TRACE ELEMENTS IN SERUM

Similar documents
TRACE ELEMENTS IN SERUM

TRACE ELEMENTS IN SERUM. Event #3, 2011

TRACE ELEMENTS IN SERUM. Event #2, 2010

TRACE ELEMENTS IN SERUM. Educational Event. Proficiency Test Report. Event #2, 2013

TRACE ELEMENTS IN SERUM

TRACE ELEMENTS IN SERUM

TRACE ELEMENTS IN URINE. Event #1, 2010

Bottom Ash Data Week 38

Bottom Ash Data Week 49

Bottom Ash Data Week 30

Bottom Ash Data Week 8

Bottom Ash Data Week 37

Bottom Ash Data Week 12

of human hair and nails. Part I. Analytical methodology, Sci. Tot. Environ. 2000, 250/1-3,

OFFICIAL METHODS FOR CHEMICAL ELEMENTS IN FOOD OF ANIMAL ORIGIN

Bottom Ash Data Week 9

Bottom Ash Data Week 17

Multi Analyte Custom Grade Solution

Bottom Ash Data Week 40

STANDARD METHODS FOR CHEMICAL ELEMENTS IN FOOD OF ANIMAL ORIGIN

Bottom Ash Data Week 1

Product Stewardship Information Sheet CH350LN

Analyte Proficiency From All Labs # Analytes: 26 Sample # Statistical Summary # Labs Reporting: 82 Urea Issue Date : 06/30/2016

AAFCO Check Sample 2015 Minerals Program. A Targeted and Engineered Concentration Program

Product Stewardship Information Sheet CH200LN-02

DETERMINATION OF TRACE ELEMENTS IN WATERS AND WASTES BY INDUCTIVELY COUPLED PLASMA - MASS SPECTROMETRY EPA Method (Revision 5.

CERTIFICATE OF ANALYSIS. tel: fax:

Test Report No.T JP Date: FEB 22, 2017 Page 1 of 6

Test Report No.T JP Date: FEB 24, 2017 Page 1 of 6

TOXIC AND ESSENTIAL ELEMENTS

Actual Excipient Test Data on Metal Impurities Submitted to IPEC-Americas from Industry

Landolt-Börnstein: Numerical Data and Functional Relationships in Science and Technology - New Series 12A. Ac-ag...Au-Zr. Bearbeitet von B Predel

MULTI-COMPONENT ANALYSIS OF HEAVY METALS

Test Report No.T TC Date: JUN 29, 2018 Page 1 of 5

Matrix Reference Materials - SCP SCIENCE

Routine Analysis of Fortified Foods using the Agilent 7800 ICP-MS

!!"#$%&'!())*+,$-.&(.*/*+,)0&1-$2

Toxicology Blood Lead Comprehensive Testing

Toxicology Blood Lead Comprehensive Testing

!!"#$%&'!())*+,$-.&(.*/*+,)0&1-$2

Trace Elements in Manure

CERTIFICATE OF ANALYSIS

Matrix Interferences in ICP-MS: Causes, Effects, and Strategies to Reduce or Eliminate Them

Test Report No.: GZHL IP Date: Sep 01, 2016 Page 1 of 12

Test Report No.: T TY Date: DEC 19, 2018 Page 1 of 10

Test Report No.: T TY Date: DEC 19, 2018 Page 1 of 12

Wolf Creek Community Alliance 2009 Soil Sampling Report By BJ Schmitt January 26, 2010

Figure 1. Location of 43 benchmark sites across Alberta.

WAGENINGEN EVALUATING PROGRAMS FOR ANALYTICAL LABORATORIES. Certificate of Analysis. International Plant-Analytical Exchange REFERENCE MATERIAL

TEST REPORT Job No./Report No TR RV1 Date: 25 June 2015 Page 1 of 10

WAGENINGEN EVALUATING PROGRAMS FOR ANALYTICAL LABORATORIES. Certificate of Analysis. International Soil-Analytical Exchange REFERENCE MATERIAL

Edward V. Krizhanovsky, Ph.D., Kamila B. Tursunova

POTENTIALLY g Head Brown Dye Normal V010.08

CERTIFICATE OF COMPLIANCE SGS United Kingdom A UKAS Accredited Test House

HAIR ELEMENTS. PATIENT: Number 74 SEX: Female AGE: 49. POTENTIALLY TOXIC ELEMENTS TOXIC RESULT REFERENCE PERCENTILE ELEMENTS µg/g RANGE 68 th 95 th

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

HAIR ELEMENTS. DOCTOR S DATA, INC. ADDRESS: 3755 Illinois Avenue, St. Charles, IL CLIA ID NO: 14D MEDICARE PROVIDER NO:

TEST REPORT Job No./Report No TR Date:24 June 2015 Page 1 of 14

Nature Protocols: doi: /nprot Supplementary Figure 1

Applicant Name: GD Sigelei Electroinc Tech Co., Ltd B7 Building, No.1 District, Xicheng Science and Technology Park, Hengli Town, Dongguan, China

