Echocardiographic Guidance During Placement of the Buttoned Double-Disk Device for Atrial Septa1 Defect Closure

Similar documents
Atrial Septal Defects

2D/3D in Evaluation of Atrial Septum

INTEGRATING ECHOCARDIOGRAPHY WITH CATHETER INTERVENTIONS FOR CONGENITAL HEART DISEASE. Krishna Kumar SevenHills Hospital, Mumbai, India

Adult Echocardiography Examination Content Outline

Atrial Septal Defect Closure. Stephen Brecker Director, Cardiac Catheterisation Labs

Pediatric Echocardiography Examination Content Outline

Transcatheter Atrial Septa1 Defect Closure: Preliminary Experience with the Rashkind Occluder Device

Revealing new insights. irotate electronic rotation and xplane adjustable biplane imaging. Ultrasound cardiology. irotate and xplane

Diversion of the inferior vena cava following repair of atrial septal defect causing hypoxemia

Echocardiography in Adult Congenital Heart Disease

Echocardiography Conference

Giovanni Di Salvo MD, PhD, FESC Second University of Naples Monaldi Hospital

ΔΙΑΧΕΙΡΙΣΗ ΑΣΘΕΝΩΝ ΜΕ ΜΕΣΟΚΟΛΠΙΚΗ ΕΠΙΚΟΙΝΩΝΙΑ ΖΑΧΑΡΑΚΗ ΑΓΓΕΛΙΚΗ ΚΑΡΔΙΟΛΟΓΟΣ ΗΡΑΚΛΕΙΟ - ΚΡΗΤΗ

Index. cardiology.theclinics.com. Note: Page numbers of article titles are in boldface type.

Uptofate Study Summary

JOINT MEETING 2 Tricuspid club Chairpersons: G. Athanassopoulos, A. Avgeropoulou, M. Khoury, G. Stavridis

ATRIAL SEPTAL CLOSURE AND LEFT ATRIAL APPENDAGE OCCLUSION: INDICATIONS AND GUIDANCE ECHOCARDIOGRAPHY IN INTERVENTIONAL CARDIOLOGY

Left Ventricular Outflow Tract Obstruction Defined by Active Three-Dimensional Echocardiography Using Rotational Transthoracic Acquisition

Intracardiac echocardiography: an ideal guiding tool for device closure of interatrial communications

Data Collected: June 17, Reported: June 30, Survey Dates 05/24/ /07/2010

Implantation of Cardioverter Defibrillator After Percutaneous Closure of Atrial Septal Defect

5.8 Congenital Heart Disease

Type Size AP/PS RP/RS Qp/Qs. Ia Resistive <0.3 < Ib Resistive <0.3 < IIa Resistive <0.5 >2

Case 47 Clinical Presentation

PART II ECHOCARDIOGRAPHY LABORATORY OPERATIONS ADULT TRANSTHORACIC ECHOCARDIOGRAPHY TESTING

The earliest application of intracardiac imaging

Percutaneous VSD closure

Breakout Session: Transesophageal Echocardiography

PROSTHETIC VALVE BOARD REVIEW

List of Videos. Video 1.1

Assessment of Atrial Septal Defect Role of Real-Time 3D Color Doppler Echocardiography for Interventional Catheterization

Congenital heart disease. By Dr Saima Ali Professor of pediatrics

Welcome Number 6. The background of the Cardiac Sonographer Network News masthead is a diagnostic image:

Certificate in Clinician Performed Ultrasound (CCPU) Syllabus. Rapid Cardiac Echo (RCE)

Case # 1. Page: 8. DUKE: Adams

ECHOCARDIOGRAPHIC APPROACH TO CONGENITAL HEART DISEASE: THE UNOPERATED ADULT

Department of Pediatrics and Child Health, Kurume University School of Medicine, Kurume, 830 Japan. Received for publication October 26, 1992

Anatomy & Physiology

Adult Congenital Heart Disease: What All Echocardiographers Should Know Sharon L. Roble, MD, FACC Echo Hawaii 2016

HISTORY. Question: What category of heart disease is suggested by this history? CHIEF COMPLAINT: Heart murmur present since early infancy.

