Quality assurance in external radiotherapy

Similar documents
Data Collected During Audits for Clinical Trials. July 21, 2010 Geoffrey S. Ibbott, Ph.D. and RPC Staff

Eric E. Klein, Ph.D. Chair of TG-142

Reference Photon Dosimetry Data for the Siemens Primus Linear Accelerator: Preliminary Results for Depth Dose and Output Factor

EORTC Member Facility Questionnaire

Patient and Linac QA - present and the future

7/10/2015. Acknowledgments. Institution-specific TG-142? AAPM:Task Group-142. Failure-Mode & Effects Analysis

CHAPTER 5. STUDY OF ANGULAR RESPONSE OF asi 1000 EPID AND IMATRIXX 2-D ARRAY SYSTEM FOR IMRT PATIENT SPECIFIC QA

The RPC s Evaluation of Advanced Technologies. AAPM Refresher Course July 29, 2008 Geoffrey S. Ibbott, Ph.D. and RPC Staff

Dosisverifikation mit Delta 4 Discover während der Behandlung

Disclosure. Outline. Machine Overview. I have received honoraria from Accuray in the past. I have had travel expenses paid by Accuray in the past.

INTRODUCTION. Material and Methods

An Independent Audit and Analysis of Small Field Dosimetry Quality Assurance. David Followill IROC Houston QA Center

IMRT QUESTIONNAIRE. Address: Physicist: Research Associate: Dosimetrist: Responsible Radiation Oncologist(s)

Indiana University Health Proton Therapy Center. Chee-Wai Cheng, Ph.D.

Special Procedures Rotation I/II SBRT, SRS, TBI, and TSET

I. Equipments for external beam radiotherapy

The Journey of Cyberknife Commissioning

Quality Assurance in Radiation Therapy

RADIATION ONCOLOGY RESIDENCY PROGRAM Competency Evaluation of Resident

QA for Clinical Dosimetry with Emphasis on Clinical Trials

Implementation of advanced RT Techniques

Accuracy Requirements and Uncertainty Considerations in Radiation Therapy

Leila E. A. Nichol Royal Surrey County Hospital

DEPT OF RADIATION ONCOLOGY DEPT OF RADIATION ONCOLOGY

Canadian Partnership for Quality Radiotherapy. Technical Quality Control Guidelines for Gamma Knife Radiosurgery. A guidance document on behalf of:

Who Should Know Radiation Oncology Coding?

Assessment of Dosimetric Functions of An Equinox 100 Telecobalt Machine

RADIOTHERAPY- CURRENT SITUATION AND FUTURE TRENDS

S. Derreumaux (IRSN) Accidents in radiation therapy in France: causes, consequences and lessons learned

Presented by: Rebecca M. Howell PhD, DABR, FAAPM. Results from Voluntary Independent External Peer Review of Beam Output

Problems and Shortcomings of the RPC Remote Monitoring Program of Institutions Dosimetry Data

Level of Accuracy Practically Achievable in Radiation Therapy. David Followill and RPC staff August 6, 2013

SRS/SBRT Errors and Causes

A new geometric and mechanical verification device for medical LINACs

Albert Lisbona Medical Physics Department CLCC Nantes Atlantique a

DOSIMETRIC COMPARISION FOR RADIATION QUALITY IN HIGH ENERGY PHOTON BEAMS

An anthropomorphic head phantom with a BANG polymer gel insert for dosimetric evaluation of IMRT treatment delivery

What Can Go Wrong in Radiation Treatment: Data from the RPC. Geoffrey S. Ibbott, Ph.D. and RPC Staff

Are Transmission Detectors a Necessary Tool for a Safe Patient Radiation Therapy Program?

6/29/2012 WHAT IS IN THIS PRESENTATION? MANAGEMENT OF PRIMARY DEVICES INVESTIGATED MAJOR ISSUES WITH CARDIAC DEVICES AND FROM MED PHYS LISTSERVS

Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR

Introduction of RapidArc TM : an example of commissioning and implementing a QA programme for a new technology

7/31/2012. Volumetric modulated arc therapy. UAB Department of Radiation Oncology. Richard Popple, Ph.D.

Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies

IMRT/IGRT Patient Treatment: A Community Hospital Experience. Charles M. Able, Assistant Professor

Dose rate response of Digital Megavolt Imager detector for flattening filter-free beams

Varian Treatment. Streamlined Treatment Delivery Management Application. Specifications

A Dosimetric study of different MLC expansion aperture For the radiotherapy of pancreas cancer

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

ARCCHECK: COMPREHENSIVE EVALUATION OF THE DIODE ARRAY PHANTOM - RULES OF THUMB FOR PHANTOM USE FOR QA. By Vibha Chaswal, Ph.D.

Therapeutic Medical Physics. Stephen J. Amadon Jr., Ph.D., DABR

CURRICULUM OUTLINE FOR TRANSITIONING FROM 2-D RT TO 3-D CRT AND IMRT

TLD as a tool for remote verification of output for radiotherapy beams: 25 years of experience

8/2/2018. Disclosure. Online MR-IG-ART Dosimetry and Dose Accumulation

Standardization of dosimetry practices for small and large animal irradiation in radiobiological studies

Overview of TG225 - Medical Physics Practice Guideline #1

Analysis of 6 MV Energy Quality File Index using Percentage Depth Dose (PDD) and Tissue Phantom Ratio (TPR) Methods on Linac Siemens and Electa

Learning Objectives. Clinically operating proton therapy facilities. Overview of Quality Assurance in Proton Therapy. Omar Zeidan

Image Guided in Radiation Therapy (IGRT) Chumpot Kakanaporn Med Phys Radiation Oncology Siriraj Hospital

Verification of Relative Output Factor (ROF) Measurement for Radiosurgery Small Photon Beams

RTOG DOSIMETRY DATA SUBMISSION

Quality assurance and credentialing requirements for sites using inverse planned IMRT Techniques

Office: Cell Ph:

iviewdose Confidence and assurance in dose delivery

Verification of treatment planning system parameters in tomotherapy using EBT Radiochromic Film

Understanding Radiation Therapy. For Patients and the Public

Limits of Precision and Accuracy of Radiation Delivery Systems

Amendment No. 2. Item No. 2 (Rfx/ Event number )

CyberKnife Technology in Ablative Radiation Therapy. Jun Yang PhD Cyberknife Center of Philadelphia Drexel University Jan 2017

PHYS 383: Applications of physics in medicine (offered at the University of Waterloo from Jan 2015)

Plan-Specific Correction Factors for Small- Volume Ion Chamber Dosimetry in Modulated Treatments on a Varian Trilogy

Normal tissue doses from MV image-guided radiation therapy (IGRT) using orthogonal MV and MV-CBCT

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

ph fax

SunCHECK Patient Comprehensive Patient QA

Catharine Clark NPL, Royal Surrey County Hospital and RTTQA

Objective. Evaluation of Linear Accelerator Performance Standards using an Outcome Oriented Approach. Linac performance standards*

Guidelines for the use of inversely planned treatment techniques in Clinical Trials: IMRT, VMAT, TomoTherapy

Standards for Radiation Oncology

Can we hit the target? Can we put the dose where we want it? Quality Assurance in Stereotactic Radiosurgery and Fractionated Stereotactic Radiotherapy

In-Room Radiographic Imaging for Localization

Work partially supported by VisionRT

Unrivaled, End-to-End

McGill University Medical Physics Unit Radiotherapy Lab: MDPH 603 (2 credits) Winter 2017

EXPERIMENTAL RESULTS IN PERCENTAGE DEPTH DOSE (PDD) DETERMINATION AT THE EXTENDED DISTANCES *

Abstract: A National Project for the in-vivo dosimetry in radiotherapy: first results