Micro Trace Minerals Laboratory

Toxicology Blood Lead Comprehensive Testing

!!"#$%&'!())*+,$-.&(.*/*+,)0&1-$2

HAIR ELEMENTS. LAB#: H PATIENT: Franklin C. Cook ID: COOK-F SEX: Male AGE: 66

Chinese Zinc Sulfate Monohydrate testing. Dick Camp Kronos Micronutrients

SAMPLE TEST Toxic Elements Analysis P P P Detection of Amines Derived From Azocolourants and Azodyes NA P P

NUTRIENT AND HEAVY METAL CONTENTS OF HOG MANURE - EFFECT ON SOIL QUALITY AND PRODUCTIVITY

TEST REPORT. LAB LOCATION:TURKEY LAB NO. : (7216) SERVICE TYPE: Regular DATE IN: November 29 th, 2016 DATE OUT: December 01 th, 2016

AAP Lead Testing Webinar Series

PT-2017-NRL-TE-FASFC Determination of As, Asi, Cd, Pb, Cu and Zn in chocolate

Materials Declaration Form

Application Note novaa 800 D. Determination of Macro and Trace Minerals as well as Toxic Trace Metals in Powdered Milk. Challenge.

Greg Patterson C.C.A. President A&L Canada Laboratories

Element concentrations in livers and kidneys of ranch mink

Test Report. No. SHATY Date: 21 Mar Page 1 of 6.

water & dialysate testing services

Analyses no.: Telephone: Fax: Telephone: Fax:

Linear sweep voltammetry as a technique to characterize mining wastes

Ca Mg Na K Cu Zn P Fe Mn Cr Se B Co Mo S Sb U As Be Hg Cd Pb Al

Test Report. No. NGBHG Date: 20 Jun Page 1 of 6.

HAIR ELEMENTS. COMMENTS: results checked

Materials Declaration Form

Analysis of Milk for Major and Trace Elements by ICP-MS

SECTIOn 3. Multi-Element ClP Standards for ICP & ICP-MS

Kelp and Dairy Cattle - a Pilot Study

!!"#$%&'&())*+,$-.&(.*/*+,)0&12".*&3.""4

LAB LOCATION: HONG KONG ISSUE DATE: JUN 05, 2017 REPORT NUMBER: PAGE:

Alkosel /Selsaf D08/FSQ/CVH/GS/(2006) D 421

Magruder Check Sample: 2016 Year End Summary

232 ELEMENTAL IMPURITIES LIMITS

by Oguguah, N. M. and Olakolu, F. C. Marine Biology section, Fisheries Resources Department, Nigerian Institute for Oceanography and Marine Research

AOAC Metals Subgroup. Chemical Contaminants and Residues in Food Community

ESSENTIAL TRACE ELEMENTS PREPARED BY B.KIRUTHIGA LECTURER DEPT OF PHARMACEUTICAL CHEMISTRY

USER SPECIFICATIONS FOR QUINTOLUBRIC 888 Series DESCRIPTION OF THE MOST IMPORTANT PROPERTIES AND THE POSSIBLE VARIATIONS AND TOLERANCES

Appendix D: Aerobic and Anaerobic Leaching Tests

SAMPLE. Control of Preanalytical Variation in Trace Element Determinations; Approved Guideline

Simultaneous Determination of Copper, Zinc and Selenium in Chicken Liver by Differential Pulse Polarography

Transcription:

TRACE ELEMENTS IN SERUM Proficiency Test Report Event #, 0 March th, 0

Event #, 0 Serum Aluminum The test materials for serum Al were prepared from human serum obtained from Tennessee Blood Services, Inc. The units were tested by FDA approved methods and found to be Non-reactive for Anti-HIV-/, Anti-HCV.0 and HBsAg. The serum has also been found to be STS (RPR) Non-reactive and Negative for HIV- and HCV by PCR. Serum units were dispensed into acid-washed 500-mL polypropylene containers to make up five (5) serum pools. Each pool was spiked with a suite of additional trace elements including aluminum as Al + at various concentrations. The Target Value assigned for each PT material is the robust mean of the results reported by all participants in this event. The robust statistics were obtained utilizing algorithms based on those presented in ISO 58:005E Statistical methods for use in proficiency testing by interlaboratory comparisons. Values for serum aluminum range from µg/l (0.5 µmol/l) to 60 µg/l (. µmol/l). Acceptable ranges for serum aluminum are based on fixed criteria of ±0%, or ±5 µg/l below 5 µg/l. These criteria are based on consensus recommendations from several EQAS organizers (). Discussion. Based on the above criteria, 9.6% of test results reported were judged as satisfactory, with three out of participant laboratories (.6%) reporting or more of the 5 results outside the acceptable ranges.. Taylor, A., Angerer, J., Claeys, F., Kristiansen, J., Mazarrasa, O., Menditto, A., Patriarca, M., Pineau, A., Schoeters, I., Sykes, C., Valkonen, S. and Weykamp, C. Comparison of procedures for evaluating laboratory performance in external quality assessment schemes for lead in blood and aluminum in serum demonstrates the need for common quality specifications. Clinical Chemistry 00 8 000-007. Trace Elements PT Program www.wadsworth.org/testing/lead/index.htm

