A Review of the Effectiveness of Otoacoustic Emissions for Evaluating Hearing Status After Newborn Screening

Similar documents
The clinical Link. Distortion Product Otoacoustic Emission

Improving the diagnostic power of otoacoustic emissions. Arturo Moleti Physics Department University of Roma Tor Vergata

Otoacoustic Emissions As A Test Of Noise-Induced Hearing Loss. Brenda L Lonsbury-Martin PhD

mously with greater accuracy for mid and high frequencies, compared to the accuracy that is achieved at lower frequencies.

Audiological Diagnosis after Newborn Screening

FALSE POSITIVE DP GRAMS

Technical Report: Distortion Product Otoacoustic Emissions That Are Not Outer Hair Cell Emissions DOI: /jaaa

OtoAcoustic Emissions (OAE s)

Emissions are low-intensity sounds that may be detected in the external ear canal by a microphone

Advanced. NEW! Four times faster DPOAE: concurrent measurement of both ears while recording two DPs simultaneously in each ear!

I. INTRODUCTION. J. Acoust. Soc. Am. 111 (1), Pt. 1, Jan /2002/111(1)/271/14/$ Acoustical Society of America

Advanced otoacoustic emission detection techniques and clinical diagnostics applications

Wheeler, K.S. M.Cl.Sc. (Aud) Candidate School of Communication Sciences and Disorders, U.W.O

Clinical applications of otoacoustic emissions in Industry. Prof. Dr. B. Vinck, MSc, PhD University of Ghent, Belgium

Educational Module Tympanometry. Germany D Germering

Plural Publishing Newsletter Spring Otoacoustic Emissions (OAEs): A 30-Year Perspective. James W. Hall III, Ph.D. University of Florida

Trajectory of the Aging Cochlea

Introduction. IAPA: June 04 1

(OAEs) for. Steven D. Smith, Au.D.

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Application of a Stimulus Spectral Calibration Routine to Click Evoked Otoacoustic Emissions

A Guide to. Otoacoustic Emissions (OAEs) for Otolaryngologists.

Hearing loss can muddy the waters of otologic disease detection

But, what about ASSR in AN?? Is it a reliable tool to estimate the auditory thresholds in those category of patients??

A Guide to. Otoacoustic Emissions (OAEs) for Physicians.

Neuro-Audio Version 2010

ABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE VEMP ECochG MLR P300

CE-Chirp. Making ABR fast, accurate and clear! Stimulus Family

(Otoacoustic Emissions and Automated ABR)

first described by Starr 1996 as a subgroup of patients with

KANSAS GUIDELINES FOR INFANT AUDIOLOGIC ASSESSMENT

Comparison of Distortion Product Otoacoustic Emission Amplitude between Normal Hearing Male and Female Subjects

James W. Hall III, Ph.D.

AUDL GS08 and GAV1: 2013 Final exam page 1/13. You must complete all sections. Label all graphs. Show your work!

Hearing Screening, Diagnostics and Intervention

(OAEs) for. Physicians. Steven D. Smith, Au.D.

Signals, systems, acoustics and the ear. Week 5. The peripheral auditory system: The ear as a signal processor

More robust estimates for DPOAE level at audiometric frequencies

Synaptopathy Research Uwe Andreas Hermann

Outline ANATOMY OF EAR. All about Cochlear implants/why does this child not have a Cochlear Implant?

THRESHOLD PREDICTION USING THE ASSR AND THE TONE BURST CONFIGURATIONS

OAE Test System. Screener PLUS. Diagnostic PLUS. with 4 frequency DPOAE testing Protocols

The Verification of ABR Response by Using the Chirp Stimulus in Moderate Sensorineural Hearing Loss

Physiological basis of sound design. Prof. Dr. med. Eckhard Hoffmann Dipl.-Ing. (FH) Steffen Kreikemeier Aalen University of Applied Sciences

Sources and Mechanisms of DPOAE Generation: Implications for the Prediction of Auditory Sensitivity

Role of Distortion Product Otoacoustic Emissions (DPOAES) In Detecting Early Hearing Impairment in Individuals With Normal Pure Tone Audiometry (PTA)

Acoustics, signals & systems for audiology. Psychoacoustics of hearing impairment

Terri-Lynn Gagnon M.Cl.Sc (AUD) Candidate University of Western Ontario: School of Communication Sciences and Disorders

Otoacoustic Emissions

Abstract. 1 Introduction

CASE REPORT. AUDITORY NEUROPATHY WITH BILATERAL BAT EARS A RARE CASE REPORT A. Sivakumar 1, V. Narendrakumar 2

Cochlear anatomy, function and pathology II. Professor Dave Furness Keele University

Ear Exam and Hearing Tests

Thresholds of Tone Burst Auditory Brainstem Responses for Infants and Young Children with Normal Hearing in Taiwan

Can components in distortion-product otoacoustic emissions be separated?

