Warranty. Any attempt by an unauthorized person to alter or repair the product is also not covered by the warranty.

Similar documents
Automated ultrasonic testing of submerged-arc welded (SAW) pipes using phased-arrays

MA 25 Operating Manual

Ultrasonic Thickness Procedure Pulse-Echo Thickness Gage TABLE OF CONTENTS. 1.0 Introduction Reference Documents Summary of Practice 2

CE Columns and Accessories

VISTA400 REMOVABLE FOOT PLATE. Instructions For Use. Step on yellow pedals to close and open legs to go around chairs & ambulate.

Fibrlok II 2529 Universal Optical Fiber Splice

Pipeline Technology Conference 2007

Fibrlok II 2529 Universal Optical Fiber Splice

Instructions. Fibrlok Optical Fiber Splicing System. Issue 6, August 1991

Diffractive Optic Elements (DOE)

TABLE OF CONTENTS 1.1. WARRANTY DAMAGED SHIPMENTS SERVICE INTRODUCTION UNPACKING AND INSTALLATION

IMPORTANT SAFETY INSTRUCTIONS

Instructions. Fibrlok II Optical Fiber Splicing System. Issue 1, June 1992

Operating Instructions MA 25

Activated Transponder & Activator Instruction Manual

Goniometer series 400

Instructions for Use Reprocessed Ethicon ENDOPATH XCEL TM Bladeless Trocar with OPTIVIEW Technology

Convex Array Transducer

Real Time 2D Ultrasound Camera Imaging: A Higher Resolution Option to Phased Array Bob Lasser Randy Scheib Imperium, Inc.

StrataCooler Cryo Preservation Module and StrataCooler Cryo Lite Preservation Module

USER S MANUAL QUESTIONS? CAUTION. Visit our website at.

AVANT Audiometer Manual Rev. 2 Effective 10/05

OWNER S MANUAL. Quick Insertion Guide: INSERT EARTIP into ear canal and rotate earpiece backwards & into position CHECK FOR SEAL

Multipower. User Guide E S S E N T I A L S T R E N G T H

Employer s Unit of Competence Ultrasonic testing of materials, products and plant

ER75 Electro-Acoustic Ear Simulator. Operating Manual

Model 9306A Six-Jet Atomizer

Contents Safety Instructions... 4 Package Contents... 6 Notes on Measurements... 7

Nuclear Associates

C200 bands are available in a variety of colors. Visit us at LifeTrakUSA.com

Computer T4.2 IWM. COMPUTER MANUAL Reebok T

Dip Station G

Successful Splicing Made Easy

Ultra View Manual Rev. 2 Effective 7/05

AquaJogg Hydro Treadmill

TECH 2 Dew Point Retrofit Kit

CRACK DETECTION AND PIPELINE INTEGRITY SOLUTIONS

Convex Array Transducer

User Manual.

Tetracycline Plate Kit (for Honey) PN 52254B


OPTICAL FIBER SPLICING. Courtesy from Significant Technologies Sdn Bhd

Sag Shoe Assembly. Instruction Manual # Updated 10/19/2017 Ver. 2.0

LET OUR IMAGE ENHANCE YOUR IMAGE. Operating Instructions MedRx Video Portable OtoScope System

Quick Start Guide. Congratulations on your journey to better hearing

WARNING To reduce the risk of burns, fire, electric shock, or injury to persons:

User Manual Table of Contents. Instructions for Using the LaserTouchOne Charging the Unit... 5 Holding the Device... 5 Treatment Steps...

INSTALLATION MANUAL. VIDEO Camera, Probe and Lightsource OTOSCOPES.

P/N: Rev B (10/09/2006) SelectTech 3.1 Bench Assembly/Owner s Manual

High Frequency Linear Array Transducer

FURNITURE TERMS / POLICIES. TERMS OF FURNITURE SALE [agreement is required with all orders] FURNITURE ORDERS

AS Medizintechnik GmbH Sattlerstraße Tuttlingen Germany

BRS GM100 Glucose Monitoring System. User Instruction Manual Ver. 3.5

w. D. Jolly, F. A. Bruton, and C. Fedor

APEX FLAT BENCH JD 2.1

Filament Fusion Splicing Workstation

Scrotal. and. User Guide

PHM-100 PORTABLE HANDHELD TRANSDUCER INDICATOR OPERATORS MANUAL. Transducer Techniques R

COMBINED APPLICATION OF ULTRASONIC INSPECTION AND ACOUSTIC EMISSION MONITORING FOR EVALUATION OF FRACTURE CRITICAL MEMBERS IN RAILWAY BRIDGES.

IPC-6018A. Microwave End Product Board Inspection and Test IPC-6018A. A standard developed by IPC. Supersedes IPC-6018 January 1998

Operation Manual. Screening Audiometer AS608/AS608e

Contents of the Prodigy Pocket. Meter. PRODIGY Owner s Manual PRODIGY Owner s Manual

OPERATING INSTRUCTIONS. Orascoptic DK

Flexi-Needles. BMI_FLEXINEEDLES_v2 web

WARNING To reduce the risk of burns, fire, electric shock, or injury to persons:

Medescan Nebuliser Med - S600A Instructions Manual

6. Gear Measurement And Testing

Adventure 3 Plus Service Manual

White Paper Selecting the Correct Fusion Splicer for Your Application By: Keith Foord, Product Manager, Greenlee Communications

USER S MANUAL QUESTIONS? CAUTION. Visit our website at. new products, prizes, fitness tips, and much more!

