Chandra Ramamoorthy MBBS; FRCA (UK) Professor of Anesthesiology, Stanford University. Director of Pediatric Cardiac Anesthesiology

Similar documents
Near Infrared Spectroscopy in Medical Diagnostics

Oxygen Saturation Monitors & Pulse Oximetry. D. J. McMahon rev cewood

Oximeters. Hsiao-Lung Chan, Ph.D. Dept Electrical Engineering Chang Gung University, Taiwan

NIRS of the brain new diagnostic tool

Near-Infrared Monitoring of Brain and Tissue Oxygenation: Is the Monitor on the Right Person?

When Cyanosis is the Norm. Steven M. Schwartz, MD, FRCPC Cardiac Critical Care Medicine The Hospital for Sick Children Toronto

Absolute Cerebral Oximeters for Cardiovascular Surgical Cases

The first oximetry system to put regional oximetry, pulse oximetry and ease of use at your fingertips.

Oximeters. Hsiao-Lung Chan, Ph.D. Dept Electrical Engineering Chang Gung University, Taiwan

Cerebral Oximetry in Preterm Infants: Methods, Measurements and Evaluating Clinical Benefit

Evaluation of Pediatric Near-Infrared Cerebral Oximeter for Cardiac Disease

SenSmart Model X-100. The first oximetry system to put regional oximetry, pulse oximetry and ease of use at your fingertips.

CEREBRAL OXIMETRY IN INFANTS WITH HIE DAPHNA YASOVA BARBEAU, MD FN3 MEETING 2018

Disclosures. Set up audience participation. Test question. Outline. Neuromonitoring What and When? IP for monitoring technology licensed to Medtronic

INVOS System Inservice Guide for Pediatric Use. INVOS System Inservice Guide for Pediatric Use

Dr. D.McG.Clarkson Determining the Accuracy of SpO2 Values

All This Monitoring What's Necessary, What's Not

Functional cerebral monitoring in patients with critically illness

Near Infrared Spectroscopy in Neonatal Intensive Care

On behalf of the education Committee of the SNACC

SenSmart. Universal Oximeter System W: E: T: F:

Multimodal Brain Monitoring with NIRS and aeeg and their Clinical Significance

Biomedical Instrumentation D. The Photoplethysmogram

How Does Pulse Oximetry Work? SpO2 Sensors Absorption at the Sensor Site Oxyhemoglobin Dissociation Curve

Evaluation of the EQUANOX, FORE-SIGHT and INVOS Systems at St. Francis Hospital in Columbus, GA 1

Cerebral Oximetry is Frequently a First Alert Indicator of Adverse Outcomes

Oximetry. Jan Bakker. Grants Hutchinson Pulsion.

Small-Cap Research. CAS Medical Systems Inc. (CASM-NASDAQ) CASM: FORE-SIGHT Gobbling Up Market Share. Initiating Coverage OUTLOOK SUMMARY DATA

ICP (Intracranial Pressure) Monitoring Brain Tissue Oxygen Monitoring Jugular Venous Bulb Oximetry

Current bedside monitors of brain blood flow and oxygen delivery

Check a Pulse! When to Question SpO 2, NIBP & EtCO 2 Readings

CEREBRAL oximetry using near-infrared spectroscopy

CEREBRAL OXIMETRY IS FREQUENTLY A FIRST ALERT INDICATOR OF ADVERSE OUTCOMES

Pulse oximetry revisited. Dr Liesel Bösenberg Specialist Physician and Fellow in Critical Care Kalafong Hospital University of Pretoria

Journal of Faculty of Engineering & Technology DESIGN AND IMPLEMENTATION OF A WEARABLE HEALTH DEVICE

Materials and Methods

Transfusion Limbo How Low Will You Go? Safely. Nina A. Guzzetta, M.D. Children s Healthcare of Atlanta Emory University School of Medicine

Regional and central venous oxygen saturation monitoring following pediatric cardiac surgery: Concordance and association with clinical variables*

Muscle OxyGen monitor. The Science Behind Moxy

NIRS utilization during first hours and days of life

About OMICS International

pulse oximetry sensors 2007

Appendix E Choose the sign or symptom that best indicates severe respiratory distress.