Journal of American Science 2014;10(9) Congenital Heart Disease in Pediatric with Down's Syndrome

Transcatheter closure of atrial septal defects with transthoracic echocardiography

Device Closure of ASD in Children Using the Amplatzer Devices: Indications and catheter preparations, technique, and outcome [15]

Hybrid Muscular VSD Closure in Small Weight Children

Uncommon Doppler Echocardiographic Findings of Severe Pulmonic Insufficiency

COMPREHENSIVE EVALUATION OF FETAL HEART R. GOWDAMARAJAN MD

Transcatheter closure of the patent ductus arteriosus using the new Amplatzer duct occluder: Initial clinical applications in children

Journal of the American College of Cardiology Vol. 33, No. 5, by the American College of Cardiology ISSN /99/$20.

Transcatheter closure of patent foramen ovale using the internal jugular venous approach

Echocardiography in the Adult with Congenital Heart Disease

Echocardiography in Congenital Heart Disease

Transcatheter closure of interatrial

Normal TTE/TEE Examinations

Assessing Cardiac Anatomy With Digital Subtraction Angiography

Little is known about the degree and time course of

A case report: Percutaneous transcatheter treatment of Lutembacher syndrome

Appendix II: ECHOCARDIOGRAPHY ANALYSIS

Transposition of the Great Arteries Preoperative Diagnostic Considerations. John Simpson Evelina Children s Hospital London, UK

Left atrial function. Aliakbar Arvandi MD

Pulmonary Venous Flow in Large, Uncomplicated Atrial Septal Defect

Anaesthesia for percutaneous closure of atrial septal defects Patrick A Calvert BCh MA MRCP Andrew A Klein MBBS FRCA

Hemodynamic Assessment. Assessment of Systolic Function Doppler Hemodynamics

Diagnostic approach to heart disease

Among the congenital defects of the heart diagnosed

British Society of Echocardiography

Percutaneous occluder device closure through femoral vein guidance by transthoracic echocardiography in adult atrial septal defect patients

Mitral Valve Disease, When to Intervene

Cardiac MRI in ACHD What We. ACHD Patients

A Magnetic Resonance Imaging Method for

Multimodality Imaging of Septal Defects

Γεώργιος Δ. Κατσιμαγκλής. Αν. Διευθυντής Καρδιολογικής ΚλινικήςΝΝΑ Διευθυντής Αιμοδυναμικού Εργαστηρίου ΝΝΑ

Transesophageal Echocardiography in Children: An Interactive Session on Common Congenital Cardiac Defects

Index. interventional.theclinics.com. Note: Page numbers of article titles are in boldface type.

Transesophageal Doppler Color Flow Mapping Assessment of Atrial Septal Defect

Common Defects With Expected Adult Survival:

Echocardiography as a diagnostic and management tool in medical emergencies

THE HEART. Unit 3: Transportation and Respiration

Cardiac ultrasound protocols

Heart and Lungs. LUNG Coronal section demonstrates relationship of pulmonary parenchyma to heart and chest wall.

Cigna - Prior Authorization Procedure List Cardiology

Very late recurrence of sinus of Valsalva aneurysm rupture after patch repair

PRACTICAL GUIDE TO FETAL ECHOCARDIOGRAPHY IC Huggon and LD Allan

Concomitant procedures using minimally access

Interventions in Adult Congenital Heart Disease: Role of CV Imaging. Associate Professor. ACHD mortality. Pillutla. Am Heart J 2009;158:874-9

MITRAL STENOSIS. Joanne Cusack

Foetal Cardiology: How to predict perinatal problems. Prof. I.Witters Prof.M.Gewillig UZ Leuven

Absent Pulmonary Valve Syndrome

The role of intraoperative TOE in congenital cardiac surgery

The Normal Echocardiogram

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

DIAGNOSIS, MANAGEMENT AND OUTCOME OF HEART DISEASE IN SUDANESE PATIENTS

For Personal Use. Copyright HMP 2013

CONGENITAL HEART DEFECTS IN ADULTS

Congenital Heart Defects

aortic regurgitation, vena contracta area, vena contracta width, live three-dimensional echocardiography

