AFRRI CHRONIC CAROTID AND JUGULAR CATHETERIZATION IN RHESUS MONKEYS TECHNICAL NOTE AFRRI TN73-2 FEBRUARY J. M. Fein

Similar documents
Home Health Foundation, Inc. To create more permanent IV access for patients undergoing long term IV therapy.

AFRRI SCIENTIFIC REPORT. HEMOPOIETIC STEM CELL MIGRATION IN MICE OF GENOTYPE Sl/Sld FOLLOWING A SINGLE INJECTION OF BORDETELLA PERTUSSIS VACCINE

Technical Tips for Safe, Effective TCAR with the ENROUTE System (Silk Road Medical): When is the Procedure Contraindicated

ompanionport Speciality Medical Devices For The Veterinary Community Surgical Suggestions

AFRRI SCIENTIFIC REPORT THE EFFECTS OF TRAUMATIC INJURY ON SPINAL CORD BLOOD FLOW AFRRI SR74-31 DECEMBER T. F. Doyle A. I. Kobrine A. N.

Per-Q-Cath* PICC Catheters with Excalibur Introducer* System

Document No. BMB/IFU/40 Rev No. & Date 00 & 15/11/2017 Issue No & Date 01 & 15/11/2017

Procedures/Risks:central venous catheter

AFRRI CISTERNOGRAMS IN THE PRIMATE MACACA MULATTA SCIENTIFIC REPORT AFRRI SR73-21 NOVEMBER W. J. Flor J. S. Stevenson N. Ghaed A. E. James, Jr.

RELATIONSHIP BETWEEN HIPPOCAMPAL THETA ACTIVITY AND RUNNING SPEED IN THE RAT. W. L. McFarland H. Teitelbaum E. K. Hedges

RadRx Your Prescription for Accurate Coding & Reimbursement Copyright All Rights Reserved.

BP and Heart Rate by Telemetry

PEMSS PROTOCOLS INVASIVE PROCEDURES

Cardiac Output Technique For Small Animals

Victoria Chapman BS, RN, HP (ASCP)

Groshong* PICC and Catheters

Aus Artificial Uretheral Sphincter Port System

1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER

TRACHEOSTOMY. Tracheostomy means creation an artificial opening in the trachea with tracheostomy tube insertion

2018 HEMODIALYSIS CATHETERS CODING AND REIMBURSEMENT GUIDE

Vascu-PICC WITH CUFF PERIPHERALLY INSERTED CENTRAL VEIN ACCESS CATHETER INSTRUCTIONS FOR USE

Disclosure. Tunneled Catheters: How to Get Unstuck. ASDIN 10th Annual Scientific Meeting Final. Thomas Vesely, M.D.

Vascular access device selection & placement. Alisa Seangleulur, MD Anesthesiology Department, Faculty of Medicine, Thammasat University

Overview of CVADs. Type of device commonly used. Dwell time Flushing requirement Associated complications. lumens

Ancillary Components with Z-Trak Introduction System

Port Design. Page 1. Port Placement, Removal, and Management. Selecting a Vascular Access Device. Thomas M. Vesely, MD

Petite Wound Drainage System. 13mm CWV Drainage System. CWSump. CWV with Trocar

Over the Wire Technique vs. Modified Seldinger Technique in Insertion of PICC

A Primer on Central Venous Access: Peripherally-Inserted Central Catheters, Tunneled Catheters, and Subcutaneous Ports

2. Need for serial arterial blood gas determinations. 2. Anticipation of the initiation of thrombolytic therapy

RadRx Your Prescription for Accurate Coding & Reimbursement Copyright All Rights Reserved.

Saphenous Vein Autograft Replacement

AFRRI SCIENTIFIC REPORT

Intro: Slide 1. Slide 2. Slide 3. Basic understanding of interventional radiology. Gain knowledge of key terms and phrases

Quality Metrics. Stroke Related Procedure Outcomes

Esophageal Perforation

IV therapy. By: Susan Mberenga, RN, MSN. Copyright 2016, 2013, 2010, 2006, 2002 by Saunders, an imprint of Elsevier Inc.

