for publication on Jun 15, 2011 Accepted for publication on Sep 28, 2011 Introduction Interocclusal appliances are devices designed to reestablish vertical dimension and reduce muscle hyperactivity. They create a temporary occlusal condition that allows the temporomandibular joints (TMJ) to orthopedically adopt a more stable position. 1 They can also be used to provide an ideal occlusal condition to reorganize neuromuscular reflex activity, reducing parafunctional activity while stimulating normal muscle function. The occlusal splint is designed to eliminate any orthopedic instability between the occlusal and articular positions, thereby preventing this instability from causing temporomandibular disorders (TMD). 2 Electromyography (EMG) is defined as a graphic record of the electrical potential of muscles, and has been used to study the behavior of muscles both during static and dynamic functions. 3 The characteristics of the electrical activity of the muscles depend on the length of the muscle fibers, electrode positioning in relation to the muscle fibers, area and 506 Braz Oral Res. 2011 Nov-Dec;25(6):506-11

Pita MS, Ribeiro AB, Garcia AR, Pedrazzi V, Zuim PRJ distance between the electrodes and the thickness of the fat layer between the skin and muscles. 4,5 The muscle parameters frequently studied by EMG include postural position or rest, as well as activity during maximum tooth clenching. Such parameters have been used to evaluate the effect of occlusion on normal muscle function, both with and without an interocclusal splint. They are also used to assess the effect of different interocclusal splints on dysfunctional muscles and to monitor deleterious habits. 3 Only a limited number of studies in the literature 6-9 have attempted to connect these elements in patients with TMD. They have mostly assessed the electromyographic effects of splints with only minimal interocclusal separation, with conflicting results among them. Some studies have reported an increase in muscle electrical activity, while others did not observe changes or any decrease in muscle activity. However, all patients in these studies generally displayed significant improvements. 6-9 The objective of this study was to evaluate the thickness of occlusal splints and the associated electrical activity of the anterior temporal and masseter muscles during rest and dental clenching, as well differences between genders, considering the normal physiological and functional state of the muscles and the asymptomatic condition of the selected individuals. Methodology Selection of individuals Twenty young adults (10 for each gender) with an average age of 22 years old were selected according to the following inclusion criteria, with occlusion considered as normal or physiologic: 10 a. No signs or symptoms of TMD; b. Absence of muscle tenderness; c. Absence of parafunctional activities; d. Female patients currently not in their premenstrual period. Patient selection was made by anamnesis and physical examination using the Research Diagnostic Criteria (RDC), Axis I for standardization and establishment of asymptomatic conditions. All individuals agreed with the rules of the Ethics Committee in Human Research of the School of Dentistry of Araçatuba, São Paulo State University - UNESP (FOA Process 2008-00803). Preparing the occlusal splint After selecting the subjects, models were obtained through diagnostic impressions of the maxillary and mandibular dental arches, resulting in special plaster casts. The maxillary model was mounted employing a face bow on a semi-adjustable articulator; the mandibular model was assembled by juxtaposition. 11 A 3-mm interocclusal separation of the incisal guide pin was recorded. An occlusal splint was made using the distance on the upper jaw model, with a 1.5-mm thickness plate of polyvinyl chloride (PVC). Acrylic resin was added on the occlusal surface of this plate with the models mounted in the articulator. Occlusal adjustments were performed to establish simultaneous contacts in all teeth and to guide the teeth along lateral-protrusion jaw movements. Then, the same procedure was repeated with a separation of 6 mm to fabricate another occlusal splint of greater thickness. As such, two splints were fabricated with 3- or 6-mm distances as shown by the articulator anterior pin. Electromyographic evaluation (EMG) The subjects were