Comparisonof Classic- Laryngeal Mask Airway with I-Gel Airway,during Anaesthesia with Controlled Ventilation in Routine Surgical Procedures

Similar documents
ISSN X (Print) Research Article. *Corresponding author Dr. Souvik Saha

Dr. Ranjeet Rana De 1, Dr. Saurav Shekhar 2, Dr. D G Pathak 3, Dr. Harshwardhan 4, Dr. Shashank Dhiraj 5 1,2,4,5

Comparison of Ease of Insertion and Hemodynamic Response to Lma with Propofol and Thiopentone.

Comparison of the Hemodynamic Responses with. with LMA vs Endotracheal Intubation

JMSCR Vol 4 Issue 02 Page February 2016

Journal of Anesthesia & Clinical

Comparison of clinical performance of i-gel with laryngeal mask airway pro-seal in elective surgery in adults

A comparative study between i-gel and classical laryngeal mask airway in elective surgery under general anaesthesia

Other methods for maintaining the airway (not definitive airway as still unprotected):

Comparision of Hemodynamic Changes after Insertion of Classic Lma and Proseal Lma

I - Gel Versus Cuffed Tracheal Tube in Elective Laparoscopic Cholecystectomy A Clinical Comparative Study

A Comparative Study of Classic LMA and Proseal LMA in Paralyzed Anaesthetized Patients

Evaluation of Baska Mask Performance in Laparoscopic Cholecystectomy

Comparison of efficacy of the Laryngeal tube with the Laryngeal mask airway in securing the upper airway

COMPARATIVE CLINICAL EVALUATION OF PROSEAL LMA WITH I - GEL AIRWAY IN PATIENTS UNDERGOING ELECTIVE SURGICAL PROCEDURES UNDER GENERAL ANAESTHESIA

LMA Supreme Second Seal. Maintain the airway. Manage gastric contents. Meet NAP4 recommendations.

Use of the Intubating Laryngeal Mask Airway

ORIGINAL ARTICLE. Shashank Chitmulwar, MD, Charulata Deshpande, MD, DA ABSTRACT. ANAESTHESIA, PAIN & INTENSIVE CARE

A randomised comparison between Cobra PLA and classic laryngeal mask airway and laryngeal tube during mechanical ventilation for general anaesthesia

Comparison of the Berman Intubating Airway and the Williams Airway Intubator for fibreoptic orotracheal intubation in anaesthetised patients.

Comparative Evaluation of Performance of Videolaryngoscope vs Fastrach Intubating Laryngeal Mask Airway

Comparative study of Succinylcholine, Rocuronium and Vecuronium for intubation and hemodynamic changes during general anaesthesia

Veena Patodi*, Maina Singh, Surendra K. Sethi, Vini N. Depal, Neena Jain, Vijay Kumar

Veena Mathur, Deepak Garg, Neena Jain, Vivek Singhal, Arvind Khare, Surendra K. Sethi*

Attenuation of the Hemodynamic Responses to Endotracheal Intubation with Gabapentin Versus Fentanyl: A Randomized Double Blind Controlled Study

Deposited on: 11 February 2010

We will not be using the King LTS-D in our system!

I-gel vs cuffed tracheal tube during volume controlled ventilation in elective laparoscopic cholecystectomy

The Pro-Seal LMAtm And The Tracheal Tube: A Comparison Of Events At Insertion Of The Airway Device

Original Research Article. Amol P. Singam 1, Arpita A. Jaiswal 2 *, Ashok R. Chaudhari 1

Randomised comparison of the LMA Supreme with the I-Gel in spontaneously breathing anaesthetised adult patients

A Comparative Study of Two Disposable Supraglottic Devices in Diagnostic Laparoscopy in Gynecology

Comparison of I-gel with Baska Mask Airway for Controlled Ventilation in Obese Patients Undergoing Ambulatory Surgery: A Prospective Randomized Trial

CONTINUING EDUCATION IN HONOR OF NORMAN TRIEGER, DMD, MD

A Clinical Comparative Study Of Evaluation Of Proseal LMA V/S I-GEL For Ease Of Insertion And Hemodynamic Stability; A Study Of 60 Cases

J of Evolution of Med and Dent Sci/ eissn , pissn / Vol. 3/ Issue 64/Nov24, 2014 Page 13923

The Laryngeal Mask and Other Supraglottic Airways: Application to Clinical Airway Management

P V Praveen Kumar 1*, P. Archana 2. Original Research Article. Abstract

Citation British journal of anaesthesia, 104. pp ; 2010 is available onlin

Anatomy and Physiology. The airways can be divided in to parts namely: The upper airway. The lower airway.

