Annexin V APC Assay Kit

Similar documents
Lipid Droplets Fluorescence Assay Kit

7-AAD/CFSE Cell-Mediated Cytotoxicity Assay Kit

LDL Uptake Flow Cytometry Assay Kit

Nuclear Extraction Kit

LDL Uptake Cell-Based Assay Kit

MitoCheck Complex II Activity Assay Kit

Multi-Parameter Apoptosis Assay Kit

MitoCheck Complex I Activity Assay Kit

HDAC1 Inhibitor Screening Assay Kit

HDAC Cell-Based Activity Assay Kit

Cholesterol Fluorometric Assay Kit

Annexin V-APC/7-AAD Apoptosis Kit

Nuclear Extraction Kit

NF-κB (p65) Transcription Factor Assay Kit

Annexin V-FITC Apoptosis Detection Kit with SYTOX

For the rapid, sensitive and accurate measurement of apoptosis in various samples.

Dienes Derivatization MaxSpec Kit

RayBio Annexin V-FITC Apoptosis Detection Kit Plus

Annexin V-PE Apoptosis Detection Kit

LDL Uptake Cell-Based Assay Kit

Annexin V-Cy3 Apoptosis Detection Reagent

Malachite Green Phosphate Assay Kit. Item No

ab Lysosome/Cytotoxicity Dual Staining Kit

RayBio Annexin V-FITC Apoptosis Detection Kit

HDAC Cell-Based Activity Assay Kit

Fatty Acid Amide Hydrolase Inhibitor Screening Assay Kit

HDAC Fluorometric Activity Assay Kit

RayBio Annexin V-Cy5 Apoptosis Detection Kit

Orexin 2 Receptor Reporter Assay Kit

Receptor (rat) Reporter Assay Kit EP 4. Item No Customer Service Technical Support

7-AAD/CFSE Cell-Mediated Cytotoxicity Assay Kit

Annexin A1 (human) ELISA Kit

Annexin V-Cy3 Apoptosis Detection Kit

The Annexin V Apoptosis Assay

Annexin V-FITC Apoptosis Detection Kit

RayBio Cathepsin D Activity Assay Kit

PE Annexin V Apoptosis Detection Kit User Manual KT40001

ROS Activity Assay Kit

CytoPainter LysoGreen Indicator Reagent

Morinaga Mouse C-peptide ELISA Kit

Glycerol Colorimetric Assay Kit

Ascorbate Assay Kit. Item No Customer Service Technical Support

ab Exosome Isolation and Analysis Kit - Flow Cytometry, Cell Culture (CD63 / CD81)

PPARα, δ, γ Complete Transcription Factor Assay Kit

ab Exosome Isolation and Analysis Kit - Flow Cytometry, Plasma

Instructions for Use. APO-AB Annexin V-Biotin Apoptosis Detection Kit 100 tests

ab Membrane fluidity kit Instructions for Use For the detection of membrane fluidity in cells

Blood Urea Nitrogen Detection Kit

ab Exosome Isolation and Analysis Kit - Flow Cytometry, Cell culture

Instructions. Fuse-It-mRNA easy. Shipping and Storage. Overview. Kit Contents. Specifications. Note: Important Guidelines

Human Utrophin 500 tests

ab Cell Invasion Assay (Basement Membrane), 24-well, 8 µm

CytoPainter Lysosomal Staining Kit - Blue Fluorescence

ab CytoPainter Golgi/ER Staining Kit

TGR5 (GP-BAR1) Reporter Assay Kit

MitoCheck Complex V Activity Assay Kit

Rat Hemoglobin A1c (HbA1c) Kit Instructions

ab65336 Triglyceride Quantification Assay Kit (Colorimetric/ Fluorometric)

Product # R8132 (Explorer Kit) R8133 (Bulk Kit)

HDAC Fluorometric Activity Assay Kit

Exo-Glow TM Exosome Labeling Kits

ab Mammalian Cell Lysis Buffer 5X

RayBio Maltose and Glucose Assay Kit

MPO Inhibitor Screening Assay Kit

In vitro human regulatory T cell expansion

INSULIN MOUSE SERUM KITS

ab65311 Cytochrome c Releasing Apoptosis Assay Kit

ab Lipid Peroxidation (MDA) Assay kit (Colorimetric/ Fluorometric)

TECHNICAL BULLETIN. Catalog Number RAB0447 Storage Temperature 20 C

ab Annexin V- mfluor Blue 570 Detection

Cisbio Bioassays MAP-Tau assay is only intended for quantitative measurement of microtubule-associated protein tau (MAP-Tau) using HTRF technology.

