SPME-LC Fibers for a Variety of Applications

Similar documents
Ion Exchange and Reversed Phase interactions in selective Bio-SPME extractions of designer drugs

Detection of Low Level of Chloramphenicol in Milk and Honey with MIP SPE and LC-MS-MS

Transfer and Speed-up of Methods to Fused-Core Particle Columns EPA Method 1694

SYSTEMATIC EVALUATION OF SOLID- PHASE MICROEXTRACTION COATINGS FOR UNTARGETED METABOLOMIC PROFILING OF BIOLOGICAL FLUIDS BY LIQUID CHROMATOGRAPHY-MASS

Restek PAL SPME Fibers cat.#

Core E Analysis of Neutral Lipids from Human Plasma June 4, 2010 Thomas J. Leiker and Robert M. Barkley

Enrichment of Phospholipids from Biological Matrices with Zirconium Oxide-Modified Silica Sorbents

The Raptor HILIC-Si Column

Alternative Method of Hybrid SPE Sample Preparation for High Recovery LC-MS Analysis of Pharmaceutical Compounds in Plasma

Comprehensive Study of SLE as a Sample. Preparation Tool for Bioanalysis

Performance of an ultra low elution volume 96-well plate

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Quantitative Determination of Terpenes in Cannabis Using Headspace Solid Phase Microextraction and GC/MS

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

LC-MS/MS Method for the Determination of Tenofovir from Plasma

Matrix Factor Determination with the Waters Regulated Bioanalysis System Solution

Impact of Reversed-Phase Chiral Chromatography on the LC-MS Analysis of Drugs in Biological Fluids

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1.

Overview. Introduction. Experimental. Cliquid Software for Routine LC/MS/MS Analysis

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis

Development of a Bioanalytical Method for Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

Matrix-induced Signal Enhancement of Propamocarb in LC-MS/MS

Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system

Development and Validation of an UPLC-MS/MS Method for Quantification of Mycotoxins in Tobacco and Smokeless Tobacco Products

Using Hydrophilic Interaction Chromatography (HILIC) for the Retention of Highly Polar Analytes

Systematic Evaluation of Solid Phase Extraction (SPE) Chemistries for the Determination of Acidic, Neutral, and Basic Drugs

Protein Precipitation for Biological Fluid Samples Using Agilent Captiva EMR Lipid 96-Well Plates

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.

Extraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis

Surviving Matrix Effects Experiments. Grace van der Gugten St. Paul s Hospital, Vancouver, BC, Canada

Overcoming the Challenges of Sample Preparation and LC/MS/MS Method Development for Clinical Applications

High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS)

Simple Method (IS-MRM) to Monitor Lysophospholipids and Phospholipids During LC-MS Method Development via In-Source CID

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column

Dr. Erin E. Chambers Waters Corporation. Presented by Dr. Diego Rodriguez Cabaleiro Waters Europe Waters Corporation 1

Gas Chromatography Syringe Selection Guide

Application Note. Abstract. Authors. Pharmaceutical

Fig. 1: Chemical structure of arachidonic acid COOH CH 3

Filtration Approaches to Sample Preparation and Cleanup. Golnar Javadi Application Engineer Sample Preparation Products

Rapid and Robust Detection of THC and Its Metabolites in Blood

The Development of LC/MS Methods for Determination of MDMA (Ecstasy) and Metabolites in Biological Samples

Reporter. High Resolution Separation of Human Serum Albumin Tryptic Digest using Fused-Core HPLC Columns

A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS

Analysis of Cholesterol-Lowering Drugs (Statins) Using Dried Matrix Spot Technology

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

Raptor HILIC-Si: Simplify the Switch to HILIC

Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ

Direct Analysis of Folic Acid in Digestive Juices by LC/TOF-MS Application

Improved Isolation and Analysis of Mycotoxins from Cereals, Beer and Wine

Sample Preparation Techniques for Biological Matrices: Finding the right balance to achieve optimal results

