INSTRUCTIONS FOR USE

Similar documents
Stratis INSTRUCTIONS FOR USE. Needle-free Injection System. 0.5mL volume (+/-5%)

INSTRUCTIONS FOR PREPARING AND GIVING AN INJECTION OF ENBREL POWDER

I n s t r u c t i o n M a n u a l

How to use your gonal-f pre-filled pen

Instructions for Use Enbrel (en-brel) (etanercept) for injection, for subcutaneous use Multiple-dose Vial

Instructions for Use HEMLIBRA (hem-lee-bruh) (emicizumab-kxwh) injection, for subcutaneous use

How to Use ENBREL : Vial Adapter Method

Instructions for Use. For use with. 10 mg vial

How to use your Pergoveris pre-filled pen

Lilly. Disposable Insulin Delivery Device User Manual

HumaPen LUXURA HD INSULIN DELIVERY DEVICE INSTRUCTIONS FOR USE

PRE-FILLED PEN 300 IU/0.5 ml N F

BAYER: KOGENATE FS WITH BIOSET (Recombinant FVIII)

EVER Pharma D-mine Pen Pen injector for Apomorphine 10 mg/ml

Patient Information Publications Warren Grant Magnuson Clinical Center National Institutes of Health

ALPROLIX Coagulation Factor IX (Recombinant), Fc Fusion Protein INSTRUCTIONS FOR USE Do not Do not YOUR KIT CONTAINS:

insafe System - Directions for Use

For use only with Lilly 3 ml insulin cartridges (100 units/ml). Do not use other brands of insulin cartridges.

INSTRUCTIONS FOR USE TYMLOS (tim lows ) (abaloparatide) injection, for subcutaneous use

For use only with Lilly 3 ml insulin cartridges (100 units/ml). Do not use other brands of insulin cartridges.

Instructions For Use. SOLUTION FOR INJECTION IN PRE-FILLED PEN 250 micrograms

PEN USER MANUAL Byetta 5 micrograms solution for injection in pre-filled pen (exenatide)

Instructions for Use Enbrel (en-brel) (etanercept) Single-use Prefilled SureClick Autoinjector

EVOGAM. Information for patients Evogam 2014 NZ Patient Brochure Update v11

SELF-INJECTION GUIDE

PLEASE READ THIS USER MANUAL BEFORE USE

HumaPen SAVVIO INSULIN DELIVERY DEVICE INSTRUCTIONS FOR USE

Sharps Container (not included) 1 Gather and check supplies. Gather supplies

EVOGAM. Information for patients Evogam NZ Patient Brochure Update FA3

Vial. A healthcare provider should show you how to inject MYALEPT before you use it for

Before you use the TALTZ autoinjector, read and carefully follow all the step-by-step instructions.

MYALEPT (MAI-uh-lept) (metreleptin) for injection for subcutaneous use

INSTRUCTIONS FOR USE. Norditropin NordiFlex Somatropin (rdna origin) injection 30 mg/3 ml Prefilled Pen

PRODUCT DESCRIPTION 4 INTENDED USE AND INDICATIONS 4 INJEX COMPONENTS 5 PREPARING THE INJEX SYSTEM 6 PREPARING THE INJECTOR 6 FILLING THE AMPOULE 7

Pfizer, BeneFIX R2 Recombinant Factor IX

The Enbrel SureClick autoinjector is a single-dose prefilled autoinjector. It contains one 50 mg dose of Enbrel.

A patient guide to administration of subcutaneous immunoglobulin replacement therapy - using manual push technique

User Manual Important: First read the Medication Guide that comes inside your FORTEO carton.

