ISPUB.COM. The Video-Intubating Laryngoscope. M Weiss THE LARYNGOSCOPE INTRODUCTION TECHNICAL DESCRIPTION

Similar documents
Laryngoscopy: Time to broaden our horizon.

The Glidescope Ò system: a clinical assessment of performance

LEVITAN S FIBREOPTIC STYLET: BEYOND BARRIERS. - Our Perspective.

Educational Session: Evaluation and Management of the Difficult Airway

Comparison of the Airtraq to the Bonfils Fibroscope for Endotracheal Intubation in a Simulated Difficult Airway

Displacement of the epiglottis during intubation with the Pentax-AWS Airway Scope. Suzuki, Akihiro ; Katsumi, Norifumi ; Honda, Takashi ; Sasakawa,

Recent Advances in Airway Management HA Convention 2014

A clinical evaluation of the Bonfils Intubation Fibrescope*

The reasons 13/11/ Cost 2. Availability 3. Comparison 4. Complications 5. Knowledge. Pulmonary and critical care medicine (PCCM) fellows.

Airway/Breathing. Chapter 5

DIFFICULT AIRWAY MANAGMENT. Dr.N.SANTHOSH KUMAR MD ANESTHESIA (2 nd Yr)

Clinical Study McGrath Video Laryngoscope May Take a Longer Intubation Time Than Macintosh Laryngoscope

Airway Anatomy. Soft palate. Hard palate. Nasopharynx. Tongue. Oropharynx. Hypopharynx. Thyroid cartilage

Difficult Airway. Victor M. Gomez, M.D. Pulmonary Critical Care Medicine Medical City Dallas Hospital

Use of angulated video-intubation laryngoscope in children undergoing manual in-line neck stabilization

Video Laryngoscopy and its future in Airway Management

Equipment Difficult airway management: the Bullard laryngoscope. intubation stylet. Markus Weiss MD, Uwe Schwarz MD, Andreas Ch.

Unanticipated difficult tracheal intubation - during routine induction of anaesthesia in an adult patient

Video laryngoscopy in paediatric anaesthesia in South Africa

This interdisciplinary clinical support document provides guidelines for the safe establishment of an artificial airway.

L.J. Hoeve and R.H.M. van Poppelen * (Received 12 July 1989) (Accepted 10 August 1989)

Preface... Acknowledgements... Contributors... 1 The Difficult Airway: Definitions and Algorithms The Expected Difficult Airway...

How do you use a bougie as an airway adjunct for endotracheal intubation?

Dr.Bharghavi.M 2 nd year post graduate Dept of Anaesthesia

Use of the Aintree Intubation Catheter with the Laryngeal Mask Airway and a Fiberoptic Bronchoscope in a Patient with an Unexpected Difficult Airway

Haemodynamic response to orotracheal intubation: direct laryngoscopy versus fiberoptic bronchoscopy

Comparison of the Berman Intubating Airway and the Williams Airway Intubator for fibreoptic orotracheal intubation in anaesthetised patients.

Advanced Airway Management. University of Colorado Medical School Rural Track

PRODUCTS FOR THE DIFFICULT AIRWAY. Courtesy of Cook Critical Care

Anesthetic challenges when elective case becomes emergent

(ix) Difficult & Failed Intubation Queen Charlotte s Hospital

PREDICTORS OF DIFFICULT INTUBATION: STUDY IN KASHMIRI POPULATION

Z.U.M.J.Vol.19; N.5; September; 2013

9/20/18. Ear To Sternal Notch. Primary Methods to Rescue & Prevent Failed Intubation. Ear to Sternal Notch Position

RESPIRATION AND THE AIRWAY First clinical experience of tracheal intubation with the SensaScope Ò, a novel steerable semirigid video stylet

Airway/Breathing. Chapter 5

Cronicon ANAESTHESIA. Khaled Mohammed Elnaghy 1 and Javier Yuste 2 * Abstract. Keywords: Intubation; Video laryngoscopes; GlideScope; LMA CTrach