Congenital Heart Disease An Approach for Simple and Complex Anomalies

Occlusion in Piglets With a "Buttoned" Double-Disk Device

Original Article Safe and effective guidance by intracardiac echocardiography for transcatheter closure in atrial septal defects

Tricuspid and Pulmonic Valve Disease

Multidetector computed tomography in the evaluation of atrial septal defects

Transcription:

Echocardiographic Guidance During Placement of the Buttoned Double-Disk Device for Atrial Septa1 Defect Closure L. LUANN MINICH, M.D., and A. REBECCA SNIDER, M.D. Department of Pediatrics, C.S. Mott Children s Hospital, University of Michigan Medical Center, Ann Arbor, Michigan The usefulness of two-dimensional and Doppler echocardiography during buttoned double-disk device closure of an atrial septal defect was evaluated in 20 consecutive patients at the time of interventional catheterization. Transesophageal echocardiography was used in 11 patients (ages 5 to 62 years, weights 20 to 91 kg). Because of the size of the available transesophageal echo probe, transthoracic echocardiography was used in the remaining 9 patients (ages 4 to 5.5 years, weights 14 to 21 kg). In the transesophageal echo group, 1 patient was found to have no atrial septal defect despite a previous diagnosis by transthoracic echocardiography, 3 patients had atrial septal defects too large for closure despite attempts in 2, and 7 patients had transesophageal echo guided device placement. All of these 7 patients had small residual shunts by color Doppler, 2 had unusual arm positions, and 2 had surgical removal of the device due to embolization to the pulmonary artery in 1 and failure to obtain close approximation of the occluder and counteroccluder in 1. In the transthoracic echo group, 2 patients had atrial septal defects too large for closure, 1 patient had no femoral venous access, and 6 patients had transthoracic echo guided device placement. All of these 6 patients had small residual shunts by color Doppler and 3 of the 6 had unusual arm positions. For atrial septal defect sizing, transesophageal echo measurements correlated with catheter balloon size more closely than did transthoracic echo measurements (P = 0.97 us 0.86). Echocardiography was particularly useful for sizing the defect in two orthogonal views (n = 18), sizing total atrial septal length to determine maximum usable device size (n = 15), imaging septal rims (n = 19), determining effectiveness of balloon occlusion for sizing (n = 16), placement of occluder and counteroccluder (n = 15), detecting residual shunts (n = 15), and detecting unusual arm positions with or without new-onset valve regurgitation (n = 5). Thus, echocardiographic imaging is an essential component of atrial septal defect closure during cardiac catheterization. (ECHOCARDIOGRAPHY, Volume 10, November 1993) Doppler ultrasound, two-dimensional echocardiography, atrial septal defect, cardiac catheterization, transesop hageal echocard iography As the number and types of interventional procedures being performed in the cardiac catheterization laboratory have increased, new uses of echocardiographic techniques have evolved. Imaging from both transthoracic and transesophageal approaches has improved the guidance and evaluation of various types of trans- Address for correspondence and reprints: A. Rebecca Snider, M.D., Duke University Medical Center, Box 3107, Durham, NC 27710. Fax: 919-681-7892. catheter devices for closure of atrial and ventricular septal This study was performed to evaluate the usefulness of two-dimensional and Doppler echocardiography during buttoned double-disk device closure of an atrial septal defect. Patients Methods From March 1990 to April 1991,20 consecutive patients underwent cardiac catheteriza- Vol. 10, No. 6,1993 ECHOCARDIOGRAPHY: A Jml. of CV Ultrasound & Allied Tech. 567