instructed not to perform masticatory function and to avoid the use of caffeine within two hours before the test. Prior to the test, the subjects washed their faces with soap and water in the areas corresponding to the muscles to be analyzed; 70% alcohol was used to remove skin oils and enhance the conductivity of the electrical signals. The subjects were comfortably installed in a chair inside a room with a controlled temperature (22 C) for 30 minutes. Bipolar surface electrodes (Kendall MedTrace 100 Conductive Adhesive ECG Electrodes, Tyco Healthcare Group LP, Pointe-Claire, Canada) were placed with a distance of 18 mm between them, following the long axis of the muscle fibers of the masseter and anterior temporal muscle on both sides 4,5 (Figure 1). These electrodes were linked by wires to an amplifier connected to a computer for recording and analysis of muscle activity Braz Oral Res. 2011 Nov-Dec;25(6):506-11 507

Effect of occlusal splint thickness on electrical masticatory muscle activity during rest and clenching splint and 4 th and 5 th records were obtained following the same criteria used for the 2 nd and 3 rd records. The analysis of the EMG recordings in the mandibular rest position was obtained at 1, 3, 5 and 7 seconds, allowing an average of four readings over the 30-second period, measured in microvolts (µv). During teeth clenching, measurements were recorded at 5-second increments over the same 30-second period. Statistical analysis Data from each of the four muscles (left temporal - LT, right temporal - RT, left masseter - LM and right masseter - RM) were assessed using analysis of variance (ANOVA) with a significance level set at p < 0.05. Two variables were used: 1. gender (female and male) and 2. treatment (the different thicknesses of the employed splints). Figure 1 - Arrangement of electrodes placed in the masseter and anterior temporal muscles for EMG. using the Bio EMG (Biopack - Bio-System Research, Inc., Milwaukee, USA) software package. Electrical activity was recorded at five different time points. The first recording occurred during the initial examination before occlusal splint use, at mandibular rest and during teeth clenching, both for 30 seconds (1 st record). After this, the 3-mm occlusal splint was placed in the mouth for another reading (2 nd record). After 24 hours of use, the patients returned for a reassessment of electrical activity; with the occlusal splint properly positioned, records were obtained both at rest and during dental clenching for 30 seconds (3 rd record). A one-week washout time without occlusal splint use was performed before the next test. The patients then returned for delivery of a 6-mm-thick occlusal Results The results are displayed in Figures 2 (at rest) and 3 (during clenching) for the four analyzed muscles. Their respective mean values and standard deviations for EMG are presented below. At rest: RT (F = 2.34 ± 0.05 / M = 2.84 ± 0.16), LT (F = 2.24 ± 0.11 / M = 2.78 ± 0.04), RM (F = 2.44 ± 0.11 / M = 2.66 ± 0.15), LM (F = 2.4 ± 0.12 / M = 2.94 ± 0.11). During dental clenching: RT (F = 62.42 ± 3.60 / M = 49.56 ± 5.28), LT (F = 58.48 ± / M = 45.32 ± 3.34), RM (F = 92.48 ± 9.55 / M = 84.5 ± 8.73), LM (F = 99.3 ± 7.74 / M = 92.18 ± 9.65). The bilaterally measured EMG activity, collected as the sum of the data obtained from the right and left masseter muscles and right and left temporal muscles, is presented in Table 1 (at rest) and Table 2 (during clenching). No statistically significant differences were found between females and males as well as between treatments with different splint thicknesses. Greater activity was also noted in the masseter muscle for both genders. 508 Braz Oral Res. 2011 Nov-Dec;25(6):506-11

Pita MS, Ribeiro AB, Garcia AR, Pedrazzi V, Zuim PRJ Table 1 - Bilateral muscle activity at rest (mean ± sd). EMG (µv) Right Left (R+L) Temporal 5.8 ± 0.35 5.02 ± 0.38 10.2 ± 0.11 NS Masseter 5.1 ± 0.15 5.34 ± 0.38 10.44 ± 0.16 NS T+M 10.28 ± 0.05 10.36 ± 0.22 20.64 ± 0.05 NS NS = non-significant difference. Table 2 - Bilateral muscle activity during dental clenching (mean ± sd). EMG (µv) Right Left (R+L) Temporal 111.98 ± 9.09 103.8 ± 9.3 215.78 ± 5.78 NS Masseter 176.98 ± 5.64 191.48 ± 5.03 368.46 ± 10.25 NS T+M 288.96 ± 45.96 295.28 ± 61.99 584.24 ± 4.46 NS NS = non-significant difference. Figure 2 - EMG records at rest. Figure 3 - EMG records during dental clenching. Braz Oral Res. 2011 Nov-Dec;25(6):506-11 509