1 Before You Begin. Injection Instructions. Safety Tips. Disposing of Used Syringes, Needles, and Supplies. Having Someone Help You With Injections

Instructions for Use Enbrel (en-brel) (etanercept) injection, for subcutaneous use Single-dose Prefilled Syringe

Education for self administration of intravenous therapy HOME IV THERAPY. 30 minute - Baxter Pump Tobramycin

DONGBAO PEN (ELECTRONIC) INSTRUCTION MANUAL

SymlinPen (SĬM-lĭnPen) 120 (pramlintide acetate) Pen-Injector

INSTRUCTIONS FOR USE. EMGALITY TM (em-gal-it-ē) (galcanezumab-gnlm)

IMPORTANT: PLEASE READ. Don t

1.0 Purpose The purpose of this guideline is to ensure the safe administration of intramuscular injections to Cheshire Ireland service users.

Cap Clip Rubber Seal Plunger Pen Body Dose Window

Blood Glucose Monitoring System. User Guide

IMPORTANT: PLEASE READ

MICAFUNGIN MIXING

INSULIN INJECTION KNOW-HOW

CoaguChek S System. Quick Reference Guide. This is a CLIA-waived System. Coagulation Testing with Fresh Whole Blood

Instructions for Use. Welcome!

IMPORTANT: PLEASE READ

NovoPen Echo User guide

The Enbrel SureClick autoinjector is a single-dose prefilled autoinjector. It contains one 50 mg dose of Enbrel.

Medi-Jector VISION Needle-Free Insulin Injection System. Instruction Manual

Patient/Carer instructions for the administration of Subcutaneous Cytarabine

Methotrexate Injections

For use only with INSTRUCTIONS FOR USE

Patient Information. EGRIFTA (eh-grif-tuh) (tesamorelin for injection) for subcutaneous use

Items in the package:

FUZEON enfuviride WHAT IS IN THIS LEAFLET BEFORE YOU USE FUZEON WHAT FUZEON IS USED FOR. When you must not use it. Use in children

Acknowledgement goes to WHO for use of their hand washing technique

SELF-InjECTIOn. PEGASYS (peginterferon alfa-2a) PROCLICk AUTOInjECTOR PEGASYS PREFILLED SYRInGE PEGASYS VIAL with SYRInGE

Education for Self Administration of Intravenous Therapy HOME IV THERAPY PICC. Portacath

Standard operating procedures for preparation and administration of intramuscular injections. No Action Rationale

Instructional Guide RECONSTITUTION OF IDELVION USING THE MIX2VIAL TRANSFER SET

PLEASE READ THESE INSTRUCTIONS BEFORE USE

Autopen 24 is an easy to use insulin injection pen, designed for use with 3.0ml sanofi aventis insulin cartridges. Compatible with all pen needles*.

A step-by-step preparation guide

PRO-V IDS Kit. Bisco. Instructions for Use. Provisional Restorative System

Mixing Two Insulins. Getting Ready. What to Do

Standard Operating Procedure for cannulation

Tips for Training New Customers

Instructions for Use. HUMALOG KwikPen. insulin lispro injection (rdna origin) 100 units/ml, 3 ml pen

Instructions for Use TRULICITY. dulaglutide solution for injection, for subcutaneous use. 1.5 mg/0.5 ml Single-Use Pen, Once-Weekly

Patient Education Pharmacy Services

TRANSCRIPT for Lantus SoloSTAR pen injection for your patients

Instructions for Use. BASAGLAR KwikPen. insulin glargine injection (100 units/ml, 3 ml pen)

PATIENT INSTRUCTIONS FOR USE SINGLE- DOSE PREFILLED SYRINGE

Normal Immunoglobulin (Human) 16%, solution for subcutaneous administration.