International Journal of Health Sciences and Research ISSN:

A Comparative Study of Supreme LMA Vs I-gel: Two Supraglottic Airway Devices in Short Surgical Procedures

Recent Advances in Airway Management HA Convention 2014

Received 1 November 2009 Revised 8 December 2009 Accepted 10 December 2009

JMSCR Vol 06 Issue 11 Page November 2018

Airway Management Essentials Self-Study Guide

Equipment: NRP algorithm, MRSOPA table, medication chart, SpO 2 table Warm

AIRWAY MANAGEMENT AND VENTILATION

GENERAL ANAESTHESIA AND FAILED INTUBATION

Cricoid pressure: useful or dangerous?

Comparative evaluation of Ambu AuraGain with ProSeal laryngeal mask airway in patients undergoing laparoscopic cholecystectomy

Airway Management. DFMRT Casualty Care Examination Course. Revision notes for. January Les Gordon

University of Groningen

Airway Management and The Difficult Airway

Clinical Study McGrath Video Laryngoscope May Take a Longer Intubation Time Than Macintosh Laryngoscope

Adult Advanced Cardiovascular Life Support. Emergency Procedures in PT

DIFFICULT AIRWAY MANAGMENT. Dr.N.SANTHOSH KUMAR MD ANESTHESIA (2 nd Yr)

RESPIRATION AND THE AIRWAY Comparison of the i-gel with the cuffed tracheal tube during pressure-controlled ventilation

ORIGINAL RESEARCH ARTICLE

HOW TO CITE THIS ARTICLE:

Haemodynamic response to orotracheal intubation: direct laryngoscopy versus fiberoptic bronchoscopy

Advanced Airway Management. University of Colorado Medical School Rural Track

Airway/Breathing. Chapter 5

Deposited on: 24 February 2009

Comparative Evaluation of Supraglottic Devices i-gel and Fastrach LMA as Conduit for Blind Endotracheal Intubation

The LMA CTrach TM, a new laryngeal mask airway for endotracheal intubation under vision: evaluation in 100 patients

Facilitating EndotracheaL Intubation by Laryngoscopy technique and Apneic Oxygenation Within the Intensive Care Unit (FELLOW)

Subspecialty Rotation: Anesthesia

Study of Comparison of Standard And English Macintosh Laryngoscope Blades in Patients Undergoing Surgery Under General Anaesthesia.

Research Article. Shital S. Ahire 1 *, Shweta Mhambrey 1, Sambharana Nayak 2. Received: 22 July 2016 Accepted: 08 August 2016

Effect of Vecuronium in different age group

This interdisciplinary clinical support document provides guidelines for the safe establishment of an artificial airway.

FAILED ELECTIVE INTUBATION: PLAN A- C

ADVANCED AIRWAY MANAGEMENT

Airway Anatomy. Soft palate. Hard palate. Nasopharynx. Tongue. Oropharynx. Hypopharynx. Thyroid cartilage

Airway Workshop Lecture. University of Ottawa

Comparison of intracuff dexamethasone, lignocaine and normal saline on post extubation response - A prospective study

12/15/2010. Presented by: Jim Fox EMT-PS EMS-I EMS Assistant Coordinator Des Moines Fire Department

ISPUB.COM. M Roberts, M Mani, A Wilkes, E Flavell, N Goodwin INTRODUCTION

Rapid Sequence Induction

Original Contributions

Blind Insertion Airway Devices (BIAD)

student handbook BARS handbook September 2012.indd Front Cover 27/11/12 12:08 PM

Nicolette Mosinski MPAS, PA-C

FAILED INTUBATION DURING RSI: PLAN A, C & D

Anesthesia Monitoring. D. J. McMahon rev cewood

Advanced Airway Management PRESENTED BY: JOSIAH POIRIER RN, JOHN GRUBER FP-C

NiravKotak 1, Abhishek Kesarwani 2 1

S. K. Gvalani 1 *, Sushant Mane 2

Comparison of the i-gel and the LMA-Unique laryngeal mask airway in patients with mild to moderate obesity during elective short-term surgery

PHYSICIAN COMPETENCY FOR ADULT DEEP SEDATION (Ages 14 and older)