Effect of occlusal splint thickness on electrical masticatory muscle activity during rest and clenching Discussion The masseter and anterior temporal muscles are the masticatory muscles that are most frequently studied using EMG given their easy accessibility via surface electrodes. Many studies have obtained recordings and assessed the relationship between these muscles with TMDs. 12 The clinical position of rest is currently characterized as a condition of muscle activity in the stomatognathic system that adapts relatively well to moderate changes in the occlusal vertical dimension (OVD). 13,14 However, some authors have suggested that increasing OVD would be responsible for the appearance of muscle symptoms and that this increase would lead to the worsening, rather than the amelioration, of symptoms. Nevertheless, if this change reaches the freeway space, stimulated neuromuscular spindles may induce dental clenching, resulting in muscle hyperactivity. 15 A study analyzed the influence of increased effectiveness of OVD chewing using anatomical splints with thicknesses of 2, 4 and 6 mm. This study used subjective criteria based only on symptoms reported by the patients, who reported absence of pain, discomfort or tension in the masticatory muscles and no changes in masticatory performance. 16 Similar results were observed in our study, in which an objective analysis was conducted using EMG. We also observed no differences between the tested splint thicknesses (3 and 6 mm). In contrast, Suvinen et al. 17 reported a gradual reduction in the electrical activity of the masseter when the OVD was increased. The difference found between their study and ours can be attributed to the different OVDs that were used. These authors reported an interocclusal separation of approximately 14 mm, while our study utilized a thinner interocclusal separation (the greatest thickness was 6 mm). The effect of voluntary contractions (of both short and long duration) on EMG activity among asymptomatic patients in our study confirmed that some physiologic changes occurred after 20 s and 30 s due to dental clenching. These patients reported an onset of masseter muscle fatigue after 30 s. 18,19 This apparent fatigue depends on contraction time and the level of force exerted during clenching. 20 Muscle fatigue is a risk factor for TMD. The EMG results showed that male subjects have greater resistance to muscle fatigue, suggesting that this gender difference may influence the larger susceptibility of TMD among females. 21 Apart from muscle physiology, sex hormones may be related to the gender difference in the prevalence of TMD. 22 However, our EMG results showed no evidence of difference between genders in the activity of the anterior temporal and masseter muscles during dental clenching, which can be explained by the screening of asymptomatic individuals. They were patients who avoided prolonged exercise and used splints for prolonged periods. Decreased electrical activity of the muscles with occlusal splints during dental clenching may be directly related to the number of occlusal contacts on the splint. 23,24 However, the precise mechanism responsible for the observed changes is still unclear and may be due to correlated factors such as changes in sensory information from peripheral receptors. These receptors that are susceptible to external stimuli are sensitized to TMJ, muscles, and periodontal ligaments, as well as regions of the tongue, lips and oral mucosa. 25 Other characteristics of splints that may reduce symptoms associated with TMD are cognitive awareness and the placebo effect. 2 Conclusion Considering the results observed and within the limitations of our study, we conclude that the electrical activity did not differ between the two different occlusal splint thicknesses that were analyzed or between males and females. Therefore, both occlusal splints may be used in the treatment of muscle hyperactivity considering their similar clinical behavior in asymptomatic individuals. 510 Braz Oral Res. 2011 Nov-Dec;25(6):506-11