Glucose Meter. User Guide. Veterinary Monitoring System. For dog and cat use only

Package Leaflet: Information for the User

PATIENT / USER INFORMATION LEAFLET. Cinryze 500 Units powder and solvent for solution for injection C1 inhibitor (human)

SCIG INFUSIONS A PRACTICAL GUIDE FOR PATIENTS

SELF-INJECTION TRAINING GUIDE

PART III: CONSUMER INFORMATION

INSTRUCTIONS FOR USE HUMIRA 40 MG/0.8 ML, 20 MG/0.4 ML AND 10 MG/0.2 ML SINGLE-USE PREFILLED SYRINGE

PATIENT INFORMATION. D iabetes. What You Need to Know About. Insulin

DO NOT TRANSFER TO A SYRINGE SEVERE OVERDOSE CAN RESULT

For use only with Puregon cartridge (follitropin beta injection) INSTRUCTIONS FOR USE

Insulin Basic facts. Patient Education Patient Care Services. What is insulin? What types of insulin are there? Basal Insulin

A STEP-BY-STEP GUIDE FOR HEALTHCARE PROFESSIONALS TO USING THE ENBREL 50MG PRE-FILLED PEN MYCLIC

STEP-BY-STEP GUIDE TO SELF-INFUSION. Subcutaneous Administration of GAMMAGARD LIQUID

HUMULIN 70/30 KwikPen

Blood Glucose & Ketone Monitoring System

Dear HighQ Check System Owner :

GlucCell TM SYSTEM USER S GUIDE Ver 2.1 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System

Inspection Window. Syringe Body

Transcription:

Comfort Injects 50 Comfort-in INSTRUCTIONS FOR USE English user manual 1

Introduction Thank you for choosing the Comfort in Needle free Injection system, developed with your comfort and convenience in mind. This manual contains step by step instructions how to use the it and keep it ready to operate. Before you start using the Comfort in, please ensure that you familiarise yourself with the device by reading carefully the instructions before use. It is highly recommended after having studied the manual, first practice with the test fluid in order to become familiar with the Comfort in. If you are internet savvy please check you tube video instruction at http://youtu.be/nkw8ynq1hb4 2

Table of Contents Introduction What is the Comfort in System for? Items in the Package The Comfort in System Overview The Comfort in Injector Body Principle of Operation Specifications Pressure Lever The needle free syringe Filling Adaptor Instructions for Use the Comfort in Prepare the Comfort in Injector Fill the Syringe Load the Injector Give Injection Disposal Maintenance and Care Warranty Further Information 3

What is the Comfort in System for? The Comfort in system is a compact, spring powered technology that delivers up to 0.5 milliliters of liquid medication or vaccine by means of a narrow, high velocity fluid jet, which penetrates the skin in less than a one third of a second. The injection is fast and safe and intended for subcutaneous injections in adults.healthcare providers who routinely administer injections may use the Comfort in Injection System. It can also be used by patients authorised by their physicians to self inject, or have other individuals administer injections of prescribed medication. The majority of people who used the system have reported feeling no pain, while some indicated feeling slight pressure, a pinch or a snap at the time of the injection. Overall, user surveys indicate a preference for Needle free injections over those given with conventional needles. Needle free technology significantly reduces the fear and anxiety associated with a needle injection. It also eliminates needle stick injuries, greatly reduces the need for sharps management and disposal costs. 4

5

Items in the Package The Components of the Comfort in System consist of: An Injector Body A Pressure Lever A sterile single use filling adaptor with a cap A disposable single use sterile 0.5 ml graduated needle free syringe The Comfort in System is sold as a complete starter kit contained in a carrying case. The starter kit contains the injector device, the pressure lever, eight (8) sterile needle free (0.5 ml) syringes, one (1) sterile adaptor (Fig.1). Items not provided with the package: Alcohol swabs Ice pack Disposable ice pack Vials of medicine for injections Figure 1: Comfort in Starter Package 6

