Improved access, ultra-low displacement 1 and the highest fixation strength 1. Q-FIX All-Suture Anchor

Similar documents
Improved access, ultra-low displacement 1 and the highest fixation strength 1. Q-FIX All-Suture Anchor

Active, yet simple deployment, now with a curved approach. SUTUREFIX All-Suture Anchor

The next generation in all suture implant technology. Q-FIX All-Suture Implants

JuggerKnot and JuggerKnotless Soft Anchor. All-Inclusive Brochure

SureLock All-Suture Anchor System

HIP ARTHROSCOPY BROCHURE

JuggerKnot Soft Anchor 1.4/1.5 mm with Percutaneous Instrumentation for Low Profile/Trans-Cuff SLAP Repair

Hip Arthroscopy. All Inclusive Brochure

ToggleLoc. Fixation Device. Surgical Technique. Femoral Fixation for ACL Reconstruction SPORTS MEDICINE. Surgical Protocol by Mark Gittins, D.O.

Femoral Fixation for ACL Reconstruction. Surgical Protocol by Mark Gittins, D.O.

JuggerKnot Soft Anchor 1.5 mm with Percutaneous Instrumentation for Low Profile/Trans-Cuff PASTA Repair

BTB ACL Reconstruction with the ToggleLoc Fixation Device with ZipLoop Technology. Surgical Technique by James R. Andrews, M.D.

Medial Portal ACL Reconstruction

ToggleLoc Inline Device

MCL Reconstruction Surgical Protocol by Tarek Fahl, M.D.

ComposiTCP Anchor with BroadBand Tape

Arthroscopic and Mini-Open Rotator Cuff Repair

Arthroscopic and Mini-Open Rotator Cuff Repair. using JuggerKnot Soft Anchor 2.9 mm with ALLthread Knotless PEEK-Optima Anchor Surgical Technique

Precautionary Statement ( )

Coracoid Bone Conserving Acromioclavicular Joint Reconstruction using ToggleLoc Device with ZipLoop Technology

Y-Knot Flex NEW. All-Suture Anchor System

ACL Reconstruction Single Tibial Tunnel Double Bundle

with ACL Reconstruction Single Tibial Tunnel Double Bundle Surgical Protocol by Eric McCarty, M.D.

Lateral Ankle Ligamentous Instability. Surgical Technique by Jeffrey Nacht, M.D.

ACL Reconstruction Medial Portal

Arthroscopic Shoulder Instability Repair Using the Curved Guide and Anchor Delivery System

Arthroscopic PCL Reconstruction

Technique Guide. MULTIFIX P PEEK 4.5mm Knotless Fixation Implant

Technique Guide. *smith&nephew MAGNUM 2 Knotless Implant

ToggleLoc Fixation Device with ZipLoop Technology

Midfoot Repair. Surgical Protocol by Stuart Miller, M.D.

Technique Guide. *smith&nephew SPEEDSCREW Fully Threaded Knotless Implant

MULTIFIX S Knotless Implants

Scan-Anchor....Not just another soft tissue bone anchor, but a new reference! Presentation booklet

Chart a course for meniscal preservation

The first cannulated retrograde drill providing precision and control from a guide wire. ACUFEX TRUNAV Retrograde Drill

JuggerKnot Soft Anchor 1.0 mm Mini

AFX. Femoral Implant. System. The AperFix. AM Portal Surgical Technique Guide. with the. The AperFix System with the AFX Femoral Implant

with ACL Reconstruction Single Tibial Tunnel Double Bundle Surgical Protocol by Eric McCarty, M.D.

Surgical Protocol by E. Lyle Cain, M.D. and Jeffrey R. Dugas, M.D. of the American Sports Medicine Institute

Comprehensive Product Offerings for Your Rotator Cuff Repair

Comprehensive Product Offerings for Your Rotator Cuff Repair

Arthroscopic Shoulder Repair Using the Smith & Nephew KINSA Suture Anchor

A sequenced approach to flush graft placement. GLENOID BONE LOSS SYSTEM Procedural Solution

Surgical Technique. Figure 1 Figure 4. Figure 3 Figure 5. Figure 6

Surgical Technique. Figure 1 Figure 4. Figure 3 Figure 5. Figure 6

JuggerKnot Soft Anchor 1.0 mm Mini. Scapholunate Ligament Repair/Reconstruction. Brochure and Surgical Technique

ENDOBUTTON Family of Fixation Devices. Often imitated, never equaled, the gold standard for femoral fixation.

ENDOBUTTON Family of Fixation Devices. Often imitated, never equaled, the gold standard for femoral fixation.

Hard to reach areas require specific solutions

Acute AC Joint Reconstruction Surgical Protocol by Eric McCarty, M.D.

Technique Guide. *smith&nephew N8TIVE ACL Anatomic ACL Reconstruction System

Features. The hollow core can be filled with autograft or allograft bone.