Hearing Evaluation: Diagnostic Approach

Update on Otoacoustic Emissions: Basic Science to Clnical Application. Morning Session

Audiology. Anita Gáborján MD, PhD.

Auditory System Feedback

Chapter 3. of energy that moves through air, water and other matter, in waves of pressure.

Clinical Study Unilateral Auditory Neuropathy Caused by Cochlear Nerve Deficiency

Contents. Foreword by James W. Hall III, PhD and Virginia Ramachandran, Aud, Series Editors Preface

ERO SCAN. OAE Test System. Screener. Diagnostic. with 4 frequency DPOAE testing Protocols

Paediatric Whitepaper

Mechanical Properties of the Cochlea. Reading: Yost Ch. 7

TEMPORARY HEARING THRESHOLD SHIFT MEASURED BY OTOACOUSTIC EMISSIONS IN SUBJECTS EXPOSED TO SHORT-TERM IMPULSE NOISE

Proceedings of Meetings on Acoustics

Fine structures in hearing thresholds and distortion product otoacoustic emissions

Simultaneous multiple stimulation of the auditory steadystate response (ASSR)

PERIPHERAL AND CENTRAL AUDITORY ASSESSMENT

The complexity of ANSD starts at the time of assessment

Early Hearing Detection & Intervention Programs, Pediatricians, Audiologists & School Nurses use AuDX Screeners

HST 721 Efferent Control Lecture October 2004

Protocol for Fast, Efficient Audiogram Prediction using Electrophysiology. Sponsored By

UPDATE ON ELECTROPHYSIOLOGIC MEASURES OF HEARING SENSITIVITY IN INFANTS

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

Detection of middle ear dysfunction using wideband acoustic tests in newborn hearing screening and diagnostic follow-up

Auditory Neuropathy Spectrum Disorder. Yvonne S. Sininger PhD Professor of Head & Neck Surgery University of California Los Angeles

Comparison of objective and subjective measures of cochlear compression in normalhearing and hearing-impaired listeners

SLHS 588A Electrophysiologic Assessment Techniques: FALL Class Meeting: Room 229-SLHS, MW 2:00 to 3:15 p.m; Lab: TBA;

1- Cochlear Impedance Telemetry

Estimating auditory filter bandwidth using distortion product otoacoustic emissions

Proceedings of Meetings on Acoustics

Fine Structure in Distortion Product Otoacoustic Emissions and Auditory Perception

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

Handheld OAE-Tympanometry Combination System

Basic Principles. The Current State of Auditory Steady-State Responses

Audiology 101 SOFT HIGH PITCH LOUD. How do we hear? Ear to the Brain. Main parts of the Ear

College of Medicine Dept. of Medical physics Physics of ear and hearing /CH

Study the Effect of the Quality Factor of the Transient Evoked Oto-acoustic Emissions (TEOAE)

Using Electrocochleography to Assess the Afferent Pathway in the Cochlea. Senior Thesis

NIH Public Access Author Manuscript Ear Hear. Author manuscript; available in PMC 2008 June 27.