The Comfort in System Overview The Comfort in Injector Body The injector is a reusable compact spring actuated needle free hypodermic injector consisting of the main body, injection button and front head of injector which contains the required dose unit marks and spring. Figure 2: The Comfort in Injector Body Head of Injector Injection Button Principle of Operation The Comfort in Injector delivers liquid medications subcutaneously by creating a very narrow, high velocity fluid stream which penetrates the skin and delivers the medicine into the body. Energy to propel medicine is supplied by a hand held spring powered injector. When released, the spring 7

energy is transferred to the syringe plunger, expelling medicine through a very small orifice (0.15mm) in the face of the syringe contacting the user's skin. Specifications Table 1: Injector Body Specifications An Injector Body Description Dimensions 136.5mm(L) 27 mm (D) (before injection) 136.5mm(L) 27 mm (D) (after injection) Weight 110g ± 5% Dose accuracy For < 0.2 ml: the expelled dose ± 0.01 ml For > 0.2ml: the expelled dose ± 5% Noise when accidentally < 60dB fired into air Storage Between 5 C 40 C; RH 40% 95% Spring Force 120 ± 5% lbf Spring 4100 ± 10% Pressure Spring Life 10,000 (Warranty for device: 1 year) Cycle Pressure Lever The pressure lever is used to charge/load the spring within the injector for injection. Pressure Lever Description Body Dimensions 90mm(L) 73mm(H) 28 mm (W) Weight 100g ± 5% 8

The needle free syringe aka Nozzle The needle free syringe is a single use, transparent, disposable container consisting of a barrel to hold 0.5 ml of medicine or vaccine, a plunger to discharge the medicine or vaccine through a small diameter orifice at the forward end of the barrel and a rubber seal at the end of the plunger to prevent rearward leakage. This part of the device comes into direct contact with the user s skin and therefore is supplied in sterile form sealed in a pouch. Figure 3: Needle free Syringe in a blister package Syringe Description Length 46.5 mm External Diameter 15 mm Dimensions Internal Diameter 10 mm Orifice Diameter 0.146 mm Weight 4.47g ± 3% 9

10

Filling Adaptor The filling adaptor allows the needlefree syringe to be filled with medicine or vaccine from the medicine or vaccine storage vials. The adaptor and its cap are supplied sterile sealed in a pouch. Figure 4: Adaptor and Cap in a Pouch Adaptor Description Dimensions Length 26.9 mm External Diameter 21 mm Weight 4.7 g ± 3% 11

Instructions for Use the Comfort in Wash your hands with soapy water before using the Injection System Prepare the Comfort in Injector Take the Pressure Lever out of the carrying case. Open the wings of the Pressure Lever so that 3 parts of the Lever: Injector Holder, Pushing Bar and Metal Pressure Stick are clearly visible 12

Insert the Injector Head into Injector Holder as shown in the pictures below Put Pressure stick into head of injector Insert the Pressure Stick into the hole of the Injector s Head. With the help of Push Bar press the Lever Stick into the Injector s Head. You should hear a click sound when the injector s spring is fully loaded. Inappropriate loading of the Injector may cause damage and malfunction of the device. Now, when the spring is loaded you can adjust the dose level by turning the head of the injector. The dose levels are printed on the blue part of the Injector Body. Hold the device so that the dose window faces you. Wind the front head of the injector to fit your dose range. The range from 0 to 10 represents 0 0.1 cc dose (or 0 10 units); the range 10 20 corresponds to 0.1 0.2 cc (or 10 20 units). 13

Warning: Using the injector without a syringe may result in damaging the device. Do not repeat dry firing. Fill the Syringe Clean your hands again Remove protective cap from the primary medicine vial Prepare top of the vial by wiping it with alcohol swab, follow aseptic techniques Open a pouch with the sterile Filling Always visually damage before torn or damaged. DO NOT re sterilise or Adaptor. inspect the package for opening it. DO NOT use it if Autoclave. Aseptically remove the filling Adaptor from packaging. Insert Adaptor s spike into the vial with twisting motion until it fully engaged. Remove the protective cap from the Adaptor 14

