Agilent Anion-Exchange Media for Proteins - Loading vs Resolution - Effect of Flow Rate and Example Protein Separations

Similar documents
The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns.

Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate

Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit

Data File. Sephadex ion exchange media. Ion exchange chromatography. Introduction. Sephadex ion exchangers General description

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP

Ion Exchange Chromatography COSMOGEL IEX Series Columns

Determination of Tetracyclines in Chicken by Solid-Phase Extraction and High-Performance Liquid Chromatography

Transferring a Method for Analysis of DNPH-Derivatized Aldehydes and Ketones from HPLC to UHPLC

Columns for HPLC. Columns for HPLC

Superose 6 Increase columns

TSKgel Hydrophobic Interaction Chromatography Columns

Application Note. Authors: C. Ledesma, M. Gibert, J.R. Gibert Ingenieria Analitica S.L. Extracts from various food products

Analysis of Counterfeit Antidiabetic Drugs by UHPLC with the Agilent 1220 Infinity Mobile LC

Ultrafast analysis of synthetic antioxidants in vegetable oils using the Agilent 1290 Infinity LC system

Extended Application Note

LC/MS Analysis of Various Hydrophilic Compounds Using a Polymer-Based Amino Column - Shodex TM HILICpak TM VG-50 2D

Confident, lower-pressure analysis of carbohydrates, alcohols, and organic acids. Agilent Hi-Plex Ligand-Exchange HPLC Columns

High-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

Agilent Technologies Prep LC Columns

Hydrophobic Interaction Chromatography

LC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined

Increasing resolution using longer columns while maintaining analysis time Advantages of the wide power range of the Agilent 1290 Infinity LC System

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

Product Guide for LudgerSep TM C3 anion exchange HPLC Column for Glycan Analysis

Ultimate Core Performance to Maximize Your Investment

Application Note. Authors. Abstract. Food

HPLC to UHPLC Transfer of USP Method for Amlodipine Besylate Using the Agilent 1290 Infinity II LC

Separation of Vitamin D and Vitamin D Metabolites on FLARE C18 MM (Mixed Mode) HPLC Column

InertSustainBio C18. Rapid Separations of Proteins and Peptides

Separation of Macrocyclic Lactones (Avermectins) on FLARE C18 MM & FLARE C18+ Columns

Modified QuEChERS for HILIC LC/MS/MS Analysis of Nicotine and Its Metabolites in Fish

Application Note. Small Molecule Pharmaceuticals. 2-Ethyl-2-phenylmalonamide Ethosuximide Primidone Carbamazepine. Carbamazepine-

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages

Performance Characteristics of the Agilent 1290 Infinity II Multicolumn Thermostat

GlycanPac AXH-1 Columns

Selectivity Comparison of Agilent Poroshell 120 Phases in the Separation of Butter Antioxidants

GlycanPac AXR-1 Columns

Converting a CHP Method for Insulin to Agilent Poroshell 120 Columns

Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column

A Novel HILIC Column for High Speed N-linked Glycan Analysis

Comparison of a UPLC Method across Multiple UHPLC Systems

Thermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

Application Note. Abstract. Authors. Pharmaceutical

Application Note. Separation of clindamycin phosphate and process impurities. Summary. Introduction. Category Pharmaceutical analysis Matrix

SeQuant ZIC -HILIC For all who expect more...

BabyBio IMAC columns DATA SHEET DS

Analysis of HMF by HPLC

Profiling of Endogenous Metabolites Using Time-of-Flight LC/MS with Ion Pair Reverse Phase Chromatography

Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system

Analyze Barbiturates in Urine with Agilent 6430 LC/MS/MS and Poroshell 120 EC-C18

USP purity analysis of pravastatin sodium using the Agilent 1120 Compact LC

Maximizing Efficiency Using Agilent InfinityLab Poroshell 120 Columns

Rebaudioside a From Multiple Gene Donors Expressed in Yarrowia Lipolytica

Core-Shell Technology for Proteins and Peptides

HPLC Analysis with Fluorescence Detection of Chlorophyll Degradation Products Pheophytins and Pyropheophytin in Virgin Olive Oil

[ APPLICATION NOTE ] The Separation of 8 -THC, 9 -THC, and Their Enantiomers by UPC 2 Using Trefoil Chiral Columns INTRODUCTION APPLICATION BENEFITS

Analytical and Preparative SFC Columns

Columns for HPLC. Columns for HPLC. Basic principles of preparative HPLC

SeQuant ZIC -HILIC For all who expect more...