GRASON-STADLER HEARING ASSESSMENT SYSTEMS

Audiology (Clinical Applications)

Updates to NHSP guidance for post-screening diagnostic testing Update 1: August 2015 Author: BSA Electrophysiology Special Interest Group (BSA EP SIG)

Introduction to Audiology: Global Edition

Understanding Otoacoustic Emissions Generation

HEARING IMPAIRMENT LEARNING OBJECTIVES: Divisions of the Ear. Inner Ear. The inner ear consists of: Cochlea Vestibular

A Case Study of Progressive Auditory Neuropathy

Newborn Screening and Middle Ear Problems

Transcription:

Otology & Neurotology 34:1058Y1063 Ó 2013, Otology & Neurotology, Inc. A Review of the Effectiveness of Otoacoustic Emissions for Evaluating Hearing Status After Newborn Screening Thomas Janssen ENT-Department, Technische Universität München, München, Germany Objectives: The purpose of this study was to give a brief review of the effectiveness of otoacoustic emissions for getting frequency-specific information about a hearing-loss problem in newborns after hearing screening. Especially, the advantages of distortion-product otoacoustic emissions (DPOAE) over transiently evoked otoacoustic emissions (TEOAEs) are described. Data Sources: Approximately 186 ears of 104 children aged between 76 days and 15 years and 436 ears of adults with normal hearing and sensory hearing loss. Methods: Extrapolated DPOAE I/O-functions at frequencies between 1.5 and 6 khz were obtained in the children for assessing the hearing loss and for differentiating between a transitory sound-conductive hearing loss and a persisting cochlear hearing loss. For getting information on the test time needed, measurements were performed in the adult patients. Results: DPOAE thresholds derived from extrapolated DPOAE I/O-functions (DPOAE audiograms) are closely related to behavior audiometric thresholds and can be used for determining characteristic quantities of the cochlear-impaired ear. A DPOAE audiogram can be obtained in a couple of minutes. DPOAE audiograms are able to reveal a transitory soundconductive hearing loss because of Eustachian tube dysfunction and/or amniotic fluid in the tympanic cavity or to confirm a persisting cochlear hearing loss because of outer hair cell impairment in babies with a reference result in newborn hearing screening. Conclusion: DPOAE audiograms provide a tool for a fast automated frequency-specific and quantitative evaluation of a mild or moderate hearing in follow-up diagnosis. Key Words: Audiologic evaluationvdistortion product otoacoustic emissionsvnewbornsvotoacoustic emissionsvtransiently evoked otoacoustic emissions. Otol Neurotol 34:1058Y1063, 2013. BACKGROUND The aim of pediatric audiologic evaluation of hearing capability in newborns who are referred from newborn hearing screening (follow-up) is to exclude a hearing deficit or to confirm and identify a hearing loss with the determination of its degree in cases where a hearing deficit cannot be excluded. Main purpose of follow-up diagnosis is to establish a working hypothesis for a successful hearing aid fitting. Subjective tests are only able to assess disorders of sound processing as a whole. Tympanometry, otoacoustic emissions (OAEs), and auditory brain stem responses (ABRs) in combination allow for a differentiation between sound-conductive, cochlear, and neural hearing loss. Like Address correspondence and reprint requests to Thomas Janssen, Prof. Dr.-Ing. Dr.med.habil., ENT-Department, Klinikum rechts der Isar, Technische Universität München, IsmaningerstraQe 22, 81675 München, Germany; E-mail: T.Janssen@LRZ.tum.de The author discloses no conflicts of interest. tympanometry, OAEs are a fast and easy-to-handle method. Registration of transiently evoked otoacoustic emissions (TEOAEs) is an indispensable part of followup diagnosis. In cases of conspicuous TEOAEs, measurement of distortion product otoacoustic emissions (DPOAEs) has to be imperatively performed, preferably at close-to-threshold stimulus levels. In the following, an overview is given on possibilities and limitations of OAEs to determine type (site) and degree of a hearing loss. Especially, the efficacy of extrapolated DPOAE I/Ofunctions for getting quantitative and frequency-specific information on the hearing loss is discussed. CAPABILITY OF TEOAES AND DPOAEs TEOAEs represent the sum of pulse responses of outer hair cells (OHCs) along the cochlea, whereas DPOAEs arise directly from the frequency-selective compressive nonlinearity of OHC amplifiers (1,2). In principle, both DPOAEs and TEOAEs allow acquisition of frequencyspecific information about a hearing loss problem. 1058