Serum Aluminum Test Results, 0 Event # ROBUST STATISTICAL SUMMARY TARGET VALUE ASSIGNMENT AND STATISTICS Results (µg/l serum) SE-6 SE-7 SE-8 SE-9 SE-0 Robust Mean 5 60 5 Robust Standard Deviation 5 Standard Uncertainty. 0.5 0.7..0 RSD (%) 9..5 0.5 7.5 7. Number of Sample Measurements Acceptable Range: Upper Limit 6 9 9 7 65 Lower Limit 9 9 8 notes: Results reported as less than the method detection limit are excluded from statistical calculations.

Serum Aluminum Test Results, 0 Event # PERFORMANCE OF PARTICIPATING LABORATORIES Lab Code Method SE-6 Results (µg/l serum) SE-7 SE-8 SE-9 SE-0 Info Only Target Values: 5 60 5 0 ETAAS-Z 58 7 8 66 59 7 FAAS 59 6 9 65 59 Info 56 ICP-MS 9 57 5 60 ICP-MS 5 5 57 50 6 ICP-MS 50 60 5 79 DRC/CC-ICP-MS 57 6 65 59 97 ICP-MS <0 5 8 00 DRC/CC-ICP-MS 5 9 9 7 Info 06 DRC/CC-ICP-MS 57 6 6 56 87 ETAAS-Z 5 6 6 55 9 ICP-MS 56 9 6 6 5 Info 05 ICP-MS 56 6 57 HR-ICP-MS 8 0 0 0 Info 5 ETAAS-Z 5 5 8 6 58 Info 55 ICP-MS 5 5 6 55 57 ICP-MS 5 6 55 58 ICP-MS 5 6 6 57 5 6 ICP-MS 50 58 5 6 ICP-MS 55 6 6 59 66 ETAAS-Z 8 0 0 58 56 Info 0 ICP-AES/OES 5 57 9 Info 58 ETAAS Other 9 5 59 56 Percent satisfactory results for all participants: 9.6 % notes: reported outside upper limit Info only: results included for informational purposes only. reported outside lower limit notes: Results reported as less than the method detection limit are excluded from statistical calculations.

DRC/CC-ICP-MS New York State Department of Health Serum Aluminum Test Results, 0 Event # STATISTICAL SUMMARY BY METHOD ETAAS Other ETAAS-Z FAAS HR-ICP-MS ICP-AES/OES ICP-MS All Laboratories Results (µg/l serum) SE-6 SE-7 SE-8 SE-9 SE-0 5 7 9 5 7.7 59 8 5 5 6.8 5 5 9.7.0 6 0 0.6.9 5 6.8 9 0 7.5 5. 59 0 59 6 5.5 65 57 59 5. 59 6 9. 5 9 56 57. 59 0 9 5 5.7 5 5 9. notes: Insufficient data for calculation.

Event #, 0 Serum Copper The test materials for serum Cu were prepared from human serum obtained from Tennessee Blood Services, Inc. The units were tested by FDA approved methods and found to be Non-reactive for Anti-HIV-/, Anti-HCV.0 and HBsAg. The serum has also been found to be STS (RPR) Non-reactive and Negative for HIV- and HCV by PCR. Serum units were dispensed into acid-washed 500-mL polypropylene containers to make up five (5) serum pools. Each pool was spiked with a suite of additional trace elements including copper as Cu + at various concentrations. The Target Value assigned for each PT material is the robust mean of the results reported by all participants in this event. The robust statistics were obtained utilizing algorithms based on those presented in ISO 58:005E Statistical methods for use in proficiency testing by interlaboratory comparisons. Values for serum copper range from µg/l (.5 µmol/l) to 07 µg/l (.6 µmol/l). Acceptable ranges for serum copper are based on fixed criteria of ±5%, or ±95 µg/l below 65 µg/l. These criteria are consistent with those proposed by the OELM Network of EQAS organizers (, ) for trace elements in serum, and are slightly less stringent than those previously suggested for NYS (±0%). Discussion. Based on the above criteria, 9.7% of test results reported were judged as satisfactory, with two out of 9 participant laboratories (0.5%) reporting or more of the 5 results outside the acceptable ranges.. A. Taylor, J. Angerer, J. Arnaud, F. Claeys, R.L. Jones, O. Mazarrasa, E. Mairiaux, A. Menditto, P.J. Parsons, M. Patriarca, A. Pineau, S. Valkonen, J.-P. Weber and C. Weykamp Accreditation and Quality Assurance 006 0-5.. J. Arnaud, J.-P. Weber, C.W. Weykamp, P.J. Parsons, J. Angerer, E. Mairiaux, O. Mazarrasa, S. Valkonen, A. Menditto, M. Patriarca, and A. Taylor Clinical Chemistry 008 5 89-899. Trace Elements PT Program www.wadsworth.org/testing/lead/index.htm

