Y Physics Radiation Measurements and Monitoring

Similar documents
RADIATION MONITORING DEVICES R A D I A T I O N P R O T E C T I O N & B I O L O G Y - R H O D E S

RADIATION SAFETY REFRESHER TRAINING FOR AUGUSTA UNIVERSITY USERS OF RADIOACTIVE MATERIAL

Radiologic Units: What You Need to Know

Radiation Safety Bone Densitometer

RADIOACTIVITY & RADIATION CHARACTERISTICS

Radiation Protection Guidance For Hospital Staff

PERSONNEL MONITORING AND DOSIMETRY POLICIES

a. If dosimeters should be issued; b. What type(s) will be used and; c. The frequency that dosimeters will be exchanged

Radiation physics and radiation protection. University of Szeged Department of Nuclear Medicine

8.05 days 138 days 7.60 days 0.22 mr/h at 1.0 meter per millicurie 124,068 curies/gram 2 mm = 0.20 cm = 0.08 in 165 cm = 65.0 in = 5.

RELIANT HOLDINGS LTD AND ITS AFFILIATES Safety Management System. Preparation: Safety Mgr Authority: CEO Issuing Dept: Safety Page: Page 1 of 5

Laboratory Safety 197/405. Types of Radiation 198/405

Chem 481 Lecture Material 3/11/09

Martin Law, PhD, DABSNM, DABMP Physicist ic Radiology/QMH

Disclosures. I am on the Onyx speaker bureau I am a paid consultant to. Boston Scientific CeloNova Cook MDS Nordion Sirtex

3/26/2017. Personal Dosimetry Monitoring and Dose Measurements. Agenda. Dosimetric Terms and Definitions Dose Limits External Dosimetry

Future Needs for Standards in 90 Y Microsphere Therapy. CIRMS 2012 Reed Selwyn, PhD, DABR 24 October 2012

RADIATION SAFETY REFERENCE HANDBOOK

PAGE 1 OF 5 HEALTH, SAFETY & ENVIROMENTAL MANUAL PROCEDURE: S560 Radiation Safety REV /14/2012

University of Maryland Baltimore. Radiation Safety Standard Operating Procedure

Radiation Monitoring Instruments

45 Hr PET Registry Review Course

Ionizing Radiation. Michael J. Vala, CHP. Bristol-Myers Squibb

Radiation Safety for New Medical Physics Graduate Students

Hand Dose in Nuclear Medicine Staff Members

Introduction. Chapter 15 Radiation Protection. Advisory bodies. Regulatory bodies. Main Principles of Radiation Protection

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

Sandy Perle. Radiation Litigation: an Expert Witness Perspective

ARRT Specifications Radiation Exposure & Monitoring

Site Planning and Design of PET/CT Facilities. Melissa C. Martin, M.S., FACR, FAAPM AAPM Annual Meeting, Orlando, FL August 2, 2006

Sandy Perle. Radiation Litigation: an Expert Witness Perspective

Absorbed Dose: The mean energy per unit mass imparted to any matter by any type of ionizing radiation.

Upon successful completion of the course, the student should be competent in the following tasks:

Hazards + uses of emissions; Background radiation

Personal Dosimetry. Radiation Protection Section Department of Medical Physics Colchester Hospital University NHS Foundation Trust

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Adult: > 18 Years ALARA: As low as reasonably achievable ALI:

Sodium Iodide I 131 Solution. Click Here to Continue. Click Here to Return to Table of Contents

Radiation Health Protection Manual

DRAXIMAGE SODIUM IODIDE I 131 SOLUTION USP DIAGNOSTIC. For Oral Use DESCRIPTION

radiation monitoring programs Tailored to your needs

Assessment of radiological hazard and occupational dose to the lens of the eye at the Bruce Power Nuclear Generating Station

Click Here to Continue. Click Here to Return to Table of Contents

Radiation Protection Program Update: The Details. July 2010

Radiation Safety Manual

Absorbed Dose: The mean energy per unit mass imparted to any matter by any type of ionizing radiation.