Airway/Breathing. Chapter 5

LARYNGOSCOPES/TRACHEASCOPES

Endoscopy. Pulmonary Endoscopy

1 Chapter 40 Advanced Airway Management 2 Advanced Airway Management The advanced airway management techniques discussed in this chapter are to

Endotracheal intubation with airtraq W versus storz W videolaryngoscope in children younger than two years - a randomized pilot-study

Chapter 40 Advanced Airway Management

Introducing the Fastrach-LMA. Prepared by Jim Medeiros, NREMT-P Regional Field Coordinator Lord Fairfax EMS Council

HELP PROTECT YOUR PATIENTS AND PREVENT COMPLICATIONS.

British Journal of Anaesthesia 100 (4): (2008) doi: /bja/aen002 Advance Access publication January 31, 2008

The LMA CTrach TM, a new laryngeal mask airway for endotracheal intubation under vision: evaluation in 100 patients

Is the Airtraq optical laryngoscope effective in tracheal intubation by novice personnel?

Airway Management. Teeradej Kuptanon, MD

Omiros Chalkeidis*, Georgios Kotsovolis, Apostolos Kalakonas, Maria Filippidou, Christos Triantafyllou, Dimitris Vaikos, Epaminondas Koutsioumpas

EUROANESTHESIA 2007 Munich, Germany, 9-12 June 2007

Other methods for maintaining the airway (not definitive airway as still unprotected):

Orotracheal Intubation

Overview. Chapter 37. Advanced Airway Techniques. Sellick Maneuver 9/11/2012

INFORMED CONSENT FOR publication of the present

ENDOTRACHEAL INTUBATION POLICY

Hemodynamic responses to orotracheal intubation with a video laryngoscope. in infants: a comparison study

General OR Rotations GOALS & OBJECTIVES

A comparison between the GlideScope Ò Video Laryngoscope and direct laryngoscope in paediatric patients with difficult airways a pilot study

AIRWAY MANAGEMENT PRODUCTS

NiravKotak 1, Abhishek Kesarwani 2 1

Bryan-Dumon Series II Rigid Bronchoscope and Stent Placement Kit USER MANUAL

Evaluation of the Airtraq Ò and Macintosh laryngoscopes in patients at increased risk for difficult tracheal intubation*

AIRWAY MANAGEMENT AND VENTILATION

Airway Workshop Lecture. University of Ottawa

Airway Management & Safety Concerns Experience from Bariatric Surgery

Intubation techniques

Angkana Lurngnateetape,, MD. Department of Anesthesiology Siriraj Hospital

The Laryngeal Mask and Other Supraglottic Airways: Application to Clinical Airway Management

British Journal of Anaesthesia 102 (4): (2009) doi: /bja/aep013 Advance Access publication February 20, 2009

Comparison. F Agro immobilization. to DL Trauma/SCI. GS experiences. to other. GS experiences. GS experiences. to DL.

Equipment: NRP algorithm, MRSOPA table, medication chart, SpO 2 table Warm

First clinical experience of tracheal intubation with the SensaScope, a novel steerable semirigid video stylet

Difficult Airway. Department of Anesthesiology University of Colorado Health Sciences Center (prepared by Brenda A. Bucklin, M.D.)

The Superiority Of Mcgrath Videolaryngoscope After Failed Conventional Laryngoscopy

Hong Kong Journal of Emergency Medicine. KL Tsui, CY Hung, CW Kam. t p= p=0.004

Optimising tracheal intubation success rate using the Airtraq laryngoscope

Predictors of difficult intubation a simple approach

Translaryngeal tracheostomy

Comparison between C-MAC video-laryngoscope and Macintosh direct laryngoscope during cervical spine immobilization

The Parker Flex-Tip Tube versus a Standard Tube for Fiberoptic Orotracheal Intubation

Study of Comparison of Standard And English Macintosh Laryngoscope Blades in Patients Undergoing Surgery Under General Anaesthesia.

