LAB5 EDITION 2 NOVEMBER 2012

Similar documents
UKAS Guidance on the Application of ISO/IEC Dealing with Expressions of Opinions and Interpretations

Drug Treatment Centre Board

Proficiency Testings (PTs) and Interlaboratory Comparisons (ILCs) for the Department of Calibration Laboratories

PROFICIENCY TESTING AND OTHER COMPARISON PROGRAMME REQUIREMENTS FOR CALIBRATION LABORATORIES

Testing Railway Safety Critical Workers for Drugs and Alcohol

IAS Presentation at Kuwait Labs nd Kuwait Conference for Laboratory Quality and Accreditation Empowering Laboratory Personnel

Testing Railway Safety Critical Workers for Drugs and Alcohol

Assurance Engagements Other Than Audits or Reviews of Historical Financial Information

Proficiency Testing Policy

National Voluntary Laboratory Accreditation Program

Medical Bureau of Road Safety

Airmid Health Group Limited t/a Airmid Health Laboratory

Medical Bureau of Road Safety

Sterilization of health care products Radiation. Part 3: Guidance on dosimetric aspects of development, validation and routine control

SEG s Final Draft THE ORGANISATION OF THE ISLAMIC CONFERENCE (OIC) GUIDELINES FOR THE HALAL ACCREDITATION BODY ACCREDITING HALAL CERTIFICATION BODIES

Dairygold Co-Op Society Limited Dairygold Feed Laboratory

IAF Mandatory Document. Requirements for the Migration to ISO 45001:2018 from OHSAS 18001:2007 (IAF MD 21:2018)

Withdrawn at December 31, Guideline DKD-R 6-2. Calibration of Measuring Devices for Vacuum DEUTSCHER KALIBRIERDIENST. Part 1.

Eurofins Food Testing Ireland Limited

Certificate of Accreditation to ISO/IEC 17025:2005

Approval of Dosimetry Services in Ireland Guidelines for Applicants

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Test Report To AS/NZS :1998 in conjunction with AS/NZS :2003. Report No. T140218_SA

LAS-Q008. Proficiency Testing Requirements for Testing and Calibration Laboratories

Alpha Analytical Services Ltd

The Practice Standards for Medical Imaging and Radiation Therapy. Sonography Practice Standards

IMPLEMENTATION COURSE (MODULE 1) (ISO 45001:2016 AVAILABLE ON REQUEST) COURSE DURATION: 3 DAYS FOR OHSAS 18001:2007 OR ISO 45001:2016

IAASB Main Agenda (March 2005) Page Agenda Item. DRAFT EXPLANATORY MEMORANDUM ISA 701 and ISA 702 Exposure Drafts February 2005

ISO and the Delivery of Competent NDT Services

Policy for Participation in Proficiency Testing Activities

INTERNATIONAL STANDARD ON ASSURANCE ENGAGEMENTS 3000 ASSURANCE ENGAGEMENTS OTHER THAN AUDITS OR REVIEWS OF HISTORICAL FINANCIAL INFORMATION CONTENTS

COMPETENT AUTHORITY (UK) MEDICAL DEVICES DIRECTIVES GUIDANCE NOTES FOR MANUFACTURERS OF DENTAL APPLIANCES

ISO/TR TECHNICAL REPORT. Non-destructive testing Guidelines for NDT personnel training organizations

ISO INTERNATIONAL STANDARD

About NATA and GLP recognition. Information on the OECD Principles of Good Laboratory Practice compliance monitoring program

Assurance Engagements Other than Audits or Review of Historical Financial Statements

International Framework for Assurance Engagements

Comparability and quality of experimental data under different quality systems. S. Caroli Istituto Superiore di Sanità Rome

Trademark Use Guidelines for Certified Products and Related Advertising

Developments in IAF/PAC/ILAC/APLAC/ISO. Anil Jauhri CEO, NABCB

Page 1 of 7 Pages Weight ID Number 12345A Certificate Number SECTION 1: NAME AND ADDRESS OF CUSTOMER Date of Calibration 15-MAY-2018

CERTIFICATE OF CALIBRATION

Multi Analyte Custom Grade Solution

Length: 507 mm Width: 581 mm Height: 854 mm. Materials: Frame: Ø16 mm metal tubes Shell: 6 mm plastic

Memorandum of Understanding between the Care Quality Commission and the General Dental Council

INTERNATIONAL STANDARD ON AUDITING (NEW ZEALAND) 530

3135th JUSTICE and HOME AFFAIRS Council meeting Brussels, 13 and 14 December 2011

Exposure Draft, ISA 720 (Revised) The Auditor s Responsibilities Relating to Other Information