Peel-Apart Percutaneous Introducer Kits for

Introducing a New Treatment Method for Brain Aneurysms

Mary Lou Garey MSN EMT-P MedFlight of Ohio

Successful IV Starts Revised February 2014

Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully

Cardiva Catalyst III INSTRUCTIONS FOR USE

Arterial Map of the Thorax, Abdomen and Pelvis 2017 Edition

Central Venous Access Devices. Stephanie Cunningham Amy Waters

Aspira* Peritoneal Drainage Catheter

CLARIVEIN INFUSION CATHETER

Case #1. Case #1- Possible codes. Unraveling the -59 modifier. Principles of Interventional. CASE 1: Simple angioplasty

RadRx Your Prescription for Accurate Coding & Reimbursement Copyright All Rights Reserved.

Neuro-Vascular Intervention AAPC Regional Conference Springfield, MA

Veins that are firm to

Central Venous Catheter Insertion: Assisting

Kristin Wise, MD, FHM Division of General Internal Medicine and Geriatrics Hospital Medicine 2013

PARENTERAL NUTRITION: VASCUAR ACCESS DEVICE SELECTION

Drawing Blood From the Llama (Venipuncture)

Integra. Endoscopic Gastrocnemius Release System SURGICAL TECHNIQUE

Cook Medical. Zenith Flex AAA Endovascular Graft with Z-Trak Introduction System Physician Training

RadRx Your Prescription for Accurate Coding & Reimbursement Copyright All Rights Reserved.

Curtiss T. Stinis, M.D., F.A.C.C., F.S.C.A.I. SCRIPPS CLINIC

Malperfusion Syndromes Type B Aortic Dissection with Malperfusion

Usefulness of Coil-assisted Technique in Treating Wide-neck Intracranial Aneurysms: Neck-bridge Procedure Using the Coil Mass as a Support

Spasm of the extracranial internal carotid artery resulting from blunt trauma demonstrated by angiography

SURGICAL PROCEDURE DESCRIPTIONS

Arterial Line Insertion Pre Reading

Peripherally Inserted Central Catheter (PICC) Booklet

Directions For Use. All directions should be read before use

Ultrasound Guided Vascular Access. 7/25/2016

Split-Stream LONG-TERM HEMODIALYSIS INSTRUCTIONS FOR USE

Curraheen, Co. Cork. Guidelines on the Management and Care of Central Venous Access Devices

BICEPTOR Tenodesis System

Children's (Pediatric) PICC Line Placement

PRODUCTS FOR THE DIFFICULT AIRWAY. Courtesy of Cook Critical Care

E S C C R I A L T E A R. One great catheter + maximum barrier insertion. c k. p a. h e. a t. a l. r i t e. A r

Nit-Occlud. Coil System for PDA Closure IMPLANTATION POCKET GUIDE. Rx only CV / B. Braun Interventional Systems Inc.

Intravascular Ultrasound

A telescopic ventriculoatrial shunt that elongates with growth

Appendix E: Overview of Vascular

Instructions for Use. IJ Catheter Ultrasound Model Version 2400 Series

Intravenous Catheter Complications

3. PATIENT POSITIONING & FRACTURE REDUCTION 3 8. DISTAL GUIDED LOCKING FOR PROXIMAL NAIL PROXIMAL LOCKING FOR LONG NAIL 13

DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service

You have a what, inside you?

You have a what, inside you?

Ziyad M. Hijazi, MD, FSCAI, FACC

Sample page. POWER UP YOUR CODING with Optum360, your trusted coding partner for 32 years. Visit optum360coding.com.