CAN T INTUBATE, CAN T VENTILATE: PLAN A- D

Success Rate of Airway Devices Insertion: Laryngeal Mask Airway Versus Supraglottic Gel Device

Comparison of the Baska â mask with the single-use laryngeal mask airway in low-risk female patients undergoing ambulatory surgery

Unanticipated difficult tracheal intubation - during routine induction of anaesthesia in an adult patient

Angkana Lurngnateetape,, MD. Department of Anesthesiology Siriraj Hospital

J. Brimacombe, 1 L. Holyoake, 2 C. Keller, 3 J. Barry, 4 D. Mecklem, 4 A. Blinco 5 and K. Weidmann 5

Comparison of hemodynamic and metabolic stress responses caused by endotracheal tube and Proseal laryngeal mask airway in laparoscopic cholecystectomy

Comparison of the clinical performance of i-gel, LMA Supreme and LMA ProSeal in elective surgery

Difficult Airway. Department of Anesthesiology University of Colorado Health Sciences Center (prepared by Brenda A. Bucklin, M.D.)

Transcription:

IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-0853, p-issn: 2279-0861.Volume 16, Issue 10 Ver. XIII (Oct. 2017), PP 39-43 www.iosrjournals.org Comparisonof Classic- Laryngeal Mask Airway with I-Gel Airway,during Anaesthesia with Controlled Ventilation in Routine Surgical Procedures Dr. Prateek Singh Bais 1,Dr. Amit Tyagi 1,,Dr. Deepesh Saxena 2, * Dr. Manoj Tripathi 3,Dr. Neha Rusia 4, Dr. Amir Laique Khan 1 1 Senior Resident, Department of Anesthesia and ctitical care, Dr.Ram Manohar Lohia Institute Of Medical Sciences, Lucknow, Uttar Pradesh India 2 Senior Resident, Department of Anesthesia and Critical care, Swami Dayanand Hospital, New Delhi 3 Assistant Professor, Department of Anesthesia and ctitical care, Dr.Ram Manohar Lohia Institute Of Medical Sciences, Lucknow, Uttar Pradesh India 4 Senior Resident, Department of Anesthesia and Critical care, Hindu Rao Hospital and North MCD Medical College, New Delhi Corresponding Author- Dr Manoj Tripathi Abstract: Background: Classic LMA was the first LMA to be introduced and has been considered the gold standard of all supraglottic airway device(sgad). The I-gel is another recently developed non-inflatable supraglottic airway device made of thermoplastic elastomer that provides seal, which improves as device warms to body temperature. Aims:The present study was conducted to evaluate and compare efficacy of LMA-classic & I-gel in terms of (i) number of attempts (ii) time taken to insert airway device. Setting and Design:This is a prospective randomized comparative controlled study done in our operation theatre over a period of 1 year, after ethical committee clearance. Material and Methods: The patients were randomly assigned in 2 groups comprising 25 patients each. Allocation was done using sealed envelope Group L: Classic LMA. (Size was selected as per kg body weight of the patient) = 25 patients. Group I: I-Gel (Size was selected as per kg body weight of the patient) = 25 patients. Statistical Analysis:The statistical analysis with Chi-Square test / Fisher exact test,student t-test/paired t-test, Wilcoxon Mann Whitney test were applied for categorical variables, statistical significance of different continuous variables,respectively. Results& Conclusion: The mean time taken to insert LMA was more than I-gel (15.44± 2.48 sec vs 11.24± 1.94 sec, P<.05) and the success rate of insertion in first attempt was 96%in LMA group and 100% in I-gel group. Keywords:Classic LMA, I-Gel, Supraglottic airway devices, Laryngeal mask airway. ----------------------------------------------------------------------------------------------------------------------------- ---------- Date of Submission: 17-10-2017 Date of acceptance: 28-10-2017 -------------------------------------------------------------------------------------------------------------------------------------- I. Introduction Maintenance of airway is an integral part of general anaesthesia. Now a day s airway management of patients has progressed from endotracheal tube to lesser invasive supraglottic airway devices. The supraglottic airway devices (SGAD) have been increasingly used since the introduction of Laryngeal Mask airway by Dr.Archie Brain in 1988. 1,2 The Classic LMA was the first LMA to be introduced and has been considered the gold standard of all SGAD. The Classic LMA is a single use, latex free, supraglottic airway device made of medical grade polyvinyl chloride with an inflatable cuffto wedge into the hypopharynxto provide a perilaryngeal seal, and hence it produces less pressor response and less hemodynamic changes.the I-gel is recently developed non-inflatable supraglottic airway device made of thermoplastic elastomer with an in-built gastric port and its perilaryngeal seal improves as the device warms to body temperature. Aims and Objectives: The aims and objectives of this study were to: (i) assess and compare the ease of insertion, (ii) number of attempts taken and time taken to insert LMA- Classic & I-gel airway (iii) assess and compare the adequacy of ventilation and compare hemodynamic response and to know the incidence of regurgitation and other perioperative complications. DOI: 10.9790/0853-1610133943 www.iosrjournals.org 39 Page