OAE FOR EVALUATING NEWBORN HEARING STATUS 1059 When stimulating the ear with a transient stimulus, almost all OHCs along the cochlear (when using a click) or a part of them (when using a tone-burst) are excited. Because of frequency dispersion in the cochlea, a specific component of the TEOAE response can be directly traced to a specific frequency component of the transient signal. As the basilar membrane at basal sites moves faster than at more apical sites, high-frequency TEOAE components stem from basal cochlear sites, whereas low-frequency TEOAE components come from more apical ones. However, because of the fact that the stimulus and the high-frequency TEOAE components superimpose (and therefore have to be cancelled during TEOAE recording), TEOAEs fail to measure cochlear function above 4 khz (3). In contrast, DPOAEs are able to asses outer hair cell function at different sites of the cochlea separately depending on the primary-tone frequency. Stimulus (primary-tones at f 2andf 1) and response (2f 1Yf 2) do not superimpose Fig. 1. There are some limitations when performing OAE measurements. Electric microphone noise, physiologic noise (breathing, blood flow), and external acoustic noise do not allow reliable measurements below 1 khz. Because of the limited frequency range of the sound probe s electroacoustic transducers, high-frequency OAE measurements are difficult without using specialized devices. Moreover, at high frequencies (96 khz), standing waves in the outer ear canal make a defined primary-tone setting for eliciting DPOAEs difficult to obtain. For more detailed information on OAE generation, stimulus setting, OAE recording, and clinical applications, see (4). TONOTOPIC ASSESSMENT OF HEARING LOSS OAEs are a fast measure to confirm normal middle ear and cochlear function. This is the case if OAEs are present over a wide frequency range. In case of missing OAEs, middle ear or cochlear (OHC) pathology is likely. OAEs then should be followed by tympanometry. If the tympanogram is abnormal, a sound-conductive hearing loss is likely. If the tympanogram is normal and OAEs are abnormal or absent, then a cochlear disorder is likely. If both tympanogram and OAEs are normal, ABRs are needed to reveal whether there is a cochlear (inner hair cell) or neural pathology. For example, in auditory neuropathy, where synchronization of neural activity is malfunctioning (either because of inner hair cell synaptic or neural dysfunction), normal OAEs and abnormal ABRs occur (5,6). FIG. 1. Schematic drawing to show how TEOAEs and DPOAEs are evoked within the cochlea and subsequently measured in the outer ear canal. The sound probe consists of a microphone for measuring the acoustic response signal and either one loudspeaker for applying a click stimulus (TEOAE) or of 2 loudspeakers for applying 2 independently generated primary tones with frequencies f 1 and f 2 and levels L 1 and L 2. OAEs are a by-product of nonlinear sound amplification within the cochlea because of outer hair cell (OHC) motility. TEOAEs represent OHC pulse responses along the basilar membrane. Basal high-frequency responses appear at the beginning, and apical lowfrequency responses appear at the end of the TEOAE time function. Stimulus and high-frequency TEOAE responses superimpose and are therefore removed from the microphone signal. Noise is lowest at mid frequencies. Therefore, TEOAEs fail to obtain information on cochlear function at high and low frequencies. DPOAEs are generated within the region of overlap of the traveling waves of the 2 primary tones close to the f 2 place. Thus, DPOAE provide information on cochlear function at a distinct place.