Serum Copper Test Results, 0 Event # ROBUST STATISTICAL SUMMARY TARGET VALUE ASSIGNMENT AND STATISTICS Results (µg/l serum) SE-6 SE-7 SE-8 SE-9 SE-0 Robust Mean 07 80 07 9 Robust Standard Deviation 07 80 8 7 Standard Uncertainty RSD (%) 5. 5.9 5.7 5.8 5. Number of Sample Measurements 9 9 9 9 9 Acceptable Range: Upper Limit 85 09 66 5 6 Lower Limit 76 57 0 70 5 notes: Results reported as less than the method detection limit are excluded from statistical calculations.

Serum Copper Test Results, 0 Event # PERFORMANCE OF PARTICIPATING LABORATORIES Lab Code Method SE-6 Results (µg/l serum) SE-7 SE-8 SE-9 SE-0 Info Only Target Values: 07 80 07 9 07 DRC/CC-ICP-MS 7 09 555 8 59 Info 0 ICP-MS 7 88 56 090 68 7 ICP-MS 5 906 7 8 506 Info 56 ICP-AES/OES 00 800 00 00 00 60 ICP-MS 00 70 0 900 0 6 ICP-MS 95 69 6 905 0 79 DRC/CC-ICP-MS 0 860 0 00 70 97 ICP-MS 00 800 0 00 50 00 ICP-MS 5 880 8 7 86 Info 06 ICP-MS 90 680 0 80 80 9 ICP-MS 958 7 958 8 Info 05 ICP-MS 070 90 50 50 00 HR-ICP-MS 066 809 7 969 06 Info 5 ICP-MS 650 70 60 60 960 Info 59 ICP-MS 909 7 9 009 66 ETAAS-Z 979 700 8 986 08 Info 0 DRC/CC-ICP-MS 078 868 059 9 Info 57 ICP-AES/OES 07 878 09 508 Info 8 ICP-MS 06 00 57 96 75 Percent satisfactory results for all participants: 9.7 % notes: reported outside upper limit Info only: results included for informational purposes only. reported outside lower limit notes: Results reported as less than the method detection limit are excluded from statistical calculations.

DRC/CC-ICP-MS New York State Department of Health Serum Copper Test Results, 0 Event # STATISTICAL SUMMARY BY METHOD ETAAS-Z HR-ICP-MS ICP-AES/OES ICP-MS All Laboratories Results (µg/l serum) SE-6 SE-7 SE-8 SE-9 SE-0 96 979 066 0 5 00 07 9.9 9 0 8 8.7 96 700 809 89 55 8 6. 9 8 6 6. 7 7 8 7 7 87 08 7.8 9 06 9 6.7 7 9 986 969 096 6 00 66 8. 9 07 7 7. 50 78 08 06 5 76 80 9 0.8 9 0 0 9. notes: Insufficient data for calculation.

Event #, 0 Serum Selenium The test materials for serum Se were prepared from human serum obtained from Tennessee Blood Services, Inc. The units were tested by FDA approved methods and found to be Non-reactive for Anti-HIV-/, Anti-HCV.0 and HBsAg. The serum has also been found to be STS (RPR) Non-reactive and Negative for HIV- and HCV by PCR. Serum units were dispensed into acid-washed 500-mL polypropylene containers to make up five (5) serum pools. Each pool was spiked with a suite of additional trace elements including selenium as Se + at various concentrations. The Target Value assigned for each PT material is the robust mean of the results reported by all participants in this event. The robust statistics were obtained utilizing algorithms based on those presented in ISO 58:005E Statistical methods for use in proficiency testing by interlaboratory comparisons. Values for serum selenium range from 9 µg/l (.7 µmol/l) to 9 µg/l (.90 µmol/l). Acceptable ranges for serum selenium are based on fixed criteria of ±0%, or ± µg/l below 0 µg/l. These criteria are a little less stringent than those proposed by the OELM Network of EQAS organizers (±5% or ±8 µg/l below 55 µg/l) (, ) for trace elements in serum. As performance for serum Se improves among NYS-permit laboratories, consideration will be given to adopting the OELM criteria. Discussion. Based on the above criteria, 00% of test results reported were judged as satisfactory, with none of the 5 participant laboratories reporting or more of the 5 results outside the acceptable ranges.. A. Taylor, J. Angerer, J. Arnaud, F. Claeys, R.L. Jones, O. Mazarrasa, E. Mairiaux, A. Menditto, P.J. Parsons, M. Patriarca, A. Pineau, S. Valkonen, J.-P. Weber and C. Weykamp Accreditation and Quality Assurance 006 0-5.. J. Arnaud, J.-P. Weber, C.W. Weykamp, P.J. Parsons, J. Angerer, E. Mairiaux, O. Mazarrasa, S. Valkonen, A. Menditto, M. Patriarca, and A. Taylor Clinical Chemistry 008 5 89-899. Trace Elements PT Program www.wadsworth.org/testing/lead/index.htm