YMC-Actus. Columns for Semi-preparative HPLC. Selectivity Durability Loadability

Chromatogram Search Tool Search by compound name, synonym, CAS # or keyword Pinnacle II Columns

APPLICATIONS Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns

LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell 120 EC C18 Column

2D-LC as an Automated Desalting Tool for MSD Analysis

Comparison of conventional HPLC with UPLC method for determination of albuterol sulfate and it s impurities in pharmaceutical formulation

High Resolution Glycopeptide Mapping of EPO Using an Agilent AdvanceBio Peptide Mapping Column

C30 ISOMERS HAVE MET THEIR MATCH

Analysis of Acrylamide in French Fries using Agilent Bond Elut QuEChERS AOAC kit and LC/MS/MS

Chiral Multicolumn Method Development on the Agilent 1260 Infinity II SFC System

Application Note. Sensitive analysis of the lactose content of lactose-free labelled products using HPAEC-PAD. Summary.

Authors. Abstract. Introduction. Environmental

Online 2D-LC Analysis of Complex N-Glycans in Biopharmaceuticals Using the Agilent 1290 Infinity 2D-LC Solution

Application Note. Author. Abstract. Introduction. Food Safety

Reduced Ion Suppression and Improved LC/MS Sensitivity with Agilent Bond Elut Plexa

RITONAVIRI COMPRESSI RITONAVIR TABLETS. Final text for addition to The International Pharmacopoeia (July 2012)

176 YMC Chiral Columns

Separation of 15 Underivatized Saccharide and Sialic Acid USP Standards

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid

ZIDOVUDINE, LAMIVUDINE AND ABACAVIR TABLETS Draft proposal for The International Pharmacopoeia (September 2006)

Performance characteristics of the Agilent 1100 Series preparative pump. Technical Note. Abstract

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

Development and Validation of a Polysorbate 20 Assay in a Therapeutic Antibody Formulation by RP-HPLC and Charged Aerosol Detector (CAD)

TENOFOVIR TABLETS: Final text for addition to The International Pharmacopoeia (June 2010)

Metal Chelate Affinity Chromatography

Fluorescent Carbon Dots as Off-On Nanosensor for Ascorbic Acid

Rapid Separation of Fatty Acid Methyl Esters

Sepax Technologies, Inc.

Choosing Preparative Columns

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

PAPRIKA EXTRACT SYNONYMS DEFINITION DESCRIPTION FUNCTIONAL USES CHARACTERISTICS

Product Guide for LudgerSep TM R1 HPLC Column for DMB labelled Sialic Acid Analysis

Determination of Amantadine Residues in Chicken by LCMS-8040

Thermo Scientific Hypersil BDS Columns

Separation of Saccharides Using TSKgel Amide-80, a Packing Material for High-performance Normal Phase Partition Chromatography (2) Table of Contents

Transcription:

Agilent Anion-Exchange Media for Proteins - Loading vs Resolution - Effect of Flow Rate and Example Protein Separations Technical Overview Introduction PL-SAX is a hydrophilic strong anion-exchange chromatographic packing material from Agilent Technologies, Inc. The combination of the rigid macroporous polystyrene/divinylbenzene (PS/DVB) polymer matrix and chemically stable quaternized polyethyleneimine coating allows the analysis of biomolecules over a wide range of mobile phase conditions and ph. The physical stability of the media permits their use with high eluent flow rates and high speed gradients for very rapid separations. This excellent stability ensures both rapid equilibration between separations and the use of aggressive cleanup procedures employing high salt, NaOH, mineral and organic acids, and a wide range of organic solvents. In these examples we investigated the effects of different column and packing characteristics using common proteins as experimental analytes.

Separation of ovalbumin and soyabean trypsin inhibitor For globular protein analysis and purification, the PL-SAX 1000Å material has the optimum pore size for maximum loading with low band broadening. Figure 1 shows the separation of ovalbumin and soyabean trypsin inhibitor at three representative flow rates with resolution factors for their separation calculated for different flow rates, shown in Table 1. Column: PL-SAX 1000Å 8 µm Buffer: 0.01 M Tris, ph 8, eluting salt NaCl Flow rate: see Figure 6 R S = (t - t 1 ) w + w 1 Table 1. Resolution factors calculated for different flow rates. Flow Rate (ml/min) R s 0.5.79 1.0 4.7 1.5 4.46.0.68.0.7 4.0.09 Peak Identification 1. Ovalbumin. Soyabean trypsin inhibitor 0.5 ml/min 1.0 ml/min 4.0 ml/min 1 1 1 0 min 0 min 0 min Figure 1. Separation of ovalbumin and soyabean trypsin inhibitor at three representative flow rates on Agilent PL-SAX 1000Å.