1060 T. JANSSEN QUANTITATIVE EVALUATION OF HEARING LOSS Especially for hearing aid adjustment in infants, a quantitative evaluation of the hearing loss is necessary. When elicited by high stimulus levels (which is common in clinical practice), TEOAEs are absent at a cochlear hearing loss exceeding 20 db HL, whereas DPOAEs are absent only at a cochlear hearing loss exceeding 40 to 50 db HL. Thus, when using TEOAEs and DPOAEs elicited at high stimulus levels only, a rough estimate of the hearing loss is possible. For example, when TEOAEs are absent and DPOAEs are present, then the hearing loss is suggested to be not more than 30 db HL. The relation between DPOAE level and auditory threshold is strongly debated. Earlier, it was common to define confidence limits to determine the degree of certainty with which any measured response could be assigned to either normal or impaired hearing (7,8) or to define a DPOAE detection threshold as the stimulus level at which the response equaled the noise present in the instrument (9). However, because noise superimposes, the response threshold evaluated in this way does not match the behavioral threshold. A more reliable measure is the intersection point between the extrapolated DPOAE I/O-function and the primary-tone level axis (10,11). DPOAE data can be easily fitted by linear regression analysis in a semilogarithmic plot, where the intersection point of the regression line with the L2 primary-tone level axis at pdp = 0 Pa can thus serve as an estimate of the DPOAE threshold (Fig. 2). The estimated DPOAE threshold is independent of noise and seems to be more closely related to behavioral threshold than the DPOAE detection threshold (10,11). It should be emphasized that a linear dependency between the DPOAE sound pressure and the primary-tone sound pressure level is only present when using a special stimulus settingvthe scissor paradigm (12)Vwhich accounts for the different compression of the primarytone traveling waves at the f 2 place (10,12Y14). Because of the steep slope of the traveling wave toward the cochlear apex, maximum interaction site is close to the f 2 place. Thus, OHCs at the f 2 place contribute most to DPOAE generation. The number of OHCs contributing to DPOAE generation depends on the size of the overlapping region, which is determined by the primarytone level setting L1 L2 and the frequency ratio f 2/f 1of FIG. 2. Schematic drawing of how to determine DPOAE thresholds and to estimate hearing loss at different test frequencies when eliciting DPOAEs using scissor stimulus setting (L1 = 65 L2 = 65, L1 = 63 L2 = 60, L1 = 61 L2 = 55 L1 = 59 L2 = 50, L1 = 57 L2 = 45, L1 = 55 L2 = 40, L1 = 53 L2 = 35, L1 = 51 L2 = 30). DPOAEs are plotted in double-logarithmic (L across L2) and semi-logarithmic (p across L2) scales. Intersection of the linear regression line with L2 axis serves as an estimate of DPOAE threshold. At test frequencies where DPOAEs are only present at 2 L2 levels or 1 L2 level, no extrapolation is performed. In this case, the estimated threshold is calculated by the lowest L2 (L2min) at which a valid DPOAE could be achieved minus 15 db. After converting SPL in HL, a DPOAE audiogram is constructed. Circle means threshold estimation by means of extrapolated DPOAE I/O functions; square means simplified estimation L2minV15dB; arrow symbol means no DPOAE are measurable, and thus, the hearing loss is estimated to be higher than 50 db HL.

OAE FOR EVALUATING NEWBORN HEARING STATUS 1061 the primary tones. To preserve optimum overlap of the primary-tone traveling waves at a constant frequency ratio f 2/f1 = 1.2, the primary-tone level difference has to be increased with decreasing stimulus level, resulting in a L1 L2 setting described by L1 = 0.4L2 + 39 dbspl (scissor paradigm). When converting DPOAE sound pressure level (SPL) to hearing loss level (HL), the estimated DPOAE thresholds can be plotted in an audiogram form (DPOAE audiogram). DPOAE audiograms can be applied in babies with a refer result in newborn hearing screening to reveal a transitory sound-conductive hearing loss because of Eustachian tube dysfunction and/or amniotic fluid in the tympanic cavity or to confirm a persisting cochlear hearing loss in follow-up diagnosis. One case example shall illustrate how DPOAE audiograms can reveal temporary sound-conductive disorders in the early postnatal period (Fig. 3). In a newborn with a refer ATEOAE screening response, the DPOAE audiogram indicated a hearing loss of more than 50 db at 1.5, 2, 3, and 6 khz (arrows in Fig. 3) and a 40-dB hearing loss at 4 khz. The second measurement 12 days later revealed normal hearing function. In this baby, both a low- and a high-frequency sound-conductive hearing loss might have been present where middle ear stiffness is increased because of Eustachian tube dysfunction (low frequencies are affected), and middle ear mass is increased because of amniotic fluid (high frequencies are affected). FIG. 3. DPOAE audiograms in 2 newborns (A and B) with temporary sound-conductive hearing loss. Newborn a with a pass ATEOAE screening response exhibits a low-frequency hearing loss in the first measurement (3 d after birth). In the second measurement (86 d after birth), the DPOAE audiogram indicates normal hearing. In newborn b with a refer ATEOAE screening response, no DPOAE could be measured (except at 4 khz) in the first measurement (1 d after birth). DPOAE audiogram obtained in the second measurement (13 d after birth) indicates normal hearing. Three case examples shall demonstrate the efficacy of DPOAE audiograms for evaluating a persisting cochlear hearing loss. Pure-tone audiogram and DPOAE audiogram obtained in a 5-year-old boy exhibit a close correspondence (Fig. 4A). This is to show that older children are able to reliably report on their hearing loss. In contrast, in the 2 younger children, there is a high discrepancy between the behavioral free-field audiogram and the DPOAE audiogram. The free-field audiogram of a 5-month-old girl FIG. 4. Pure-tone audiograms (open circles) and DPOAE audiograms (black symbols) 6 years old boy, left ear (A); 5 month old girl, left ear (B); 3 months old girl, right (C) and left ear (D). Pure-tone audiogram and DPOAE audiogram are closely related in the 6-year-old boy. The free-field audiogram (dotted lines) of the 5-month-old girl indicates a hearing loss of 50 db HL in the entire frequency range. However, the DPOAE audiogram reveals a hearing loss only in the mid and low frequency range. The free-field audiogram of the 3-month-old girl indicates a hearing loss of 40 db HL. In the right ear, DPOAEs are not present, indicating that the hearing loss must be higher than 50 db (red arrows in Fig. 4C). In the left ear, DPOAE audiogram indicates normal hearing.