British Journal of Anaesthesia 102 (1): (2009) doi: /bja/aen342

Evaluation of Tracheal Intubation mmculty in Patients with Cervical Spine Immobilization

Mouth opening with cervical collars Fig 1 Types of semi-rigid collar used (left to right): Stifneck (Laerdal Medical Corp.); Miami J (Jerome Medical);

Comparison of upper lip bite test with modified mallampati classification for prediction of difficult obstetric intubation

The difficult airway in critical care

In 2011 I received an unrestricted lecture honorarium from Ambu I have been loaned equipment by Intavent Direct (Teleflex) and Aircraft Medical As an

Fiberoptic bronchoscope and C-MAC video laryngoscope assisted nasal-oral tube exchange: two case reports

Anatomy and Physiology. The airways can be divided in to parts namely: The upper airway. The lower airway.

Clinical Comparison of Lightwand-guided versus Conventional Endotracheal Intubation

Emergency Department/Trauma Adult Airway Management Protocol

Patient-specific depth of endotracheal intubation-from anthropometry to the Touch and Read Method

Comparison of laryngoscopy and intubating conditions using kings vision laryngoscope and C-MAC video laryngoscope

Case Report Tracheal Intubation with Aura-i and ascope-2: How to Minimize Apnea Time in an Unpredicted Difficult Airway

Brief report Failed Intubating Laryngeal Mask Airway-Guided Blind Endotracheal Intubation in a Severe Postburn Contractured Neck Patient.

Rohan R. Walvekar, MD. Basic Sialendoscopy Set. Basic Sialendoscopy Set. Disclosure I have the following relationship(s) with commercial interests.

VANDERBILT UNIVERSITY MEDICAL CENTER DIVISION OF ANESTHESIOLOGY CRITICAL CARE MEDICINE AIRWAY MANAGEMENT

Pre anaesthetic evaluation of difficult tracheal intubation

Nicolette Mosinski MPAS, PA-C

Transcription:

ISPUB.COM The Internet Journal of Anesthesiology Volume 3 Number 1 M Weiss Citation M Weiss.. The Internet Journal of Anesthesiology. 1998 Volume 3 Number 1. Abstract A Macintosh intubating laryngoscope has been modified with a guide bore hole, leading from the bottom of the handle through the lateral flange of the blade to the blade tip. An ultrathin video-endoscope is inserted in the bore hole. It transmits the view from the distal blade tip directly onto a video-display and also provides airway illumination. Oxygen flowing at the tip of the video-endoscope protects the lens against fogging up and secretions and allows apnoic oxygenation during intubation. The device can be used for routine direct laryngoscopy in the usual manner. Video-transmission of the view from the distal blade tip allows demonstration, teaching and monitoring tracheal intubation. The video-view around the curvature of the blade provides a better visualisation of the cords than obtained by direct vision. Thus, the video-intubating laryngoscope is potentially helpful during difficult direct laryngoscopy to guide the endotracheal tube into the larynx using the video-view. Because the device can be used for both, routine as well difficult tracheal intubation, it may be a helpful tool to manage unanticipated difficult laryngoscopy. INTRODUCTION THE LARYNGOSCOPE Difficulties with tracheal intubation are mostly caused by difficult direct laryngoscopy with impaired view to the vocal cords. (1) Unfortunately, despite of all the informations currently available, no single factor reliably predicts these difficulties. (2,3) Consequently, many difficult intubations will not be recognized until after induction of anesthesia. Unanticipated difficult intubation can lead to critical situations, especially in those patients who are at risk for gastric regurgitation, who are difficult to ventilate by mask or who have limited cardio-pulmonary reserves. A plastic Macintosh laryngoscope has been modified with a guide bore hole for insertion of an endoscopic image and light transmitting system. The bore hole (inner diameter 3.0 mm) leads from the bottom of the handle through the handle and the flange of the blade and ends 30 mm before the blade tip. The laryngoscope itself contains no batteries, no light source and no additional light transmitting elements. The laryngoscope is thought to be disposable but it can be cleaned or desinfected with standard solutions (Fig. 1/2). Many endoscopic intubation laryngoscopes such as the Bullard laryngoscope, the Upsher laryngoscope or the Wuscope have been designed to visualize the vocal cords around the corner looking through a proximal viewfinder. (4,5,6) Although they re useful devices, there re not suitable for direct laryngoscopy and therefore, they re not used for routine tracheal intubation. I present a new device, the video-intubating laryngoscope (VIL), primarily designed for monitoring routine tracheal intubation, but also potentially useful to manage difficult laryngoscopy. TECHNICAL DESCRIPTION 1 of 7