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis

LC-Based Lipidomics Analysis on QTRAP Instruments

Determination of Patulin in Apple Juice Using SPE and UHPLC-MS/MS Analysis

Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS

LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell 120 EC C18 Column

Supplementary Information

Raptor HILIC-Si: Simplify the Switch to HILIC

LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine

Determination of Selected Illegal Drugs and its Important Metabolites in Waste Water by Large Volume Direct Injection HPLC-MS/MS

Analysis of Acrylamide in French Fries using Agilent Bond Elut QuEChERS AOAC kit and LC/MS/MS

Quantitative Analysis of Underivatized Amino Acids in Plant Matrix by Hydrophilic Interaction Chromatography (HILIC) with LC/MS Detection

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

UCT SELECTRA C18 HPLC COLUMN INNOVATION THROUGH CHEMISTRY

Impurity Profiling of Carbamazepine by HPLC/UV

Extraction of 25-hydroxy Vitamin D from Serum Using ISOLUTE. PLD+ Prior to LC-MS/MS Analysis

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Quantitative Analysis of Opiates in Urine Using RRHT LC/MS/MS. Application. Authors. Introduction. Abstract. Forensics

Chip-Based E-Tip SPE followed by Infusion MS. Copyright by Jack Henion, 2015 Lecture 1, Page 30

Quantitative Determination of Drugs of Abuse in Human Plasma and Serum by LC/MS/MS Using Agilent Captiva EMR Lipid Cleanup

Extraction of a Comprehensive Steroid Panel from Human Serum Using ISOLUTE. SLE+ Prior to LC/MS-MS Analysis

[ APPLICATION NOTE ] Oasis PRiME HLB Cartridge for Cleanup of Infant Formula Extracts Prior to UPLC-MS/MS Multiresidue Veterinary Drugs Analysis

A Definitive Lipidomics Workflow for Human Plasma Utilizing Off-line Enrichment and Class Specific Separation of Phospholipids

LC/MS/MS Analysis of Metabolites of Synthetic Cannabinoids JWH-018 and JWH-073 in Urine

Studies on Stationary Phase Selectivity for Solid-Core Particles

LC-MS/MS analysis of Chlorates in Milk and Whey Powder using the Agilent 6470 QQQ

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

Sample Concentration and Analysis of Human Hormones in Drinking Water

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

Analyze Drugs of Abuse with Agilent J&W Ultimate Plus Tubing in an Inert Flow Path

Comparison of Biotage Extrahera vs. Manual Sample Processing Using a Vacuum Manifold

Meeting the LC-MS needs of a highthroughput. laboratory. April 18 th. 10:00 [New York]/ 15:00 [London]

Supplementary Information. Effects of Perfluorooctanoic Acid on Metabolic Profiles in Brain and Liver of Mouse by a

Integration of steroids analysis in serum using LC-MS/MS with full-automated sample preparation

Agilent 6470 Triple Quadrupole LC/MS System and EMR-Lipid. The Combination for Confident Pesticide Quantitation. Christoph Mueller

Application Note LCMS-108 Quantitation of benzodiazepines and Z-drugs in serum with the EVOQ TM LC triple quadrupole mass spectrometer

Simultaneous Determination of Prescription and Designer Benzodiazepines in Urine and Blood by SPE and LC-MS/MS

Development and Validation of Multiresidue Pesticide Methods at FDA/CFSAN

Metabolomic fingerprinting of serum samples by direct infusion mass spectrometry

Fast quantitative Forensic Analysis of THC and its Metabolites in Biological Samples using Captiva EMR- Lipid and LC/MSMS

Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual

LC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined

Liquid Chromatography Syringes

Transcription:

SPME-LC Fibers for a Variety of Applications Robert Shirey 1, Craig Aurand 1, Dajana Vuckovic 2, Katherine Stenerson 1, Yong Chen 1, Leonard Sidisky 1, and Janusz Pawliszyn 2 1 Supelco, Div. of Sigma-Aldrich, Bellefonte, PA 16823 USA 2 Department of Chemistry, University of Waterloo, Waterloo, ON Canada N2L 3G1 T410041 www.sigma-aldrich.com