MINICH AND SNIDER tion for closure of an atrial septal defect with the buttoned double-disk device. Their ages ranged from 4.5 to 62 years and their weights ranged from 14.2 to 91.0 kg. There were 17 females and 3 males. All patients were referred with the diagnosis of a secundum atrial septal defect. Three patients had a patent foramen ovale believed to be the source of paradoxical emboli, 4 patients had a small atrial septal defect with minimal or no right ventricular volume overload, and 13 patients had a moderate-to-large atrial septal defect with right ventricular and right atrial volume overload. Associated cardiac defects included mild tricuspid regurgitation in 8 patients, mild mitral regurgitation in 3, mitral valve prolapse in 3, left superior vena cava to the coronary sinus in 1, bicuspid aortic valve in 1, and repaired coarctation of the aorta in 1. Interventional Catheterization Procedure The techniques used for placement of the buttoned double-disk device have been described in detail previ~usly.~-~ In 12 patients, the procedure was performed under general anesthe- sia with endotracheal intubation and, in 8 patients, the procedure was performed under sedation with frequent small doses of ketamine and midazolam. In each patient, right heart catheterization was performed and pressures and oximetry data were obtained in all chambers. An arterial line was placed for blood pressure monitoring throughout the case. A long 8- Fr sheath was positioned in the mid-left atrium to deliver the occluder. This sheath was then withdrawn to the mid-right atrium to deliver the counteroccluder. The occluder and counteroccluder were buttoned across the defect and the device was released. Echocard iographic Evaluation Two-dimensional and Doppler echocardiographic examinations were performed on all patients before, during, and after placement of the button device. Transesophageal echocardiography was used in 11 patients ranging in age from 5 to 62 years and in weight from 20 to 91 kg. Because of the size of the available transesophageal probe (5-MHz imaging frequency, 1 1-mm tip diameter), transthoracic echocardi- Figure 1. Four-chamber view obtained from the transverse transesophageal echo plane demonstrating left-to-right shunting by color Doppler across a large secundum atrial septal defect. LA = left atrium; LV = left ventricle; RA = right atrium; RV = right ventricle. 568 ECHOCARDIOGRAPHY A Jml. of CV Ultrasound & Allied Tech. Vol. 10, No. 6,1993

ECHOCARDIOGRAPHY IN ASD CLOSURE Figure 2. Four-chamber view from the same patient demonstrating balloon sizing of the atrial septal defect under transesophageal echo guidance. The lack of shunting by color Doppler indicates successful balloon occlusion of the defect. ography from a subcostal or low left parasternal approach was used in the remaining 9 patients who ranged in age from 4 to 5.5 years and in weight from 14 to 21 kg. The type and location of the atrial septal defect were determined (Fig. 1). Measurements of the diameter of the atrial septal defect were made in two orthogonal views using on-line calipers. A similar technique was used to measure the total atrial septal length (used to determine the maximum usable device size). After balloon occlusion of the atrial septal defect as described in previous ~tudies,~,~ color Doppler was used to detect any residual shunts and, thus, determine the effectiveness of the occlusion (Fig. 2). Color Doppler mapping techniques were used to detect the direction of shunting, the location of additional atrial septal defects, and residual shunting after device placement. Results Eleven patients were evaluated with transesophageal echocardiography. In this group, 1 patient was found to have no atrial septal defect despite a previous diagnosis by transthoracic imaging. The size of the defect was found to be too large for closure by the maximum usable device in 3 patients despite attempts in 2. Device placement under transesophageal echo guidance was performed in the remaining 7 patients. All of these 7 patients had small residual shunts by color Doppler (Fig. 3). Two of the 7 patients had abnormal arm positions: 1 patient had the occluder protruding into the mitral valve with new-onset mild mitral regurgitation and the counteroccluder protruding into the tricuspid valve (Fig. 4); the other patient had the counteroccluder protruding into the left atrium. Two of the 7 patients required surgical removal of the device: 1 patient had a device that unbuttoned and embolized to the pulmonary artery; the other patient had a device in which the occluder and counteroccluder could not be approximated (faulty device?) causing the flap valve of the foramen ovale to remain in the open position (Fig. 5). Nine patients were evaluated with transthoracic echocardiography. In this group, 2 patients had atrial septal defects that were too Vol. 10, No. 6, 1993 ECHOCARDIOGRAPHY A Jrnl. of CV Ultrasound & Allied Tech. 569