Figure 1 THE VIDEO-ENDOSCOPE Fig. 1: Disposable standard Macintosh laryngoscope with bore hole A flexible, ultrathin, 2 meter long video-endoscope (Manufacturer : Volpi AG, Schlieren, Switzerland) has been designed for insertion into the guide bore hole of the plastic laryngoscope (Fig. 3/4). The video-endoscope (outer diameter 2.8 mm) carries optic fibres (10 000 pixels) for image transmission and light fibres for airway illumination. The distal lens of the video-endoscope has a 70 forward field view and a fixed focus of 40 mm. An integrated channel (internal diameter 0.7 mm) allows oxygen flowing at the lens. The video-endoscope is connected with the proximal plug to a video-monitor system and to an oxygen source. The scope can be cleaned with standard desinfectants (excepted : acetone / formalin ) or can be sterilized with ethylene oxide or Steris ( hydroxyperoxid liquid chemical sterilisation ). Figure 3 Fig. 3: Ultrathing video-endoscope carring image and light transmitting fibers and an oxygen channel Figure 2 Fig. 2: Disposable angulated Macintosh laryngoscope with bore hole 2 of 7

Figure 4 Figure 5 Fig. 4: Cross section through a plastic laryngoscope with inserted video-endoscope Fig. 5: Assembled Macintosh video-intubating laryngoscope No 4 THE ASSEMBLED DEVICE The ultrathin video-endoscope is inserted into the guide bore hole of the laryngoscope. The video-endoscope is locked in the laryngoscope by just fitting in the laryngoscope s bore hole, avoiding rotational and longitudinal displacement. The position and axis of the video-endoscope in the distal blade is designed so, that the video- display gives a view around the curvature (Fig. 5) respectively around the angulated tip (Fig. 4) of the blade. The transverse plane of the blade tip is seen at the upper board of the monitor screen. The video-endoscope leaves the bottom of the handle as a 1.7 meter long cable for connecting to the video-monitoring system. Figure 6 Fig. 6: Assembled angulated Macintosh video-intubating laryngoscope USE OF THE VIDEO-INTUBATING LARYNGOSCOPE MONITORING TRACHEAL INTUBATION Before starting anesthesia, the VIL is connected to the video 3 of 7

monitor system / oxygen source and is checked for proper function. Direct laryngoscopy is performed in the anesthetized patient and the trachea is intubated under direct vision as usual, the monitor view is not necessarily used. The video view transmitted from the distal blade can be used by the attending anesthetist to follow the intubation procedure and also to confirm final endotracheal tube (ETT) position between the vocal cords (Fig. 7). Figure 8 Fig. 8: The vocal cords are visualized using the video-view from the distal, angulated blade tip Figure 7 Fig. 7: Monitoring tracheal intubation - the video-view from the distal blade tip allows to follow the conventional intubation procedure Figure 9 Fig. 9: The ETT respectively the stylet is directed through the cords using the video-view GUIDING TRACHEAL INTUBATION During difficult direct laryngoscopy, the video-view around the curvature of the blade is used to visualize the cords on the monitor screen (Fig. 8). Optionally the epiglottis can be picked up as with a straight intubation blade. The endotracheal tube with a protruding stylet or bougie is placed into the oropharynx as far as possible under direct vision. Then, the ETT is directed through the cords into the trachea using the video-view from the distal blade tip (Fig. 9). Finally, proper tube placement between the vocal cords is confirmed on the monitor screen (Fig. 10). 4 of 7