1062 T. JANSSEN FIG. 5. Scatter plot of the difference between behaviora1and estimated threshold from DPOAE I/O-functions across age obtained in 186 ears of 104 children aged between 76 days and 15 years. Squares represent free-field, and circles represent head-phone thresholds. Difference between behavioral and estimated thresholds decreases with increasing age. FIG. 6. Scatter plot of measuring time for getting a DPOAE audiogram at frequencies f2 = 1.5, 2, 3, 4, and 6 khz across average audiometric hearing thresholds. Data are from 436 ears of patients with cochlear hearing loss. (Fig. 4B) indicates a hearing loss of 50 db HL in the entire frequency range. However, the DPOAE audiogram reveals a hearing loss only in the mid and low frequency region. Figure 4C shows the free-field audiogram and the DPOAE audiograms of the left and the right ear of a 3-month-old girl. The free-field audiogram indicates a hearing loss of 40 db HL. In the right ear, DPOAEs are absent, indicating that the hearing loss must be higher than 50 db (arrows in Fig. 4C). In the left ear, DPOAE audiogram reveals normal hearing. Figure 5 shows the difference between behavioral pure-tone thresholds and estimated DPOAE thresholds across age obtained in 186 ears of 104 children aged between 76 days and 15 years. Red circles represent conditioned free-field pure-tone thresholds, and blue circles represent head-phone pure-tone thresholds. The difference between behavioral and estimated threshold is high in the first year of life ranging between 32 and 68 db. Within the period of the second and third year of life, the difference decreases rapidly. In children older than 3 years, the difference remains nearly constant being about 10 db on average. The difference of 10 db indicates that the physiologic measure is more sensitive than the behavioral threshold. This may be due to the fact that the stimulus level at which the child is able to respond has to be a certain degree higher than the real hearing threshold level. DPOAE audiograms can be obtained by means of an automated measuring procedure with simple handling and short measuring time. The time for getting a DPOAE audiogram, which predicts hearing threshold at 1.5, 2, 3, 4, and 6 khz is shown in Figure 6. Data are from 436 ears of adults with normal hearing and sensory hearing loss. Measuring time is plotted over the average behavioral pure-tone threshold obtained from the clinical audiogram of each individual. At normal hearing (G10 db HL), a DPOAE audiogram can be obtained in 2 or 3 minutes. At slight hearing losses (10Y20 db), measuring time is longest (up to 7.5 min) because DPOAE amplitude is low but DPOAEs are present at almost all primary tone levels. The higher the hearing loss, the lower is the number of primary tone levels at which a valid DPOAE can be measured. Consequently, the shorter is the measuring time. Thus, measuring time decreases rapidly at a hearing loss higher than 20 db HL, about 3 minutes at an average pure-tone hearing loss of 40 db HL, and about 2 minutes at an average pure-tone hearing loss of 60 db HL. CONCLUSION A reliable diagnosis of a hearing deficit in newborns referred from newborn hearing-screening is only ensured if as many as possible objective audiometric tests are performed: tympanometry for evaluating middle ear status, otoacoustic emissions for assessing the function of cochlear amplification, and auditory evoked potentials for assessing synaptic and neural functionality. TEOAEs more qualitatively assess cochlear function and are therefore more suited for topologic diagnostics. DPOAEsVespecially DPOAE audiogramsvprovide more quantitative information about the hearing loss. DPOAE audiograms are able to assess cochlear hearing loss more precisely than behavioral tests in infants where the conditioned free-field audiogram does not reflect the real threshold. Moreover, unilateral hearing loss can be detected. DPOAE audiograms can reveal a transitory sound-conductive hearing loss in the early postnatal period. DPOAE audiograms are an alternative method to tone-burst or chirp evoked ABRs or auditory steady-state responses (ASSRs) in case of a mild or moderate hearing loss. Test time for establishing a DPOAE audiogram takes only a couple of minutes. Thus, DPOAE audiograms have an essential advantage over ABRs or ASSRs. DPOAE