CASE REPORT AIR VENT OF VEIN GRAFT IN EXTRACRANIAL-INTRACRANIAL BYPASS SURGERY

Ziyad M. Hijazi, M.D., MPH, FSCAI, FACC

Traumatic A-V A V Fistula

Portacath Insertion. Patient Information Leaflet

2013 Coding Changes. Diagnostic Radiology. Nuclear Medicine

Central Line Care and Management

FLEXIC ATH LTD. Peripherally Inserted. Instructions n For Use.

Conventus CAGE PH Surgical Techniques

All bedside percutaneously placed tracheostomies

Central Venous Line Insertion

External Ref: Andres, D.A., et al. Catheter Pinch-Off Syndrome: Recognition and Management.

This information is intended as an overview only

Groshong Catheters with Introcan Safety Peripheral IV Catheter Introducer

Troubleshooting the Dysfunctional PD Catheter

Biomet Large Cannulated Screw System

Transcription:

AFRRI TECHNICAL NOTE AFRRI TN73-2 FEBRUARY 1973 CHRONIC CAROTID AND JUGULAR CATHETERIZATION IN RHESUS MONKEYS J. M. Fein ARMED FORCES RADIOBIOLOGY RESEARCH INSTITUTE Defense Nuclear Agency Bethesda, Maryland Approved for public release; distribution unlimited

Research was conducted according to the principles enunciated in the "Guide for Laboratory Animal Facilities and Care, " prepared by the National Academy of Sciences - National Research Council,

AFRRI TN73-2 February 1973 CHRONIC CAROTID AND JUGULAR CATHETERIZATION IN RHESUS MONKEYS J. M. FEIN LaWAYtfE/R. STROMBERG Colonel, MC, USA Chairman Neurobiology Department MYRON I. VARON Captain MC USN Director ARMED FORCES RADIOBIOLOGY RESEARCH INSTITUTE Defense Nuclear Agency Bethesda, Maryland Approved for public release; distribution unlimited

TABLE OF CONTENTS Page Abstract iii I. Introduction 1 II. Technique 1 III. Comment 3 References 4

ABSTRACT A simplified technique of chronic catheterization of the common carotid artery and internal jugular vein is described. The advantages of the method are its simplicity and ease of access. The technique was used in studies involving angiography and cerebral blood flow, but can be adapted to various purposes. 111

I. INTRODUCTION The common carotid artery and internal jugular vein are catheterized in experimental studies of cerebral blood flow and metabolism, in the course of cerebral angiography, and in the evaluation of drug effects on the nervous system. For acute studies investigators have employed repeated needle punctures, and percutaneous as well as open catheterization of these vessels. Repeated catheterization of vessels is limited by the hazards of thrombosis and embolism within the punctured vessel. To provide chronic access to larger 1 2 vessels some investigators have devised relatively complex arterial loops or have fashioned arterial catheters with an externalized portion secured to the skin for intermittent sampling or drug administration. ' While these procedures may be suitable for more placid animals they are impractical in active experimental animals such as the rhesus monkey. A technique was therefore devised for implanting catheters which would be suitable for use in long-term studies and which would allow sampling from, as well as injection into, the common carotid artery and internal jugular vein. II. TECHNIQUE Rhesus monkeys are tranquilized with intramuscular Sernylan for the initial implantation. Through a midline cervical incision the trachea is found and the strap muscles are split and retracted laterally. The carotid sheath is then dissected free with blunt instruments and the common carotid artery and

internal jugular vein are isolated and mobilized with umbilical tapes. After common carotid arteriotomy, a 22-gauge Longdwell catheter needle* is introduced into the carotid artery to the bifurcation. A Polaroid x-ray film is then taken to verify the position of the catheter since catheterization of the external carotid artery is undesirable and catheterization of the internal carotid artery will frequently result in vasospasm and occlusion. Improper positioning introduces unnecessary artifacts which can be avoided by proper placement of the catheter tip just proximal to the carotid bifurcation. Cath- eterization of the internal jugular vein is simpler, and the injection of 1 cc of Renografin can be used to verify the position of the catheter tip in the jugular bulb. When proper position of the catheter is confirmed, an obturator and its attached screw cap are securely closed over the catheter. After implanting both the arterial and venous catheters they are secured to the midline strap muscles and subcutaneous tissues with a single #32-gauge wire suture, thereby also obliterating some of the residual dead space. The catheters are then coiled subcutaneously and the hubs are led out to lie below a separate lateral stab wound in the neck which is temporarily closed with a single Michel clip. The midline incision is then sutured with 4-0 black silk and routine wound care is sufficient for healing to occur. Longdwell catheter provided by Becton, Dickinson and Company, Rutherford, New Jersey