Abstract An SPME fiber has been developed that is specifically designed for solvent desorption. The fiber coating contains bonded HPLC particles embedded in a proprietary binder that has biocompatible properties. This presentation highlights the extraction of drugs such as carbamazepine and propranolol from biological fluids at therapeutic levels. Low cost devices have been developed that will allow single-use extractions for both in-vivo and in-vitro applications. 2

Introduction All of the commercially available SPME fibers contain coatings primarily designed for thermal desorption and GC analysis. A new line of SPME fibers has been developed specifically for solvent desorption with biocompatible properties. Biocompatible fibers reduce surface adhesion of proteins and other large macromolecules while allowing the extraction of small analytes. Unlike the current multi-use fiber assemblies, these fibers are contained in devices that will make single-use extractions cost effective. This presentation highlights important parameters in the development of the coated fibers and devices. A variety of applications showing the extraction and analysis of small molecules from biological fluids will be presented. 3

Goals of Development of SPME Fibers for Solvent Desorption 1. Fiber coating must be durable and reproducible 2. Fiber coating must not swell in water or organic solvents 3. Must be able to coat HPLC particles on fiber 4. Binder should not affect uptake of analytes 5. Binder should be biocompatible a. Resists large macromolecules b. Can be used with in-vivo type experiments without harming organism 6. Device needs to be low cost for single use analysis 4

Experimental and Results Fiber Coating - Process and Properties Silica particles (3 µm or 5 µm) are embedded in a biocompatible proprietary binder Particles are coated on a durable, flexible 200 µm metal fiber using an automated coating process (45 µm coating thickness variability 1-2%). Findings Binder is inert and does not swell in water or organic solvents Binder does not impede extraction of small molecules Binder repels proteins and large macromolecules 5

Swelling of Fiber Coating upon Solvent Exposure Fibers soaked for 15 min. in each solvent Bonded Silica Fiber Carbowax -TPR Coating thickness µm Coating thickness µm 15 min. in Solvent 15 min. in Solvent Difference Solvent No Solvent Difference No Solvent Water 44 44 0 50 60 10 Acetonitrile 44 44 0 50 51 1 Methanol 44 44 0 50 61 11 Dichloromethane 44 44 0 50 52 2 Hexane 44 44 0 50 50 0 Acetone 44 44 0 50 50 0 Water:ACN 44 44 0 50 70 20 Water:MeOH 44 44 0 50 68 18 6

If swelling occurs, the coating can be more easily damaged and removed from the fiber core, especially when a fiber is retracted into a needle. The results show that SPME fibers developed with GC type phases are subject to swelling in some solvents, but the newly developed fibers for solvent desorption do not swell in most commonly used extraction solvents. 7

Extraction of Propranolol and 4-Hydroxypropranolol (4-HP) Metabolite 8

Procedure for Extraction and Analysis Fiber Type RPA Fiber, 45 µm coating thickness Sample Fiber Conditioning Extraction Desorption 500 µl and 100 µl, spiked phosphate buffer and rat plasma adjusted to ph 4.0 with 25% H 3 PO 4 15 min. in methanol, followed by 15 min. in water 10 min., static 60 min. in 100 µl 13 mm NH 4 OAc in 90:10 ACN:H 2 O Instrument Applied Biosystems 3200QT Column Discovery HS F5; 5 cm x 2.1 mm, 3 µm Mobile Phase 2 mm ammonium formate in 90:10 acetonitrile:water Flow 200 µl/min. Temperature 35 C Injection Volume 5.0 µl Source Conditions Turbo ion spray ESI +, MRM Q1 Mass (amu) Propranolol: 260.21 4-hydroxypropranolol: 276.21 Q3 Mass (amu) Propranolol: 183.00 4-hydroxypropranolol: 173.10 Dwell time 150 msec 9