Serum Selenium Test Results, 0 Event # ROBUST STATISTICAL SUMMARY TARGET VALUE ASSIGNMENT AND STATISTICS Results (µg/l serum) SE-6 SE-7 SE-8 SE-9 SE-0 Robust Mean 9 0 9 Robust Standard Deviation 7 0 8 9 9 Standard Uncertainty 5 6 RSD (%) 7.5 6.8 8.8 8.5 8. Number of Sample Measurements 5 5 5 5 5 Acceptable Range: Upper Limit 65 7 0 75 Lower Limit 77 7 8 8 notes: Results reported as less than the method detection limit are excluded from statistical calculations.

Serum Selenium Test Results, 0 Event # PERFORMANCE OF PARTICIPATING LABORATORIES Lab Code Method SE-6 Results (µg/l serum) SE-7 SE-8 SE-9 SE-0 Info Only Target Values: 9 0 9 07 DRC/CC-ICP-MS 9 0 6 Info 0 DRC/CC-ICP-MS 88 96 8 7 ICP-MS 9 0 7 Info 56 DRC/CC-ICP-MS 00 0 76 9 00 6 DRC/CC-ICP-MS 6 9 99 7 79 DRC/CC-ICP-MS 8 9 95 0 9 00 DRC/CC-ICP-MS 5 97 6 Info 06 DRC/CC-ICP-MS 9 9 0 6 9 DRC/CC-ICP-MS 8 5 0 5 Info 05 ICP-MS 9 85 97 HR-ICP-MS 5 9 98 Info 5 ETAAS-Z 9 6 78 87 8 Info 66 ETAAS-Z 00 0 80 90 Info 67 DRC/CC-ICP-MS 5 9 96 0 5 Info 0 DRC/CC-ICP-MS 9 6 00 58 Info Percent satisfactory results for all participants: 00.0 % notes: reported outside upper limit Info only: results included for informational purposes only. reported outside lower limit notes: Results reported as less than the method detection limit are excluded from statistical calculations.

DRC/CC-ICP-MS New York State Department of Health Serum Selenium Test Results, 0 Event # STATISTICAL SUMMARY BY METHOD ETAAS-Z HR-ICP-MS ICP-MS All Laboratories Results (µg/l serum) SE-6 SE-7 SE-8 SE-9 SE-0 0 6 5 6.8 96 6 7 7 5 7 7.5 0 7 0 6.7 0 5 0 5 8. 0 9 8 8. 79 9 90 6 5 9 8 9. 0 05 7 7.0 89 98 00 5 0 8 8. 0 6 7 7. 99 6 5 9 0 8.7 notes: Insufficient data for calculation.

Event #, 0 Serum Zinc The test materials for serum Zn were prepared from human serum obtained from Tennessee Blood Services, Inc. The units were tested by FDA approved methods and found to be Non-reactive for Anti-HIV-/, Anti-HCV.0 and HBsAg. The serum has also been found to be STS (RPR) Non-reactive and Negative for HIV- and HCV by PCR. Serum units were dispensed into acid-washed 500-mL polypropylene containers to make up five (5) serum pools. Each pool was spiked with a suite of additional trace elements including zinc as Zn + at various concentrations. The Target Value assigned for each PT material is the robust mean of the results reported by all participants in this event. The robust statistics were obtained utilizing algorithms based on those presented in ISO 58:005E Statistical methods for use in proficiency testing by interlaboratory comparisons. Values for serum zinc range from 59 µg/l (9.08 µmol/l) to 09 µg/l (6.8 µmol/l). Acceptable ranges for serum zinc are based on fixed criteria of ±5%, or ±5 µg/l below 00 µg/l. These criteria are consistent with those proposed by the OELM network of EQAS organizers () for trace elements in serum. Discussion. Based on the above criteria, 9.5% of test results reported were judged as satisfactory, with two out of 6 participant laboratories (7.7%) reporting or more of the 5 results outside the acceptable ranges.. A. Taylor, J. Angerer, J. Arnaud, F. Claeys, R.L. Jones, O. Mazarrasa, E. Mairiaux, A. Menditto, P.J. Parsons, M. Patriarca, A. Pineau, S. Valkonen, J.-P. Weber and C. Weykamp Accreditation and Quality Assurance 006 0-5.. J. Arnaud, J.-P. Weber, C.W. Weykamp, P.J. Parsons, J. Angerer, E. Mairiaux, O. Mazarrasa, S. Valkonen, A. Menditto, M. Patriarca, and A. Taylor Clinical Chemistry 008 5 89-899. Trace Elements PT Program www.wadsworth.org/testing/lead/index.htm