Inpatient Admission for Radiation Therapy

Cigna Medical Coverage Policy

Medical Physics 4 I3 Radiation in Medicine

Radiopharmaceuticals. Radionuclides in NM. Radionuclides NUCLEAR MEDICINE. Modes of radioactive decays DIAGNOSTIC THERAPY CHEMICAL COMPOUND

Monitoring of iodine-125 and iodine-131 in thyroid of individuals in nuclear medicine centers of North West provinces of Iran

Patient Management Image Selection Radiation Biology, Dosimetry & Protection

in developing institutional policies, procedures, and /or protocols. The Canadian Society of

International Radiation Protection Association EYE DOSE GUIDANCE (and EPRI Workshop) -- SPRING

Part 7: Regulatory Issues and Quality Control. Part 1: Current NRC Regulations Related to Radiation Safety

INSTRUMENTS. Personal alarm dosimeter 120 Survey meters 122 Beta secondary standard 123

Nuclear energy, nuclear technologies, and radiological protection Vocabulary. Part 4: Dosimetry for radiation processing

The College of Dental Surgeons of Saskatchewan Radiation and Imaging Standard

SUMMARY OF PERSONAL DOSIMETRY PRACTICIES IN RCA MEMBER COUNTRIES

Potential Communication Benefits by adoption of SI units in Radiation Safety

DRAXIMAGE SODIUM IODIDE I 131 CAPSULES, USP DIAGNOSTIC. For Oral Use DESCRIPTION

Variation of Occupational Doses among Subspecialties in Diagnostic Radiology. A.N. Al-Haj, C.S. Lagarde, A.M. Lobriguito

Chapter 4 RADIATION MONITORING INSTRUMENTS

Overview of Effective Dose Equivalent (External)

IONIZING RADIATION, HEALTH EFFECTS AND PROTECTIVE MEASURES

Chapter 4: Radiation Monitoring Instruments

QUANTIFICATION OF THE RISK-REFLECTING STOCHASTIC AND DETERMINISTIC RADIATION EFFECTS

Experiences in Neutron Dosimetry

Biological Effects of Ionizing Radiation & Commonly Used Radiation Units

Overview Therapeutic Radiopharmaceuticals in Nuclear Medicine Definition: Characteristics of the Ideal Therapeutic Radiopharmaceutical

Click Here to Continue. Click Here to Return to Table of Contents

2017 Course of the Nordic Association for Clinical Physics on occupational dosimetry in hospitals

RULES AND REGULATIONS

Radiological Fact Sheet: Controlling contamination

Measures taken by the authority. to reduce extremity doses. in nuclear medicine facilities. in Switzerland

PGY-1. Resident Review Session Schedule

Code of Practice for Radiation Protection in Dentistry. Code of Practice For Radiation Protection in Dentistry

Analytical X-Ray Safety Manual

OCCUPATIONAL EXPOSURE IN CANDU NUCLEAR POWER PLANT: INDIVIDUAL DOSIMETRY PROGRAM AT CERNAVODA NPP

Background Radiation in Radiography Departments and Who Wears Thermoluminescent Dosimeter (TLD) Badges

Calibration of 90 Sr+ 90 Y sources used for betatherapy, using a postal kit of thermoluminescent dosimeters

GLUCEPTATE. Technetium Tc 99m Gluceptate Kit DIAGNOSTIC DESCRIPTION

Radiologist Update on the Relative Patient Doses Associated with Diagnostic Imaging Modalities Today

Biological Effects of Ionizing Radiation & Commonly Used Radiation Units

R: March, E D T P A. Kit for the Preparation of Technetium Tc 99m Pentetate Injection. DIAGNOSTIC - For Intravenous Use

Dollars and Sense: Are We Overshielding Imaging Facilities? Part 2

Click Here to Continue. Click Here to Return to Table of Contents

An update: Dealing with radiation as a hazard. WAJ Meintjes MBChB; DOM; FCPHM(SA) Occ Med; MMed (Occ Med)

Individual dosimetry in planned, existing and accidental exposure situations

Introduction. Measurement of Secondary Radiation for Electron and Proton Accelerators. Introduction - Photons. Introduction - Neutrons.

M A A. Kit for the Preparation of Technetium Tc 99m Albumin Aggregated Injection. DIAGNOSTIC - For Intravenous Use

Radiation Safety Guide. Analytical X-Ray Equipment

The Pursuit of Excellence in Radiation Safety. Darrell R. Fisher President, Health Physics Society

Understanding Radiation and Its Effects

The Basics of Radiation Safety

Quiz True/False: Large amounts of radiation to insects will cause them to mutate!