Open a pouch with the sterile needle free syringe. Always visually inspect the package fordamage before opening it. DO NOT use it if tornor damaged. DO NOT re sterilize. 1. Take a syringe out of its sterile pack, 2. Push plunger inwards to release it, only then pull back and forth to loosen it. 3. Pull the plunger back to the 0.5 mark to fill with air. 4. Attach the syringe (filled with air) to the adapter turn syringe clockwise to lock in, turn vial including adapter upside down, now push the air in to the vial. Attach the syringe (filled with air) to the adapter turn syringe clockwise to lock in. Turn vial including adapter upside down, now push the air in to the vial (to prevent vacuum), and now slowly pull down on Syringe Plunger to draw injectable medication to the 0.5 cc (50 units) mark on the Syringe. Then draw up and gently push the piston into syringe to the mark of your needed dose. Remove bubbles if required by gently tapping the syringe with your fingertips to push the air out. 15

Separate the Syringe from the Adaptor by unscrewing counterclockwise. The Filling Adaptor may be used to fill several Syringes from a multi dose vial. In this case replace protective adaptor cap back on the adaptor until next re filling. Keep the vial with adaptor refrigerated. Note that protective cap is designed to protect against touch contamination only, and does not provide a barrier against other forms of contamination. DO NOT re use Filling Adaptor in another vial. Doing so may contaminate contents of new vial. Tip of the Filling Adaptor (spike) is sharp. Use caution when handling. Syringes are for single patient use and not to be reused. Using a syringe more than one time may result in contamination or injector malfunction. Load the Injector Double check if the set dose on the Injector and filled volume in the needle free syringe are corresponding. In the picture, for example, the injector is set for 10 units and the syringe is filled with 10 units (0.1 cc) 16

Now take your medicine filled syringe and insert it in the head of the injector by screwing it firmly in. DO NOT direct the Syringe toward the face or nearby skin when loading the Syringe into an Injector, preparing to give an injection, or ejecting a Syringe after use. DO NOT touch Injection Button until you ready to inject into injection site to prevent from inadvertent firing.injury may occur. Partial i nsertion of Syringe into Injector may damage Syringe and/or Injector. Give Injection Any of the sites that are normally recommended for conventional needle administration can be used with the Comfort in. Choose an area with some fatty tissue. Avoid areas with a low fat content (e.g. the shinbone) or high muscle content (upper arm) to ensure subcutaneous delivery. When injecting into abdomen choose areas that are not too soft to prevent from wet shots. Improper injection site location or technique may res u lt in injury. 17

DO NOT position the Syringe directly over a blood vessel. Although injection into the vessel is highly unlikely, injection over a vessel may produce an adverse reaction including, but not limited to, bleeding, bruising, swelling, or tenderness. Select a site that is free from irritation, with a low likelihood of infection, and where the skin is intact and free from abrasions and bruises. Disinfect chosen area for administration with Alcohol swab of the syringe Place the tip against the skin firmly at 90 angle Once the tip of the syringe is tightly against the skin, push the injector button firmly. Wait 5 seconds for the medicine to penetrate the body and then remove the syringe. DO NOT deliver injection with Comfort in injector at an angle other than 90 degrees to the patient. and/or bruising. Patients receiving anticoagulants or persons with hemophilia or other coagulation disorders may have more post injection bleeding Disposal Collect used disposables in suitably labe l ed medical waste containers a n d follow local requ i rements for proper disposal. 18

Maintenance and Care Since Comfort in Injector and Pressure Lever are re usable components it is important to maintain these parts of the System appropriately to ensure dose accuracy and life cycle of the device. Clean these parts regularly and store them in the provided carrying case. DO NOT autoclave Injector or Pressure Lever Injector and Pressure Lever may be cleaned and disinfected by wiping the exterior surfaces by using 70% Isopropyl Alcohol. Warranty The Comfort in System comes with a limited manufacturer warranty against defects in materials and workmanship for 1 year from the date of purchase.the warranty does not cover damages caused by improper usage and handling, accident and/or negligent care. 19

Further Information Ordering Information ASTS Enterprises Trading as Injex Australia. 2/11 Evans street,burwood,vic,3125 +61 3 98888771 info@injex.com.au 20