Protein loading study with PL-SAX 1000Å For globular protein analysis and purification, the PL-SAX 1000Å material has the optimum pore size for maximum loading with low band broadening. The more open pore structure of the 4000Å is preferred for high resolution and high speed applications or for the separation of very large biomolecules. The resolution factors for the separation of ovalbumin and soyabean trypsin inhibitor were calculated for various protein loadings using the 1000Å and 4000Å material. Columns: see Figure Eluent B: A + 0.5 M NaCl, ph 8 9 Key: PL-SAX 1000Å 8 µm, 50 x 4.6 mm PL-SAX 4000Å 8 µm, 50 x 4.6 mm R s 0 Total protein mass (mg) 5 Figure. Calculation of resolution factors for various protein loadings using Agilent PL-SAX 1000Å and 4000Å material for the separation of ovalbumin and soyabean trypsin inhibitor. The resolution factors for the separation of ovalbumin and soyabean trypsin inhibitor were calculated for various protein loadings on PL-SAX 1000Å columns with different internal diameters. With the 10 mm column, over 1 mg of protein can be loaded before the resolution factor falls by 40%. This compares with 1.5 mg on the 5 mm id columns (Figure ).

Columns: PL-SAX 1000Å 8 µm, 50 x 5 mm PL-SAX 1000Å 8 µm, 100 x 10 mm Eluent B: A + 0.5 M NaCl, ph 8 8 R s Key: PL-SAX 1000Å 8 µm, 50 x 5 mm PL-SAX 1000Å 8 µm, 100 x 10 mm 0 0 Total protein mass (mg) Figure. Calculation of resolution factors for various protein loadings on Agilent PL-SAX columns with different internal diameters for the separation of ovalbumin and soyabean trypsin inhibitor. 1 Protein loading study with PL-SAX 4000Å Resolution factors for the separation of ovalbumin and soyabean trypsin inhibitor were also calculated for protein loadings using PL-SAX columns of different sizes containing 4000Å, 8 µm material. At low protein loadings (0.1 mg), the resolution of the standard protein mixture is comparable. However, the resolution, as would be expected, falls off more rapidly with the shorter column length. At increased protein loads, less dependency is observed with increasing column id (Figure 4). Columns: PL-SAX 4000Å, 50 x 4.6 mm (p/n PL1551-180) PL-SAX 4000Å, 150 x 4.6 mm (p/n PL1551-80) Eluent B: A + 0.5 M NaCl, ph 8 4

10 Key: PL-SAX 4000Å 8 µm, 150 x 4.6 mm PL-SAX 400Å 8 µm, 50 x 4.6 mm R s 0 Total protein mass (mg) Figure 4. Calculation of resolution factors for various protein loadings using different sized columns containing Agilent PL-SAX 4000Å 8 µm material for the separation of ovalbumin and soyabean trypsin inhibitor. 5 Protein standards The physical stability of PL-SAX media permits their use with high eluent flow rates and high speed gradients for rapid separations (Figure 5). Column: PL-SAX 1000Å 8 µm, 50 x 4.6 mm Eluent B: A + 0.5 M NaCl, ph 8 1 Peak Identification 1. Myoglobin. Conalbumin. Ovalbumin 4. Soyabean trypsin inhibitor 4 0 min 15 Figure 5. Raw data chromatogram for a mixture of protein standards on Agilent PL-SAX 1000Å. 5

Analysis of egg white proteins The hydrophilic, strong anion-exchange chromatographic packing of PL-SAX analyzes many biomolecules over a wide range of mobile phase conditions and ph. The separation of egg white proteins is shown as an example (Figure 6). The frozen egg white was thawed, passed through a 45 µm syringe filter and diluted (1:8) with Eluent A. Column: PL-SAX 1000Å 8 µm, 50 x 4.6 mm (p/n PL1551-180) Eluent B: A + 0.5M NaCl, ph 8 Peak Identification 1. Conalbumin. Ovalbumin. Unknown 1 0 min Figure 6. Raw data chromatogram from an Agilent PL-SAX 1000Å column for a mixture of egg white proteins (separation courtesy of Mary Ann Rounds, Purdue University, USA). 0 6

Analysis of representative whey proteins The analysis of representative whey proteins is straightforward on PL-SAX 1000Å columns. Column: PL-SAX 1000Å 8 µm, 50 x 4.6 mm (p/n PL1551-180) Eluent A: 0.0 M Tris HCI, ph 7 Eluent B: A + 0.5 M CH COONa, ph 7 Gradient: Linear 0-50% B in 10 min Peak Identification 1. Carbonic anhydrase. α-lactalbumin. β-lactoglobulin B 4. β-lactoglobulin A 1 4 0 min Figure 7. Raw data chromatogram for a mixture of whey proteins on Agilent PL-SAX 1000Å. 18 7

Agilent PL-SAX Strong Anion-Exchange Columns PL-SAX is designed for anion-exchange HPLC separations of proteins and deprotected synthetic oligonucleotides under denaturing conditions. The strong anion-exchange functionality, covalently linked to a chemically stable polymer, extends the operating ph range. What s more, anion-exchange capacity is independent of ph. These data represent typical results. For further information, contact your local Agilent Sales Office. www.agilent.com/chem This information is subject to change without notice. Agilent Technologies, Inc. 011 Published in UK, August, 011 5990-8777EN