II. Materials & Methods This is a prospective randomized comparative controlled study with title Comparison of Classic- Laryngeal Mask Airway with I-gel Airway during Anaesthesia with Controlled Ventilation in Routine Surgical Procedures, after approval from ethical committee and institutional review board was conducted in our institute during period of one year.the patients were randomly assigned to one of the 2 groups comprising 25 patients each. Allocation was done using sealed envelope. Group L: Classic LMA. (Size was selected as per kg body weight of the patient) Group I: I-Gel (Size was selected as per kg body weight of the patient) Inclusion Criteria: (1) ASA physical status I & II patients. (2) Age between 18 years to 60 years. (3) Patients undergoing elective surgical procedures. (4) Weight between 40 to 100 kg. (5) Provision of written consent. Exclusion Criteria: (1)Patients refusal to give consent. (2) Inability to comply with the study procedures. (3) Uncooperative patient. (4) Any pathology of neck, upper respiratory tract or upper alimentary tract. (5) Predicted difficult airway, mouth opening < 2.0 cm, the view of the mouth will be scored by the method of Mallampati as modified by Samsoon & Young. (6) A body mass index > 35kg/m2. (7) Patients with history of obstructive sleep apnea. (8) Potentially full stomach patients. (9) Oesophageal reflux (hiatus hernia). A thorough pre-anaesthetic evaluation was done for all patients. Baseline hematological, biochemical & radiological investigations appropriate for the surgery were done. Also assessment was done to identify cases with difficult intubation.a full free voluntary, written and informed consent to participate in the study was taken from all patients included in study. All patients were given Tab.Alprazolam 0.25 mg orally night prior to surgery and at morning of surgery with sip of water. All patient were kept nil per orally for at least 8 hours preoperatively.the patient monitoring included pulse oximetry, non-invasive blood pressure monitoring, capnography and electrocardiography. After intravenous cannula, a drip of Lactated Ringer was started. Baseline measurements of pulse rate, non-invasive blood pressure, oxygen saturation and end tidal carbon dioxide were taken just before induction and administration of muscle relaxant, just before insertion of either device. Check test for airway devices was performed before use as recommended and it was lubricated with a water based gel. All patients were given intravenous Inj.Ondansetron 4mg and Inj. Glycoprrolate 4 µg/kg body weight, 5 minutes before insertion of SGAD. After pre-oxygenation with 100% oxygen for 3minutes anesthesia was induced with Inj.Thiopentone 5mg/kg body weight and maintained with Halothane at MAC 0.8% with N 2 O and Oxygen. Muscle relaxation was achieved by inj Vecuronium 0.1 mg/kg. The number of attempts, time taken, ease of insertion and hemodynamic changes were assessed and noted while procedure was done by anesthesiologist. All time duration were measured on a stopwatch. Lma-Classic Insertion Technique: The LMA is depicted with a semi-inflated cuff, held by the shaft with the left hand and introduced straight into the mouth. The LMA is held with the dominant hand. The hand holds the LMA like a pen, with the index finger placed at the junction of the cuff and the shaft, with the LMA opening oriented over the tongue. The LMA is passed behind the upper incisors, with the shaft parallel to the patient s chest and the index finger pointing toward the intubator. As the LMA is advanced, the mask portion is pressed against the hard palate by using index finger. The tube is then advanced in one smooth movement until a characteristic resistance is felt, as the upper esophageal sphincter is engaged.without holding the tube cuff is inflated with the air, this causes a characteristic outward movement of the tube of approximately 1.5cm. The longitudinal black line on shaft of tube should lie in midline against the upper lip. Any deviation may indicate misplacement of cuff and partial airway obstruction. I-Gel Insertion Technique: The standard technique of insertion involves the device to be held like a pen, guided into pharynx with index finger of the operator. Under direct vision, device is grasped and is introduced continuously into mouth towards hard palate until resistance is felt. Adequate placement of the device will be assessed by gently squeezing reservoir bag and observing end-tidal CO2 waveform and movements of chest wall, absence of audible leak & gastric insufflation. After insertion of airway device anaesthesia was maintained with Halothane MAC 0.8% and N 2 O in Oxygen. Vecuronium Bromide 0.01 mg/kg was used as muscle relaxant.monitoring of Heart Rate (HR),Systolic Blood Pressure (SBP), Diastolic Blood Pressure (DBP), Mean Arterial Pressure (MAP)and saturated partial pressure of O 2 (SPO 2 ) was done immediately after insertion of device (IAI), then 1 minute, 3 minute, 5 minute, 10 minute and 15 minute after insertion of airway device. At the end of surgery neostigmine 0.04 mg / kg i.v. + glycopyrrolate 0.02 mg / kg was administered for reversal of residual muscle relaxation and airway device was removed. DOI: 10.9790/0853-1610133943 www.iosrjournals.org 40 Page