Seal of Approval Guidelines. The Approval Program

Appendix I. List of stakeholders consulted with on the Patient Radiation Protection Manual and members of the Medical Exposure Radiation Unit

Texasmutual.com 844-WORKSAFE ( ) January 2016 Worksafetexas.com 1

COMMISSION OF THE EUROPEAN COMMUNITIES REPORT FROM THE COMMISSION TO THE COUNCIL AND THE EUROPEAN PARLIAMENT

2018 CDC VFC Compliance Visit Requirements & Recommendations

Auditing Standards and Practices Council

NANDTB-F012 Rev 0 Audit Checklist

LEAF Marque Assurance Programme

RPL Form Certificate IV in Fitness SIS40215

IAASB Exposure Draft, Proposed ISAE 3000 (Revised), Assurance Engagements Other Than Audits or Reviews of Historical Financial Information

PHYSIOTHERAPY ACT AUTHORIZATION REGULATIONS

40 CFR PART DENTAL OFFICE POINT SOURCE CATEGORY

C 178/2 Official Journal of the European Union

TG Approved By: SANAS Page 1 of 6

Specific Accreditation Guidance OECD GLP

EFNDT Guidelines on the overall NDT quality system in Europe

a practical guide ISO 13485:2016 Medical devices Advice from ISO/TC 210

Guidance for the Communication of Clinical and Imaging Observations and Procedure Details by Radiologist Assistants to Supervising Radiologists

Please find enclosed Dosimetry Service Licence No which replaces Dosimetry Service Licence No

References to people who are obese in weight loss advertising

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

EER Assurance Criteria & Assertions IAASB Main Agenda (June 2018)

Guide to Fulfillment of Measurement Uncertainty

Quality, Safety and Sourcing in Unlicensed Medicines

CERTIFICATE OF ANALYSIS. tel: fax:

SHIRE v FERRING. Promotion of Pentasa CASE AUTH/2299/2/10

General concepts in the Ph. Eur.: theory and rationale

Organisation Internationale de Métrologie Légale

THE RESPONSIBLE PHARMACIST REGULATIONS

OHSAS Project Group. Implementation Guidance for migrating from OHSAS 18001:2007 to ISO 45001:2018 CONTENTS 1.0 INTRODUCTION

Guidelines on the Sourcing of Medicinal Products for Sale or Supply by a Retail Pharmacy Business

PCN-ISO GEN Requirements for the Qualification of personnel for Limited Applications of Non-destructive Testing

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

IPC Athletics. Classification Rules and Regulations

Chemotherapy Training and Assessment Policy. For Medical Prescribers and Pharmacy Verifiers

INTERNATIONAL STANDARD

COUNCIL OF THE EUROPEAN UNION. Brussels, 7 September 2009 (OR. en) 11261/09 Interinstitutional File: 2008/0002 (COD) DENLEG 51 CODEC 893

Number 40 of Irish Sign Language Act 2017

Certified Reference Materials - A Path to Traceable Chemical Measurements

IPC Athletics Classification Rules and Regulations

IMPORTANT DISCLAIMER. Note

American Association for Laboratory Accreditation

Role of Countries (1)

TERMS AND CONDITIONS NATIONAL GOOD LABORATORY PRACTICE (GLP) COMPLIANCE MONITORING AUTHORITY

NEPHROCHECK Calibration Verification Kit Package Insert

COMMITTEE FOR MEDICINAL PRODUCTS FOR HUMAN USE (CHMP)

11 September Tower Old Broad Street London EC2N 1HQ United Kingdom t + 44 (0) f + 44 (0)

World-Wide Radiation Metrology: The BIPM, the CIPM MRA, and ICRU

OIML R 122 Annex C RECOMMENDATION. Edition 1999 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

Directions given under the Human Fertilisation and Embryology Act 1990 as amended. Ref: 0006 Version: 4

Transcription:

2007 LAB5 EDITION 2 NOVEMBER 2012 Reporting Calibration Results JH CONTENTS SECTION PAGE 1 Introduction 2 2 UKAS calibration accreditation symbol 3 3 General guidance for the presentation of calibration certificates 4 4 Calibration labels 7 Appendix A Reference standards on UKAS accredited calibration certificates 8 Appendix B References 9 PAGE 1 OF 9 EDITION 2 NOVEMBER 2012