Pita MS, Ribeiro AB, Garcia AR, Pedrazzi V, Zuim PRJ References 1. Savabi O, Nejatidanesh F, Khosravi S. Effect of occlusal splints on the electromyographic activities of masseter and temporal muscles during maximum clenching. Quintessence Int. 2007 Feb;38(2):129-32. 2. Okeson JP. A response to the AADR s Managing the care of patients with temporomandibular disorders: a new guideline for care. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2011 Feb;111(2):134-5. 3. Suvinen TI, Kemppainem P. Review of clinical EMG studies related to muscle and occlusal factors in healthy and TMD subjects. J Oral Rehabil. 2007 Sep;34(9):631-44. 4. Castroflorio T, Farina D, Bottin A, Piancino MG, Bracco P, Merletti R. Surface EMG of jaw elevator muscles: effect of electrode location and inter-electrode distance. J Oral Rehabil. 2005 Jun;32(6):411-7. 5. Dimitrova NA, Dimitrov GV, Nikitin AO. Longitudinal variations of characteristics frequencies of skeletal muscle fiber potentials detected by a bipolar electrode or multielectrode. J Med Eng Technol. 2001 Jan-Feb;25(1):34-40. 6. Kawazoe Y, Kotani H, Hamada T, Yamada S. Effect of occlusal splints on the electromyographic activities of masseter muscles during maximum clenching in patients with myofascial pain-dysfunction syndrome. J Prosthet Dent. 1980 May;43(5):578-80. 7. Dahlström L, Haraldson T, Janson ST. Comparative electromyographic study of bite plates and stabilization splints. Scand J Dent Res. 1985 Jun;93(3):262-8. 8. Visser A, McCarroll RS, Naeiji M. Masticatory muscle activity in different jaw relations during submaximal clenching efforts. J Dent Res. 1992 Feb;71(2):372-9. 9. Fitins D, Sheikoleslam A. Effect of canine guidance of maxillary occlusal splint on level of activation of masticatory muscles. Swed Dent J. 1993;17(6):235-41. 10. Gonzalez YM, Greene CS, Mohl ND. Technological devices in the diagnosis of temporomandibular disorders. Oral Maxillofac Surg Clin North Am. 2008 May;20(2):211-20. 11. Hamata MM, Zuim PRJ, Garcia AR. Comparative evaluation of the efficacy of occlusal splints fabricated in centric relation or maximum intercuspation in temporomandibular disorders patients. J Appl Oral Sci. 2009 Jan-Feb;17(1):32-8. 12. Dawson PE. Evidence-based versus experience-based views on occlusion and TMD. Am J Orthod Dentofacial Orthop. 2005 Aug;128(2):150-1; author reply 151-2. 13. Yabushita T, Zeredo JL, Toda K, Soma K. Role of occlusal vertical dimension in spindle function. J Dent Res. 2005 Mar;84(3):245-9. 14. Yabushita T, Zeredo JL, Fujita K, Toda K, Soma K. Functional adaptability of jaw-muscle spindles after bite-raising. J Dent Res. 2006 Sep;85(9):849-53. 15. Choy R, Smith DE. The prevalence of temporomandibular joint disturbances in complete dentures patients. J Oral Rehabil. 1980 Jul;7(4):331-52. 16. Olthoff LW, Van Der Glas W, Van Der Bilt A. Influence of occlusal vertical dimension on the masticatory performance during chewing with maxillary splints. J Oral Rehabil. 2007 Aug;34(8):560-5. 17. Suvinen TI, Reade PC, Könönen M, Kemppainen P. Vertical jaw separation and masseter muscle electromyographic activity: a comparative study between asymptomatic controls and patients with temporomandibular pain and dysfunction. J Oral Rehabil. 2003 Aug;30(8):765-72. 18. Christensen LV. Effects of an occlusal splint on integrated electromyography of masseter muscle in experimental tooth clenching in man. J Oral Rehabil. 1980 Jul;7(4):281-8. 19. Christensen LV, Mohamed SE. Contractile activity of the masseter muscle in experimental clenching and grinding of the teeth in man. J Oral Rehabil. 1984 Mar;11(2):191-9. 20. Buzinelli RV, Berzin F. Electromyographic analysis of fatigue in temporalis e masseter muscles during continuous chewing. J Oral Rehabil. 2001 Dec;28(12):1165-7. 21. Ueda HM, Kato M, Saifuddin M, Tabe H, Yamaguchi K, Tanne K. Differences in the fatigue of masticatory and neck muscles between male and female. J Oral Rehabil. 2002 Jun;29(6):575-82. 22. LeResche L, Saunders K, Von Korff MR, Barlow W, Dworkin SF. Use of exogenous hormones and risk of temporomandibular disorder pain. Pain. 1997 Jan;69(1-2): 153-60. 23. Wood WW, Tobias DL. EMG response to alteration of tooth contacts on occlusal splints during maximal clenching. J Prosthet Dent. 1984 Mar;51(3):394-6. 24. Okeson JP, de Leeuw R. Differential diagnosis of temporomandibular disorders and other orofacial pain disorders. Dent Clin North Am. 2011 Jan;55(1):105-20. 25. Roark AL, Glaros AG, O Mahony M. Effects of interocclusal appliances on EMG activity during parafunctional tooth contacts. J Oral Rehabil. 2003 Jun;30(6):573-7. Braz Oral Res. 2011 Nov-Dec;25(6):506-11 511