III. Statistical Analysis The statistical Chi-Square test / Fisher exact test were applied for categorical variables. For comparing the statistical significance of different continuous variables between two groups (LMA & I-Gel) student t-test was used and in case where variable were not following normal distribution non-parametric Wilcoxon Mann Whitney test was applied. For determining statistical significance between baseline and over a different period of time of the same variable under each group, Paired t-test was applied. The level of statistical significance was taken as p 0.05 and the data was analyzed by using SPSS statistical software 12.0. IV. Observation And Result: As seen in Table no.1 there is no statistical difference between the two groups in terms of number of attempts, as the p value is 0.871(>0.05). Only in 1 patient two attempts were taken to insert C-LMA (L) while in I-gel was inserted in all the 25 patients in one attempt. Now as per the study, the mean time taken for insertion of LMA was 15.44 ± 2.48 seconds when compared to I-gel, in which mean time taken for insertion were 11.24 ±1.94 seconds shown in Table no.2. There was statistically significant difference between the two groups as p- value was 0.034(< 0.05).As evident from Table no.3, the groups responded to the airway instrumentation with a rise in MAP from the baseline values, reaching its peak after 15-30 seconds after airway insertion. The rise in MAP was statistically significant in both groups till 1min from baseline values but was almost similar in both groups. The p-value was significant in both groups up to 1min as compared with the baseline values (0.000 in group L and 0.004 in group I at 1 min, which is <0.05). Table 1: Comparison of number of attempts between both groups Group No. of Attempts Total P-value. I II LMA(L) 24 1 25 96.0% 4.0% 100.0% IGEL(I) 25 0 25 0.871 100.0% 0% 2.0% Total 25 25 50 100.0% 100.0% 100.0% Table2- comparison of time taken for insertion (seconds). Group Time Taken (sec.) Mean SD P-value. LMA(L) 15.44 2.48 IGEL(I) 11.24 1.94 0.034 Table 3: variation of mean arterial pressure (mmhg) values among the patients in both the group LMA(L) IGEL(I) Mean SD p-value Mean SD p-value MAP BL 93.40 10.69 N/A 94.00 7.39 N/A MAP - IAI 98.48 10.62 0.000 97.88 6.60 0.000 MAP - 1 Min. 96.76 10.89 0.000 97.44 7.34 0.004 MAP - 3 Min. 90.44 10.06 0.067 94.12 6.05 0.900 MAP - 5 Min. 87.72 9.71 0.087 92.68 6.44 0.197 MAP - 10 Min. 85.80 8.68 0.342 92.60 5.96 0.100 MAP - 15 Min. 84.35 7.94 0.007 92.40 5.40 0.105 V. Discussion Supraglottic airway devices (SGAD) have been modified in various ways following the overwhelming success of the laryngeal mask airway (LMA). They are being increasingly used each day and now considered the choice devices for airway management in majority of the cases.the advantages of classic LMA(C-LMA) are hemodynamic stability at induction and emergence, reduced anaesthetic requirements for airway tolerance, lower frequency of coughing during emergence and a lower incidence of sore throat. The disadvantages are increased risk of gastric insufflation, gastroesophageal reflux, aspiration of regurgitated gastric contents and displacement of the cuff. This led to the development of I-Gel, which is a non-inflatable device made of a thermoplastic elastomer with a gastric channel in it. DOI: 10.9790/0853-1610133943 www.iosrjournals.org 41 Page