TECHNICAL BULLETIN. Phospho-Akt (pser 473 ) ELISA Kit for detection of human, mouse, or rat phospho-akt (pser 473 ) in cell and tissue lysates

ab Nuclear Extract Kit

Human HIV (1+2) antigen&antibody ELISA Kit

by nexttec TM 1 -Step

Sphingomyelin Colorimetric Assay Kit

For research or further manufacturing use only. Not for injection or diagnostic procedures.

Hemoglobin Colorimetric Assay Kit

Cathepsin D Activity Assay Kit

In vitro human regulatory T cell expansion

MALDI Sepsityper Kit

Alpha-Tubulin Housekeeping 10,000 tests

Phosphate buffered saline (PBS) for washing the cells TE buffer (nuclease-free) ph 7.5 for use with the PrimePCR Reverse Transcription Control Assay

91154 PRIME-XV T Cell CDM Liquid 1 L Additional package sizes are available at request

Mouse C-Peptide ELISA Kit

ab SREBP-2 Translocation Assay Kit (Cell-Based)

Cathepsin K Activity Assay Kit

ab65344 Uric Acid Assay Kit (Colorimetric/Fluorometric)

SERUM GLUCAGON KITS PROTOCOL

Cell Lysis Buffer. Catalog number: AR0103

SREBP-2 Transcription Factor Assay Kit

Fluoro Cholesterol Total Cholesterol Assay Kit

Cholesterol Fluorometric Assay Kit. Item No

NF-κB p65 (Phospho-Thr254)

RayBio Phenylalanine Fluorometric Assay Kit

Instructions. Fuse-It-Color. Overview. Specifications

Transcription:

Annexin V APC Assay Kit Item No. 601410 www.caymanchem.com Customer Service 800.364.9897 Technical Support 888.526.5351 1180 E. Ellsworth Rd Ann Arbor, MI USA

TABLE OF CONTENTS GENERAL INFORMATION 3 Materials Supplied 4 Safety Data 4 Precautions 4 If You Have Problems Materials Supplied GENERAL INFORMATION Kit will arrive packaged as a 4 C kit. After opening kit, store individual components as stated below. 5 Storage and Stability 5 Materials Needed but Not Supplied Item Number Item Quantity/Size Storage INTRODUCTION 6 About This Assay PRE-ASSAY PREPARATION 7 Reagent Preparation ASSAY PROTOCOL 8 Flow Cytometry ANALYSIS 9 Performance Characteristics RESOURCES 10 Troubleshooting 11 Notes 11 Warranty and Limitation of Remedy 601411 Annexin V APC Assay Reagent 1 vial/100 tests 4 C 600302 Cell-Based Assay Annexin V Binding Buffer (10X) 1 vial/50 ml RT 601361 DAPI Viability Dye 1 vial/100 µl 4 C If any of the items listed above are damaged or missing, please contact our Customer Service department at (800) 364-9897 or (734) 971-3335. We cannot accept any returns without prior authorization.! WARNING: THIS PRODUCT IS FOR RESEARCH ONLY - NOT FOR HUMAN OR VETERINARY DIAGNOSTIC OR THERAPEUTIC USE. GENERAL INFORMATION 3

Safety Data This material should be considered hazardous until further information becomes available. Do not ingest, inhale, get in eyes, on skin, or on clothing. Wash thoroughly after handling. Before use, the user must review the complete Safety Data Sheet, which has been sent via email to your institution. Precautions Please read these instructions carefully before beginning this assay. If You Have Problems Technical Service Contact Information Phone: 888-526-5351 (USA and Canada only) or 734-975-3888 Fax: 734-971-3641 Email: Hours: techserv@caymanchem.com M-F 8:00 AM to 5:30 PM EST In order for our staff to assist you quickly and efficiently, please be ready to supply the lot number of the kit (found on the outside of the box). Storage and Stability This kit will perform as specified if stored as directed in the Materials Supplied section and used before the expiration date indicated on the outside of the box. Materials Needed But Not Supplied 1. A 96-well v-bottom plate or FACS tubes for staining and running samples, as appropriate for your flow cytometer. 2. A flow cytometer equipped with 633 nm and 350 (or 405) nm lasers and filters for around 700 nm and 450 nm. 3. PBS, ph 7.4 4 GENERAL INFORMATION GENERAL INFORMATION 5