Serum Zinc Test Results, 0 Event # ROBUST STATISTICAL SUMMARY TARGET VALUE ASSIGNMENT AND STATISTICS Results (µg/l serum) SE-6 SE-7 SE-8 SE-9 SE-0 Robust Mean 09 0 59 6 06 Robust Standard Deviation 8 75 7 5 0 Standard Uncertainty 5 8 50 RSD (%) 7.6 7. 7.9 8. 9.8 Number of Sample Measurements 6 6 6 6 6 Acceptable Range: Upper Limit 770 75 68 78 7 Lower Limit 08 869 505 56 75 notes: Results reported as less than the method detection limit are excluded from statistical calculations.

Serum Zinc Test Results, 0 Event # PERFORMANCE OF PARTICIPATING LABORATORIES Lab Code Method SE-6 Results (µg/l serum) SE-7 SE-8 SE-9 SE-0 Info Only Target Values: 09 0 59 6 06 07 DRC/CC-ICP-MS 99 96 70 76 80 Info 0 ICP-MS 57 050 6 69 6 7 ICP-MS 8 0 57 660 9 Info 56 ICP-AES/OES 00 90 560 60 900 60 ICP-MS 0 960 560 580 900 6 ICP-MS 99 56 585 900 79 DRC/CC-ICP-MS 560 050 60 660 60 97 ICP-MS 80 960 570 590 00 00 ICP-MS 5 6 706 97 Info 06 ICP-MS 50 90 570 680 0 87 FAAS 50 000 550 580 90 9 ICP-MS 9 987 596 6 95 Info 05 ICP-MS 70 970 570 60 80 HR-ICP-MS 5 05 69 6 08 Info 5 ICP-MS 60 990 70 60 670 Info 55 ICP-MS 5 096 68 680 57 ICP-MS 50 9 56 59 90 58 ICP-MS 90 00 600 60 050 59 ICP-MS 95 967 55 6 90 6 ICP-MS 7 06 6 6 9 6 ICP-MS 60 0 650 70 70 66 FAAS 6 070 7 70 0 Info 0 DRC/CC-ICP-MS 69 67 687 56 Info 57 ICP-AES/OES 57 96 55 66 0 Info 58 FAAS 59 058 6 69 8 ICP-MS 80 50 590 670 860 Percent satisfactory results for all participants: 9.5 % notes: reported outside upper limit Info only: results included for informational purposes only. reported outside lower limit notes: Results reported as less than the method detection limit are excluded from statistical calculations.

DRC/CC-ICP-MS New York State Department of Health Serum Zinc Test Results, 0 Event # STATISTICAL SUMMARY BY METHOD FAAS HR-ICP-MS ICP-AES/OES ICP-MS All Laboratories Results (µg/l serum) SE-6 SE-7 SE-8 SE-9 SE-0 70 9 0 5 5 79 0 7 6.7 6 5 9.0 6 7 0 7 05 95 5 7 0.0 6 07 09 0.5 65 7 6 8 69 557 5 7 578 6.0 6 59 65 0.9 698 650 76 6 6 7 65 80.8 6 66 7.5 99 6 6 06 08 957 8 7 0 90 9. 6 066 97 9.5 notes: Insufficient data for calculation.

Event #, 0 Additional Trace Elements Reported in Serum Participant laboratories reported their analytical results for any additional trace elements (other than Al, Cu, Se and Zn) that are routinely reported so that a more complete characterization can be recorded for these PT materials. Results for additional trace elements are reported here, but no target value is implied nor are any acceptable ranges provided. These data are provided solely for educational and informational purposes. In addition to Al, Cu, Se and Zn, the serum pools were supplemented with additional trace elements as indicated below. Additional Elements (SE-6) As, Ba, Be, Cd, Co, Cr, Cs, Mn, Mo, Ni, Pb, Pt, Sb, Sn, Te, Tl, V, W and U Additional Elements (SE-7 and SE-9) Mn, Cr, V Trace Elements PT Program www.wadsworth.org/testing/lead/index.htm