Protura Robotic Patient Positioning System. for efficiency + performance

Curriculum Vitae. Iavor Veltchev, Ph.D., DABR

Small field dosimetry, an example of what a Medical Physicist does (& some more examples) A/PROF SCOTT CROWE MEDICAL PHYSICIST

Image Registration: The Challenge for QA Centers

IMRT Implementation And Patient Specific Dose Verification With Film And Ion Chamber Array Detectors

Commissioning and Radiobiology of the INTRABEAM System

Small field diode dosimetry

SHIELDING TECHNIQUES FOR CURRENT RADIATION THERAPY MODALITIES

Quality Assurance of TPS: comparison of dose calculation for stereotactic patients in Eclipse and iplan RT Dose

STEREOTACTIC DOSE VERIFICATION PHANTOM VERSATILE STEREOTACTIC QA PHANTOMS

Major accidents in radiotherapy

Treatment Efficiency and Optimization of Patient Care with IBA ProteusOne

A comparative study between flattening filter-free beams and flattening filter beams in radiotherapy treatment

Transcription:

Quality assurance in external radiotherapy dr. Marius Laurikaitis medical physicist Oncological Hospital of Kaunas Medical University Hospital Kaunas, 2010-10-14

Acceptance and Commissioning

Acceptance Test Testing if machine and radiation parameters is within specified limits Used Customer Acceptance Procedures or International protocols Tests for all equipment: machines, planning systems, verification systems and et. 3

Acceptance Test 4 Customer Acceptance Procedures, Varian

Commissioning Acquiring all radiation beam data required for treatment Entering these data into a computerized treatment planning system Developing all dosimetry, treatment planning and treatment procedures Verifying the accuracy of these procedures Establishing quality control tests and procedures Training all personnel 5

Commissioning 6 Faiz M. Khan, The Physics of Radiation Therapy, 2003

Quality Assurance 7

Daily QA (Linac) 8 Klein et al., Task Group 142 Report: QA of Medical Accelerators, Med. Phys.,36 (9), 2009, p. 4197-4212

Monthly QA (Linac) 9 Klein et al., Task Group 142 Report: QA of Medical Accelerators, Med. Phys.,36 (9), 2009, p. 4197-4212

Annual QA (Linac) 10 Klein et al., Task Group 142 Report: QA of Medical Accelerators, Med. Phys.,36 (9), 2009, p. 4197-4212

Annual QA (Linac) 11 Klein et al., Task Group 142 Report: QA of Medical Accelerators, Med. Phys.,36 (9), 2009, p. 4197-4212

Wedges, MLC, Imaging QA (Linac) 12 Klein et al., Task Group 142 Report: QA of Medical Accelerators, Med. Phys.,36 (9), 2009, p. 4197-4212

QA of Cobalt-60 Kutchar et al., Report of AAPM Radiation Therapy Committee Task Group 40, Med. Phys., 21(4), 1994, p. 581-618 13

QA of Simulator Kutchar et al., Report of AAPM Radiation Therapy Committee Task Group 40, Med. Phys., 21(4), 1994, p. 581-618 14

QA of Kilavoltage Equipment J.R. Williams et al., Radiotherapy Physics in Practice, 1993 15

QA after Service (Linac) Beam Quality Assurance Guidelines High Energy Clinacs, Customer Technical Bulletin, Varian 16

Real Situation 17

Roles and Responsibilities of Medical Physicists Faiz M. Khan, The Physics of Radiation Therapy, 2003 18

Radiotherapy Clinics 5 Clinics: Institute of Oncology, Vilnius University Hospital of Kaunas University of Medicine Oncological Hospital of Kaunas Medical University Hospital Klaipėda University Hospital Šiauliai Hospital 19