Module Rhodes

UQ X-ray Safety Training Module

A Simple Model for Establishing Exemption Limits

Transcription:

90 Y Physics Radiation Measurements and Monitoring Mack L. Richard, MS, CHP Indiana University Medical Center Phone: (317) 274-0330 Email: mrichar@iupui.edu

What type of measurements are required? Dosage (activity) to be administered to the patient. Pre-treatment radiation levels from dosage. Radiation levels during dosage administration. Contamination surveys of IR staff prior to leaving area. Survey of patient following administration. Post-treatment radiation levels from waste. Contamination survey of IR suite. Contamination survey of patient recovery area.

Dose Calibrator for Dosage Assay Determine calibration factors (settings) Beta emitter dependent on geometry, dose vial construction Optional with unit doses may use activity provided by vendor SIR-Spheres NIST calibrated dose for initial set up Calibration sheet w/ patient dose for periodic check TheraSpheres Request calibration sheet w/ initial patient dose and recheck periodically

Geometry, Geometry, Geometry!!! Out of the box assay: 82.2 mci After shaking vial, subsequent assays over 1 minute: 76.5 mci 77.5 mci 77.8 mci 78.5 mci 80.0 mci 81.0 mci When setting up dose calibrator, be sure to use the same geometry for setup & subsequent assays

Dose Assay Shaken, not stirred

Dosage Assay SIR-Spheres Since dose must be drawn from stock vial, the vial should always be shaken at dose calibrator setup, prior to initial assay, and prior to subsequent assays following drawing of dose to assure uniform geometry. Theraspheres Since this vendor provides a unit dose, the vial should shaken and tapped on a hard surface to free any microspheres trapped around the septum and then allowed to settle at dose calibrator setup subsequent assays.

Types of Instruments for Radiation Measurements Geiger Mueller (GM) survey meter Good for finding contamination Can be used for making comparative measurements Not as good for measuring true exposure rate due to energy dependency Can saturate at high count rates

GM Energy Response

GM Energy Response with Energy Compensation

90 Y Beta Efficiency For contamination monitoring, the beta detection efficiency is determined by the type of GM detector, beta window thickness, & beta particle energy For 90 Y betas, the typical 4π beta efficiencies are: End window GM probe ~10% (detector sees 1 of every 10 beta particles emitted) Pancake GM probe ~30%

Types of Instruments for Radiation Ion chamber Most common use is for measuring exposure rate from gamma or x-ray sources Good for measuring exposure rate from patient following administration Pressurized ion chambers will provide better sensitivity Measurements

Ion Chamber

What Radiation Units to Use? Dosage Traditional Units (US) 1 Curie (Ci) = 37 GBq 1000 millicuries (mci) 1 millicurie (mci) = 37 MBq 0.037 GBq 0.001 Ci Dosage - SI Units 1 Gigabecquerel (GBq) = 0.027 Ci 27 mci 1000 MBq 1 Megabecquerel (MBq) = 0.027 mci 27 microcuries ( Ci) 0.001 GBq Note: 1 Bq = 1 90 Y atom decaying or disintegrating per second (dps) with 90 Y, 1 beta particle is emitted with every disintegration

What Radiation Units to Use? Exposure Rate from Brems Radiation Milliroentgens/hr (mr/hr) This corresponds to a dose equivalent of about 1 millirem/hr to an individual SI unit of dose equivalent is the millisievert (msv) 1 msv = 100 mrem These are the appropriate units to use when measuring brems radiation only

What Radiation Units to Use? Contamination monitoring Appropriate units are counts per minute (cpm); however, if comparative measurements are being performed, other units such as mr/hr can be utilized It should be understood that the units of mr/hr do not reflect either the dose rate or exposure rate from beta radiation Contamination monitoring is usually the all or none principal By knowing the detector efficiency, one can estimate the amount of contamination on a surface Detector efficiency is very geometry dependent

Quantifying Contamination Example: If one detects 100,000 cpm under the window of a pancake probe with a 30% efficiency for 90 Y betas, how much activity is present under the detector window? 100,000 cpm/0.3 counts/disintegration = 333,333 disintegrations/minute = 5556 dps (Bq), or 5.556 kbq, or 0.15 Ci This amount deposited over 1 cm 2 of bare skin will deliver a skin dose equivalent rate of ~1127 mrem/hr

Personnel Monitoring Body badges for monitoring whole body exposures Ring badges for measuring hand exposures very important with sphere treatments