OAE FOR EVALUATING NEWBORN HEARING STATUS 1063 audiograms can help to establish a working hypothesis for a more successful hearing aid fitting. Because DPOAEs only reflect outer hair cell functionality, they are not present at frequencies where the hearing loss is higher than 50 db HL. However, the incidence of a hearing loss higher than 50 db in children with a hearing problem is low. Thus, in most of the children with hearing problems, DPOAEs are measurable at least at high stimulus levels. In cases where DPOAEs are not measurable, ASSRs have to be measured for getting frequency-specific information on the hearing loss in the entire range of hearing. REFERENCES 1. Brownell WE, Bader CR, Bertrand D, et al. Evoked mechanical responses of isolated cochlear outer hair cells. Science 1985; 227:194Y6. 2. Kemp DT, Bray P, Alexander L, et al. Acoustic emission cochleographyv practical aspects. Scand Audiol Suppl 1986;25:71Y95. 3. Bray P. Click Evoked Otoacoustic Emissions and the Development of a Clinical Otoacoustic Hearing Test Instrument. London, UK: Dissertation at the University College and Middlesex School of Medicine, 1989. 4. Janssen T, Müller J. Otoacoustic emissions as a diagnostic tool in a clinical context. In: Manley GA, Fay RR, Popper AN, eds. Active Processes and Otoacoustic Emissions in Hearing. New York, NY: Springer, 2008:421Y51. 5. Doyle KJ, Fujikawa S, Rogers P, et al. Comparison of newborn hearing screening by transient otoacoustic emissions and auditory brainstem response using ALGO-2. Int J Pediatr Otorhinolaryngol 1998;43:207Y11. 6. Starr A, Picton TW, Sininger Y, et al. Auditory neuropathy. Brain 1996. 119(Pt 3):741Y53. 7. Gorga MP, Stover L, Neely ST, et al. The use of cumulative distributions to determine critical values and levels of confidence for clinical distortion product otoacoustic emission measurements. J Acoust Soc Am 1996;100(2 Pt 1):968Y77. 8. Gorga MP, Nelson K, Davis T, et al. Distortion product otoacoustic emission test performance when both 2f1-f 2 and 2f2-f1 are used to predict auditory status. J Acoust Soc Am 2000;107:2128Y35. 9. Dorn PA, Konrad-Martin D, Neely ST, et al. Distortion product otoacoustic emission input/output functions in normal-hearing and hearing-impaired human ears. J Acoust Soc Am 2001;110:3119Y31. 10. Boege P, Janssen T. Pure-tone threshold estimation from extrapolated distortion product otoacoustic emission I/O-functions in normal and cochlear hearing loss ears. J Acoust Soc Am 2002; 111:1810Y8. 11. Gorga MP, Neely ST, Dorn PA, et al. Further efforts to predict puretone thresholds from distortion product otoacoustic emission input/ output functions. J Acoust Soc Am 2003;113:3275Y84. 12. Kummer P, Janssen T, Hulin P, et al. Optimal L(1)-L(2) primary tone level separation remains independent of test frequency in humans. Hear Res 2000;146:47Y56. 13. Whitehead ML, Stagner BB, Lonsbury-Martin BL, et al. Dependence of distortion-product otoacoustic emissions on primary levels in normal and impaired ears. II. Asymmetry in L1,L2 space. JAcoust Soc Am 1995; 97:2359Y77. 14. Whitehead ML, McCoy MJ, Lonsbury-Martin BL, et al. Dependence of distortion-product otoacoustic emissions on primary levels in normal and impaired ears. I. Effects of decreasing L2 below L1. J Acoust Soc Am 1995;97:2346Y58.