1 INTRODUCTION 1.1 The general requirements that testing and calibration laboratories have to meet if they wish to demonstrate that they operate to a quality system, are technically competent and are able to generate technically valid results are contained within ISO/IEC 17025:2005 [B1]. This international standard forms the basis for international laboratory accreditation and in cases of differences in interpretation remains the authoritative document at all times. LAB5 is not intended as a prescriptive document, and does not set out to introduce additional requirements to those in ISO/IEC 17025:2005 but to provide amplification and guidance on the current requirements within the international standard. 1.2 This publication provides guidance for the format, presentation and wording of calibration certificates and calibration labels covered by the scope of a laboratory s UKAS accreditation to ISO/IEC 17025:2005. Laboratories following this guidance will be able to produce documentation that is easily identified as produced by a UKAS accredited calibration laboratory and that minimizes the risk of customers and readers being misled. 1.3 This document replaces LAB5 (Edition 1, March 2000). It also incorporates details from P11, Reference standards on UKAS accredited calibration certificates (Edition 3, June 2000), with minor amendments. P11 will continue as a separate document. 1.4 Edition 2 of LAB5 is a complete revision of the previous issue and it is impractical to list or identify all the changes in detail. Some of the more notable changes or additions are as follows: 1.4.1 Details regarding the use of the ILAC MRA Mark have been included. 1.4.2 The recommended traceability statement at the foot of the first page of the example calibration certificate has been updated to include reference to SI units. 1.4.3 The list of references to other publications has been updated. 1.4.4 Further detail has been added to paragraph 3.2 regarding reporting of uncertainty and compliance statements. 1.4.5 Further detail has been added to paragraph 4.2 regarding the use of limited calibration statements on calibration labels. 1.4.6 The overall presentation, including minor text clarifications, has been updated. PAGE 2 OF 9

2 UKAS CALIBRATION ACCREDITATION SYMBOL 2.1 The conditions for reference to UKAS accreditation on certificates and reports, including the need for clarifying statements and disclaimers when the results of non-accredited calibrations and/or opinions are reported with accredited calibrations, are given in UKAS Publication LAB1 [B2], Reference to accreditation for laboratories. Conditions specifically for use of the national accreditation symbols, including the UKAS calibration symbol, are given in BIS Publication URN 11/673 [B3]. 2.2 A calibration certificate bearing the UKAS calibration accreditation symbol is sufficient evidence of the traceability of the calibration results reported. 2.3 The ILAC MRA Mark may also be used on calibration certificates. This Mark has been registered for use with the UK Intellectual Property Office which means that UKAS can sublicense the Mark to accredited laboratories. All UKAS accredited laboratories are entitled to use the ILAC MRA Mark provided they have signed the ILAC MRA License Agreement and use the Mark as prescribed. The ILAC MRA Mark can only be used in conjunction with the relevant laboratory accreditation symbol. Further details are available on the UKAS web site. PAGE 3 OF 9

3 GENERAL GUIDANCE FOR THE PRESENTATION OF CALIBRATION CERTIFICATES 3.1 It is recommended that: (a) (b) (c) The first page of a UKAS calibration certificate is in the format shown in Figure 1 and that any continuation pages have the format shown in Figure 2. Calibration certificates are issued on A4 sized paper with the accreditation symbol at the top of the page on the left or right hand side. The date of issue appears on the certificate and that all dates are in the format day/month/year. 3.2 It is generally necessary for the interpretation of calibration results for calibration certificates to include the uncertainty of measurement and/or a statement of compliance with an identified metrological specification or clauses thereof. 3.3 In the normal case, where calibration certificates contain measurement results, there should be a statement regarding the basis on which the reported uncertainty has been evaluated. In order to meet the rules for international acceptance of certificates under the mutual recognition agreements of ILAC and EA this evaluation should be carried out according to UKAS publication M3003 [B4] or EA publication EA-4/02 [B5] and the statement should be in the form given therein, e.g., The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor k = 2, providing a coverage probability of approximately 95 %. The uncertainty evaluation has been carried out in accordance with UKAS requirements. NOTE: There may be circumstances under which a coverage factor other than 2 is required and therefore this statement will have to be modified accordingly. There are also circumstances under which the effective degrees of freedom should be reported. Examples are presented in UKAS document M3003. 3.4 In the case where compliance with specification statements are made the uncertainty of measurement should be taken into account in accordance with the methods described in UKAS publication M3003 [B4]. If compliance statements are made but results and uncertainties are omitted then there should be a written statement that describes the calibration points at which compliance is claimed. NOTE: References to compliance statements apply equally to statements of non-compliance. 3.5 A laboratory may include in its calibration certificates the following statement: UKAS is one of the signatories to the Multilateral Agreement of the European co-operation for Accreditation (EA) for the mutual recognition of calibration certificates issued by accredited laboratories. PAGE 4 OF 9