GENERAL TECHNIQUE GUIDE

BICEPTOR Tenodesis System

ROTATOR CUFF REPAIR WITH STATAK SUTURE ANCHORS

The AperFix II System

Technique Guide. VersiTomic. ReelX STT Double-Row Achilles G-Lok. J. Martin Leland III, M.D. J. Martin Leland III, M.D. Proximal Biceps Tenodesis

Surgical Technique. Calcaneal Locking Plate

Surgical Technique. CONQUEST FN Femoral Neck Fracture System

surgical technique A P P L I C A B L E T O A L L C U RV T E K B O N E T U N N E L I N G S Y S T E M I N D I C AT I O N S

Technique For SLAP Repair in 2016

Surgical Technique. Proximal Humerus Locking Plate

Precisely locate anatomic femoral ACL insertion sites 1. ACUFEX PINPOINT Anatomic ACL Guide System

JuggerKnot Soft Anchor 1.0 mm Mini

Surgical Technique. Distal Humerus Locking Plate

Surgical Technique. Suture. Insertion Rod. U-Guide. Grommet Swing Arm. Figure 1. Figure 2. Suture

Double Bundle ACL Reconstruction using the Smith & Nephew Outside-In Anatomic ACL Guide System

Rotator Cuff Repair using JuggerKnot Soft Anchor 2.9mm Surgical Technique

ACL reconstruction with the ACUFEX Director Drill Guide and. ENDOBUTTON CL Fixation System. *smith&nephew. Knee Series Technique Guide ENDOBUTTON CL

Surgical Technique. Olecranon Locking Plate

Treating Massive Rotator Cuff Tears and Revisions

Humeral SuturePlate. Surgical Technique

Surgical Technique. Clavicle Locking Plate

Locking Radial Head Plates

Shoulder Restoration System

AcUMEDr. Locking Proximal Humeral Plate. PoLARUSr PHPt

with ZipLoop Technology For ACL Reconstruction ACL Reconstruction Medial Portal Surgical Protocol by Jefferey Michaelson, M.D.

28 Surgical Technique

SURGICAL TECHNIQUE THE TENDON ANCHOR SYSTEM

VersiTomic Flexible Reaming System

DEVELOPED BY MEDSHAPE, INC. IN CONJUNCTION WITH PATRICK ST. PIERRE, M.D. BICEPS TENODESIS ARTHROSCOPIC AND SUBPECTORAL SURGICAL TECHNIQUE

Contents. Chapter 1 4 Chapter Chapter Chapter Chapter 5 15

ARTHROTUNNELER TUNNELPRO SYSTEM

Arthrex PassPort Button Cannula. Maximize visibility and maneuverability inside and outside of the arthroscopic workspace

Flower Medium Headless & Cannulated Screws

HEALIX TRANSTEND Implant System: A percutaneous solution for partial tears of the rotator cuff. Partial tear. Complete solution.

LOWER EXTREMITIES SINGLE-USE INSTRUMENTATION SURGICAL IMPLANTATION TECHNIQUE. First Metatarsal Phalangeal Joint FOOT THE DIFFERENCE IS MOVING.

Ankle Stabilization Surgical Technique using the Split Peroneus Longus Tendon. Surgical Protocol by Chad Brady, D.P.M.

Knee Surgical Technique

Surgical Technique International Version. Clavicle Locking Plate

State-of-the-art performance for fast, efficient procedures QUANTUM 2. Controller System for use with COBLATION Wands

Ascension. Silicone MCP surgical technique. surgical technique Ascension Silicone MCP

RIGIDFIX CURVE CROSS PIN SYSTEM

Thumb UCL Repair with InternalBrace Ligament Augmentation. Surgical Technique. Thumb UCL Repair with InternalBrace Augmentation

Rotator Cuff Repair Utilizing the ALLthread Suture Anchor. by Scott Kuiper, M.D.

2018 Professional Education Course Calendar

Axi+LineTM Proximal Bunion CorrectionSystem. Surgical Technique

DARCO. Bow 2 Plate SURGIC AL TECHNIQUE

Foot and Ankle Technique Guide Proximal Inter-Phalangeal (PIP) Fusion

Transcription:

Improved access, ultra-low displacement 1 and the highest fixation strength 1 All-Suture Anchor