Primary Standards Annual, occupational dose equivalent limits: Total effective dose equivalent (TEDE) from external & internal sources 5,000 mrem Committed dose equivalent (CDE) to extremities, skin, or individual organs - 50,000 mrem Lens dose equivalent (LDE) - 15,000 mrem

Personnel Monitoring Devices Film Badge Optically Stimulated Dosimeter Direct Reading Dosimeter Ring TLD Dosimeter

Whole Body Badge Use When Pb aprons are routinely used, a collar badge may be used to measure head (eye) & neck dose equivalent It is important to avoid reversing the position of the WB and collar badge Special calculations may be employed to determine EDE from multiple badges

Personnel Monitoring 2 badge method 1 badge worn under Pb apron 1 badge worn at collar, outside Pb apron Effective dose equivalent (EDE) calculated: EDE = 1.5B u + 0.04B o Example B u = 20 mrem, B o = 300 mrem EDE = 1.5(20) + 0.04(300) = 42 mrem* *Generally rounded to nearest 10 mrem 21

Personnel Monitoring Must wear badges correctly & return both for proper EDE calculation Previous example Under apron badge not returned assigned EDE = 300 mrem (7.5X calculated EDE!!) Badge positions reversed (e.g., assume both badges receive ~160 mrem) calc EDE ~250 mrem (6.25X calculated EDE!!) Single badge at collar outside Pb apron EDE = 0.18(B o ) Previous example single badge EDE ~50 mrem 22

Ring Badge Use Wear on hand expected to receive the highest dose equivalent (can wear one ring on each hand) Wear with label on the palm side Wear under gloves

Summary of Instrumentation Use 1. Dosage (activity) Dose Calibrator 2. Pre-treatment radiation levels from dosage GM or Ion Chamber 3. Radiation levels during dosage administration GM or Ion Chamber 4. Contamination surveys of IR staff prior to leaving area - GM 5. Survey of patient following administration Ion Chamber or Energy Compensated GM 6. Post-treatment radiation levels from waste for quantification of delivered dosage Same instrument and geometry as item 2. 7. Contamination survey of IR suite - GM 8. Contamination survey of patient recovery area GM 9. Personnel monitoring Whole Body (1 or 2) and Ring Badges

Q1. A dose calibrator typically reads out in what units? a) Counts per minute (cpm) b) Millicuries (mci) c) Disintegrations per minute (dpm) d) milliroentgens per hour (mr/hr)

Q1. A dose calibrator typically reads out in what units? a) Counts per minute (cpm) b) Millicuries (mci) c) Disintegrations per minute (dpm) d) milliroentgens per hour (mr/hr)

Q2. Which instrument generally provides the best measurement of exposure rate from brems radiation? a) An ionization chamber b) A geiger mueller (GM) survey meter c) A dose calibrator d) A whole body personnel monitoring badge

Q2. Which instrument generally provides the best measurement of exposure rate from brems radiation? a) An ionization chamber b) A geiger mueller (GM) survey meter c) A dose calibrator d) A whole body personnel monitoring badge

Q3. The best way to determine the dose equivalent to one s hand during a 90 Y administration is: a) With an ion chamber b) With a GM survey meter c) With a ring badge d) With a dose calibrator

Q3. The best way to determine the dose equivalent to one s hand during a 90 Y administration is: a) With an ion chamber b) With a GM survey meter c) With a ring badge d) With a dose calibrator

Q4. The best instrument to use for measuring contamination on IR staff following a 90 Y administration is: a) A dose calibrator b) An ion chamber c) A whole body personnel dosimeter d) A GM survey meter

Q4. The best instrument to use for measuring contamination on IR staff following a 90 Y administration is: a) A dose calibrator b) An ion chamber c) A whole body personnel dosimeter d) A GM survey meter

Q5. If you wear under apron and collar personnel monitors (badges) & accidentally switch them several times over the time you wear them: a) It won t affect the calculated effective dose equivalent (EDE) b) The calculated EDE will be artificially high c) The calculated EDE will be artificially low d) The badges will be unreadable

Q5. If you wear under apron and collar personnel monitors (badges) & accidentally switch them several times over the time you wear them: a) It won t affect the calculated effective dose equivalent (EDE) b) The calculated EDE will be artificially high c) The calculated EDE will be artificially low d) The badges will be unreadable