MINICH AND SNIDER Figure 3. Four-chamber view from the same patient showing the button device in place over the atrial septa1 defect with a small residual shunt by color Doppler. LA = left atrium; LV = left ventricle: RA = right atrium; RV = right ventricle. large for closure with the largest available device. One patient with previous aortic coarctation repair had no femoral venous access. The remaining 6 patients underwent device placement under transthoracic echo guidance. All of these 6 patients had small residual shunts by color Doppler. Three of the 6 patients had ab- Figures 4. Four-chamber view in the transverse transesophageal echo plane showing the device protruding into the mitral valve and tricuspid valve. Figure 5. Longitudinal transesophageal echo view showing the occluder in the left atrium widely separated from the counteroccluder and holding the flap valve open. Note the bright echoes arising from the button (arrow) and the echoes arising from the loop of suture material used to perform the buttoning of the two portions of the device. 570 ECHOCARDIOGRAPHY A Jrnl. of CV Ultrasound & Allied Tech. Vol. 10, No. 6,1993

ECHOCARDIOGRAPHY IN ASD CLOSURE transthoracic echo measurements (r2 = 0.97 vs 0.86). Figure 6. Subcostal long-axis transthoracic echo view showing the tip of the counteroccluderprojecting down the inferior uena cava. normal arm positions: 2 patients had the counteroccluder projecting down the inferior vena cava (Fig. 6); 1 patient had the occluder protruding into the mitral valve with new-onset mild mitral regurgitation and the counteroccluder protruding into the tricuspid valve. For both the transesophageal echo and transthoracic echo patient groups, the uses of echocardiography during interventional catheterization are summarized in Table I. Also, transesophageal echo measurements of the atrial septal defect diameter correlated with catheterization balloon sizing more closely than did TABLE I Uses of Echocardiography Use (1) Sizing the defect in two orthogonal views (2) Sizing total septal length to determine maximum usable device size (3) Imaging septal rims (4) Determining the effectiveness of balloon occlusion (5) Occluder and counteroccluder placement (6) Residual shunts (7) Detecting unusual arm positions (8) Detecting new-onset valve regurgitation No. of Pts. 18 15 19 16 15 15 5 2 Discussion Two-dimensional and Doppler echocardiography have been used routinely to evaluate the size, location, and anatomy of the atrial septal defect. In older patients with larger body surface areas, transthoracic imaging is often inadequate, decreasing the sensitivity and specificity of the examinati~n.~,'~ Newer transesophageal echo techniques that provide posterior windows for clear imaging of the atrial septum and surrounding structures have overcome this problem.11-16 In this study, echocardiography played an important role in the evaluation of patients undergoing atrial septal defect closure with the transcatheter double-disk device (Table I). Measurements of the at,rial septal defect were made in two orthogonal views to determine the size of the device needed to occlude the defect. To determine the maximal usable device size, measurements of the total atrial septal length were also made. In addition to these measurements, balloon sizing of the atrial septal defect was performed using color flow Doppler to insure the effectiveness of the occlusion. After the defect size was determined, the location of the closure device and its components were monitored continuously by systematically sweeping the transducer to scan the atrial septum and surrounding structures in multiple planes. As the arms of the device were not all in the same plane, scanning in multiple planes was essential. The button of the device was visualized and its location during fastening of the occluder and counteroccluder was monitored. The positions of the arms of the device were evaluated with respect to the rims of the atrial septal defect, pulmonary and systemic venous inflows, and tricuspid or mitral valve funnels. Color Doppler was used to evaluate any new-onset valve regurgitation or the development of venous obstruction due to unusual arm positioning. The presence of residual atrial shunting was readily determined with Doppler color flow mapping. Echocardiography was useful in determining if the device was unstable, Vol. 10, No. 6,1993 ECHOCARDIOGRAPHY A Jrnl. of CV Ultrasound & Allied Tech. 571