About This Assay INTRODUCTION Cayman s Annexin V APC Assay Kit employs an APC-conjugated annexin V as a probe for phosphatidylserine on the outer membrane of apoptotic cells. DAPI is used as a marker of cell membrane permeability seen in very late apoptotic or necrotic cells. This kit is valuable for researchers looking to assess the degree of apoptosis induced by experimental compounds, and can be useful in pharmacology, immunology, cancer, or physiology research. The reagents provided in the kit are sufficient to run 100 samples when using a 96-well plate format. PRE-ASSAY PREPARATION NOTE: Annexin V APC is light sensitive. Do not expose to direct intense light. Reagent Preparation Annexin V Binding Buffer Prepare 1X Binding Buffer by diluting the Cell-Based Assay Annexin V Binding Buffer (10X) (Item No. 600302) 1:10 in distilled water. Mix well and keep at room temperature. The diluted 1X Binding Buffer will be stable for one year at room temperature. Annexin V APC/DAPI Staining Solution Prepare sufficient Annexin V APC/DAPI Staining Solution to stain 100 samples by adding 50 µl of Annexin V APC Assay Reagent (Item No. 601411) and 100 µl of DAPI Viability Dye (Item No. 601361) to 10 ml of 1X Binding Buffer. For fewer samples, adjust volume as necessary. The Annexin V APC/DAPI Staining Solution will be stable for one hour at 4 C. 6 INTRODUCTION PRE-ASSAY PREPARATION 7

Flow Cytometry ASSAY PROTOCOL We recommend using only suspension cells for flow cytometric staining of annexin V. This protocol describes staining in a polypropylene 96-well v-bottom plate. Alternatively, FACS tubes can be used for staining by scaling up volumes approximately 5-fold. 1. Culture cells under assay conditions designed to induce/inhibit apoptosis according to your protocols. 2. Collect 1-5 x 10 5 cells into each well and centrifuge at 400 x g for five minutes. Discard the supernatant. Optional: Perform antibody staining of cell surface proteins as desired, wash once with 1X Binding Buffer and continue with the protocol. 3. Resuspend the cells in 100 µl of Annexin V APC/DAPI Staining Solution. Mix well to ensure separation of individual cells. Incubate the cells in the dark at room temperature for 10 minutes. 4. Centrifuge at 400 x g for five minutes and discard supernatant. 5. Add 200 µl of PBS, ph 7.4, and analyze immediately using 633 nm excitation and ~700 nm emission for APC and 350 (or 405) nm excitation and 450 nm emission for DAPI. Performance Characteristics ANALYSIS Ultraviolet light induces apoptosis in Jurkat cells. Jurkat cells were le untreated (Panel A) or s mulated Figure 1. Ultraviolet light induces apoptosis in Jurkat cells. Jurkat cells were left untreated (Panel A) or stimulated with 200 mj/cm 2 ultraviolet light (Panel B) and then incubated for four hours at 37 C. Cells were stained with Annexin V APC at a 1:200 dilution in 1X Binding Buffer for 15 minutes at room temperature in the dark. After centrifugation and removal of the supernatant, cells were resuspended in 1:100 DAPI in PBS. Data were collected on a MACSQuant cytometer from Miltenyi and analyzed using FlowJo software. 8 ASSAY PROTOCOL ANALYSIS 9

RESOURCES NOTES Troubleshooting Problem Possible Causes Recommended Solutions Strong staining for both annexin V APC and DAPI in all samples, including controls A. Cells are not healthy B. Adherent cells may be compromised in processing A. Start with healthy cells B. Try different cell line or different removal method No signal for annexin V APC A. Annexin V APC/DAPI Staining Solution not prepared properly B. No apoptosis induced A. Check dilutions B. Vary treatment time or compound dosage Cells lost during processing (adherent) A. Annexin V staining protocol incompatible with your cells B. Cells progressed too far through apoptosis A. Try different cell line B. Lower stimulus dosage or shorten incubation time Warranty and Limitation of Remedy Buyer agrees to purchase the material subject to Cayman s Terms and Conditions. Complete Terms and Conditions including Warranty and Limitation of Liability information can be found on our website. This document is copyrighted. All rights are reserved. This document may not, in whole or part, be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form without prior consent, in writing, from Cayman Chemical Company. 01/25/2017, Cayman Chemical Company, Ann Arbor, MI, All rights reserved. Printed in U.S.A. 10 RESOURCES RESOURCES 11