MARCY DIAMOND ELITE UTILITY BENCH MD-440. Model MD-440. Retain This Manual for Reference OWNER'S MANUAL

GEX Recommended Procedure Eff. Date: 07/27/07 Rev.: C Pg. 1 of 10

Model 380B DNA Synthesizer Version 1.1

Capacitive Sensors 17

Routine Quality Assurance Cookbook

THE RIGAKU JOURNAL VOL. 23 / 2006, A1-A10 CONSIDERATIONS REGARDING THE ALIGNMENT OF DIFFRACTOMETERS FOR RESIDUAL STRESS ANALYSIS

INSTRUCTIONS FOR USE AND CARE

STANDARD INDOOR SIGNS INSTRUCTION MANUAL REVISION DATE: PART#:

Calibration and Checking

Quick Start Guide. Congratulations on your journey to better hearing

8 Performing Medical Procedures

Ultrasonic Phased Array Testing of Complex Aircraft Structures

Technique Guide. SureLock Distal Targeting Device. C-arm guided targeting for trochanteric fixation nail.

TRAINING MANUAL AVANT HIT+ Hearing Instrument Test Chamber.

EXERTEC FLAT BENCH ETC-2.1. Model ETC-2.1. Retain This Manual for Reference OWNER'S MANUAL IMPEX INC.

APPLICATION AND DEPLOYMENT OF ADVANCED NDE TECHNIQUES IN HIGH PRESSURE VESSELS

USER S MANUAL CAUTION ACTIVATE YOUR WARRANTY CUSTOMER CARE. Model No. WEBE Serial No.

Linkam Scientific Instruments

Midwest E Motor. Directions For Use. Doc. No

P/N: Rev B (10/03/2006) SelectTech 5.1 Bench Owner s/assembly Manual

Rat Hemoglobin A1c (HbA1c) Kit Instructions

Quality. Elegance. Innovation.

ULTRASOUND IMAGING EE 472 F2018. Prof. Yasser Mostafa Kadah

Developments in Ultrasonic Inspection II

Transcription:

Warranty ii The Gentec-EO inc Holographic Beam Sampler carries a one year warranty (from date of shipment) against material and / or workmanship defects, when used under normal operating conditions. The warranty does not cover damages related to misuse. Gentec-EO inc will repair or replace, optionally, any product which proves to be defective during the warranty period, except in the case of product misuse. Any attempt by an unauthorized person to alter or repair the product is also not covered by the warranty. The manufacturer is not liable for consequential damages of any kind. In the case of a malfunction, contact the local Gentec-EO inc distributor or the nearest Gentec-EO inc office to obtain a return authorization number. The material should be returned to: Gentec Electro-Optics, Inc. 445, St-Jean-Baptiste, Suite 160 Québec, Qc Canada G2E 5N7 Tel: (418) 651-8003 Fax: (418) 651-1174 e-mail: service@gentec-eo.com www.gentec-eo.com

TABLE OF CONTENTS iii WARRANTY... ii TABLE OF CONTENTS... iii LIST OF ILLUSTRATIONS... iv 1 GENERAL INFORMATION... 1 1.1 RECEPTION... 1 1.2 INTRODUCTION... 2 HBS STANDARD SPECIFICATIONS... 3 HBS SUBSTRATES... 3 HBS CUSTOMIZED SPECIFICATIONS... 4 2 HBS SETUP AND ALIGNMENT... 5 3 BEAM PROFILING... 7 4 MAINTENANCE... 9 DAMAGE TO THE MATERIAL... 10

LIST OF ILLUSTRATIONS iv Fig. 2-1 HBS Alignment... 6 Fig. 3-1a Cos narrowing effect... 8 Fig. 3-1b Camera setup... 8 Fig. 3-1c Second order used for beam profiling... 8

1 1 GENERAL INFORMATION 1.1 RECEPTION The Gentec-EO inc HBS equipment was delivered in good condition. Once the shipment is received, it should be immediately inspected for damage. The contents of all boxes should be unpacked carefully. Notify and file a claim with the carrier in the case of any loss or damage. All shipping boxes must be inspected by the carrier in order to file a claim. Send a purchase order to Gentec-EO inc in order to replace any parts damaged during shipment. The amount indicated on the replacement part invoice can then be collected from the carrier.