The analysis of our observational data reveals that a statistically significant rise in pulse rate to 85.96 ±8.49 b/min (4.27 % ±4.93) from baseline value of 82.44 ±8.93 b/min Group-L and 88.20 ±8.54 b/m(4.06 % ±2.84) from the baseline value of 84.76±8.79 b/m in Group-I, was observed after insertion of the airway ( p- value <0.05 in both Group-L and Group-I), but it lasted for 15-30 seconds in both groups. As evident from the Table 3, the groups responded to the airway instrumentation with a rise in mean arterial pressure (MAP) from baseline values, reaching its peak after 15-30 seconds after airway insertion. The rise in MAP was statistically significant in both groups up to 1 min from baseline (BL) values but was almost similar in both groups. The rise was 98.48± 10.62 mmhg (BL 93.40 ±10.69) in Group-L while it was 97.88 ±6.60 mmhg (BL 94.00± 7.39) in Group-I (p-value=0.000). On comparing MAP between pre-airway manipulation and post-airway manipulation period, the percentage rise was 5.44± 9.65% in Group-L and 4.13 ±10.69 % in Group-I, almost similar in both groups. The regular occurrence of pressor responses associated with laryngoscopy and tracheal intubation, to achieve airway control has been bothering anesthesiologists.the hemodynamic responses manifesting as increase in heart rate and blood pressure are due to reflex sympatho-adrenal discharge provoked by epilaryngeal and laryngotracheal stimulation as studied by Devault et al (1960).Devault et al 3 said that mechanical stimulation by pressure of laryngoscopy on the soft tissue was probably the major factor in producing stress response to laryngoscopy and tracheal intubation, and it was later supported by other workers like Davidson 4 (1968); Shribman 5 (1987), Prys Roberts et al 6 (1971). Although in majority of patients undergoing anaesthesia these responses are transient and of little consequence but they may be harmful to patients with myocardial and cerebrovascular diseases.in our study we found both LMA Classic and I-gel airway are better than endotracheal tube as they are associated with less hemodynamic changes which are manifested by the rise in pulse rate, blood pressure and mean arterial pressure. Also both the devices are easy to insert and first attempt success rate is very high in both the groups irrespective of the anesthesiologists experience when comparing with endotracheal intubation. In our study success rate in first attempt was comparable between two groups. The success rate of insertion in first attempt in Group-L (LMA) was 96 % as compared to 100 % in Group-I (I-Gel). One patient required two attempts for insertion of LMA as the seal was not proper as suggested by air leak. This is in accordance with the prospective observational study conducted by Richetz et al 7 (2008) in 71 ASA physical status I-II female patients scheduled for gynecologic surgery, I-gel was evaluated as a supraglottic airway device.also in our study, mean time taken for insertion of LMA was 15.44 ± 2.48 sec as compared to I-gel in which mean time taken was 11.24 ±1.94 sec and there was statistical significant difference in two groups as p-value =0.034. Even time taken to insert I-gel was less than LMA.Our results also corroborates with Helmy et al 8 who corned out a prospective randomized clinical trial to compare I-Gel and C-LMA among 80 patients undergoing different surgical procedures under general anaesthesia with spontaneous ventilation. It was concluded that both I-gel and C-LMA did not cause any significant alterations in the hemodynamic status of the patients, end tidal CO 2 and SPO 2. The mean duration of insertion attempts was 15.62± 4.9 sec in I-gel group, while it was 26.2±17.7 sec in LMA group(p=0.0023). The postoperative complications were not significantly different except nausea and vomiting which was statistically higher in C-LMA group (p=0.032). Insertion of I-gel was significantly easier and more rapid than insertion of C- LMA. The leak pressure was significantly higher with I-gel than C-LMA and incidence of gastric insufflation was lower with I-gel. A comparison of I-Gel and classic LMA insertion in manikins by experienced and novice physicians was done by Stroumpoulis K etal 9 to assess the use of laryngeal mask airway (LMA), classic LMA (C-LMA) and the I-Gel. Insertions were performed using a size-4 C-LMA and I-Gel respectively. The primary endpoints were success rate for each device and duration of the insertion attempt. Secondary endpoint was the perception of ease of use with each device from experienced and novice anesthesiologists. First attempt success rate was 90.5% for I-Gel and 63.8% for C-LMA (P<0.001). I-Gel use reduced insertion times (13.32±4.99 s vs. 17.99±6.87 s, P<0.001) and was related with significantly higher first attempt success rates than C-LMA (90 vs. 48.3%, P<0.001). In addition, I-Gel use provided almost equal success rates for experienced and novice (91 vs. 90%, P=not significant), whereas C-LMA use resulted in significantly lower success rates for novices (48.3 vs. 80.4%, P<0.001). So they conclude that both the devices are easy to insert but I-Gel is slightly better than C- LMA in ease of insertion. VI. Conclusion Hence we conclude that both LMA and I-gel airway are easy to insert, maintains ventilation well intraoperatively, better alternate to endotracheal intubation as they cause minimal hemodynamic changes, and also associated with low incidence of any postoperative complications.but I-gel airway is better than Classic- LMA as it takes less time for insertion and is associated with less incidence of pharyngolaryngeal complications. DOI: 10.9790/0853-1610133943 www.iosrjournals.org 42 Page