Posted: 11/27/2011 on Medscape; Published Br J Anaesth. 2011;107(2): Oxford University Press

CEA and cerebral protection Volodymyr labinskyy, MD

State of the Art Multimodal Monitoring

Measurements of oxygen saturation of brain, liver and heart areas in the supine and sitting position using near infrared spectrophotometry

Development of a New Rehabilitation System Based on a Brain-Computer Interface Using Near-Infrared Spectroscopy

The contribution of the external carotid artery to cerebral perfusion in carotid disease

Monitoring Tumor Therapy

Probing Brain Oxygenation with Near Infrared Spectroscopy

Consumer Near Infrared Spectroscopy as a Training and Recovery Tool. Jon Tarkington

Research Journal of Pharmaceutical, Biological and Chemical Sciences

NEONATAL MONITORING IN-SERVICE GUIDE

Lisa T. Hannegan, MS, CNS, ACNP. Department of Neurological Surgery University of California, San Francisco

Nonin Medical OEM Pulse Oximetry Solutions. Superior Performance for Challenging Patient Conditions

ORIGINAL RESEARCH. Effect of road traffic accident contaminants on pulse oximetry among normoxaemic volunteers

Cerebral Perfusion Directly Revealed INVOS Cerebral/Somatic Oximeter Improving Patient Outcomes and Safety in Adult Surgery

Empowering the RT with New Noninvasive Monitoring Capabilities

Testing Masimo rainbow Technology with vpad-a1 1. Background

IMPROVE PATIENT OUTCOMES AND SAFETY IN ADULT CARDIAC SURGERY.

CORRELATION BETWEEN MEASUREMENT OF ARTERIAL SA TURA TION BY PULSE OXIMETRY AND BY HEMOXYMETER IN CHILDREN WITH CONGENITAL HEART DISEASE

11/27/2012. Objectives. What is Critical Congenital Heart Disease?

How to maintain optimal perfusion during Cardiopulmonary By-pass. Herdono Poernomo, MD

Yuko Kondo, Kaoru Sakatani, Noriya Hirose, Takeshi Maeda, Jitsu Kato, Setsuro Ogawa, and Yoichi Katayama

Rango de saturacion de oxigeno: Cual es la evidencia?

NEONATAL CLINICAL PRACTICE GUIDELINE

Supplementary Online Content

The Effect of Autologus Blood Priming on Cerebral Oximetry in Congenital Cardiac Surgery Patients

Peripheral tissue oximetry: comparing three commercial nearinfrared spectroscopy oximeters on the forearm

Advanced Monitoring of Cardiovascular and Respiratory Systems in Infants Kuwait 2018 Dr. Yasser Elsayed, MD, PhD Director of the Targeted Neonatal

Are Patients Hypoperfused in the ED? Rapid Perfusion Assessment in the Emergency Department

What s new in neonatal resuscitation?

The Clinical Utility of Cerebral Oximetry Monitoring

Design and Development of Non-Invasive Prototype to Measure Pulse Rate, Blood Glucose and Oxygen Saturation Level in Arterial Blood

Anesthesia and the beach chair position

Cerebral and Lower Limb Near-Infrared Spectroscopy in Adults on Extracorporeal Membrane Oxygenation

6/17/16. Near-Infrared Spectroscopy (NIRS): Principles, Evidence and Clinical Applications. What is Near Infrared Spectroscopy (NIRS)?

Trust Nonin Oximeters, Even For Your Sickest Patients

Newborn Hypoxic Ischemic Brain Injury. Hisham Dahmoush, MBBCh FRCR Lucile Packard Children s Hospital at Stanford

Correlation of Ratio of Ratio of Near Infrared Vs Infrared Photoplethysmograph Spectroscopy for the Non-Invasive Measurement of Haemoglobin

Why Old Blood is Bad. tales from the electronic perfusion record. Molly Marko, BS, BSE, CCP Geisinger Health System Danville, Pennsylvania

Light is wearable Health Monitoring and Fitness Tracking Light is OSRAM

Ancillary Testing in Death

Supplementary Online Content

Permanent City Research Online URL:

Citation for published version (APA): Mebius, M. J. (2018). Congenital heart disease : the timing of brain injury. [S.n.].

Our Vision That no patient is harmed by undetected tissue hypoxia.

SUBJECT INFORMATION AND CONSENT FORM

Sepsis Wave II Webinar Series. Sepsis Reassessment

Near infrared spectroscopy after high risk congenital heart surgery in the paediatric intensive care unit

NO CONFLICTS NO CONFLICTS

Hybrid EEG-HEG based Neurofeedback Device

Michel MRF Struys, MD, PhD, FRCA

Near-infrared spectroscopy for monitoring cerebral ischemia during selective cerebral perfusion

The Effect of Optimising Cerebral Tissue Oxygen Saturation on Markers of Neurological Injury during Coronary Artery Bypass Graft Surgery

Neurodevelopmental Outcomes After Regional Cerebral Perfusion With Neuromonitoring for Neonatal Aortic Arch Reconstruction

MiECC AND THE BRAIN Helena Argiriadou

ECMO Primer A View to the Future

Appendix D An unresponsive patient with shallow, gasping breaths at a rate of six per minute requires:

Transcription:

Should NIRS be Standard Care for Pediatric CPB Chandra Ramamoorthy MBBS; FRCA (UK) Professor of Anesthesiology, Stanford University Director of Pediatric Cardiac Anesthesiology Stanford Children s Hospital Stanford CA 94305 March 2015, Phoenix

Disclosures Past Speaker: Somanetics Corp. Clinical Researcher: Nonin Inc Masimo Inc

Audience Question-1 Use of cerebral oximetry during CPB is routine Yes No

Audience Participation Question -2 The level of evidence supporting routine use of pulse oximetry is 1 A True False

Audience Question-3 In cyanotic patients most pulse oximeters are inaccurate, hence I : A) Add oxygen when I am uncomfortable with the value B) I use a special sensor for cyanotic patients that s more accurate C) Accept the inaccurate value and intervene when the Heart rate drops.

Cerebral Oximetry Near Infra red light source 700-1000 nm Detectors-2 Optical length Absorption of light by HbO2 /Hb Validated: Jugular Bulb Oximetry Venous weighted saturation : 70:30

Cerebral Oximeters: FDA Approved Commercial Devices Invos, Somanetics Foresight,Casme d Equanox, Nonin Inc Masimo Inc Light Source Wavelength LED 2 Laser 4 LED 4 LED 4

Critical Values Normal : 60-70% (2/3rd SaO2) Kurth, 2002, piglets: Lactate, EEG, ATP reduction: 33-44% ScO2 Duration of Ischemia and Extent affect outcomes (Kurth, 2007)

Variations in cerebral oximeters Light Source : LED vs laser Number of wave lengths : 2-4 Distance between emitter and detector Proprietary algorithm Devices display proportional bias : under vs over detection All of the above leads to variations in values making comparisons difficult

Cerebral Oximetry Use Case reports Retrospective case-control studies Expert Opinion Consensus statement Randomized control trial

Clinical Outcome Data in Children Austin et al 1997: Improved neurological outcomes in children after OHS retrospective, case-control study Evidence Level 2b: benefits outweigh risks

Clinical Outcome Data in Children Dent et al 2006, J Thorac Cardiovasc Surg Single Ventricle n=22 Pre and Post: Neuro exam, EEG, Brain MRI Prolonged post op rso2% <45% for >er than 180 mins associated with new MRI brain lesions (n=14)

Clinical Outcome Data Andropoulos: J Thorac CV Surg: 2010, Single and 2 Ventricle pts EEG, MRI and NIRs, Standardized anesthetic 2V patients with low rso2 post-op = 0 50% SV with prolonged low rso2 Prolonged rso2 not associated with MRI changes in all but only 1/3rd

Cerebral Oximetry-Use in Children undergoing CPB? Adverse effects despite its use STS Task Force : Not Unanimous Evidence level 3: Not beneficial Evidence level 2B: Benefits outweigh risk No level 1A evidence Cost vs Benefit

CCAS Data Data between 2010-2014; CPB & No CPB Roughly 25,000 cases reported Roughly 17,000 had neuro-monitoring In 80% of cases NIRS mornitoring was used 6% BIS; <1 TCD Incomplete data reported David Vener MD, Texas Children s Hospital

Improve Data collection Data not being collected on cannulae re-position Changes to CPB Hb Temperature PaCO 2 Anesthetic technique Vasopressors GOLD Standard: RCT

Has the time come to use near-infrared spectroscopy as a routine clinical tool in preterm infants undergoing intensive care? N=4000 Cerebral oximetry must reduce the risk of a clinically relevant endpoint, such as death or neurodevelopmental handicap Ultimate way of demonstrating the added value is by a randomized trial October 2011

Pulse Oximetry Introduced 1982-1983 Routine continuous pulse oximetry monitoring did not reduce transfer to the ICU and did not decrease mortality, and it is unclear whether any real benefit was derived from the application of this technology for patients-----------

Pulse Oximetry Variations between oximeters- Nellcor, Masimostandard and blue sensor Most are calibrated using volunteers and hypoxic mixtures Below 85% accuracy decreases When compared with co-oximeter-gold standard, significant variation at lower saturation

Oximetry: Monitoring the Brain as an Index organ. John M. Murkin, M.D., F.R.C.P.C Editorial Are we asking the right questions? Should we be using cerebral oximeter as overall index of tissue oxygen supply?

Conclusion Cerebral oximetry is an innovative technique to assess oxygenation of the brain Inter-individual variations in values and between individual variations are poorly understood Risk Benefit ratio is favourable despite cost Continue to work on understanding and improving the technology

Audience Question Do you think Cerebral oximetry should be added as a standard monitor during CPB Yes No Thank You