CERTIFICATE OF CALIBRATION ISSUED BY DATE OF ISSUE CERTIFICATE NUMBER 0000 Laboratory name and address Page of pages (and company logo if desired) Approved Signatory Name Signature This certificate is issued in accordance with the laboratory accreditation requirements of the United Kingdom Accreditation Service. It provides traceability of measurement to the SI system of units and/or to units of measurement realised at the National Physical Laboratory or other recognised national metrology institutes. This certificate may not be reproduced other than in full, except with the prior written approval of the issuing laboratory. Figure 1 Recommended format for the first page of a calibration certificate. PAGE 5 OF 9

CERTIFICATE OF CALIBRATION Certificate Number UKAS Accredited Calibration Laboratory No. 0000 Page of pages Figure 2 Recommended format for continuation pages of calibration certificates. PAGE 6 OF 9

4 CALIBRATION LABELS 4.1 Laboratories should apply calibration labels to measuring instruments (or, if not practicable, to the container) that they have calibrated under their accredited scope. 4.2 It is important that the label is not misleading. Therefore, if the coverage of the calibration is such that not all major parts of a metrological specification are covered with sufficient detail to give confidence in the equipment performance, the words Limited Calibration should be used. 4.3 Superseded UKAS calibration labels should be removed or cancelled. Information as suggested in paragraph 4.4 0000 Figure 3 Example design for calibration labels 4.4 The following information should be indelibly inscribed on the label by the laboratory that has performed the calibration: (a) (b) (c) (d) (e) (f) UKAS accreditation symbol, including the accreditation number of the calibration laboratory; Instrument identification; Date of calibration (with the month stated as a word); Certificate number; Space for the date when calibration is again due, e.g. Recalibration due (date to be inserted by the customer unless the calibration laboratory has been instructed to insert this by the customer or if required by legal regulations); If desired, the name of the calibration laboratory. 4.5 A suggested format and design for calibration labels is shown Figure 3. PAGE 7 OF 9

APPENDIX A REFERENCE STANDARDS ON UKAS ACCREDITED CALIBRATION CERTIFICATES A1 A2 A3 A4 A5 A6 A7 The purpose of this Appendix is to assist accredited laboratories, or their customers, with the discussions they may have with assessors from certification bodies and others about the content of calibration certificates. Difficulties may occur because assessors sometimes wish to see details of the reference standards used for calibration included on UKAS accredited calibration certificates (i.e. those bearing the UKAS calibration symbol). Any calibration laboratory that holds UKAS accreditation has to operate in accordance with ISO/IEC 17025:2005 and UKAS requirements. These requirements apply not only to the calibrations for which the laboratory offers a service, but also to all subsidiary measurements (for example, of environmental conditions) whose accuracy may significantly affect the accuracy or validity of such calibrations. The laboratory is required to have procedures for carrying out the calibrations and for the management and calibration of its reference standards of measurement and other measuring equipment. To satisfy these requirements, laboratories must hold all of the appropriate reference standards of measurement that they need, and maintain them in an appropriate state of calibration to ensure traceability of measurement results. Furthermore, accredited laboratories are required to comply with other technical requirements, such as the effective training of staff, the need for a suitable environment, the adherence to technically valid procedures, the requirements for quality control, record keeping, interlaboratory comparisons and the like. A list of equipment in a calibration certificate does not demonstrate that such requirements are sufficiently addressed. UKAS assessment visits do confirm that the above requirements are being satisfied. There is therefore no need for accredited calibration certificates to provide details of the equipment used, since UKAS calibration laboratory accreditation provides all the assurances that the user needs. There may, however, be technical reasons when it might be necessary to include information about the equipment used within a calibration certificate. These may include: (a) (b) Circumstances when the calibration data are entered directly into the certificates, either manually or automatically, and the certificate becomes the only record of the calibration; Situations when the nature of the equipment used has direct relevance to the results and a description is needed to properly interpret those results. PAGE 8 OF 9

APPENDIX B REFERENCES B1 B2 B3 B4 B5 CEN/CENELEC, ISO/IEC 17025:2005, General requirements for the competence of testing and calibration laboratories, May 2005. United Kingdom Accreditation Service, LAB1, Reference to Accreditation for Laboratories, Edition 5, August 2009. Department for Business Innovation & Skills, URN 11/673, Conditions for Use of the National Accreditation Logo and Symbols by UKAS and UKAS Accredited Organisations, July 2009. United Kingdom Accreditation Service, M3003, The Expression of Uncertainty and Confidence in Measurement, Edition 3, November 2012. European cooperation for Accreditation, EA-4/02 Expression of the Uncertainty of Measurement in Calibration, December 1999. PAGE 9 OF 9