Figure 10 Fig. 10: The ETT is confirmed and adjusted between the vocal cords ( black mark ) using the monitor view was felt to be of special value. As the presented video-intubating laryngoscope consists of a disposable plastic laryngoscope with a bore hole and a reusable video-endoscopic system, different sizes and types of such plastic laryngoscopes could be used with a single optic-system cost-effectively for routine tracheal intubation. The fact that a second anesthetist could directly see all details of the intubation procedure, makes it an excellent tool for demonstration, teaching and monitoring conventional laryngoscopy. Video-recording enables documentation and review of the intubation sequence later on. In situations where direct visualisation of the cords is impaired, the VIL allows to overcome the obstructed view to the larynx using conventional intubation technique and the video view around the curvature of the blade (Fig. 8). DISCUSSION Video-laryngoscopy with a flexible fiberscope passed through the nose or with a rigid telescope introduced through the mouth is a well known diagnostic technique in otolaryngology. (7) Aoyama reported the successful use of flexible transnasal video-laryngoscopy to guide an orally inserted curved ETT through the glottis under video-control. (8) The VIL combines video-laryngoscopy, an indirect laryngoscopic visualisation technique with conventional direct laryngoscopy. Therefore, the device can be used for routine tracheal intubation and may be helpful in case of difficult direct laryngoscopy with impaired view to the vocal cords. During routine intubation, the VIL, remaining a regular laryngoscope, is handled in an identical manner as a standard laryngoscope (Fig. 7). First clinical applications showed that the light-weight fiberoptic transmitting cable does not interfere with stearing the laryngoscope. Integration of the ultrathin video-endoscope in the lateral flange allows conventional laryngoscopy without impaired direct vision to the cords. Airway illumination provided by the endoscope was jugded to be equal to that of a standard laryngoscope. The oxygen flow at the tip of the scope not only protected the lens against fogging up and secretions, but simultaneously allowed apnoic oxygenation during laryngoscopy. (9) Coordination of laryngeal manipulations by the second anesthetist using the video-laryngoscopic view 5 of 7 Preliminary, limited experiences in patients with direct laryngoscopic view Grade II and III ( classification by Cormack and Lehane ) showed, that the video-display from the distal blade gives an better view of the cords and the patients were intubated under monitor control without forced laryngoscopy or head-neck manipulations (Fig 9). CONCLUSION The presented video-intubating laryngoscope is a useful tool for documentation, teaching and monitoring tracheal intubation. Limited experiences using the device for difficult intubation management suggest that the video-intubating laryngoscope can become a helpful aid during difficult direct laryngoscopy. References 1. Samsoon GL, Young JRB: Difficult tracheal intubation. Anaesthesia 1987;42:487-90 2. Tse JC, Rimm EB, Hussain A: Predicting difficult endotracheal intubation in surgical patients scheduled for general anesthesia: a prospective blind study.anesthesia and Analgesia 1995;81:254-8 3. Rocke DA, Murray WB, Rout CC, Gouws E: Relative risk analysis of factors associated with difficult intubation in obstetric anaesthesia.anesthesiology 1992;77:67-73 4. Bjoraker DG: The Bullard intubating laryngoscope.anesthesiology Review 1990;17:64-70 5. Pearce AC, Shaw S, Macklin S: Evaluation of the Upsherscope.Anaesthesia 1996;51:561-564 6. Wu T, Chou H: A new laryngoscope: the combination intubating device.anesthesiology 1994;81:1085-1086 7. Metson R, Rauch SD: Videolaryngoscopy in the office -A critical evaluation.otolaryngology - Head and Neck Surgery 1992;106:56-59 8. Aoyama K, Takenaka I, Sata T, Shigematsu A. Use of the fiberscope - video camera system for difficult tracheal intubation.british Journal of Anaesthesia 1996;77:662-624 9. Todres ID, Crone RK: Experience with a modified

laryngoscope in sick infants. Critical Care Medicine 6 of 7 1981;9:544-545

Author Information Markus Weiss, M.D. Department of Neonatal and Paediatric Intensive Care, University Children's Hospital 7 of 7