MINICH AND SNIDER mobile, or dislodged after placement. Progression or resolution of shunting, valve regurgitation, or venous obstruction was readily assessed with serial follow-up Doppler echocardiographic examinations. Since the long-term effects of these devices are unknown, serial echocardiographic studies would also provide additional information regarding thrombus formation or embolization. Echocardiography is useful for sizing the atrial septal defect in two orthogonal views, sizing the total septal length to determine maximum usable device size, imaging septal rims, determining effectiveness of balloon occlusion for sizing, placement and buttoning of the occluder and counteroccluder, detecting residual shunts, and locating abnormal arm positions with or without new-onset valve regurgitation. Thus, echocardiographic imaging is an essential component of atrial septal defect closure with a catheter device. 1. 2. 3. 4. 5. References Hellenbrand WE, Fahey JT, McGowan FX, et al: Transesophageal echocardiographic guidance of transcatheter closure of atrial septal defect. Am J Cardiol 1990;66:207-213. Stumper 0, Witsenburg M, Sutherland GR, et al: Transesophageal echocardiographic monitoring of interventional cardiac catheterization in children. J Am ColE Cardiol 1991;18: 1506-1514. Sideris EB, Sideris SE, Fowlkes JP, et al: Transvenous atrial septal defect occlusion in piglets with a buttoned double-disk device. Circulation 1990;81:312-318. Sideris EB, Sideris SE, Thanopoulos BD, et al: Transvenous atrial septal defect occlusion by the buttoned device. Am J Cardiol 1990;66: 1524-1526. Rao PS, Wilson AD, Levy JM, et al: Role of buttoned double-disc device in the management of atrial septal defects. Am J CardioZ1992;123: 191-200. 6. Rao PD, Wilson AD, Chopra PS: Transcatheter closure of atrial septal defect by buttoned de-. vices. Am J Cardiol 1992;69:1056-1061. 7. King TD, Thompson SL, Mills NL Measurement of atrial septal defect during cardiac catheterization: Experimental and clinical results. Am J Cardwl 1978;41:537-542. 8. Rao PS, Langhough R Relationship of echocardiographic, shunt flow, and angiographic size to the stretched diameter of the atrial septal defect. Am Heart J 1991;122:505-508. 9. Shub C, Dimopoulos IN, Seward JB, et al: Sensitivity of two-dimensional echocardiography in the direct visualization of atrial septal defect utilizing the subcostal approach: Experience with 154 patients. J Am Coll Cardiol 1983;2: 127-135. 10. Khandheria BK, Shub C, Tajik AJ, et al: Utility of color flow imaging for visualizing shunt flow in atrial septal defect. Znt J Cardiol 1989;23: 91-98. 11. Mehta RH, Helmcke F, Nanda NC, et al: Transesophageal Doppler color flow mapping assessment of atrial septal defect. J Am Coll Cardiol 1990~16:1010-1016. 12. Pearson AC, Labovitz AJ, Tatineni S, et al: Superiority of transesophageal echocardiography in detecting cardiac source of embolism in patients with cerebral ischemia of uncertain etiology. J Am Coll Cardiol 1991;17:66-72. 13. Kronzon I, Tunick PA, Freedberg RS, et al: Transesophageal echocardiography is superior to transthoracic echocardiography in the diagnosis of sinus venosus atrial septal defect. JAm Coll Cardiol 1991;17:537-542. 14. Stumper 0, Kaulitz R, Elzenga NJ, et al: The value of transesophageal echocardiography in children with congenital heart disease. J Am SOC Echocardiogr 1991;4: 164-176. 15. Ritter SB: Transesophageal real-time echocardiography in infants and children with congenital heart disease. J Am Coll Cardiol 1991;18: 569-580. 16. Pearson AC, Nagelhout D, Castello R, et al: Atrial septal aneurysm and stroke: A transesophageal echocardiographic study. J Am Coll Cardiol 1991;18:1223-1229. 572 ECHOCARDIOGRAPHY: A Jrnl. of CV Ultrasound & Allied Tech. Vol. 10, No. 6, 1993