Radiotherapy (external) Equipment Equipment Linac Simulator Institute of Oncology, Vilnius University 3 Varian (2) 6, 15 MV Varian (1) 6 MV IMRT Varian Hospital of Kaunas University of Medicine 3 Varian (2) 6, 15 MV Siemens 6, 18 MV Stereotactic CT simulator GE X-ray therapy In future plans - Oncological Hospital of Kaunas Medical University Hosp. 1 Varian 6, 15 MV Varian Gulmay 40-220 kv Klaipėda University Hospital 1 Siemens 6, 18 MV CT simulator Siemens Gulmay 40-220 kv Šiauliai Hospital 1 Elekta 6, 15 MV CT Gulmay 30-100 kv Treatment planning Eclipse Eclipse Eclipse Xio Precise Plan system Co-60 Russia - - Russia - Verification system Aria Aria Aria Lantis Mosaiq 20

Medical Physicists Institute of Oncology, Vilnius University: 8 medical physicists Hospital of Kaunas University of Medicine: 6 medical physicists Oncological Hospital of Kaunas Medical University Hospital: 4 medical physicists Klaipėda University Hospital: 4+1 (arriving) medical physicists Šiauliai County Hospital: 2+3 (arriving) medical physicists 21

Equipment for QA Lithuanian Hygiene Standard HN 95:2005 Radiation Protection and Quality Control in Radiotherapy 22

QA in Oncological Hospital (Linac) Daily (Rad. Technologist): Door interlock Beam on indicator Audiovisual monitor Laser localization Optical distance indicator X-ray output constancy X-ray beam symmetry X-ray beam flatness Photon beam energy constancy Radiation field size Monthly: X-ray output constancy Photon beam energy constancy Light/ radiation field coincidence Emergency beam off Quarterly: PDD constancy X-ray symmetry constancy X-ray flatness constancy Mechanical tests Annually: Customer Acceptance procedures Commissioning procedures (part) 23

QA in Oncological Hospital (Kilavoltage Unit) Weekly: Door interlock Beam on indicator Calibration constancy Annually: Absolute calibration Beam Quality (HVL) 24

QA in Oncological Hospital (Simulator, CT) Simulator (Quarterly, Annually): Lithuanian Hygiene Standard HN 78:2009 Quality Control in Radiology CT (Daily, Weekly, Annually): Lithuanian Hygiene Standard HN 78:2009 Quality Control in Radiology 25

QA Procedure QA in Lithuania (Linac) Institute of Oncology, Vilnius University Oncological Hospital of Kaunas Medical University Hospital Klaipėda University Hospital Šiauliai Hospital Daily Dosimetry (quick check) Dosimetrist Rad. Technologist Med. Physicist Rad. Technologist Mechanical Dosimetrist Rad. Technologist Rad. Technologist Rad. Technologist Safety Dosimetrist Rad. Technologist Rad. Technologist Rad. Technologist Weekly Mechanical Med. Physicist Med. Physicist Safety Med. Physicist Monthly Dosimetry (water phantom) Med. Physicist Med. Physicist Med. Physicist Med. Physicist Mechanical Med. Physicist Med. Physicist Med. Physicist Med. Physicist Safety Med. Physicist 3 Months Dosimetry (big water phantom) Mechanical Dosimetry (big water phantom) Med. Physicist Med. Physicist 6 Months Med. Physicist Med. Physicist Med. Physicist Annually Dosimetry (big water phantom) Med. Physicist Med. Physicist Med. Physicist Med. Physicist Mechanical Med. Physicist Med. Physicist Med. Physicist Med. Physicist Safety Med. Physicist Med. Physicist 26

QA in Lithuania (Kilavoltage Unit) QA Procedure Oncological Hospital of Kaunas Medical University Hospital Klaipėda University Hospital Šiauliai Hospital Daily Safety Rad. Technologist Rad. Technologist Weekly Dosimetry Med. Physicist Safety Med. Physicist Monthly Dosimetry Med. Physicist Med. Physicist 3 Months Dosimetry Annually Dosimetry Med. Physicist Med. Physicist Med. Physicist 27

Thank you for your attention