HILIC Mode Separation of Propranolol and 4-HP XIC of +MRM (3 pairs): 260.2/183.0 amu from Sample 11 (042508011) of 042508.wiff (Turbo Spray) Max. 3046.7 cps. 3000 6.84 2800 Propranolol 2600 2400 2200 2000 1800 1600 6.66 1400 1200 1000 800 600 4HP-metabolite 400 200 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 Time, min 6.50 7.32 10

Linearity of Extractions of Propranolol and 4-HP from 100 µl Samples 1.80E+05 1.60E+05 1.40E+05 1.20E+05 4-HP: plasma Propranolol: plasma 4-HP: buffer Propranolol: buffer R 2 = 0.998 Response 1.00E+05 8.00E+04 6.00E+04 4.00E+04 2.00E+04 0.00E+00 R 2 = 0.9588 R 2 = 0.9847 R 2 = 0.9087 0 20 40 60 80 100 120 Conc. (ng/ml) 11

The results show that the analytes can be extracted out of a small volume of either buffer or plasma with good linearity at low concentration levels. The more polar metabolite is not extracted as efficiently as the parent drug. Also, the recovery of both analytes is less out of plasma compared to buffer. This is due to binding of the drugs to proteins in the plasma. It was shown that it can take multiple hours for the binding equilibrium between the drugs and protein to be met. If the extraction occurs immediately after spiking the drugs into the plasma, the difference in recovery between buffer and plasma is much smaller. Better linearity is obtained if full protein binding equilibrium is obtained. An advantage of SPME is that it only extracts free (unbound) drug that is therapeutically active. 12

LC-MS Analysis of Drugs in Plasma: Comparison of SPME Extraction to Direct Injection on the Matrix Background and Detection of the Drugs Direct Injection after protein precipitation SPME Extraction TIC of +MRM (1 pair): Exp 1, from Sample 4 (042508005) of 042508.wiff (Turbo Spray) M ax. 2472.0 cps. TIC of +MRM (1 pair): Exp 1, from Sample 1 (042508001) of 042508.wiff (Turbo Spray) M ax. 116.0 cps. 24 7 2 7.52 24 0 0 7.38 23 0 0 22 0 0 7.62 21 0 0 7.23 20 0 0 MRM 184/104 for 19 0 0 18 0 0 7.86 17 0 0 16 0 0 Phospholipids 7.14 8.9 0 15 0 0 14 0 0 7.08 9.3 8 8.76 13 0 0 8.12 12 0 0 9.56 11 0 0 5.8 5 9.69 10 0 0 4.5 1 90 0 6.1 7 80 0 9.91 70 0 10.12 60 0 6.3 4 50 0 5.57 10. 38 40 0 4.26 5.46 10.76 30 0 4.11 20 0 11.71 10 0 1.11 0 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 14 Time, min 2400 2300 2200 2100 2000 MRM 184/104 for 1900 1800 1700 Phospholipids 1600 1500 1400 1300 1200 1100 1000 90 0 80 0 70 0 60 0 50 0 40 0 30 0 20 0 10 0 4.05 5.13 6. 29 6.5 2 6.71 3.85 5.01 7.82 7. 9 2 8.408. 76 9.13 0.46 0.71 1.21 1.74 2.10 3.46 10. 19 10.65 11.21 12.16 12.73 13.44 13.6714.86 0 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 14 XIC of +MRM (3 pairs): Exp 2, 260.2/183.0 amu from Sample 1 (042508001) of 042508.wiff (Turbo Time, Spray) min M ax. 830.0 cps. XIC of +MRM (3 pairs): Exp 2, 260.2/183.0 amu from Sample 4 (042508005) of 042508.wiff (Turbo Spray) M ax. 71 0.0 cps. 83 0 80 0 5.89 70 0 6.00 75 0 65 0 60 0 55 0 50 0 45 0 40 0 35 0 30 0 25 0 5.88 6.08 MRM 260./183.0 for Propranolol, 276.21/173.1 for 4-HP 70 0 65 0 60 0 55 0 50 0 45 0 40 0 35 0 30 0 25 0 MRM 260./183.0 for Propranolol, 276.21/173.1 for 4-HP 20 0 5.84 20 0 15 0 15 0 10 0 50 3.64 5.70 6.27 6.67 10 0 50 2.52 3.74 4.35 4.95 5.69 6.15 6.27 0 1 2 3 4 5 6 7 8 9 1 0 1 1 12 1 3 1 4 Time, min 0 1 2 3 4 5 6 7 8 9 1 0 1 1 12 1 3 1 4 Tim e, min 13