Whenever desired the monkeys are immobilized in squeeze cages. Sampling of blood or injection of contrast, radioisotope or drugs is then easily accomplished by simply removing a single Michel clip. IE. COMMENT For chronic studies of the cerebral circulation it is necessary to have a reliable means of intermittently withdrawing blood as well as injecting various agents into the carotid and jugular circulations. In active or aggressive animals this entails the risk of uncontrollable hemorrhage if a catheter becomes displaced. In all instances using the present technique where the arterial catheter tip lodged in the common carotid bulb, the catheters remained patent for up to 15 days without requiring irrigation. We would caution against allowing the catheter tip to lie in the lumen of the internal carotid artery. In this position there probably is functional obstruction of blood flow by the catheter and a high rate of thrombus formation. No complications were observed related to the venous catheter, irrespective of the exact position of the catheter tip. Antibiotics were not used in this series of animals but are recommended for longer term studies.

REFERENCES 1. Bone, J. F., Metcalfe, J. and Parer, J. T. Surgical preparation of a carotid loop in sheep. Am. J. Vet. Res. 23:1113-1116, 1962. 2. Linzell, J. L. Carotid loops. Am. J. Vet. Res. 24:223-224, 1963. 3. Mills, L. J. and Simmons, D. H. An arterial catheter for chronic implantation in dogs. J. Appl. Physiol. 23:285-286, 1967. 4. Snow, H. D., Steckel, R. J. and Collins, J. D. An indwelling silastic cannula for repeated vascular access in experimental animals. Radiology 93:1194-1196, 1969.

UNCLASSIFIED Security Classification DOCUMENT CONTROL DATA -R&D CSecurtfy classification ol title, body oi abstract and indexing annotation must be entered when the overall report is classitied) ORIGINATING ACTIVITY (Corporate author) Armed Forces Radiobiology Research Institute Defense Nuclear Agency Bethesda. Maryland 20014 3- REPORT TITLE 2a. REPORT SECURITY CLASSIFICATION UNCLASSIFIED 2b. GROUP N/A CHRONIC CAROTID AND JUGULAR CATHETERIZATION IN RHESUS MONKEYS 4. DESCRIPTIVE NOTES (Type of report and inclusive dates) 5. AU THOR(S) ffirst name, middle initial, last name) J. M. Fein 6. REPORT DATE February 1973 3a. CONTRACT OR GRANT NO. b. PROJECT NO. NWED QAXM c Task and Subtask C 903 d. Work Unit 06 10. DISTRIBUTION STATEMENT 7a. TOTAL NO. OF PAGES 6 9a. ORIGINATOR'S REPORT NUMBER(S) AFRRI TN73-2 7b. NO. OF REFS 4 9b. OTHER REPORT NO{S) (Any other numbers that may be assigned this report) Approved for public release; distribution unlimited II. SUPPLEMENTARY NOTES 13. ABSTRACT 12. SPONSORING MILITARY ACTIVITY Director Defense Nuclear Agency Washington, D. C. 20305 A simplified technique of chronic catheterization of the common carotid artery and internal jugular vein is described. The advantages of the method are its simplicity and ease of access. The technique was used in studies involving angiography and cerebral blood flow, but can be adapted to various purposes. DD, F N 0 o R v M e 5 1473 UNCLASSIFIED Security Classification

UNCLASSIFIED Security Classification KEY wo RDS UNCLASSIFIED Security Classification