2 1.2 INTRODUCTION The HBS offers an unprecedented range of applications for users of both low and highlasers. Its extraordinary versatility allows to: power - obtain multiple, spacially representative beam samples - perform sampling in real time - monitor on-line power/energy - measure wavelengths - perform output coupling - measure pulse width - measure temporal pulse shape - obtain near-field and far-field measurements on the same pulse - analyze beam profile - analyze beam quality - gather information on beam spectral content The HBS is actually a diffraction grating that produces three useful pairs of transmitted orders symmetrically disposed with respect to the main beam. First order samples are fully calibrated to indicate the exact sampling ratio between the diffracted and transmitted beams. This ratio is indicated on the top of the HBS handling box. Characterization of the second order sampling ratio can be performed upon request. No characterization is available for third and higher orders. The second order samples are produced at +/- 20 from the zero order beam (transmitted main beam) for standard HBS models, when the beam to be sampled is at normal incidence on the HBS input surface.

3 HBS STANDARD SPECIFICATIONS First Order Second Order 1/100 or 1/2000 of transmitted beam (Calibration accuracy = ± 3%) Characterization upon request Order Angles 1st = 10 2nd = 20 Coating Anti reflection on both sides Insertion Loss (with AR coating) 0.3% per side (typical) HBS SUBSTRATES SUBSTRATE UV-Grade Fused Silica Zinc Selenide DIAMETER 1" and 2" (+ 0/-.005") 1" (+ 0/-.005") (inches) THICKNESS 0.125" (+/-.005") 0.125" (+/-.005") (inches) WEDGE 30 min. (+/- 10 min.) 30 min. (+/- 10 min.) SURFACE FINISH Erreur! Signet non défini./4 @ 1.064 µm (2 sides) Erreur! Signet non défini./4 @ 1.064 µm (2 sides) SCRATCH/ DIG BEVEL (inches) 20-10 (2 sides) 20-10 (2 sides) 0.020" (+/-.005") at 45 0.020" (+/-.005") at 45

4 HBS CUSTOMIZED SPECIFICATIONS (call Gentec-EO inc for details) Gentec-EO inc HBS custom engineered models may contain any of the following specifications: - Wavelengths from 250 to nm to 14 µm. - Sampling factor from 1/10 to 1/2000 of transmitted energy and power on first order samples. - Any sampling angle for the first order samples (second order deviation angle will be twice as large as the angle chosen for the first order). - Substrates with or without wedge. - Anti reflection coating on incident surface to minimize loss, or more reflective coating if required for application. - Anti reflection coating on transmitting surface (it is strongly recommended to purchase an uncoated unit and apply required coating).

5 2 HBS SETUP AND ALIGNMENT Normal Incidence Setup The relation between the incidence angle upon the HBS and the angles where the secondary beams are diffracted is determined by the properties associated with the general theory on gratings. In order to obtain the specified secondary beams (angles, sampling ratio), it is recommended to place the HBS at normal incidence with respect to the beam to be sampled. Alignment In order to avoid multiple parasitic diffracted orders between the HBS surfaces, the grating surface must be placed as the output surface. All beams are diffracted within the same plan. The plan's normal axis is parallel to the direction of the lines engraved in the substrate. By turning the HBS around its perpendicular axis, the diffracted orders turn accordingly and always within the same plan (see Fig. 2-1). Because of the standard substrates' weak wedge, the zero order is slightly deviated with respect to the incident axis. By turning the HBS in the above manner, the zero order should also slightly turn, especially when observed at a great distance from the alignment point.

6

7 3 BEAM PROFILING HBS for Beam Profiling Purposes In order to use the HBS for imaging a collimated beam, a special procedure is recommended. This setup is related to the fact that there exists a geometrical narrowing of the diffracted beam when viewed from a right angle in relation to its propagation direction. The beam will be slightly elliptical (see Fig. 3-1a ). The following equation should be used to correct the beam profiling: d m = d o cos Erreur! Signet non défini. For example, if the second order is used, the diameter measured in the diffractive plan reduced to; will be d 2 = d o x 0.94 To overcome this effect, the camera's (or profiler's) perpendicular axis should be placed (turned) parallel to the HBS perpendicular axis (Fig. 3-1b). Another simple method may be used to avoid elliptical narrowing: by turning the HBS 10 from the incident beam, one of the second orders will be geometrically identical to the incident beam. First orders may still be used for energy/power monitoring (Fig. 3-1c). For more details, contact the nearest Gentec-EO inc agent or representative.

8

9 4 MAINTENANCE In order to obtain maximum efficiency from the HBS, both surfaces must be kept clean and free of dust and/or oil. NEVER TOUCH SURFACES WITH BARE HANDS. Dust can be removed with a clean stream of air. For removing dirt or oil, it is recommended to: 1) use (if available) an ultrasonic bath or; 2) rinse both sides with spectrophotometric grade methanol or isopropanol to remove particles and complete cleaning with the drop and drag technique, using a soft lint free lens tissue with spectrophotometric grade methanol or isopropanol. Avoid using acetone, as it may leave stains or residues on the HBS surface if not used properly. If these cleaning methods are not sufficient to remove contamination from your HBS, contact the nearest Gentec-EO inc agent or representative.

10 DAMAGE TO THE MATERIAL Damage to the material can be caused by using the HBS when the surface has been contaminated. Tests conducted at three different wavelengths (355 nm, 532 nm and 1.064 µm) by a major US- Government-funded laboratory indicated that the HBS has the same damage threshold as the bare substrate itself.