Serum Additional Elements, 0 Event # Page Serum Antimony (µg/l) Lab Code Method SE-6 SE-7 SE-8 SE-9 SE-0 0 ICP-MS 6.9 <0.069 <0.069 <0.069 <0.069 7 ICP-MS 6.5 <0.00 <0.00 <0.00 <0.00 Serum Arsenic (µg/l) Lab Code Method SE-6 SE-7 SE-8 SE-9 SE-0 97 DRC/CC-ICP-MS 6 <0 <0 <0 <0 Serum Barium (µg/l) Lab Code Method SE-6 SE-7 SE-8 SE-9 SE-0 0 ICP-MS 8..8 0.6.7 0.79 7 ICP-MS 7.5.80 0.7.65 0.88 97 ICP-MS 8.5 *. <.0 <.0 <.0 *Outlier Arithmetic mean 8.0 - - - - SD 0.6 - - - - n - - - - Serum Beryllium (µg/l) Lab Code Method SE-6 SE-7 SE-8 SE-9 SE-0 7 ICP-MS 6.77 <0.50 <0.50 <0.50 <0.50 97 ICP-MS 7. <0. <0. <0. <0. Serum Bismuth (µg/l) Lab Code Method SE-6 SE-7 SE-8 SE-9 SE-0 97 ICP-MS <.0 <.0 <.0 <.0 <.0 Serum Cadmium (µg/l) Lab Code Method SE-6 SE-7 SE-8 SE-9 SE-0 0 ICP-MS 6.99 <0.0 <0.0 <0.0 0.9 7 ICP-MS 6.7 <0.05 <0.05-0.8 97 DRC/CC-ICP-MS 6. <0.5 <0.5 <0.5 <0.5 Arithmetic mean 6.67 - - - - SD 0.5 - - - - n - - - -

Serum Additional Elements, 0 Event # Page Serum Chromium (µg/l) Lab Code Method SE-6 SE-7 SE-8 SE-9 SE-0 7 DRC/CC-ICP-MS 6.66.7.77.59 0.7 56 DRC/CC-ICP-MS 6.5.0.. <.0 6 DRC/CC-ICP-MS 6.... *.7 79 DRC/CC-ICP-MS 6.8..7. 0. 97 DRC/CC-ICP-MS 6.9..7.5 <.0 06 DRC/CC-ICP-MS 7.0..5. <.0 05 ICP-MS 6.5.0.. <0. HR-ICP-MS 6.89..8.8 0.8 *Outlier Arithmetic mean 6.7..5. 0.5 SD 0. 0. 0. 0. 0.0 n 8 8 8 8 Serum Cobalt (µg/l) Lab Code Method SE-6 SE-7 SE-8 SE-9 SE-0 0 ICP-MS. 0. 0.7 0.7 0.9 7 ICP-MS.99 0.099 0.5 0.80 0. 56 DRC/CC-ICP-MS.9 <.0 <.0 <.0 <.0 6 ICP-MS.9 0. 0. 0. 0. 79 DRC/CC-ICP-MS.0 <0. 0. 0. 0. 97 ICP-MS.6 <.0 <.0 <.0 <.0 06 ICP-MS. <.0 <.0 *.0 *.0 HR-ICP-MS.90 0.06 0.9 0. 0. *Outlier Arithmetic mean.0 0.5 0.6 0.9 0.7 SD 0. 0.08 0.07 0.05 0.08 n 8 5 5 5 Serum Iodine (µg/l) Lab Code Method SE-6 SE-7 SE-8 SE-9 SE-0 7 ICP-MS 56. 55. 66. 9.0 55. 6 DRC/CC-ICP-MS 8 7 57 6 79 ICP-MS 58 56 66 9 57 97 ICP-MS 7..8 56. 8..0 06 ICP-MS 55.6 50.8 6..9 5.9 Arithmetic mean 5 5 6 5 5 SD 5 5 5 6 n 5 5 5 5 5

Serum Additional Elements, 0 Event # Page Serum Iron (µg/l) Lab Code Method SE-6 SE-7 SE-8 SE-9 SE-0 57 ICP-AES/OES 5 0 5 50 Serum Lead (µg/l) Lab Code Method SE-6 SE-7 SE-8 SE-9 SE-0 7 ICP-MS.0 <0. <0. <0. <0. 97 DRC/CC-ICP-MS 0.0 <0. <0. <0. <0. Serum Lithium (µg/l) Lab Code Method SE-6 SE-7 SE-8 SE-9 SE-0 7 ICP-MS 0.7 0.965 0.69. 0.87 Serum Manganese (µg/l) Lab Code Method SE-6 SE-7 SE-8 SE-9 SE-0 0 ICP-MS 8.9.5.6..0 7 ICP-MS 8.0 0.9.05.0 0.98 79 DRC/CC-ICP-MS 9..7.. 0.9 97 DRC/CC-ICP-MS 8. 0.9...0 06 ICP-MS 9..7.0.7 *.5 05 ICP-MS 7.8 0..0.7 0.9 HR-ICP-MS 8.0 0.59.88.75 0.7 *Omitted Arithmetic mean 8.5.. 0.9 SD 0.6 0.8 0. 0. 0. n 7 7 7 7 6 Serum Mercury (µg/l) Lab Code Method SE-6 SE-7 SE-8 SE-9 SE-0 7 ICP-MS.08 - - - - 97 ICP-MS <5.0 <5.0 <5.0 <5.0 <5.0 Serum Molybdenum (µg/l) Lab Code Method SE-6 SE-7 SE-8 SE-9 SE-0 0 ICP-MS 7.9 0.55 0.59 0.5 0.70 7 ICP-MS 7.7 0.778 0.760 0.7 0.70 79 ICP-MS 7.6 0.9 0.8 0.7 0.7 97 ICP-MS *.0 *.8 *.6 *.0 <.0 *Omitted Arithmetic mean 7.6 0.7 0.7 0.6 0.70 SD 0. 0. 0. 0. 0.00 n