All-Suture Anchors The All-Suture Anchor is the next generation of all-suture anchor technology, providing the benefits of a small, soft anchor with the characteristics of traditional anchor designs. This uniquely designed, radially expanding anchor offers compact size, high fixation strength, 2,3,4 low displacement, 4,5 consistent deployment, 2,3 and is now available with a curved guide system. Low Displacement The unique design and deployment mechanism of the All-Suture Anchor provides best-in-class performance, with regard to displacement during cyclic loading. The deployment of the anchor against the inserter shaft and the tensioning of the sutures to approximately 140 newtons ensures the least displacement of any allsuture anchor. 1 mm displacement 9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0 0 Displacement at 400 cycles (in 30 pcf) 5 BIORAPTOR 2.3 PK 1.8 SUTUREFIX Ultra 1.7 1.45 (#1) 1.45 (#2) ConMed Y-Knot Flex 1.3 Stryker Iconix 1 Compact Size The platform offers compact 1.8mm (single-loaded) or 2.8mm (double-loaded) anchor sizes. The new MINI Suture Anchor anchor minimizes bone removal by shortening the drill tunnel depth by 5mm. This new drill depth of 17.1mm is approximately 23% shorter than the existing 1.8mm anchor. 17.1mm 22.4mm 25mm Zimmer Soft Anchor System Smith & Nephew All-Suture Anchor Stryker ICONIX TM All-Suture Anchor System MINI 1.8mm Arthrex FiberTak TM 2mm Inserter is 2mm below bone surface Radial expanding deployment Consistent deployment 1,2 The All-Suture Anchor is designed to provide consistent deployment due to the radially expanding implant design and unique delivery system. During anchor deployment, the distal tip of the inserter functions as a knot pusher against the anchor body, independent of the cortical layer. The sutures are then pretensioned to approximately 140 newtons 5 to complete anchor deployment and remove any suture laxity. Max Load (N) Pilot hole depth of the 1.8mm MINI and 1.8mm All-Suture Anchors compared to the Arthrex FiberTak 1.6mm Soft Anchor and Zimmer 1.5mm Soft Anchor. Max Load of Labral Repair Anchors Tested (in 30 pcf) 5 325 300 275 250 225 200 175 150 125 BIORAPTOR 2.3 PK 1.8 SUTUREFIX Ultra 1.7 1.45 (#1) 1.45 (#2) ConMed Y-Knot Flex 1.3 Stryker Iconix 1 Superior Fixation The All-Suture Anchor provides superior fixation properties when compared to the BIORAPTOR 2.3 PK Suture Anchor as well as other commercially available all-suture anchors. 1 2 3

CURVED Guide System The CURVED Guide System improves access to challenging shoulder and hip pathology. The Curved Drill Guide improves access and trajectory when drilling bone tunnels. This may reduce the risk of articular surface perforation, bicortical perforation, and converging tunnels. The distal design of the curve places it where it will be most effective: in the working space within the joint. Laser marks assist with positioning the drill guide The crescent-shaped laser mark indicates the orientation of the curvature. The vertical laser mark indicates the trajectory of the drill bit. Compatible with 1.8mm Available in both Shoulder and Hip (XL) lengths, the Curved Drill Guide is compatible with our existing 1.8mm standard and MINI All-Suture Anchors. Unique tactile and visual cues The Curved Drill Guide has intuitive visual and tactile cues that facilitate drill guide positioning and anchor placement. TRUJECTORY Technology directs the drill bit where you expect it to go The Curved Drill Guide is the most accurate drill guide available*, producing less than 1 degree of deviation. Smith & Nephew Arthrex FiberTak TM Stryker ICONIX TM Cayenne Medical SureLock TM Length of Curve 1.92" 1.25" 2.01" 3.50" 4.31" Angle 13 15 11 12 and 25 20 Indentation on the handle is oriented with concave aspect of curve, providing tactile feedback to assist with positioning of drill guide on bone surface. 13 distal curve is positioned for optimal effectiveness within the working space of the joint. Tighter distal curve Mid-shaft curve *Measured as drill deviation vs. drill guide angle. 4 5