Phospholipids (PL) are large molecules that can interfere with the analysis of drugs by supressing ions, especially if the PL elute with the analytes of interest. It is common to analyze drugs in plasma by precipitating proteins followed by direct injection of the supernatant. Often not all of the PL precipitate when acetonitrile is added to the plasma which can result in supression specific for the drugs detected by the LC-MS system. The above figures compare the analysis of the drugs and PL by precipitation of proteins in plasma followed by direct injection, to extraction of untreated plasma using SPME followed by desorption and analysis. The ion chromatograms are at the same intensity levels. The results show that SPME does not extract PL due to the biocompatible polymer, but the drugs of interest are extracted at similar levels to direct injection that contained a high concentration of PL. 14

Fiber Pipette Design and Use 15

A low cost device has been designed that contains a coated SPME fiber in a disposable pipette tip. The tip can be inserted into low volume vials for extraction and desorbed in 50 µl of solvent contained in a 100 µl conical vial. Multiple samples can be extracted at one time and the desorption can be accomplished in one step with multiple vials and fibers. The vials containing the desorbed analytes can be placed in an autosampler for analysis. It is possible to put tips in a plate format to simplify the extraction process. Reproducibility Reproducibility of the area response of drugs extracted with 10 fiber tips per lot, typically ranges between 3% and 9% relative standard deviation. Various drugs used to evaluate the tips include cocaine, oxycodone, propranolol and benzodiazepines along with their common metabolites. The variation was calculated without correction with an internal standard. 16

Single Use Biocompatible Fiber Probes for in-vivo Analysis 17

Probes have been designed so that blood could be sampled in-vivo from animals with the use of a shunt device. Also, probes could be directly inserted into plant and animal tissues for direct analysis of small molecules. 18

Comparison of SPME in-vivo Pharmokinetics (PK) Study of Carbamazepine (CBZ) from Mice Whole Blood to Extracts of Plasma Removed from Mice 10000 CBZ Concentration (ng/ml) 1000 100 10 1 SPME 1 mouse for all time periods (triplicate runs ) Terminal blood draw Plasma from 18 mice 0 60 120 180 240 300 Slide Courtesy of Ines de Lannoy-NoAb BioDiscoveries. Time (min) 19

The above slide shows the PK of CBZ in mice. A 2 mg/kg dose of CBZ was given to mice and the level of the drug in the blood stream is monitored over time. The traditional way of monitoring the drug is to remove blood at various time intervals usually 6-8 times over a 24 hour period followed by extraction using SPE. Because mice have a very limited volume of blood, the doped mouse is sacrificed between 2 and 3 extractions. In this study triplicate samples are obtained at each time point; therefore, 18 mice were sacrificed to obtain plasma. This is costly and the data are slightly skewed because the metabolic rates can differ between mice. The staff at NoAb BioDiscoveries developed a shunt device that passes the blood of the mouse through the shunt containing a port that allows the SPME fiber to be inserted for a 2 min. extraction of the drugs. Extraction of drugs with the fibers can be done multiple times without harming the mouse. For the SPME portion of this study 3 mice were used, with each mouse surviving the entire timed study. 20

Conclusions SPME fiber coatings have been specifically designed for HPLC use and bio-applications Fiber does not swell in water and/or solvents Fiber coating is biocompatible Fiber coating is durable and reproducible Fiber can be inserted into a pipette tip for easy handling and automation. Fiber probe is suitable for in-vivo and in-vitro applications Different coatings are being evaluated 21

Acknowledgements Ines de Lannoy In-vivo applications, NoAb Biodiscoveries 22