Serum Additional Elements, 0 Event # Page Serum Nickel (µg/l) Lab Code Method SE-6 SE-7 SE-8 SE-9 SE-0 7 ICP-MS 7. - - 0.68.7 79 DRC/CC-ICP-MS 6. <0. 0. 0. 5.5 97 ICP-MS 7.8 <.0 <.0 <.0 5. 06 ICP-MS <0 <0 <0 <0 <0 Arithmetic mean 7. - - - - SD 0.8 - - - - n - - - - Serum Platinum (µg/l) Lab Code Method SE-6 SE-7 SE-8 SE-9 SE-0 0 ICP-MS.9 <0.6 <0.6 <0.6 <0.6 79 ICP-MS <0 <0 <0 <0 <0 Serum Silver (µg/l) Lab Code Method SE-6 SE-7 SE-8 SE-9 SE-0 79 ICP-MS <0. 0. <0. 0. <0. 97 ICP-MS <.0 <.0 <.0 <.0 <.0 Serum Tellurium (µg/l) Lab Code Method SE-6 SE-7 SE-8 SE-9 SE-0 7 ICP-MS.9 <0.089 <0.089 <0.089 <0.089 97 ICP-MS. <.0 <.0 <.0 <.0 Serum Thallium (µg/l) Lab Code Method SE-6 SE-7 SE-8 SE-9 SE-0 0 ICP-MS. <0.0097 <0.0097 0.07 0.08 97 ICP-MS.0 <.0 <.0 <.0 <.0 Serum Thorium (µg/l) Lab Code Method SE-6 SE-7 SE-8 SE-9 SE-0 7 ICP-MS <0.0 <0.0 <0.0 <0.0 <0.0

Serum Additional Elements, 0 Event # Page 5 Serum Tin (µg/l) Lab Code Method SE-6 SE-7 SE-8 SE-9 SE-0 0 ICP-MS 8. 0.5 0.6 0.5 0. 7 ICP-MS 7.70 <0.8 <0.8 <0.8 <0.8 97 ICP-MS 7.9 <5.0 <5.0 <5.0 <5.0 Arithmetic mean 8.0 - - - - SD 0. - - - - n - - - - Serum Tungsten (µg/l) Lab Code Method SE-6 SE-7 SE-8 SE-9 SE-0 7 ICP-MS 6.7 <0.68 <0.68 <0.68 <0.68 Serum Uranium (µg/l) Lab Code Method SE-6 SE-7 SE-8 SE-9 SE-0 7 ICP-MS 0.690 <0.0 <0.0 <0.0 <0.0 Serum Vanadium (µg/l) Lab Code Method SE-6 SE-7 SE-8 SE-9 SE-0 7 DRC/CC-ICP-MS 6.89 9.69-0.6 0.68 79 DRC/CC-ICP-MS 7. 0.6 <0. 0.7 0.

ATOMIC SPECTROMETRY METHODS New York State Department of Health Trace Elements in Serum METHOD NOTES A- ETAAS-Z (Electrothermal atomic absorption spectrometry with Zeeman background correction) A- ETAAS other (i.e., D, S-H background correction) A- FAAS (Flame atomic absorption spectrometry) A- CV-AAS (Cold vapor atomic absorption spectrometry) A-5 HG-AAS (Hydride generation atomic absorption spectrometry) A-6 AFS (Atomic fluorescence spectrometry) A-7 Other INDUCTIVELY COUPLED PLASMA P- ICP-MS (Inductively coupled plasma - mass spectrometry) P- DRC/CC-ICP-MS (ICP-MS used in the Dynamic Reaction Cell or Collision Cell mode) P- ICP-AES/OES (ICP atomic/optical emission spectrometry) P- HR-ICP-MS (High resolution ICP-MS) P-5 ETV-ICP-MS (Electrothermal vaporization ICP-MS) P-6 ID-ICP-MS (Isotope dilution ICP-MS) P-7 Other ELECTROCHEMICAL METHODS E- ASV (Anodic stripping voltammetry without digestion) E- ASV-LeadCare (Anodic stripping voltammetry using the ESA LeadCare system) E- Fluoride specific electrode E- Other MOLECULAR FLUORIMETRY F- EtOAc (Ethyl acetate-acetic acid extraction method for determination of erythrocyte protoporphyrin) F- Aviv hematofluorometry (for determination of EP at hematocrit 5) F- Helena ZPP (for determination of zinc protoporphyrin in µmol ZPP/mol heme) F- Other OTHER METHODS If your method is not listed in the above list, please describe it briefly.