Shoulder Repair The All-Suture Anchor is designed for procedures like rotator cuff repair and labral repair in which anatomic space is limited. Hip Repair Designed for acetabular labral repair and reconstruction, the All-Suture Anchor delivers performance characteristics that meet or exceed those of other all-suture anchors. 1,4 The 1.8mm Suture Anchor is a great option for SLAP and Bankart repairs with implant performance superior to commonly used all-suture anchors. 1,4 The 2.8mm anchor s fixation performance 2 and small footprint makes it a great option for rotator cuff repair, ideal for medial row fixation where performance is needed and space may be limited. It can be inserted with a standard drill and drill guide, or a tapered punch, streamlining insertion steps and potentially saving operating time. The Curved Drill Guide allows anchors to be placed confidently in the inferior aspect of the glenoid. The curvature of the guide and trajectory of the drill bit may reduce the risk of converging tunnels or bicortical perforation. The 1.8mm All-Suture Anchor is ideal for hip labral repairs. With its unique deployment mechanism, this radially expanding implant is designed to deliver high fixation strength, and demonstrated the least amount of displacement of any all-suture anchor. 1,4 The 1.8mm Mini Anchor requires minimal bone removal for anchor insertion which makes it an optimal solution for treating pathology all around the acetabular rim. The Curved Drill Guide is designed to provide improved access to the acetabular rim compared to traditional straight delivery systems. And it allows for the anchor to be positioned closer to the articular side of the acetabular rim, with less risk of penetrating the acetabular articular cartilage. Indications for Use I All-Suture Anchors are intended to be used for soft tissue to bone fixation for: Shoulder: Bankart lesion repair; SLAP lesion repair; acromio-clavicular repair; capsular shift/capsulolabral reconstruction; deltoid repair; rotator cuff repair; biceps tenodesis. Hip: Acetabular labral repair. Knee: Extra-capsular repair: medial collateral ligament (MCL), lateral collateral ligament (LCL) and posterior oblique ligament; Iliotibial band tenodesis (IBT); patellar tendon repair; vastus medialis obliquus advancement (VMO); joint capsule closure. Foot & Ankle: Medial/Lateral repair and reconstruction; midfoot and forefoot repair; Hallux valgus reconstruction; Metatarsal ligament/ tendon repair or reconstruction; Achilles tendon repair Elbow: Ulnar or radial collateral ligament reconstruction; lateral epicondylitis repair; biceps tendon reattachment. Hand & Wrist: Collateral ligament repair; Scapholunate ligament reconstruction; Tendon transfers in phalanx; Volar plate reconstruction. 6 7

Ordering information All-Suture Anchors 1.8mm and 1.8mm MINI All-Suture Anchors Reference # Description Anchors: 72290123 1.8mm MINI All-Suture Anchor 25-1800 1.8mm All-Suture Anchor Disposable Kits: 72290125 1.8mm MINI Kit, disposable 72290126 1.8mm MINI Kit XL, disposable 25-1810 1.8mm Kit, disposable 25-1811 1.8mm Kit XL, disposable Reusable Instruments: 72290032 1.8mm Drill Guide, reusable 72290034 1.8mm Drill Guide XL, reusable 72290120 1.8mm Curved Drill Guide, reusable 72290119 1.8mm Curved Drill Guide XL, reusable 72290033 1.8mm Obturator, reusable 25-1812 1.8mm PATHFINDER Obturator, reusable Disposable Accessories: 72290024 1.8mm MINI Straight Drill, disposable 72290030 1.8mm Straight Drill, disposable 72290118 1.8mm Flexible Drill, disposable 2.8mm All-Suture Anchor Reference # Description Anchors: 25-2800 2.8mm All-Suture Anchor Disposable Kits: 25-2810 2.8mm Kit, disposable Reusable Instruments: 72290035 2.8mm Drill Guide, reusable 72290036 2.8mm Obturator, reusable 25-2812 2.8mm PATHFINDER Obturator, reusable 25-2820 2.8mm Bone Punch, reusable Disposable Accessories: 72290031 2.8mm Straight Drill, disposable Instrumentation The anchor platform offers a variety of instrumentation in order to meet your surgical preferences and facility needs. For the ultimate in convenience, we offer disposable, sterile instrumentation. We also offer reusable instrumentation if required/ desired. Example of reusable items for 1.8mm Example of disposable kit for 1.8mm Curved guides and flexible drill. Fish Mouth drill guide tip, 1.8mm Crown drill guide tip, 1.8mm Crown drill guide tip, 2.8mm All photos and diagrams are for illustrative purposes only. Products not to scale. For more information on the application of any products discussed in the presentation, as well as indications for use, contraindications, and product safety information, please consult the Instructions for Use (IFU) for such product. Manufactured by: ArthroCare Corporation 7000 West William Cannon Drive Austin, TX 78735 USA Distributed by: Smith & Nephew, Inc. 150 Minuteman Road Andover, MA 01810 USA www.smith-nephew.com T +1 978 749 1000 US Customer Service: +1 800 343 5717 Trademark of Smith & Nephew. 2017 Smith & Nephew. All rights reserved. Printed in USA. 06770 V2 01/18 Supporting healthcare professionals for over 150 years References 1. Douglass NP, Behn AW, Safran MR. Cyclic and Load to Failure Properties of All-Suture Anchors in Synthetic Acetabular and Glenoid Cancellous Bone. Arthroscopy. 2017 May;33(5):977-985.e5. doi: 10.1016/j.arthro.2016.11.022. Epub 2017 Jan 26. 2. Report P/N 49193-02 Rev. A 3. Report P/N 51963-01 Rev. B 4. Barber AB, Herbert MA. All-Suture Anchors: Biomechanical Analysis of Pullout Strength, Displacement, and Failure Mode. Arthroscopy. 2017 Jun;33(6):1113-1121. doi: 10.1016/j.arthro.2016.09.031. Epub 2016 Dec 22 5. Report P/N 49190-01 Rev. B