Reference [1]. Brain AJ, the laryngeal mask a new concept in airway management. Br. J Anaesth 1983; 55: 801-805. [2]. Brimacombe JR., Berry AM ;The Laryngeal Mask Airway. In: The Difficult Airway I. AnaesthesiolClin N Am June 1995; 13(2): 411-37. [3]. Devault M, Greifenstein FE, Harris LG: Circulatory responses to endotracheal intubation in light general anaesthesia. Anaesthesiology 1960; 21:360. [4]. Davidson S: Principles and practice of Medicine 1991, 9 TH edition P1142.Edinbourgh :Livinston. [5]. Shribman AJ, Smith G, AcholaKJ ;Cardiovascular and Catecholamine responses to laryngoscopy with and without tracheal intubation. Br J Anaesth. 1987;59:259-299. [6]. Prys RobertsC, Greene LT,Meloche R, Foex P:Studies of anaesthesia in relation to hypertension and endotracheal intubation. Br J Anaesth 1971; 43: 531-47. [7]. Richetz B, Saltel L, Banchereau F, Toriell, Cross AM; A new single use supraglottic airway device with a non-inflatable cuff and an oesophageal vent:an observational study of the I-gel. AnaesthAnalg 2008; 106:1137-9. [8]. Helmy A M, Atef H M,Taher et al ; Comparative study between I-gel, a new supraglottic airway device, and classical laryngeal mask airway in anaesthetized spontaneously ventilated patients. Saudi J Anaesth2010 ; 4:131-6. [9]. Stroumpolis K et al : Comparison of I-gel and Classic LMA in manikins by experienced and novice physicians. Br J Anaesth 2004;88: 584-7. [10]. Shin WJ etal; The supraglottic airway I-gel in comparison with ProSeal laryngeal mask airway and classic laryngeal mask airway in anaesthetized patients.eur J Anaesth 2010 Jul;27(7) :598-601. [11]. Uppal V, Fletcher G et al; Comparison of I-gel with the cuffed tracheal tube during pressure-controlled ventilation. Br J Anaesth2009 ;102(2):264-8. [12]. Francksen H, Renner J, Hanss R, Scholz J, Doerges V, Bein B; A comparison of the I-gel with the LMA-Unique in non paralyzed anaesthetized adult patients. Anaesth 2009;64:1118-24. [13]. B.Gibbison Cook and C. Seller ;Case series: protection from aspiration and failure of protection from aspiration with the i-gel airway. Br J Anaesth 2008; 100: 415 17. [14]. Bukhari S A, I Naqash, Zartgar J,Nengroo S and Waheed A Mir; Pressor responses and intraocular pressure changes following insertion of laryngeal mask airways: comparison with tracheal tube insertion: Indian J Anaesth 2003,47: 473-475. [15]. S. Sharma, R. Rogers et al. The i-gel airway for ventilation and rescue intubation. Anaesthesia2007;62: 419-420. *Dr Manoj Tripathi. " Comparisonof Classic- Laryngeal Mask Airway with I-Gel Airway,during Anaesthesia with Controlled Ventilation in Routine Surgical Procedures." IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) 16.10 (2017): 39-43 DOI: 10.9790/0853-1610133943 www.iosrjournals.org 43 Page